At least 19 records

Development of a model and test equipment for cold flow tests at 500 atm of small nuclear light bulb configurations

A model and test equipment were developed and cold-flow-tested at greater than 500 atm in preparation for future high-pressure rf plasma experiments and in-reactor tests with small nuclear light bulb configurations. With minor exceptions, the model chamber is similar in design and dimensions to a proposed in-reactor geometry for tests with fissioning uranium plasmas in the nuclear furnace. The model and the equipment were designed for use with the UARL 1.2-MW rf induction heater in tests with rf plasmas at pressures up to 500 atm. A series of cold-flow tests of the model was then conducted at pressures up to about 510 atm. At 504 atm, the flow rates of argon and cooling water were 3.35 liter/sec (STP) and 26 gal/min, respectively. It was demonstrated that the model is capable of being operated for extended periods at the 500-atm pressure level and is, therefore, ready for use in initial high-pressure rf plasma experiments.

Jaminet, J. F.↗

LADEE Propulsion System Cold Flow Test

Lunar Atmosphere and Dust Environment Explorer (LADEE) is a NASA mission that will orbit the Moon. Its main objective is to characterize the atmosphere and lunar dust environment. The spacecraft development is being led by NASA Ames Research Center and scheduled for launch in 2013. The LADEE spacecraft will be operated with a bi-propellant hypergolic propulsion system using MMH and NTO as the fuel and oxidizer, respectively. The propulsion system utilizes flight-proven hardware on major components. The propulsion layout is composed of one 100-lbf main thruster and four 5-lbf RCS thrusters. The propellants are stored in four tanks (two parallel-connected tanks per propellant component). The propellants will be pressurized by regulated helium. A simulated propulsion system has been built for conducting cold flow test series to characterize the transient fluid flow of the propulsion system feed lines and to verify the critical operation modes, such as system priming, waterhammer, and crucial mission duty cycles. Propellant drainage differential between propellant tanks will also be assessed. Since the oxidizer feed line system has a higher flow demand than the fuel system does, the cold flow test focuses on the oxidizer system. The objective of the cold flow test is to simulate the LADEE propulsion fluid flow operation through water cold flow test and to obtain data for anchoring analytical models. The models will be used to predict the transient and steady state flow behaviors in the actual flight operations. The test activities, including the simulated propulsion test article, cold flow test, and analytical modeling, are being performed at NASA Marshall Space Flight Center. At the time of the abstract submission, the test article checkout is being performed. The test series will be completed by November, 2012

Williams, Jonathan Hunter↗

Resource Prospector Propulsion Cold Flow Test

For the past year, NASA Marshall Space Flight Center and Johnson Space Center have been working on a government version of a lunar lander design for the Resource Prospector Mission. A propulsion cold flow test system, representing an early flight design of the propulsion system, has been fabricated. The primary objective of the cold flow test is to simulate the Resource Prospector propulsion system operation through water flow testing and obtain data for anchoring analytical models. This effort will also provide an opportunity to develop a propulsion system mockup to examine hardware integration to a flight structure. This paper will report the work progress of the propulsion cold flow test system development and test preparation. At the time this paper is written, the initial waterhammer testing is underway. The initial assessment of the test data suggests that the results are as expected and have a similar trend with the pretest prediction. The test results will be reported in a future conference.

Williams, Hunter↗

A comparison of measured and predicted test flow in an expansion tube with air and oxygen test gases

Simultaneous time-resolved measurements of temperature, density, pitot pressure, and wall pressure in both air and O2 test gases were obtained in the Langley pilot model expansion tube. These tests show nonequilibrium chemical and vibrational relaxation significantly affect the test-flow condition. The use of an electromagnetic device to preopen the secondary diaphragm before the arrival of the primary shock wave resulted in an improvement in the agreement between the measured pitot pressure and the value inferred from measured density and interface velocity. Boundary-layer splitter plates used to reduce the wall boundary layer show that this disagreement in the measured and inferred pitot pressures is not a result of boundary-layer effects.

Aaggard, K. V.↗

Resource Prospector Propulsion System Cold Flow Testing

Resource Prospector (RP) is a NASA mission being led by NASA Ames Research Center with current plans to deliver a scientific payload package aboard a rover to the lunar surface. As part of an early risk reduction activity, Marshall Space Flight Center (MSFC) and Johnson Space Flight Center (JSC) have jointly developed a government-version concept of a lunar lander for the mission. The spacecraft consists of two parts, the lander and the rover which carries the scientific instruments. The lander holds the rover during launch, cruise, and landing on the surface. Following terminal descent and landing the lander portion of the spacecraft become dormant after the rover embarks on the science mission. The lander will be equipped with a propulsion system for lunar descent and landing, as well as trajectory correction and attitude control maneuvers during transit to the moon. Hypergolic propellants monomethyl hydrazine and nitrogen tetroxide will be used to fuel sixteen 70-lbf descent thrusters and twelve 5-lbf attitude control thrusters. A total of four metal-diaphragm tanks, two per propellant, will be used along with a high-pressure composite-overwrapped pressure vessel for the helium pressurant gas. Many of the major propulsion system components are heritage missile hardware obtained by NASA from the Air Force. In parallel with the flight system design activities, a simulated propulsion system based on flight drawings was built for conducting a series of water flow tests to characterize the transient fluid flow of the propulsion system feed lines and to verify the critical operation modes such as system priming, waterhammer, and crucial mission duty cycles. The primary objective of the cold flow testing was to simulate the RP propulsion system fluid flow operation through water flow testing and to obtain data for anchoring analytical models. The models will be used to predict the transient and steady state flow behaviors in the actual flight operations. All design and build efforts, including the analytical modeling, have been performed. The cold flow testing of the propulsion system was set up and conducted at a NASA MSFC test facility. All testing was completed in the summer of 2014, and this paper documents the results of that testing and the associated fluid system modeling efforts.

Williams, Hunter↗

Fluorescent Particles For Flow Testing

Small alumina spheres coated with fluorescent dye used in flow testing of transparent plastic model of check valve. Entrained fluroescent particles make flows visible. After completion of flow test, particles remaining in valve easily detectable and removed for measurement of their sizes.

Bonnell, Jeremy L.↗

Water Flow Testing and Unsteady Pressure Analysis of a Two-Bladed Liquid Oxidizer Pump Inducer

The unsteady fluid dynamic performance of a cavitating two-bladed oxidizer turbopump inducer was characterized through sub-scale water flow testing. While testing a novel inlet duct design that included a cavitation suppression groove, unusual high-frequency pressure oscillations were observed. With potential implications for inducer blade loads, these high-frequency components were analyzed extensively in order to understand their origins and impacts to blade loading. Water flow testing provides a technique to determine pump performance without the costs and hazards associated with handling cryogenic propellants. Water has a similar density and Reynolds number to liquid oxygen. In a 70%-scale water flow test, the inducer-only pump performance was evaluated. Over a range of flow rates, the pump inlet pressure was gradually reduced, causing the flow to cavitate near the pump inducer. A nominal, smooth inducer inlet was tested, followed by an inlet duct with a circumferential groove designed to suppress cavitation. A subsequent 52%-scale water flow test in another facility evaluated the combined inducer-impeller pump performance. With the nominal inlet design, the inducer showed traditional cavitation and surge characteristics. Significant bearing loads were created by large side loads on the inducer during synchronous cavitation. The grooved inlet successfully mitigated these loads by greatly reducing synchronous cavitation, however high-frequency pressure oscillations were observed over a range of frequencies. Analytical signal processing techniques showed these oscillations to be created by a rotating, multi-celled train of pressure pulses, and subsequent CFD analysis suggested that such pulses could be created by the interaction of rotating inducer blades with fluid trapped in a cavitation suppression groove. Despite their relatively low amplitude, these high-frequency pressure oscillations posed a design concern due to their sensitivity to flow conditions and test scale. The amplitude and frequency of oscillations varied considerably over the pump s operating space, making it difficult to predict blade loads.

Schwarz, Jordan B.↗

Test flow calibration study of the Langley Arc-Heated Scramjet Test Facility

The test flow at the exits of two square cross-section contoured nozzles with nominal exit Mach numbers of 4.7 and 6 has been studied as calibration data for the NASA-Langley Arc-Heated Scramjet Test Facility over simulated flight conditions from Mach 5.5 (at altitudes from 98,600-128,000 ft) to Mach 7 (at altitudes from 108,000-149,000 ft). Nozzle exit contour maps of measured thermodynamic properties, calculated Mach number, and calculated mass flow are used to determine the mass flow approaching the inlets of various scramjet engines. Good agreement is found between experimentally measured facility total mass flow and facility total mass flow determined by integration of the nozzle exit mass flow contours.

Thomas, Scott R.↗

Facility Activation and Characterization for IPD Oxidizer Turbopump Cold-Flow Testing at NASA Stennis Space Center

The Integrated Powerhead Demonstrator (IPD) is a 250K lbf (1.1 MN) thrust cryogenic hydrogen/oxygen engine technology demonstrator that utilizes a full flow staged combustion engine cycle. The Integrated Powerhead Demonstrator (IPD) is part of NASA's Next Generation Launch Technology (NGLT) program, which seeks to provide safe, dependable, cost-cutting technologies for future space launch systems. The project also is part of the Department of Defense's Integrated High Payoff Rocket Propulsion Technology (IHPRPT) program, which seeks to increase the performance and capability of today s state-of-the-art rocket propulsion systems while decreasing costs associated with military and commercial access to space. The primary industry participants include Boeing-Rocketdyne and GenCorp Aerojet. The intended full flow engine cycle is a key component in achieving all of the aforementioned goals. The IPD Program achieved a major milestone with the successful completion of the IPD Oxidizer Turbopump (OTP) cold-flow test project at the NASA John C. Stennis Space Center (SSC) E-1 test facility in November 2001. A total of 11 IPD OTP cold-flow tests were completed. Following an overview of the NASA SSC E-1 test facility, this paper addresses the facility aspects pertaining to the activation and the cold-flow testing of the IPD OTP. In addition, some of the facility challenges encountered during the test project are addressed.

Sass, J. P.↗

Flow Simulation of Solid Rocket Motors: Injection Induced Water-Flow Tests from Porous Media - 1

Prior to selecting a proper porous material for use in simulating the internal port flow of a solid rocket motor (SRM), in cold-flow testing, the flow emerging from porous materials is experimentally investigated. The injection-flow emerging from a porous matrix always exhibits a lumpy velocity profile that is spatially stable and affects the development of the longitudinal port flow. This flow instability, termed pseudoturbulence, is an inherent signature of the porous matrix and is found to generally increase with the wall porosity and with the injection flow rate. Visualization studies further show that the flow from porous walls made from shaving-type material (sintered stainless-steel) exhibits strong recirculation zones that are conspicuously absent in walls made from nodular or spherical material (sintered bronze). Detailed flow visualization observations and hot-film measurements are reported from tests of injection-flow and a coupled cross-flow from different porous wall materials. Based on the experimental data, discussion is provided on the choice of suitable material for SRM model testing while addressing the consequences and shortcomings from such a test.

Ramachandran, N.↗

Flow tests of a single fuel element coolant channel for a compact fast reactor for space power

Water flow tests were conducted on a single-fuel-element cooling channel for a nuclear concept to be used for space power. The tests established a method for measuring coolant flow rate which is applicable to water flow testing of a complete mockup of the reference reactor. The inlet plenum-to-outlet plenum pressure drop, which approximates the overall core pressure drop, was measured and correlated with flow rate. This information can be used for reactor coolant flow and heat transfer calculations. An analytical study of the flow characteristics was also conducted.

Springborn, R. H.↗

Inlet flow test calibration for a small axial compressor rig. Part 2: CFD compared with experimental results

An axial compressor test rig has been designed for the operation of small turbomachines. A flow test was run to calibrate and determine the source and magnitudes of the loss mechanisms in the compressor inlet for a highly loaded two-stage axial compressor test. Several flow conditions and inlet guide vane (IGV) angle settings were established, for which detailed surveys were completed. Boundary layer bleed was also provided along the casing of the inlet behind the support struts and ahead of the IGV. Several computational fluid dynamics (CFD) calculations were made for selected flow conditions established during the test. Good agreement between the CFD and test data were obtained for these test conditions.

Miller, D. P.↗

Description of an oscillating flow test program

A description of the University of Minnesota Oscillating Flow Test Program is presented. The rationale for isolating the oscillating flow effect for separate study, the objectives of the test program, and the program design criteria are presented along with a description of the test facility and the test plan. The program test domain covers almost the entire operating domain of Stirling engine heat exchangers expressed in terms of the appropriate dimensionless parameters. Phenomena important to Stirling engine performance which are not simulated in the test program are also discussed. Computer analysis results are used to predict apparatus performance.

Seume, J. R.↗

Turbine Air-Flow Test Rig CFD Results for Test Matrix

This paper presents the Turbine Air-Flow Test (TAFT) rig computational fluid dynamics (CFD) results for test matrix. The topics include: 1) TAFT Background; 2) Design Point CFD; 3) TAFT Test Plan and Test Matrix; and 4) CFD of Test Points. This paper is in viewgraph form.

Wilson, Josh↗

Longitudinal Stability and Control Characteristics of a Semispan Wind-Tunnel Model of the XF7U-1 Airplane and a Comparison with Complete-Model Wind-Tunnel Tests and Semispan-Model Wing-Flow Tests

An investigation was conducted on an 0.08-scale semispan model of the Chance Vought XF7U-1 airplane in the Langley high-speed 7- by 10-foot tunnel in the Mach number range from 0.40 to 0.97. The results are compared with those obtained with an 0.08-scale sting-mounted complete model tested in the same tunnel and with an 0.026-scale semispan model tested by the wing-flow method. The lift-curve slopes obtained for the 0.08-scale semispan model and the 0.026-scale wing-flow model were in good agreement but both were generally lower than the values obtained for the sting model. The results of an unpublished investigation have shown that tunnel-wall boundary-layer and strut-leakage effects can came the difference noted between the lift-curve slopes of the sting and the semispan data. Fair agreement was obtained among the data of the three models as regard the variation of pitching-moment coefficients with lift coefficient. The agreement between the complete and the semispan models was more favorable with the vertical fine on, because the wall-boundary-layer and strut leakage effects were less severe. In the Mach number range between 0.94 and 0.97, ailavator-control reversal was indicated in the wing-flow data near zero lift; Whereas, these same trends were indicated in the larger scale semispan data at somewhat higher lift coefficients.

Goodson, Kenneth W.↗

Inlet Flow Test Calibration for a Small Axial Compressor Facility. Part 1: Design and Experimental Results

An axial compressor test rig has been designed for the operation of small turbomachines. The inlet region consisted of a long flowpath region with two series of support struts and a flapped inlet guide vane. A flow test was run to calibrate and determine the source and magnitudes of the loss mechanisms in the inlet for a highly loaded two-stage axial compressor test. Several flow conditions and IGV angle settings were established in which detailed surveys were completed. Boundary layer bleed was also provided along the casing of the inlet behind the support struts and ahead of the IGV. A detailed discussion of the flowpath design along with a summary of the experimental results are provided in Part 1.

Miller, D. P.↗

Effect of Fuselage and Tail Surfaces on Low-speed Yawing Characteristics of a Swept-wing Model as Determined in Curved-flow Test Section of Langley Stability Tunnel

Results are presented of a wind-tunnel investigation made to determine the influence of the fuselage and tail surfaces on the rotary derivatives in yawing flight of a transonic-airplane configuration having 45 degrees sweptback wing and tail surfaces. The tests were run in the curved-flow test section of the Langley stability tunnel at a Reynolds number of 1.07 X 10 to the sixth power and consisted of balance measurements throughout the angle-of-attack range for several flight-path radii of curvature. The results are compared with data from forced-oscillation and free-oscillation tests, and a description of testing techniques used is included.

WIND TUNNELS↗

Effects of nozzle design parameters on the extent of quiet test flow at Mach 3.5

Tests results at the NASA Langley Research Center, involving a Mach 3.5 pilot quiet tunnel, have shown that laminar-layered nozzle walls improve boundary layer stability and reduce stream disturbance levels caused by eddy Mach wave radiation. This type of wall design is required to obtain transition Reynolds numbers on tests models as high as those previously observed in supersonic flight vehicles. The Mach 3.5 pilot nozzle wall boundary layers were tested for Tollmein-Schlichting and Goertler linear amplification, and, in an analysis of Goertler vortices in two axisymmetric Mach 5 nozzles, transition values were found to vary. These values were applied to several nozzles with similar throat heights but different expansion rates. Among the nozzles included in the study, a flat-wall radial flow nozzle and a proposed rod-wall nozzle were tested. For the highest test unit Reynolds number, it was determined that the nozzle wall surface finish should not exceed 0.3 micron. Oil flow studies have indicated that Goertler vortex disturbances were the dominant mechanism causing transition on the walls of the pilot nozzle.

Beckwith, I. E.↗