Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluctuation diagnostic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Feasibility Study: High-k Temperature (HiT) Fluctuation Diagnostic

The objective of the proposed research was to explore the feasibility of making measurements of high-k (electron-scale, ETG-relevant) electron temperature fluctuations in the core plasma of tokamaks and stellarators. We found that soft X-ray imaging combined with our novel pseudolocal tomographic algorithm enables local measurements of low-k (ion-scale, ITG/TEM and KBM/MTM relevant) electron temperature fluctuations in spherical tokamaks. The design parameters needed to consider deploying this new diagnostic are presented, and predictions for what the diagnostic would measure in L-mode and H-mode plasmas at NSTX-U, a high performance spherical tokamak in the USA, suggest that the new diagnostic can be used to study turbulence and transport over a wide range of plasma parameters, such as collisionality and plasma beta.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterizing core and edge turbulence regimes with fluctuation imaging diagnostics in Wendelstein 7-X

Two density fluctuation imaging systems, phase contrast imaging (PCI) and gas puff imaging (GPI) measure spatially resolved density fluctuations with high time resolution throughout the core plasma (PCI) and in the scrape-off layer (GPI) of the Wendelstein 7-X (W7-X) stellarator. Both systems combined give a comprehensive overview of overall fluctuation levels, spectral properties such as their distribution in frequency and wavenumber space as well as their spatial distribution. These tools are used to assess changes in density turbulence in three representative discharges that transition into stable divertor detachment by different strategies (impurity seeding, density ramping and power starvation). Several general trends are identified when the radiated power fraction is systematically increased: In the plasma edge, the line emission observed by GPI shifts radially inward with a drop in electron temperature, and normalized intensity fluctuation profiles follow this inward shift. Skewness and kurtosis of these edge fluctuations are reduced, indicating a reduction of large intermittent transport events, and poloidal phase velocities decrease in magnitude. These observations are consistent with a reduced power input into the plasma edge and a general reduction of turbulent activity. Core density fluctuation levels remain nearly constant in the impurity seeding scenario, indicating that detachment does not significantly impact turbulence there. However, a strong reduction in the dominant outboard fluctuation phase velocity is observed that deviates from the previous interpretation of neoclassical radial electric field changes, showing that the core plasma is not completely unaffected. In the density ramp and power starvation scenarios, undesirable and irregular large-scale events arise clearly in both diagnostic systems as the radiative fraction is increased. Impurity seeding therefore seems to be a promising strategy on W7-X to achieve detachment without significantly altering core turbulence, especially when targeting a specific operating point in core density and heating power.

Wendelstein 7-X↗

Machine Learning for Real-time Fusion Plasma Behavior Prediction and Manipulation (Final Report)

The goal of this project is to implement real-time analysis of 2D Beam Emission Spectroscopy (BES) data to predict and control transient and high-bandwidth events at DIII-D. In essence, we wish to bring high-bandwidth fluctuation diagnostics into the realm of real-time measurements and control. The BES ML models will necessarily be deep neural networks (DNN) with a “data flow” architecture for compatibility with high-throughput, low-latency evaluation on a field-programmable gate array (FPGA) or other emerging processor technologies. The real-time output will be fed to the plasma control system (PCS) for real-time control tasks, specifically for ELM control and avoidance and for QH-mode access and sustainment. We anticipate that the real-time analysis of fluctuation diagnostics will create new enabling technologies to predict and control transient events such as confinement mode transitions, edge-localized modes, Alfven eigenmode events, and disruptions. The proposed research is aligned with ITER research needs and DIII-D programmatic goals. For instance, the prediction and avoidance of ELM events is critical for ITER machine safety. Also, H-mode access with RMP ELM suppression in ITER is an active research area due to high separatrix density, narrow SOL width, and elevated LH transition power threshold.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of Local Electric Field Turbulence in Magnetically Confined Plasmas (Final Report)

This final report describes the development of high-bandwidth plasma fluctuation diagnostics, encompassing the design and implementation of Beam Emission Spectroscopy systems on several fusion experiments such as TFTR, DIII-D and NSTX, the advancement of Alpha particle and Ultrafast Charge-Exchange Recombination Spectroscopy, and the creation of advanced spectrometers for localized studies of electric and magnetic field fluctuations based on the Motional Stark Effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

System-on-chip upgrade of millimeter-wave imaging diagnostics for fusion plasma

Monolithic, millimeter wave “system-on-chip” technology has been employed in chip heterodyne radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature and fluctuation diagnostics. The system employs 20 horn-waveguide receiver modules each with customized W-band (75–110 GHz) monolithic microwave integrated circuit chips comprising a W-band low noise amplifier, a balanced mixer, a ×2 local oscillator (LO) frequency doubler, and two intermediate frequency amplifier stages in each module. Compared to previous quasi-optical ECEI arrays with Schottky mixer diodes mounted on planar antennas, the upgraded W-band array exhibits >30 dB additional gain and 20× improvement in noise temperature; an internal eight times multiplier chain is used to provide LO coupling, thereby eliminating the need for quasi-optical coupling. The horn-waveguide shielding housing avoids out-of-band noise interference on each module. The upgraded ECEI system plays an important role for absolute electron temperature and fluctuation measurements for edge and core region transport physics studies. An F-band receiver chip (up to 140 GHz) is under development for additional fusion facilities with a higher toroidal magnetic field. Visualization diagnostics provide multi-scale and multi-dimensional data in plasma profile evolution. Finally, a significant aspect of imaging measurement is focusing on artificial intelligence for science applications.

47 OTHER INSTRUMENTATION↗

Strongly intermittent far scrape-off layer fluctuations in Alcator C-Mod plasmas close to the empirical discharge density limit

Abstract Intermittent plasma fluctuations in the boundary region of the Alcator C-Mod device were comprehensively investigated using data time-series from gas puff imaging and mirror Langmuir probe diagnostics. Fluctuations were sampled during stationary plasma conditions in ohmically heated, lower single null diverted configurations with scans in both line-averaged density and plasma current, with Greenwald density fractions up to 0.85. Utilizing a stochastic model, we describe the plasma fluctuations as a super-position of uncorrelated pulses, with large-amplitude events corresponding to blob-like filaments moving through the scrape-off layer (SOL). A deconvolution method is used to estimate the pulse arrival times and amplitudes. The analysis reveals a significant increase of pulse amplitudes and waiting times as the line-averaged density approaches the empirical discharge density limit. Broadened and flattened average radial profiles are thus accompanied by strongly intermittent and large-amplitude fluctuations. Although these filaments are arriving less frequently at high line-averaged densities, we show that there are significant increases in radial far-SOL particle and heat fluxes which will further enhance plasma–wall interactions. The stochastic model has been used as a framework for study of the scalings in the intermittency parameter, flux and mean amplitude and waiting times, and is being used to inform predictive capability for the effects of filamentary transport as a function of Greenwald fraction.

Physics↗

System-on-Chip approach microwave diagnostics development for burning plasma

System-on-chip (SoC) millimeter wave integrated circuit technology has been developed and employed in chip heterodyne radiometers in Electron Cyclotron Emission Imaging (ECEI) and Microwave Imaging Reflectometer (MIR) on the DIII-D tokamak for 2D electron temperature and density fluctuation diagnostics. The W-band (75-110 GHz) ECEI system has been employed with 20 poloidal horn receiver modules with customized monolithic integrated circuit chips and internal local oscillator coupling path. The new SoC approach demonstrates > 30 dB additional gain on the receiver and 95% electronics noise suppression compared to the previous Schottky diode mixer array . An F-band (110-140 GHz) receiver chip has been developed to measure MHD and turbulence behavior on the DIII-D high-field side, such as Alfven eigenmodes. Furthermore, it can image pedestal structure evolution on fusion facilities with stronger magnetic fields, such as ASDEX-U, EAST, HL-2M, and LHD. The F-band chip performance has been tested in the laboratory. Also, V-band (55-75 GHz) transmitter and receiver modules (55-75 GHz) have been developed for DIII-D and NSTX-U Furthermore, microwave Imaging Reflectometer (MIR) application suitability for 2D density fluctuation imaging on the pedestal region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ELM-free enhanced D α H-mode with near zero NBI torque injection in DIII-D tokamak

Enhanced D α H-mode (EDA H-mode), an ELM-free H-mode regime, and the concomitant quasi-coherent mode (QCM) are explored in neutral beam heated, lower single null plasmas with near zero external torque injection. This regime exhibits good energy confinement (H 98y2 ~ 1) with β N ~ 2, high density, regime access at low input power, and no ELMs. New time–resolved measurements of electron and ion density, temperature, plasma rotation, and radial electric field as well as turbulence, flows, thermal and particle transport, and linear instability calculations examining the dynamics of the QCM are presented. Measurements using multiple fluctuation diagnostics reveal the QCM to be a separatrix spanning mode, peaking just inside the separatrix, existing in a wide range of k ⊥ ρ s ~ 0.1–1.2 with multiple harmonics, and propagating with a very small phase velocity in the plasma frame, where k ⊥ is the binormal wavenumber and ρ s is the ion sound radius. Linear gyrokinetic simulations of this EDA H-mode discharge with CGYRO indicate that the trapped electron mode (TEM) and electron temperature gradient mode are the dominant instabilities in the radial region where QCM is also unstable. Qualitative analysis indicates that the properties of TEM are consistent with the experimentally observed characteristics of the QCM. These similarities suggest that the QCM is consistent with a TEM instability existing in the edge region of the EDA H-mode plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast wave interferometer for ion density measurement on DIII-D

=A fast wave interferometer (FWI), which can measure ion mass density, has been developed on DIII-D for its use on future fusion reactors, as well as for the study of ion behavior in current plasma devices. The frequency of the fast waves used for the FWI is around 60 MHz, and require antennas and coaxial cables or waveguides, which, unlike traditional mirror-based optical interferometers, are less susceptible to neutron/gamma-ray radiation and are relatively immune to impurity deposition and erosion as well as alignment issues. The bulk ion density evaluated using FWI show good agreement with that derived from CO 2 interferometry within about 15%. When the ion mass density measurement by FWI is combined with an electron density measurement from CO 2 interferometry, Z eff measurements are also enabled and are in agreement with those from visible Bremsstrahlung measurements. Additionally, large-bandwidth FWI measurements clearly resolve 10–100 kHz coherent modes and demonstrate its potential as a core fluctuation diagnostic, sensitive to both magnetic and ion density perturbations.

Instruments & Instrumentation↗

Polarimetry-Interferometry Diagnostic for Magnetic Field and Magnetic Fluctuation Measurements in High-Performance and Long-Pulse Tokamaks (Final Report)

In this grant, we executed a multi-year plan to develop an advanced Faraday-effect polarimeter-interferometer system to address both fluctuation and equilibrium diagnostic needs by providing a measurement of the plasma internal magnetic field fluctuations (including non-axisymmetric 3-D perturbations) and plasma vertical position. This diagnostic included both fast time response and low phase noise so that both the temporal dynamics of equilibrium quantities as well as high-frequency electromagnetic fluctuations could be measured simultaneously, adding new and unique measurement capabilities for the core of high-temperature plasmas. The combined polarimeter-interferometer diagnostic development was applied primarily to the tokamak magnetic configuration, focusing on high-performance regimes including H-mode, reversed shear advanced tokamak scenarios, and non-inductive current drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feasibility study of a high spatial and time resolution beam emission spectroscopy diagnostic for localized density fluctuation measurements in Lithium Tokamak eXperiment-β (LTX-β)

Trapped electron mode (TEM) is the main source of turbulence predicted for the unique operation regime of a flat temperature profile under low-recycling conditions in the LTX-β tokamak, while ion temperature gradient driven turbulence may also occur with gas fueling from the edge. To investigate mainly TEM scale density fluctuations, a high spatial and time resolution 2D beam emission spectroscopy (BES) diagnostic is being developed. Apart from spatially localized density turbulence measurement, BES can provide turbulence flow and flow shear dynamics. This BES system will be realized using an avalanche photodiode-based camera and narrow band interference filter. The system can acquire data at 2 MHz. Simulations with the Simulation of Spectra (SOS) code indicate that a high signal to noise ratio can be achieved with the proposed system. This will enable sampling the density fluctuations at this high time resolution. Finally, the design considerations and system optimization using the SOS code are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase Contrast Imaging Diagnostic on DIII-D (1994-2007); Phase Contrast Imaging Diagnostic on DIII-D and Alcator C-Mod (2007-2010); Experimental Study of Waves, Turbulence and Transport, and Model Validation with Phase Contrast Imaging on DIII-D and Alcator C-Mod (2010-2012); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Measuring High-k Turbulence and Alfven modes (2021-2016); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Full Multi-Scale Measurements (2016-2020) (Final Report)

This report describes the first twenty-five years of development and use of the Phase Contrast Imaging (PCI) diagnostic for measuring plasma fluctuations on the DIII–D tokamak. One of the key challenges in moving tokamak technology forward to the stage of a nuclear reactor remains understanding how energy and particles are transported across the magnetic field by the action of turbulence and waves, and PCI provides a highly flexible and capable measurement of these fluctuations. The PCI diagnostic uses a laser beam to probe the plasma and optical filtering to produce an amplitude variation on a linear detector array which provides an image of the density waves in the plasma. The PCI covers an exceptional range in frequency and wavelength of the measured fluctuations, allowing observation of plasma-sized magnetohydrodynamic (MHD) modes and ion- and electron-scale turbulence. Modulation of the beam amplitude allows measurement of radio frequency (RF) waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental characterization of turbulence properties in negative triangularity DIII-D plasmas

Negative Triangularity (NT) plasmas have demonstrated robustly ELM-free high-performance operation and provide a unique testbed to study how plasma shaping affects turbulent transport. The Beam Emission Spectroscopy (BES) diagnostic provides localized 2D measurements of low-k ($k_{\theta} \rho_s < 1$) density fluctuations. In a sweep of upper triangularity at fixed power, H-mode access is suppressed and an NT-edge is observed. The turbulence amplitude ($\tilde{n}/n$) is shown to decrease by $\sim50\%$ for $\rho<0.9$ in the NT-edge phase as compared to the H-mode phase. Additionally, low-velocity edge modes below 70 kHz are suppressed by triangularity and the dominant mode propagating in the electron diamagnetic direction is seen to broaden in wavenumber space in the NT-edge phase. In a strong NT plasma ($\delta_{avg}\sim-0.5$), low amplitude modes ($\tilde{n}/n <0.5\%$) propagating in the ion-diamagnetic direction with radially-poloidally symmetric eddy structure are identified for $\rho \sim 0.65-0.83$ consistent with Ion Temperature Gradient (ITG) turbulence. Modes consistent with Trapped Electron Mode (TEM) turbulence are observed propagating in the electron-diamagnetic direction for $\rho\gtrsim0.83$ with poloidally extended eddy structure and reduced amplitudes observed at the separatrix. The turbulence properties presented in this paper help validate our understanding of NT turbulence and help explain the improved confinement and unique edge features of NT plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative comparisons of electron-scale turbulence measurements in NSTX via synthetic diagnostics for high-k scattering.

Two synthetic diagnostics are implemented for the high-k scattering system in NSTX [D. R. Smith, E. Mazzucato, W. Lee, H. K. Park, C. W. Domier, and N. C. Luhmann Jr., Rev. Sci. Instrum., 79, 123501 (2008)] allowing direct comparisons between synthetic and experimentally detected frequency and wavenumber spectra of electron-scale turbulence fluctuations. Synthetic diagnostics were formulated in real-space and in wavenumber space, and were deployed to realistic electron-scale simulations carried out with the GYRO code [J. Candy and R. E. Waltz, J. Comput. Phys. 186 (2003) 545]. A highly unstable ETG regime (electron temperature gradient mode) in a modest beta NSTX NBI-heated H-mode discharge was chosen for the analysis. Mapping the measured wavenumbers to field aligned coordinates showed that the high-k system is sensitive to fluctuations that are closer to the spectral peak in the density fluctuation wavenumber spectrum (streamers) than originally predicted. Analysis of synthetic spectra show that the frequency response of the detected fluctuations is dominated by Doppler shift and insensitive to the turbulence drive. The shape of the high-k density fluctuation wavenumber spectrum is sensitive to the ETG turbulence drive conditions, and can be reproduced in a sensitivity scan of the most pertinent turbulent drive terms in the simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

W-band system-on-chip electron cyclotron emission imaging system on DIII-D

Monolithic, millimeter wave “system-on-chip” (SoC) technology has been employed in heterodyne receiver integrated circuit radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature profile and fluctuation evolution diagnostics. Here, a prototype module operating in E-band (72-80 GHz) was first employed in a 2 x 10 element array that demonstrated significant improvements over the previous quasi-optical Schottky diode mixer arrays during the 2018 operational campaign of the DIII-D tokamak. For compatibility with International Thermonuclear Experimental Reactor (ITER) relevant scenarios on DIII-D, the SoC ECEI system was upgraded with 20 horn-waveguide receiver modules. Each individual module contains a University of California at Davis designed W-band (75 -110 GHz) receiver die that integrates a broadband low noise amplifier (LNA), a double balanced down-converting mixer, and a x4 multiplier on the local oscillator (LO) chain. A x2 multiplier and two IF amplifiers are packaged and selected to further boost the signal strength as well as downconvert the signal frequency. The upgraded W-band array exhibits > 30 dB additional gain and 20x improvement in noise temperature comparing with the previous Schottky diode radio frequency (RF) mixer input systems; an internal 8 times multiplier chain is used to bring down the LO frequency below 12 GHz, thereby obviating the need for a large aperture for quasi-optical LO coupling and replacing it with coaxial connectors. The horn-waveguide shielding housing avoids out-of-band noise interference on each individual module. The upgraded ECEI system plays an important role for absolute electron temperature evolution and fluctuation measurements for edge and core region transport physics studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of microwave broadband CMOS transmitter and receiver circuits for MIR and ECEI plasma diagnostics

To efficiently determine the plasma electron density fluctuations using the MIR diagnostic technique, a 55–75 GHz 65 nm-CMOS transmitter has been developed where four separate intermediate frequency (IF) signals are up-converted, amplified, and then combined to generate an 8-tone RF output; a broadband 90 nm-CMOS receiver has also been constructed, which consists of an RF-low noise amplifier (LNA), mixer, and IF amplifier. The circuits and their corresponding modules will soon be deployed on the DIII-D and NSTX-U fusion devices. A 110–140 GHz 65 nm-CMOS receiver has also been designed, which is suitable for measuring the deep-core temperature fluctuations in the DIII-D tokamak using the electron cyclotron emission imaging diagnostic system. In addition to the RF-LNA/balun, mixer, and IF amplifier, an LO balun/tripler and driving amplifier are now included in this highly integrated circuit chip. By adopting the microwave and millimeterwave system-on-chip concept in the front-end system design, this paper demonstrates that compact transmitter and receiver modules can be easily built, which, in turn, facilitates array implementation and maintenance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗