Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow-induced vibrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

One-Way Coupled Flow-Induced Vibration Analysis for a Twisted-Tube Heat Exchanger

The NEAMS program aims to develop an integrated multi-physics simulation capability “pellet-to-plant” for the design and analysis of future generations of nuclear power plants. In particular, the Reactor Product Line code suite's multi-resolution hierarchy is being designed to ultimately span the full range of length and time scales present in relevant reactor design and safety analyses, as well as scale from desktop to petaflop computing platforms. Flow-induced vibration (FIV) is a widespread problem in energy systems because they rely on fluid movement for energy conversion. Vibrating structures may be damaged as fatigue or wear occurs. Given the importance of reliable components in the nuclear industry, flow-induced vibration has long been a major concern in safety and operation of nuclear reactors. Nuclear fuel rods and steam generators have been known to suffer from flow-induced vibration and related failures.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of a Test Article and Test Facility to Investigate Flow-Induced Vibration of a Helical Coil Steam Generator

NuScale Power LLC (NuScale) is developing a small modular reactor (SMR) with unique design features and arrangements that require testing to provide quality data for safety analysis codes and design validation, as well as for technology maturation. A multi-phase testing program is underway at NuScale to demonstrate that its unique helical coil steam generator design is not susceptible to flow-induced vibration during operation. The phases of the testing program include modal testing of individual tubes during test article fabrication and modal and flow testing after test article completion. NuScale has contracted SIET S.p.A. in Piacenza, Italy for the design and fabrication of the test article and test facility. In-fabrication testing was performed at the site of test article build in Cremosano, Italy. Modal testing and flow testing of the completed test article will be performed at SIET’s facilities in Piacenza. This paper discusses the design of the test article and test facility, including supporting systems, required to generate the quality data required to support NuScale’s comprehensive vibration assessment program as part of the overall licensing effort for NuScale’s first-of-a-kind small modular light water reactor.

Flow-induced vibration, helical coil, steam genera↗

A comprehensive review of nonlinear oscillators in hydrokinetic energy harnessing using flow-induced vibrations

A comprehensive review of hydrokinetic energy converters based on alternating lift technology (ALT) is provided. Emphasis is on nonlinear oscillators based on Flow Induced Vibration (FIV) or Oscillation (FIO). Due to strong coupling in Fluid-Structure Interaction (FSI), and in order to maximize the hydrokinetic harnessed energy, design of nonlinear oscillators and analysis by model tests or computational fluid dynamics dominates this area. Research confirmed that the nonlinear oscillator can harvest energy from a stochastic excitation modeled by a generic wide spectrum, and overcome the most severe oscillator limitations: specifically, the need for continuous frequency tuning due to the narrow bandwidth response, and low efficiency outside the narrow bandwidth oscillator response. This review covers the following aspects of nonlinear oscillators in ALT converters: (1) Geometric changes in oscillator cross-section; e.g., circular, square, rectangular, or trilateral shapes. (2) Passive turbulence control of FIV/FIO. (3) Position based nonlinear stiffness. (4) Multi-cylinder synergistic FIV/FIO. (5) Mechanically linked oscillators. (6) Velocity-based, nonlinear, adaptive harnessing damping.

42 ENGINEERING↗

Adaptive harnessing damping in hydrokinetic energy conversion by two rough tandem-cylinders using flow-induced vibrations

Alternating lift technology (ALT) harnesses hydrokinetic energy from currents and tides and is different from conventional steady lift technologies (turbines). ALT is still under development with an important research issue being the mitigation of wake effect on downstream cylinders in Flow Induced Oscillations (FIO) of multi-cylinder Current Energy Converters (CEC). Rather than adjust the configuration/parameters of the converter, a more direct and effective way is to actively adjust the harnessed power. In this paper, a hydrokinetic energy converter using FIO of two cylinders in tandem in one-degree-of-freedom oscillators, with nonlinear adaptive damping and linear spring stiffness, is tested experimentally. FIO include Vortex Induced Vibrations (VIV), galloping, and their coexistence. Introducing adaptive damping into the tandem cylinders overcomes the shielding effect, which previous research on two tandem cylinders has shown to reduce power output by the downstream cylinder. Shielding along with fixed damping result either in ceasing motion due to excessive damping, or in low harnessed energy due to insufficient damping. In this experimental study, damping-to-velocity rate, linear spring-stiffness, cylinder spacing, and flow-velocity are the parameters with Reynolds number 30,000 ≤ Re ≤ 120,000. Comparison to linear-oscillators in FIO shows that this nonlinear converter, with velocity-proportional damping coefficient, is more effective over the entire FIO range but especially in galloping, where both flow and cylinder speeds are higher. Experimental results for energy harvesting, efficiency and instantaneous energy of the converter are presented and discussed supported by amplitude and frequency response data. Here the results show that the nonlinear, adaptive, velocity-proportional damping coefficient is an effective way to increase the overall harnessed power and the power of downstream cylinder. The harnessed power in the VIV to galloping transition increases by up to 94%. The most significant improvement is in the galloping region, where the increase in harnessed power and efficiency is around 33%.

13 HYDRO ENERGY↗

Development and experimental evaluation of an acoustic flow meter prototype for measuring air flow

Here, this study outlines the development and testing of a flow meter prototype specifically designed for use in nuclear reactor environments. The meter uses flow-induced vibration to measure flow rates and is designed for remote monitoring in harsh environments where radiation can damage electronics. The device generates a vibration signal produced by a feedback system when fluid flows out of an orifice and interacts with a downstream wedge. The frequency of the vibration signal corresponds directly to flow rate and velocity. The study investigates geometric parameters intrinsic to the prototype, such as orifice height, width, edge distance, and chamber length. Different configurations were also tested, including a bypass loop with variable cross-sections around the device. The investigation results reveal the impact of these geometric parameters on the vibration signal output, providing valuable insights for future design improvements and enhancing the effectiveness of flow metering systems used in nuclear reactor applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flow Instabilities in boiling channels and their suppression methodologies—A review

Small modular reactors (SMRs) are gaining significant attention as a promising solution for clean and sustainable nuclear-power generation. However, the operation of SMRs is subject to various challenges, including two-phase flow instabilities. Flow instability has the potential to trigger flow-induced vibration and cyclic fluctuations in local thermal stress. These instabilities frequently manifest because of the complex interplay among a multitude of factors, encompassing thermal-hydraulic conditions, the geometric configuration of the steam generator, and operational parameters. These conditions could subsequently lead to premature critical heat flux, equipment malfunctions, and other safety concerns. Here, the endeavor to address steam-generator flow instabilities is of utmost importance in augmenting the sustainability and efficiency of contemporary energy production. This study offers a comprehensive review of instabilities in two-phase flow, with a particular focus on the influential factors impacting the stability of flow boiling. Furthermore, it delves into the processes of identifying, characterizing, and ameliorating these instabilities, emphasizing pivotal findings, methodologies employed, and avenues for prospective research. The primary parameters of concern encompass the efficient transfer of thermal energy, the optimization of mass-flow rates, and the establishment of favorable boundary conditions, all in the context of steam generator design to alleviate instability for water-cooled SMRs. These discernments bear substantial ramifications for enhancing reactor performance and ensuring operational safety.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Prognostic model and failure mechanisms of steam generators in Sodium-Cooled fast reactors

This paper presents a prognostic model for sodium-cooled fast reactor (SFR) steam generators (SGs). Here, the purpose of the model is to estimate the remaining useful life of SFR SGs and thus to support the decision-making of autonomous control. SFR SGs are of great interest for plant integrity due to their harsh operation environment. They operate at higher temperatures and higher coolant-to-steam pressure differences than those of current light water reactors (LWR). The severity of the SFR SG failure consequences, which include water-sodium contact, is another reason. Understanding its failure mechanisms is important for the development of its prognostic model. Based on our literature review and physics-based analysis, we concluded that creep would be a dominant degradation mode of SFR SGs due to SFR’s high-temperature and high-pressure environment. Thus, creep is the focus of the prognostic model. Various other failure modes were also investigated in this study. The mechanical fatigue due to flow-induced vibration is usually observed in early developmental phases and would not be an important issue during normal operation. The thermal fatigue due to thermal stripping is occasionally observed in other components in SFRs but does not affect SG integrity. Pure water stress corrosive crack, fretting, and so on are commonly observed in LWR SGs but are significantly less important in SFR SGs because of the high temperatures, high pressure differences, and chemical properties of liquid sodium. Based on these investigations, a prognostic model focusing on creep failures was developed. It estimates the failure probability profile by sampling the Larson-Miller parameter (LMP) and temperature and associated uncertainties through Monte Carlo methods. Two case studies were presented. The first one demonstrated the model’s capability to calculate the failure probability for a new specimen within a given time. If the tube is working under temperatures of 500C ± 3 and pressures of 15.2 MPa, which leads to LMP of 20,100 ± 50, the failure probabilities within 50, 70, and 90 years are approximately 0.1 %, 3.2 %, and 17.5 %. The second demonstrated how adjusting the workload can help to protect the integrity of the component. For an old tube reaching 99 % of its lifespan, continuing to run at temperatures of 500C ± 3 and LMP of 20,100 ± 50 leads to a failure probability of about 29.0 % within a year. If the temperature is reduced by 5C, the failure probability can be reduced to 2.5 %, and, if the pressure is also reduced such that the LMP is increased by 100, the failure probability can further be reduced to 0.12 %.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary Plan to Inform Testing of a Heat Exchanger Test Article

This report presents a preliminary plan to guide the qualification testing of advanced heat exchanger (HX) components for nuclear-to-industrial heat transfer applications. The objective is to establish a defensible, physics-based methodology that integrates computational modeling, targeted experimentation, and in-service inspection considerations to demonstrate component performance and reliability under representative reactor conditions. The analysis identifies Sodium-cooled Fast Reactor (SFR) and High-Temperature Gas-cooled Reactor (HTGR) systems as reference configurations in terms of temperature, pressure, and chemical environment. Within these operating envelopes, dominant degradation mechanisms— including creep–fatigue interaction, flow-induced vibration, corrosion, and diffusion-bond deterioration—were evaluated to define test requirements. A comprehensive computationalexperimental framework is proposed to support life prediction and qualification activities. The framework couples high-fidelity structural-mechanics, thermal-hydraulic, and fluid-structure interaction models with accelerated degradation testing to produce a traceable linkage between microstructural evolution, mechanical performance, and remaining useful life (RUL). The approach adheres to established Verification, Validation, and Uncertainty Quantification (VVUQ) standards (ASME V&V 10/20; NUREG-2152) and incorporates a digital-twin architecture for continuous model refinement through data assimilation. The plan further outlines testing methodologies, including pre-test analyses, test-loop design parameters, and sensor placement strategies that maximize information yield while maintaining mechanistic fidelity. Complementary sections describe in-service inspection (ISI), on-line monitoring (OLM), and structural-health-monitoring (SHM) techniques applicable to compact HX geometries typical of advanced reactors. Collectively, these activities establish the technical foundation for demonstrating 40-60-year equivalent service life of advanced heat exchangers in support of the U.S. Department of Energy’s Advanced Reactor and Integrated Energy Systems programs. The forthcoming phase will execute the defined pre-test analyses, initiate hardware fabrication, and implement the integrated testing campaign to validate the proposed qualification methodology.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Demonstration and Feasibility Analyses of Using the Dual-Purpose Canister Drain Pipe to Support the Filling Process

This work documents experiments that are being used to determine the feasibility of filling dual-purpose canisters (DPCs) using the existing drain pipe. Mercury was identified as a surrogate filler for the initial experiments. Oak Ridge National Laboratory’s Target Test Facility (TTF), which is a full-scale Spallation Neutron Source (SNS) prototypical mercury loop, is being used for the planned pipe experiments using mercury. The pipe experiments were divided into two phases to provide a separate effects approach to the problem and to allow for development of system scalability. The first phase included taking strain measurements in a short length pipe, as well as measurements of flow-induced vibration. The second phase consists of the design and construction of a separated mercury flow loop capable of hosting exchangeable test sections and more localized instrumentation. Data acquisition of Phase I was performed during this work and is presented in the form of strain measurements and vibration frequency.

Dominguez-Ontiveros, Elvis↗

High fidelity simulation and validation of crossflow through a tube bundle and the onset of vibration

Flow induced vibrations can be detrimental to all manner of engineering applications with fluid flow. Heat exchangers with bundles of thin tubes experiencing a crossflow are especially susceptible to the unexpected onset of vibration. Heat-exchanger design necessarily involves extensive modeling and testing to ensure that significant vibrations cannot develop for any expected flow conditions. A properly validated numerical simulation can work in conjunction with physical experiments to identify problematic vibrations and allow for rapid iteration of design at relatively low expense. A high-fidelity fluid–structure interaction code has been developed by fully coupling CFD LES/DNS code Nek5000 and CSM code Diablo. The coupled code is used to simulate crossflow through a tube bundle in a geometry recreated after a physical experiment. Validation against this experiment involves comparing the amplitude and frequency spectrum for three different flow velocities. The velocities compared straddle the onset of large magnitude vibrations. The simulation accurately captures the onset of the vibrations with a marginally lower predicted frequency of vibration. When the onset velocity is compensated for the difference in natural frequency, the simulation results closely match the experiment. Finally, the continuous nature of the simulation measurements helps illustrate the fluid mechanics behind the pin motion and reveals the front to back propagation of the vibrations as the fluid velocity increases.

42 ENGINEERING↗

High Fidelity Simulation and Validation of Crossflow through a Tube Bundle and the Onset of Vibration

Flow induced vibrations can be detrimental to all manner of engineering applications with fluid flow. Heat exchangers with bundles of thin tubes experiencing a crossflow are especially susceptible to the unexpected onset of vibration. Heat-exchanger design necessarily involves extensive modeling and testing to ensure that significant vibrations cannot develop for any expected flow conditions. A properly validated numerical simulation can work in conjunction with physical experiments to identify problematic vibrations and allow for rapid iteration of design at relatively low expense. A high-fidelity fluid-structure interaction code has been developed by fully coupling CFD LES/DNS code Nek5000 and CSM code Diablo. The coupled code is used to simulate crossflow through a tube bundle in a geometry recreated after a physical experiment. Validation against this experiment involves comparing the amplitude and frequency spectrum for three different flow velocities. The velocities compared straddle the onset of large magnitude vibrations. The simulation accurately captures the onset of the vibrations with a marginally lower predicted frequency of vibration. When the onset velocity is compensated for the difference in natural frequency, the simulation results closely match the experiment. The continuous nature of the simulation measurements helps illustrate the fluid mechanics behind the pin motion and reveals the front to back propagation of the vibrations as the fluid velocity increases.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hydrokinetic Energy Conversion by Flow-Induced Oscillation of Two Tandem Cylinders of Different Stiffness

Abstract The vortex-induced vibration for aquatic clean energy (VIVACE) converter harnesses hydrokinetic energy by enhancing flow-induced oscillations (FIOs) of elastically supported rigid cylinders in a river, tide, or ocean current. The harnessing power depends on the intensity of the oscillation, which is a consequence of the flow–structure interaction. The inflow condition for the downstream (second) cylinder is slowed down and perturbed by the upstream (first) cylinder, due to the shielding effect. Therefore, the optimal structural parameters, i.e., stiffness and damping ratio, for the second cylinder may be different from the first cylinder, in terms of energy harnessing. To improve the performance of the VIVACE converter, a series of experiments are conducted in a recirculating water channel, with various stiffness combinations of two cylinders in tandem. Results show that the stiffness of the second cylinder, K2, does not affect the energy harnessing power in vortex-induced vibration (VIV) occurring at low speeds, because the oscillation of the downstream cylinder in this velocity range is completely dominated by the wake of the upstream cylinder. K2 has a great influence on the harnessing power at higher velocities in the transition region from VIV to galloping and in galloping. Changing K2 onsets and enhances galloping at lower flow velocity and harnesses up to 110% more energy than the case of K1 = K2.

Engineering↗

Hydrokinetic energy harvesting from slow currents using flow-induced oscillations

To harness marine hydrokinetic energy from slow flows, which constitute the majority of currents, tides, and rivers, new Passive Turbulence Control (PTC), consisting of large turbulence stimulators, is tested experimentally on circular cylinders on springs. Here, this study experimentally investigates the effect of PTC on the onset of Flow-Induced Oscillations (FIO) and particularly the relative onset of Vortex-Induced Vibrations (VIV) and galloping. Experiments are conducted in the Low Turbulence Free Surface Water Channel, University of Michigan. Fixed are: mass ratio m* = 1.48, aspect ratio l/D = 10.29, and total damping ratio ζ = 0.04. Parameters are: cylinder diameter D, spring stiffness K, PTC location and height, and flow speed U$\in$[0.36 m/s-1.45 m/s]. Placing the leading edge of PTC at 40–60° induces high amplitude FIO while placement at 10–20° suppresses FIO. As PTC height increases, VIV and galloping initiate earlier and exhibit higher amplitude with a steeper slope. Lower spring stiffness initiates VIV earlier by reducing the oscillator natural frequency in water. Even though large PTC maintained its effectiveness in initiating galloping early, it has no effect on the earlier initiation of VIV, which starts at a nearly fixed reduced velocity. Lower spring stiffness and large PTC enable power generation at low current speed (0.2 m/s).

16 TIDAL AND WAVE POWER↗

Experimental and numerical study of the shielding effect of two tandem rough cylinders in flow-induce oscillation

The shielding effect of the downstream cylinder in flow induced oscillation (FIO) of two cylinders arranged in tandem is studied experimentally and numerically at Reynolds number 30,000 to 120,000. Both cylinders are in one degree-of-freedom, transverse-oscillations, and have turbulence stimulation in the form of selective surface roughness to expand FIO beyond vortex-induced vibration (VIV) into galloping. Shielding of the downstream cylinder has a negative effect on harnessing hydrokinetic energy. Further, to study its effect and mechanics, selective cases are studied both numerically and experimentally and discussed to demonstrate the shielding effect on the downstream cylinder and understand its cause. The main conclusions are: (1) The shielding effect for the downstream cylinder shows a strong relation to the damping ratio. As the damping ratio increases, the shielding effect is mitigated. Additionally, the oscillation of the rear cylinder becomes stable and shows stable frequency. (2) In the VIV region, as the stiffness and natural frequency increase, the shielding effect decreases substantially. (3) In the VIV region, the vorticity of the vortices shedding from both the upper and the lower sides of the downstream cylinder does not accumulate enough due to the attraction by the vortices shed from the upstream cylinder, thus resulting in partial suppression of the oscillation on the downstream cylinder. (4) In the galloping region, the shielding effect for the downstream cylinder depends on whether the vorticity near the downstream cylinder is strengthened by the vortices generated by the shear layers of the upstream cylinder or weakened.

42 ENGINEERING↗

Hydrokinetic energy conversion using flow induced oscillations of single-cylinder with large passive turbulence control

Various types of flow-induced oscillations (FIOs) have been implemented in development of marine hydrokinetic (MHK) energy converters. With passive turbulence control (PTC), energy harvesting starts at a flow speed of about 0.5 m/s. However, there is worldwide MHK energy available in even slower currents. In the present study, the effect of damping on FIO and power extraction is investigated for a converter with large turbulence stimulation (PTC) consisting of straight strips with a height of 15% of the cylinder diameter and placed symmetrically on the cylinder surface. The oscillating amplitude decreases, as the damping ratio increases, with unchanged sinusoidal pattern of the displacement time-history. The frequency ratio is also affected by damping especially in the VIV initial branch and transition region between VIV and galloping. An important flow characteristic of the large-PTC cylinder is that a recirculation region is formed behind the PTC, causing appreciable disturbance to the flow past the cylinder. Power can be harvested in the whole FIO range and the harnessed power maximum appears at the largest inflow velocity tested. However, the optimum of harnessing efficiency is located at the beginning of the VIV upper branch. The gap between VIV and galloping is bridged when large PTC is used, eliminating the drop in power and efficiency even at higher damping, which would be a weakness of regular-PTC cylinder for energy harvesting. Finally, the mechanism behind the variation of harnessing efficiency with inflow velocity and damping ratio is revealed, and the optimality criterion for the converter design is discussed.

16 TIDAL AND WAVE POWER↗

Bio-Inspired adaptive damping in hydrokinetic energy harnessing using flow-induced oscillations

A hydrokinetic energy converter using Flow Induced Oscillations (FIOs) of a one-degree-of-freedom cylinder-oscillator, with nonlinear adaptive damping and linear spring stiffness, is introduced and studied experimentally. Comparison to a linear-oscillator in FIO shows that this new converter, with velocity-proportional damping coefficient, is more effective in galloping, where both flow and cylinder speeds are higher. It also impacts VIV, since the converter is no longer restricted by fixed damping, which results either in ceasing motion due to excessive damping, or in low harnessed energy due to insufficient damping. The impact is most profound in the VIV to galloping transition where adaptive damping prevents shutting down of hydrokinetic energy conversion. Damping-to-velocity rate, linear spring-stiffness, and flow-velocity are the experimental parameters with Reynolds number 30,000 ≤ Re ≤ 120,000. Here, experimental results for amplitude response, frequency response, energy harvesting, efficiency and instantaneous energy of the converter are presented and discussed. The main conclusions are: (1) The nonlinear, adaptive, velocity-proportional damping coefficient increases the harnessed power. (2) The operational range of flow velocities increases. (3) At lower flow speeds, the adaptive damping stabilizes the unstable oscillations typically occurring in this region. (4) At higher flow speeds, adaptive damping results in higher harnessed power than constant damping, thus, better emulating passively a corresponding, natural, active motion by fish. (5) Increase of 51%–95% in converted power by the nonlinear oscillator compared to linear oscillator has been measured. (6) The adaptive damping converter reaches a plateau in harnessed efficiency at high flow velocity (fully developed galloping).

13 HYDRO ENERGY↗

Flow-induced oscillation patterns for two tandem cylinders with turbulence stimulation and variable stiffness and damping

Herein, the oscillation patterns of two 1-DOF cylinder oscillators, undergoing VIV and galloping, are investigated in a free surface water channel for 3.2 × 104 ≤ Re ≤ 1.2 × 10 5 . The cylinders are arranged in tandem and supported by springs for a range of different spring stiffness and damping parameters. The efficiency of a current energy converter (CEC), based on flow-induced oscillation (FIO) of multiple cylinders in tandem, is critically related to the cylinder oscillation patterns. Due to the limited number of studies on the FIO for multiple cylindrical or prismatic bodies, their oscillation patterns have neither been identified nor classified. The surfaces of the cylinders are modified by turbulence stimulation to enhance FIO. Three different center-to-center spacing, five stiffness, and six damping ratios, for a total of 90 sets of experiments were conducted. The current velocity range is from 0.34 m/s to 1.32 m/s. From more than 2000 tests, five major patterns, nine sub-patterns are identified and classified. The patterns are defined based on the amplitudes, frequencies and the phase angle differences between the two cylinders. The characteristics and mechanics of each oscillation pattern are explored and explained from the perspective of fluid-structure interaction (FSI). By systematically varying the parameters, the underlying hydrodynamic mechanisms, including the coupling level between vortices and cylinders, the shielding effect, the wake effect, and the stability states are revealed. Few preliminary observations on the connection between oscillation pattern and harnessed power by the tandem cylinders are reported.

42 ENGINEERING↗