Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluorescence sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of Bio-Compatible Fluorescent Sensor

The development for biocompatible fluorescent sensors is used to understand the movement and fracking of wild boar at SRS. Current fracking methods for wild boar include physical tagging, camera monitoring, and foot tracks in the soil. None of these methods are highly effective in determining the path and habits of the animals as it depends on live imaging, soil consistency (lack of rain), and potentially a gps system is tagged properly. This system allows fracking using an additive digested by the animal and released in the urine that will fluoresce when excited with a particular laser. This method helps determine the actual movements of the animals and even provide a potential prediction model based on their routine. We partnered with Ft. Gordon to utilize their animal testing expertise in determining the best material and pathway for these materials to be excreted.

47 OTHER INSTRUMENTATION↗

Development of a Low-Cost, Sensitivity-Optimized Fluorescence Sensor for Visible Spectrum Analysis

This paper presents an economically viable, sensitivity-optimized fluorescence sensor for detecting low concentrations of fluorophores in the visible spectrum range. The sensor employs a deep ultraviolet (DUV) 275-nm LED and a dichroic mirror to establish a co-axial optical path for excitation and emission. Instead of utilizing a general-purposed spectrometer optimized for high spectral resolution, the sensor strikes a balance between resolution and sensitivity by using an appropriate aperture size and optimized optical design tailored for the spectral characteristics of fluorophores. Here, the manuscript demonstrates measurements of ppb-level rare earth element (REE) samples containing terbium (Tb), europium (Eu), dysprosium (Dy), and samarium (Sm) in aqueous solutions. Through balanced design that optimizes collection of fluorescence emission without losing spectral information, this work shows the feasibility of developing a low-cost, compact, and highly sensitive fluorescence sensors with improved detection sensitivity when compared to bench-top commercial spectrofluorometers at far higher costs.

47 OTHER INSTRUMENTATION↗

Stepwise Assembly of Turn‐on Fluorescence Sensors in Multicomponent Metal–Organic Frameworks for in Vitro Cyanide Detection

Abstract The controlled synthesis of multicomponent metal–organic frameworks (MOFs) allows for the precise placement of multiple cooperative functional groups within a framework, leading to emergent synergistic effects. Herein, we demonstrate that turn‐on fluorescence sensors can be assembled by combining a fluorophore and a recognition moiety within a complex cavity of a multicomponent MOF. An anthracene‐based fluorescent linker and a hemicyanine‐containing CN − ‐responsive linker were sequentially installed into the lattice of PCN‐700. The selective binding of CN − to hemicyanine inhibited the energy transfer between the two moieties, resulting in a fluorescence turn‐on effect. Taking advantage of the high tunability of the MOF platform, the ratio between anthracene and the hemicyanine moiety could be fine‐tuned in order to maximize the sensitivity of the overall framework. The optimized MOF‐sensor had a CN − ‐detection limit of 0.05 μ m , which is much lower than traditional CN − fluorescent sensors (about 0.2 μ m ).

Li, Jialuo↗

A robust and multifunctional calcium coordination polymer as a selective fluorescent sensor for acetone and iron (+3) and as a tunable proton conductor

A multifunctional calcium coordination polymer (Ca-CP) formulated as [(CH 3 ) 2 NH 2 ][Ca(Me 2 tcpbH)(H 2 O)] (1) has been synthesized and characterized. Compound 1 features a robust and novel three-dimensional (3D) network with cage-like cavities. The high thermal and moisture stability of the title compound makes it a good candidate for possible environment or energy related applications. Fluorescence (FL) studies demonstrate that 1 shows emission with a maximum at 350 nm under 270 nm excitation. The title compound acts as a selective and sensitive fluorescent sensor for the detection of acetone and Fe 3+ ions at low concentrations. The FL intensity quenching percentage and the concentration ratio of Fe 3+ /Fe 2+ showed a linear relation with a Fe 3+ concentration as low as 50 μM in Fe 2+ aqueous solutions, offering an easy way to probe the extent of Fe 2+ oxidation. Moreover, due to the relatively high hydration character of Ca 2+ , the terminal water molecules and undeprotonated carboxylate groups form a strong hydrogen-bonded network within the structure, facilitating its tunable proton conduction under various humidity and temperature conditions. The proton conducting mechanism has been investigated using PXRD, IR, and EA methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Miniature fluorescence sensor for quantitative detection of brain tumour

Fluorescence-guided surgery has emerged as a vital tool for tumour resection procedures. As well as intraoperative tumour visualisation, 5-ALA-induced PpIX provides an avenue for quantitative tumour identification based on ratiometric fluorescence measurement. To this end, fluorescence imaging and fibre-based probes have enabled more precise demarcation between the cancerous and healthy tissues. These sensing approaches, which rely on collecting the fluorescence light from the tumour resection site and its “remote” spectral sensing, introduce challenges associated with optical losses. In this work, we demonstrate the viability of tumour detection at the resection site using a miniature fluorescence measurement system. Unlike the current bulky systems, which necessitate remote measurement, we have adopted a millimetre-sized spectral sensor chip for quantitative fluorescence measurements. A reliable measurement at the resection site requires a stable optical window between the tissue and the optoelectronic system. This is achieved using an antifouling diamond window, which provides stable optical transparency. The system achieved a sensitivity of 92.3% and specificity of 98.3% in detecting a surrogate tumour at a resolution of 1 × 1 mm 2 . In conclusion, as well as addressing losses associated with collecting and coupling fluorescence light in the current ‘remote’ sensing approaches, the small size of the system introduced in this work paves the way for its direct integration with the tumour resection tools with the aim of more accurate interoperative tumour identification.

59 BASIC BIOLOGICAL SCIENCES↗

Survey for Life-related Species During a Planetary Surface Exploration; System Type I - UV Stimulated Fluorescent Sensor

The widely accepted minimum requirements for life on Earth include the presence of water and accessible sources of carbon. We assume that the same criteria must hold for putative life on past or present Mars. The evidence for CO2 and H2O at or near the Martian surface, carbon in Martian meteorites, aqueous alteration, and probable hydrothermal activity suggest that conditions conducive to the origin and evolution of life on Mars may have existed for long periods of time and may still obtain at present. Surface exploration on Mars that enables the direct detection of water in minerals and of organic carbon (including not just organic and biogenic materials but their degradation products such as kerogen-like hydrocarbons and graphitized carbon) that might be products or residues of biologic activity, is crucial. The search for evidence of life, past or present, will nevertheless be difficult. The lack of direct evidence for organic carbon and the low amounts of water found in the soils at the Viking sites demonstrated the difficulties. Recent results of GRS experiment of Odyssey mission indicated the existence of abundant water ice beneath the Mars surface. Mineralogical evidence for the presence of carbonate, sulfates, or clay minerals, products of weathering and aqueous deposition, have not been identified unambiguously on Mars. Rocks such as shales and, more particularly, limestones, which we associate with moist and benign environments on Earth, are evidently not abundant. Presumably, then, neither were the photosynthetic organisms that might have produced them. In addition, the harsh present environment on Mars (e.g., dryness, low temperatures, large temperature cycles, high level of UV light on the surface, frequent dust storms, etc.) can both destroy carbon- and water-bearing materials and hide them. Therefore, directly detecting life-related materials on Mars was likened to seeking and examining proverbial needles in haystacks. We argue that survey type instruments, that can frequently and quickly check a relatively large amount of material at many locations during a mission, are essential.

Wang, Alian↗

Integrated Fluorescence

A detection method is integrated with a filtering method and an enhancement method to create a fluorescence sensor that can be miniaturized. The fluorescence sensor comprises a thin film geometry including a waveguide layer, a metal film layer and sensor layer. The thin film geometry of the fluorescence sensor allows the detection of fluorescent radiation over a narrow wavelength interval. This enables wavelength discrimination and eliminates the detection of unwanted light from unknown or spurious sources.

Tuma, Margaret↗

Fluorescent compositions

A fluorescent composition includes at least one of a fluorescent sensor compound and organic reporter molecules encapsulated in a microsphere structure. When encapsulated, the fluorescent sensor compound and the organic reporter molecules are distributed in a liquid organic matrix. When non-encapsulated, the remaining one of the fluorescent sensor compound and the organic reporter molecules reside in the matrix. In response to a force applied to the composition sufficient to break at least a portion of the microsphere structure, the fluorescent sensor compound and the organic reporter molecules are transformed into a non-reversible fluorescent state exhibiting a quantum yield greater than 0.2. The fluorescent state is objectively visually verifiable without physically contacting the composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorescent compositions

An article that includes a fluorescent composition having at least one of a fluorescent sensor compound and organic reporter molecules encapsulated in a microsphere structure. When encapsulated, the fluorescent sensor compound and the organic reporter molecules are distributed in a liquid organic matrix. When non-encapsulated, the remaining one of the fluorescent sensor compound and the organic reporter molecules reside in the matrix. In response to a force applied to the composition sufficient to break at least a portion of the microsphere structure, the fluorescent sensor compound and the organic reporter molecules are transformed into a non-reversible fluorescent state exhibiting a quantum yield greater than 0.2. The fluorescent state is objectively visually verifiable without physically contacting the composition.

Smartt, Heidi A.↗

Fluorescent compositions

An article that includes a fluorescent composition having at least one of a fluorescent sensor compound and organic reporter molecules encapsulated in a microsphere structure. When encapsulated, the fluorescent sensor compound and the organic reporter molecules are distributed in a liquid organic matrix. When non-encapsulated, the remaining one of the fluorescent sensor compound and the organic reporter molecules reside in the matrix. In response to a force applied to the composition sufficient to break at least a portion of the microsphere structure, the fluorescent sensor compound and the organic reporter molecules are transformed into a non-reversible fluorescent state exhibiting a quantum yield greater than 0.2. The fluorescent state is objectively visually verifiable without physically contacting the composition.

Smartt, Heidi A.↗

Two-Photon/Laser-Induced Fluorescence (TP/LIF) sensor

The Two-Photon/Laser-Induced Fluorescence (TP/LIF) technique is based on the stepwise excitation of the OH transitions, X(exp 2)II, v(exp '') = 0 yields X(exp 2)II, v(exp '') = 1 (lambda = 2.9 microns) and X(exp 2)II v(exp '') = 1 yields A(exp2)Sigma, v' = 0 (lambda = 345 nm) with background free fluorescence monitoring of the A(exp 2)Sigma, v' = 0 yields X(exp 2)II, v(exp '') = 0 transition near 309 nm. This technique has awaited the advent of a suitable mid-infrared (2.9 microns) laser source. Turnable mid-IR lasers now exist that are capable of meeting the specifications required of a high sensitivity TP/LIF OH sensor.

Bradshaw, John D.↗

Fluorescent aromatic sensors and their methods of use

Aromatic molecules that can be used as sensors are described. The aromatic sensors include a polycyclic aromatic hydrocarbon core with a five-membered imide rings fused to the core and at least two pendant aryl groups. The aromatic sensor molecules can detect target analytes or molecular strain as a result of changes in their fluorescence, in many cases with on-off behavior. Aromatic molecules that fluoresce at various frequencies can be prepared by altering the structure of the aromatic core or the substituents attached to it. The aromatic molecules can be used as sensors for various applications such as, for example, the detection of dangerous chemicals, biomedical diagnosis, and the detection of damage or strain in composite materials. Methods of preparing aromatic sensor molecules are also described.

Meador, Michael A.↗

Fluorescence-Based Sensor for Monitoring Activation of Lunar Dust

This sensor unit is designed to determine the level of activation of lunar dust or simulant particles using a fluorescent technique. Activation of the surface of a lunar soil sample (for instance, through grinding) should produce a freshly fractured surface. When these reactive surfaces interact with oxygen and water, they produce hydroxyl radicals. These radicals will react with a terephthalate diluted in the aqueous medium to form 2-hydroxyterephthalate. The fluorescence produced by 2-hydroxyterephthalate provides qualitative proof of the activation of the sample. Using a calibration curve produced by synthesized 2-hydroxyterephthalate, the amount of hydroxyl radicals produced as a function of sample concentration can also be determined.

Wallace, William T.↗

Developing Fluorescence-Based Sensors to Support Rare Earth Element Separation

Rare earth elements (REEs) are essential to most renewable energy technologies. Unfortunately, as we transition to sustainable energy production, the demand for REEs is rapidly growing well beyond current rates of production. As a result, novel means of efficient, scalable, and easily adaptable methods for processing primary and recycle feedstocks are needed. Development and integration of sensors for highly selective in-line monitoring can support more efficient design and testing of such novel separation processes, as well as more cost-effective deployment of those separation flowsheets. Work here will explore the application of fluorescence spectroscopy, a highly sensitive and selective technique, to quantify multiple lanthanides in complex mixtures including known interferents or quenching agents. Results include identification of the optimal excitation wavelength and the limit of detection of various rare earth elements as well as the performance of data-science-based quantification approaches in streams where “unknowns” are present. Overall, the data science tools in conjunction with optical sensor data were able to quantify analytes in the presence of other lanthanides which can be anticipated in the actual industrial stream. Here we include characterization of lanthanides in a microfluidic device similar to those used in new process development. This study demonstrates the capability of utilizing fluorescence spectroscopy to quantify analytes in a complicated solution matrix, suggesting this is a successful approach for in-line monitoring to optimize the separation efficiency in an industrial stream.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Oilspill surveillance, detection, and evaluation by remote sensing

Aerial and fixed platform oil spill detection systems primarily utilize remote sensors for data acquisition and pollution monitoring purposes. In addition to aerial photography and infrared reflectance sensors, a laser backscatter sensor and an ultraviolet fluorescence sensor are considered for application in pollution surveillance systems.

Jones, D. R.↗

Fluorescence Enhancement in the Solid State by Isolating Perylene Fluorophores in Metal–Organic Frameworks

Polycyclic aromatic hydrocarbons such as perylene, pyrene, and their derivatives are highly emissive fluorophores in solution. Furthermore, the practical applications of these materials in the field of molecular electronic and light emitting devices are often hindered by self-quenching effects due to the formation of non-fluorescent aggregates in concentrated solutions or in the solid state. Herein, we demonstrate that aggregation caused quenching of perylenes can be minimalized by molecular incorporation into metalorganic frameworks (MOFs). This study utilized a stable Zr 6 cluster-based MOF, UiO-67, as a matrix. Linear linkers containing the photo-responsive moieties were designed and incorporated into the parent UiO-67 scaffold through the partially replacement of the non-fluorescent linkers of a similar length, forming mixed-linker MOFs. Here, the average distance between perylene moieties was tuned by changing the linker ratios, thus controlling the fluorescence intensity, emission wavelength, and quantum yield. Molecular modeling was further adopted to correlate the number of isolated perylene linkers within the framework to the ratio between the two linkers, therefore rationalizing the change in the observed fluorescent properties. Taking advantage of the tunable fluorescence, inherent porosity, and high chemical stability of this MOF platform, it was applied as a fluorescent sensor for oxygen detection in the gas phase, a model reaction, showing fast response and good recyclability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗