Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluorescence lifetime imaging microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Spatially resolved charge-transfer kinetics at the quantum dot–microbe interface using fluorescence lifetime imaging microscopy

Integrating the optoelectronic properties of quantum dots (QDs) with biological enzymatic systems to form microbe-semiconductor biohybrids offers promising prospects for both solar-to-chemical conversion and light-modulated biochemical processes. Developing these nano–bio hybrid systems necessitates a deep understanding of charge-transfer dynamics at the nano–bio interface. Photoexcited carrier transfer from QDs to microbes is driven by complex interactions, with emerging insights into the relevant thermodynamic and kinetic factors. The heterogeneities of both microbes and QD ensembles pose significant challenges in mechanistic understanding, which is critical for designing advanced nano–bio hybrids. We used fluorescence lifetime imaging microscopy to analyze charge transfer between a CdSe QD film andShewanella oneidensismicrobes. We correlated the spatiotemporal fluorescence data with an analytical model. Our analysis revealed two distinct distributions of QD de-excitation pathways. The characteristics of these distributions: 1) a faster transfer rate ( k ¯ E T 1 = 1.5 10 9 s - 1 ), with a lower acceptor number ( N ¯ a 1 = 0.03 ) and 2) a slower transfer rate ( k ¯ E T 2 = 4.1 10 8 s - 1 ) with a higher acceptor number ( N ¯ a 2 = 0.18 ). We assign these distributions to the indirect and direct electron transfer mechanisms, respectively. Our findings demonstrate how spectroscopic imaging can uncover fundamental electron transfer mechanisms at complex interfaces, offering valuable design principles for future nano–bio hybrids.

Science & Technology - Other Topics↗

Development of high throughput light-sheet fluorescence lifetime imaging microscopy for 3D functional imaging of metabolic pathways in plant and microorganisms (Final Technical Report)

This research program will enable new biochemical contrast in the nanosecond lifetime domain through use of the recently demonstrated electro-optic fluorescence lifetime imaging technique (EO-FLIM) for wide-field lifetime imaging. The Stanford/Stanford Linear Accelerator Center multidisciplinary collaboration -- physics, applied physics, and structural biology -- will develop a light-sheet fluorescence lifetime imaging microscope for functional studies of microbial and plant metabolic pathways and dynamic interactions between plants and microorganisms in the rhizosphere. The proposed approach overcomes the imaging time bottleneck associated with existing fluorescence lifetime imaging methods. Initial demonstrations have shown a factor of 100,000 improvement in photon throughput compared to existing methods. High photon efficiency allowed the first wide-field fluorescence lifetime imaging of single molecules. Recent work has improved the technique’s repetition rate to enable compatibility with mode-locked lasers and demonstrated the combination of wide-field fluorescence lifetime imaging with super-resolution localization microscopy, observations of single molecule dynamics, and observation of donor lifetime quenching in single-molecule imaging. These results were achieved on standard camera sensors and would not have been possible with other wide-field approaches. The throughput and photon economy of the EO-FLIM method enables new BER-relevant imaging opportunities. In particular, scanned single- and two-photon light-sheet excitation will be used to achieve volumetric imaging with time-domain contrast.

47 OTHER INSTRUMENTATION↗

Super‐Resolution Lifetime Imaging of Single Molecules Near Gold Bowtie Nanoparticles

Interactions between light and matter serve as the basis of many technologies, but the quality of these devices is inherently limited by the optical properties of their constituents. Plasmonic nanoparticles are a highly versatile and tunable platform for the enhancement of such optical properties. However, the near-field nature of these effects has made thorough study and understanding of these mechanisms difficult. In this work, we introduce a fully confocal technique combining photoswitching super-resolution microscopy with fluorescence lifetime imaging microscopy to study single-molecule decay rate enhancement. We demonstrate that the technique combines a spatial resolution better than 20 nm, and a 16 ps temporal resolution. Simultaneously, an autocorrelation measurement is also performed to confirm that the data indeed originates from single molecules. This work provides insight into the various mechanisms of plasmon-enhanced emission, and allows the study of the correlation between emission intensity and lifetime enhancement. This complicated relationship is shown to be dependent upon the relative influence of various radiative and nonradiative decay pathways. Here, we provide a platform for further study of emission mislocalization, the position-dependent prominence of different decay pathways, and the direct super-resolved measurement of the local density of states.

36 MATERIALS SCIENCE↗

FLIMJ: An open-source ImageJ toolkit for fluorescence lifetime image data analysis

In the field of fluorescence microscopy, there is continued demand for dynamic technologies that can exploit the complete information from every pixel of an image. One imaging technique with proven ability for yielding additional information from fluorescence imaging is Fluorescence Lifetime Imaging Microscopy (FLIM). FLIM allows for the measurement of how long a fluorophore stays in an excited energy state, and this measurement is affected by changes in its chemical microenvironment, such as proximity to other fluorophores, pH, and hydrophobic regions. This ability to provide information about the microenvironment has made FLIM a powerful tool for cellular imaging studies ranging from metabolic measurement to measuring distances between proteins. The increased use of FLIM has necessitated the development of computational tools for integrating FLIM analysis with image and data processing. To address this need, we have created FLIMJ, an ImageJ plugin and toolkit that allows for easy use and development of extensible image analysis workflows with FLIM data. Built on the FLIMLib decay curve fitting library and the ImageJ Ops framework, FLIMJ offers FLIM fitting routines with seamless integration with many other ImageJ components, and the ability to be extended to create complex FLIM analysis workflows. Building on ImageJ Ops also enables FLIMJ’s routines to be used with Jupyter notebooks and integrate naturally with science-friendly programming in, e.g., Python and Groovy. We show the extensibility of FLIMJ in two analysis scenarios: lifetime-based image segmentation and image colocalization. We also validate the fitting routines by comparing them against industry FLIM analysis standards.

47 OTHER INSTRUMENTATION↗

Hyperdimensional Imaging Contrast Using an Optical Fiber

Fluorescence properties of a molecule can be used to study the structural and functional nature of biological processes. Physical properties, including fluorescence lifetime, emission spectrum, emission polarization, and others, help researchers probe a molecule, produce desired effects, and infer causes and consequences. Correlative imaging techniques such as hyperdimensional imaging microscopy (HDIM) combine the physical properties and biochemical states of a fluorophore. Here we present a fiber-based imaging system that can generate hyper-dimensional contrast by combining multiple fluorescence properties into a single fluorescence lifetime decay curve. Fluorescence lifetime imaging microscopy (FLIM) with controlled excitation polarization and temporally dispersed emission can generate a spectrally coded, polarization-filtered lifetime distribution for a pixel. This HDIM scheme generates a better contrast between different molecules than that from individual techniques. This setup uses only a single detector and is simpler to implement, modular, cost-efficient, and adaptable to any existing FLIM microscope. We present higher contrast data from Arabidopsis thaliana epidermal cells based on intrinsic anthocyanin emission properties under multiphoton excitation. This work lays the foundation for an alternative hyperdimensional imaging system and demonstrates that contrast-based imaging is useful to study cellular heterogeneity in biological samples.

47 OTHER INSTRUMENTATION↗

Carrier gradients and the role of charge selective contacts in lateral heterojunction all back contact perovskite solar cells

Realizing photovoltaic devices that achieve the full potential of the metal halide perovskite material will require improved insight regarding the role of selective contacts and how key interfaces operate when mobile defects are present. However, measuring interface properties in typical device stacks where the perovskite layer is thin and sandwiched between two contacts has been a challenge. Here, we fabricate p-i-n and p-n lateral heterojunctions with nickel oxide/titanium oxide all back contacts, permitting us to employ a comprehensive analysis approach, including ultraviolet and X-ray photoemission spectroscopy (UPS/XPS), angle-resolved X-ray absorption spectroscopy (XAS), Kelvin probe force microscopy (KPFM), surface photovoltage (SPV), hyperspectral imaging (HSI), and time-resolved fluorescence lifetime imaging microscopy (TR-FLIM) to discern the role of selective contacts. Specifically, we tune the selectivity of the contacts, changing the gradient in the carrier concentration across the surface of the active layer, which is connected to carrier extraction at the buried interface, and thus the device functionality.

25 ENERGY STORAGE↗

Radiative lifetime-encoded unicolour security tags using perovskite nanocrystals

Traditional fluorescence-based tags, used for anticounterfeiting, rely on primitive pattern matching and visual identification; additional covert security features such as fluorescent lifetime or pattern masking are advantageous if fraud is to be deterred. Herein, we present an electrohydrodynamically printed unicolour multi-fluorescent-lifetime security tag system composed of lifetime-tunable lead-halide perovskite nanocrystals that can be deciphered with both existing time-correlated single-photon counting fluorescence-lifetime imaging microscopy and a novel time-of-flight prototype. We find that unicolour or matching emission wavelength materials can be prepared through cation-engineering with the partial substitution of formamidinium for ethylenediammonium to generate “hollow” formamidinium lead bromide perovskite nanocrystals; these materials can be successfully printed into fluorescence-lifetime-encoded-quick-read tags that are protected from conventional readers. Furthermore, we also demonstrate that a portable, cost-effective time-of-flight fluorescence-lifetime imaging prototype can also decipher these codes. A single comprehensive approach combining these innovations may be eventually deployed to protect both producers and consumers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self‐Assembly Methods Induce Different Individual‐Polymer‐Block Solvation Responses

An understanding of block-specific responses to stimuli in self-assembled copolymers is essential for the effective design of responsive materials. Here, materials formed from different post-reaction processing methods of the same ROMP block copolymer exhibit different block-specific solvent responses, as characterized in situ by fluorescence lifetime imaging microscopy (FLIM). FLIM data were acquired by tagging the polar or nonpolar block separately with a covalently incorporated viscosity-sensitive fluorescent molecular rotor to measure the changing tightness or looseness of assembly upon changes in solvent composition. Rapid precipitation from an insoluble solvent to form a film results in tighter assembly and less difference in tightness/looseness between the two blocks. Further, it interrupts individual block-solvent response behavior. Both results indicate an apparent disruption of the core–shell assembly. This model from FLIM is further supported by differential scanning calorimetry (DSC) and small-angle X-ray scattering (SAXS) data from isolated solids, which show tighter long-range interactions and more long-range order in these kinetically trapped states. Here, the experiments develop FLIM as a method for pinpointing stimuli-responsive behaviors from different processing methods to individual blocks. Together these outcomes provide a future handle for tailoring solvent-triggered assembly/disassembly behavior.

López, Pía A. [University of California, Irvine, C↗

NIR fluorescence lifetime macroscopic imaging with a time-gated SPAD camera

The performance of SwissSPAD2 (SS2), a large scale, widefield time-gated CMOS SPAD imager developed for fluorescence lifetime imaging, has recently been described in the context of visible range and fluorescence lifetime imaging microscopy (FLIM) of dyes with lifetimes in the 2.5 – 4 ns range. Here, we explore its capabilities in the NIR regime relevant for small animal imaging, where its sensitivity is lower and typical NIR fluorescent dye lifetimes are much shorter (1 ns or less). We carry out this study in a simple macroscopic imaging setup based on a compact NIR picosecond pulsed laser, an engineered diffuser-based illumination optics, and NIR optimized imaging lens suitable for well-plate or small animal imaging. Because laser repetition rates can vary between models, but the synchronization signal frequency accepted by SS2 is fixed to 20 MHz, we first checked that a simple frequency-division scheme enables data recording for different laser repetition rates. Next, we acquired data using different time gate widths, including gates with duration longer than the laser period, and analyzed the resulting data using both standard nonlinear least-square fit (NLSF) and phasor analysis. We show that the fixed synchronization rate and large gate widths characterizing SS2 (10 ns and over) are not an obstacle to accurately extracting lifetime in the 1 ns range and to distinguishing between close lifetimes. As a result, SS2 and similar very large gated SPAD imagers appear as a versatile alternative to other widefield time-resolved detectors for NIR fluorescence lifetime imaging, including preclinical molecular applications.

FLIM↗

Changes in supramolecular organization of cyanobacterial thylakoid membrane complexes in response to far-red light photoacclimation

Cyanobacteria are ubiquitous in nature and have developed numerous strategies that allow them to live in a diverse range of environments. Certain cyanobacteria synthesize chlorophylls d and f to acclimate to niches enriched in far-red light (FRL) and incorporate paralogous photosynthetic proteins into their photosynthetic apparatus in a process called FRL-induced photoacclimation (FaRLiP). We characterized the macromolecular changes involved in FRL-driven photosynthesis and used atomic force microscopy to examine the supramolecular organization of photosystem I associated with FaRLiP in three cyanobacterial species. Mass spectrometry showed the changes in the proteome of Chroococcidiopsis thermalis PCC 7203 that accompany FaRLiP. Fluorescence lifetime imaging microscopy and electron microscopy reveal an altered cellular distribution of photosystem complexes and illustrate the cell-to-cell variability of the FaRLiP response.

59 BASIC BIOLOGICAL SCIENCES↗

A red-emitting carborhodamine for monitoring and measuring membrane potential

Biological membrane potentials, or voltages, are a central facet of cellular life. Optical methods to visualize cellular membrane voltages with fluorescent indicators are an attractive complement to traditional electrode-based approaches, since imaging methods can be high throughput, less invasive, and provide more spatial resolution than electrodes. Recently developed fluorescent indicators for voltage largely report changes in membrane voltage by monitoring voltage-dependent fluctuations in fluorescence intensity. However, it would be useful to be able to not only monitor changes but also measure values of membrane potentials. This study discloses a fluorescent indicator which can address both. We describe the synthesis of a sulfonated tetramethyl carborhodamine fluorophore. When this carborhodamine is conjugated with an electron-rich, methoxy (-OMe) containing phenylenevinylene molecular wire, the resulting molecule, CRhOMe, is a voltage-sensitive fluorophore with red/far-red fluorescence. Using CRhOMe, changes in cellular membrane potential can be read out using fluorescence intensity or lifetime. In fluorescence intensity mode, CRhOMe tracks fast-spiking neuronal action potentials (APs) with greater signal-to-noise than state-of-the-art BeRST 1 (another voltage-sensitive fluorophore). CRhOMe can also measure values of membrane potential. The fluorescence lifetime of CRhOMe follows a single exponential decay, substantially improving the quantification of membrane potential values using fluorescence lifetime imaging microscopy (FLIM). The combination of red-shifted excitation and emission, mono-exponential decay, and high voltage sensitivity enable fast FLIM recording of APs in cardiomyocytes. The ability to both monitor and measure membrane potentials with red light using CRhOMe makes it an important approach for studying biological voltages.

59 BASIC BIOLOGICAL SCIENCES↗

PLEKHA7 signaling is necessary for the growth of mutant KRAS driven colorectal cancer

Plekha7 (Pleckstrin homology [PH] domain containing, family A member 7) regulates the assembly of proteins of the cytoplasmic apical zonula adherens junction (AJ), thus ensuring cell-cell adhesion and tight-junction barrier integrity. Little is known of Plekha7 function in cancer. In colorectal cancer (CRC) Plekha7 expression is elevated compared to adjacent normal tissue levels, increasing with clinical stage. Plekha7 was present at plasma membrane AJ with wild-type KRas (wt-KRas) but was dispersed in cells expressing mutant KRas (mut-KRas). Fluorescence lifetime imaging microscopy (FLIM) indicated a direct Plekha7 interaction with wt-KRas but scantily with mut-KRas. Inhibiting Plekha7 specifically decreased mut-KRas cell signaling, proliferation, attachment, migration, and retarded mut-KRAS CRC tumor growth. Binding of diC8-phosphoinositides (PI) to the PH domain of Plekha7 was relatively low affinity. This may be because a D175 amino acid residue plays a “sentry” role preventing PI(3,4)P{sub 2} and PI(3,4,5)P{sub 3} binding. Molecular or pharmacological inhibition of the Plekha7 PH domain prevented the growth of mut-KRas but not wt-KRas cells. Taken together the studies suggest that Plekha7, in addition to maintaining AJ structure plays a role in mut-KRas signaling and phenotype through interaction of its PH domain with membrane mut-KRas, but not wt-KRas, to increase the efficiency of mut-KRas downstream signaling.

60 APPLIED LIFE SCIENCES↗

Light-sheet autofluorescence lifetime imaging with a single-photon avalanche diode array

Significance: Fluorescence lifetime imaging microscopy (FLIM) of the metabolic co-enzyme nicotinamide adenine dinucleotide (phosphate) [NAD(P)H] is a popular method to monitor single-cell metabolism within unperturbed, living 3D systems. However, FLIM of NAD(P)H has not been performed in a light-sheet geometry, which is advantageous for rapid imaging of cells within live 3D samples. Aim: We aim to design, validate, and demonstrate a proof-of-concept light-sheet system for NAD(P)H FLIM. Approach: A single-photon avalanche diode camera was integrated into a light sheet microscope to achieve optical sectioning and limit out-of-focus contributions for NAD(P)H FLIM of single cells. Results: An NAD(P)H light-sheet FLIM system was built and validated with fluores cence lifetime standards and with time-course imaging of metabolic perturbations in pancreas cancer cells with 10 s integration times. NAD(P)H light-sheet FLIM in vivo was demonstrated with live neutrophil imaging in a larval zebrafish tail wound also with 10 s integration times. Finally, the theoretical and practical imaging speeds for NAD(P)H FLIM were compared across laser scanning and light-sheet geometries, indicating a 30× to 6× acquisition speed advantage for the light sheet compared to the laser scanning geometry. Conclusions: FLIM of NAD(P)H is feasible in a light-sheet geometry and is attrac tive for 3D live cell imaging applications, such as monitoring immune cell metabolism and migration within an organism.

47 OTHER INSTRUMENTATION↗

A General Autofluorescence Method to Characterize Polymerization Progress

An autofluorescence technique to characterize polymerization progress in real time/in line was developed, which functioned in the absence of typical fluorogenic groups on the monomer or polymer. The monomer dicyclopentadiene and polymer polydicyclopentadiene are hydrocarbons that lack traditional functional groups for fluorescence spectroscopy. Here, the autofluorescence of formulations containing this monomer and polymer during ruthenium-catalyzed ring-opening metathesis polymerization (ROMP) was harnessed for reaction monitoring. The methods fluorescence recovery after photobleaching (FRAP) and here-developed fluorescence lifetime recovery after photobleaching (FLRAP) characterized polymerization progress in these native systems—without requiring exogenous fluorophore. (Auto)fluorescence lifetime recovery changes during polymerization correlated linearly to degree of cure, providing a quantitative link with reaction progress. These changing signals also provided relative rates of background polymerization, enabling comparison of 10 different catalyst–inhibitor-stabilized formulations. Multiple-well analysis demonstrated suitability for future high-throughput evaluation of formulations for thermosets. Furthermore, the central concept of the combined autofluorescence and FLRAP/FRAP method may be extendable to monitoring other polymerization reactions previously overlooked for lack of an obvious fluorescence handle.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A modular chemigenetic calcium indicator for multiplexed in vivo functional imaging

Abstract Genetically encoded fluorescent calcium indicators allow cellular-resolution recording of physiology. However, bright, genetically targetable indicators that can be multiplexed with existing tools in vivo are needed for simultaneous imaging of multiple signals. Here we describe WHaloCaMP, a modular chemigenetic calcium indicator built from bright dye-ligands and protein sensor domains. Fluorescence change in WHaloCaMP results from reversible quenching of the bound dye via a strategically placed tryptophan. WHaloCaMP is compatible with rhodamine dye-ligands that fluoresce from green to near-infrared, including several that efficiently label the brain in animals. When bound to a near-infrared dye-ligand, WHaloCaMP shows a 7× increase in fluorescence intensity and a 2.1-ns increase in fluorescence lifetime upon calcium binding. We use WHaloCaMP1a to image Ca 2+ responses in vivo in flies and mice, to perform three-color multiplexed functional imaging of hundreds of neurons and astrocytes in zebrafish larvae and to quantify Ca 2+ concentration using fluorescence lifetime imaging microscopy (FLIM).

Biochemistry & Molecular Biology↗

Ultra-high Information-content Chemical Imaging with Broadband Coherent Anti-Stokes Raman and Two-photon Fluorescence Lifetime Microscopy

Raman fingerprint spectroscopy and fluorescence lifetime imaging are emerging tools for studying metabolic profiles of biological specimens. While Raman fingerprint spectroscopy detects intrinsic molecular vibrations that reflect the molecular composition and chemical environment of a sample, fluorescence lifetime imaging measures changes in the excited-state lifetime of fluorophores that are sensitive to their microenvironments. Here, we present a multimodal imaging platform combining broadband coherent anti-Stokes Raman scattering (BCARS) and two-photon fluorescence lifetime imaging (2p-FLIM) microscopy that can acquire biologically relevant Raman fingerprint spectra and fluorescence lifetime signals in vivo and simultaneously. The tremendous chemical information obtained from spatially co-registered BCARS and 2p-FLIM images allows us to characterize the subtle differences between sub-cellular compartments and verify the potential false-positive results generated by fluorescence imaging alone. This is demonstrated by directly comparing the BCARS, 2p-FLIM, and two-photon excitation fluorescence(TPEF) signals simultaneously obtained from the same dye-stained organelle in the live, intact C. elegans expressing a green fluorescent protein (GFP) marker. In this work, we introduce the BCARS/2p-FLIM/TPEF setup scheme, the image acquisition steps, data processing, and representative results showing that the cross-modality imaging method enables rigorous characterization and in vivo detection at sub-cellular resolution. Furthermore, this protocol provides a framework for simultaneous chemical and fluorescence lifetime imaging to improve the accuracy of biological interpretation in complex living systems.

Xu, Haoyu [Georgia Institute of Technology, Atlant↗

Contribution of advanced fluorescence nano microscopy towards revealing mitotic chromosome structure

The organization of chromatin into higherorder structures and its condensation process represent one of the key challenges in structural biology. This is important for elucidating several disease states. To address this long-standing problem, development of advanced imaging methods has played an essential role in providing understanding into mitotic chromosome structure and compaction. Amongst these are two fast evolving fluorescence imaging technologies, specifically fluorescence lifetime imaging (FLIM) and superresolution microscopy (SRM). FLIM in particular has been lacking in the application of chromosome research while SRM has been successfully applied although not widely. Furthermore, both these techniques are capable of providing fluorescence imaging with nanometer information. SRM or "nanoscopy" is capable of generating images of DNA with less than 50 nm resolution while FLIM when coupled with energy transfer may provide less than 20 nm information. Here, we discuss the advantages and limitations of both methods followed by their contribution to mitotic chromosome studies. Furthermore, we highlight the future prospects of how advancements in new technologies can contribute in the field of chromosome science.

59 BASIC BIOLOGICAL SCIENCES↗