Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluorometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Electrets and plant fluorometers used in field studies to measure hydrogen chloride produced during Space Shuttle launches

The results of the field tests of two monitoring device techniques, electrets and plant fluorometers are analyzed in order to determine the environmental effects of launch by-products and the extent of these effects. The STS launches are used because the Shuttle emits 2 1/2 times more HCl than any previous systems, it produces a voluminous ground cloud and, most important, it produces near field HCl deposition and revolatilization, far-field acid washout/rainout, and gaseous HCl diffusion. Field evaluations of electrets at STS-5, STS-6, and STS-8 have shown that qualitative assessments can be made for areas lightly or moderately impacted by gaseous and aerosol HCl. Field evaluation of the plant productivity fluorometer at STS-8 has shown that this system is also useful for qualitative assessment in areas lightly, moderately, or heavily affected by gaseous and aerosol HCl. Quantitative prediction of HCl may be possible in lightly and moderately affected areas, given deposition rates correlation.

Milligan, J. E.↗

Three color laser fluorometer for studies of phytoplankton fluorescence

A three-color laser fluorometer has been developed for field work operations. Using two tunable dye lasers (excitation wavelengths at 440 nm and 530 nm), broadband wavelength optical filters were selected to obtain maximum fluorescence sensitivity at wavelengths greater than 675 nm (chlorophyll) and 575 + or - 15 nm (phycoerythrin). The laser fluorometer permits the measurement of phytoplankton pigments under static or flowing conditions and more closely resembles the time scales (ns) and energy levels (mW) of other laser-induced fluorescence instruments.

Phinney, David A.↗

The Fraunhofer line discriminator: An airborne fluorometer

An experimental Fraunhofer Line Discriminator (FLD) can differentiate and measure solar-stimulated luminescence when viewed against a background of reflected light. Key elements are two extremely sensitive photomultipliers, two glass-spaced Fabry-Perot filters having a bandwidth less than 1 A, and an analog computer. As in conventional fluorometers, concentration of a fluorescent substance is measured by comparison with standards. Quantitative use is probably accurate only at low altitudes but detection of luminescent substances should be possible from any altitude. Applications of the present FLD include remote sensing of fluorescent dyes used in studies of current dynamics. The basic technique is applicable to detection of oil spills, monitoring of pollutants, and sensing over land areas.

Stoertz, G. E.↗

Improved Underwater Excitation-Emission Matrix Fluorometer

A compact, high-resolution, two-dimensional excitation-emission matrix fluorometer (EEMF) has been designed and built specifically for use in identifying and measuring the concentrations of organic compounds, including polluting hydrocarbons, in natural underwater settings. Heretofore, most EEMFs have been designed and built for installation in laboratories, where they are used to analyze the contents of samples collected in the field and brought to the laboratories. Because the present EEMF can be operated in the field, it is better suited to measurement of spatially and temporally varying concentrations of substances of interest. In excitation-emission matrix (EEM) fluorometry, fluorescence is excited by irradiating a sample at one or more wavelengths, and the fluorescent emission from the sample is measured at multiple wavelengths. When excitation is provided at only one wavelength, the technique is termed one-dimensional (1D) EEM fluorometry because the resulting matrix of fluorescence emission data (the EEM) contains only one row or column. When excitation is provided at multiple wavelengths, the technique is termed two-dimensional (2D) EEM fluorometry because the resulting EEM contains multiple rows and columns. EEM fluorometry - especially the 2D variety - is well established as a means of simultaneously detecting numerous dissolved and particulate compounds in water. Each compound or pool of compounds has a unique spectral fluorescence signature, and each EEM is rich in information content, in that it can contain multiple fluorescence signatures. By use of deconvolution and/or other mixture-analyses techniques, it is often possible to isolate the spectral signature of compounds of interest, even when their fluorescence spectra overlap. What distinguishes the present 2D EEMF over prior laboratory-type 2D EEMFs are several improvements in packaging (including a sealed housing) and other aspects of design that render it suitable for use in natural underwater settings. In addition, the design of the present 2D EEMF incorporates improvements over the one prior commercial underwater 2D EEMF, developed in 1994 by the same company that developed the present one. Notable advanced features of the present EEMF include the following: 1) High sensitivity and spectral resolution are achieved by use of an off-the-shelf grating spectrometer equipped with a sensor in the form of a commercial astronomical- grade 256 532-pixel charge-coupled-device (CCD) array. 2) All of the power supply, timing, control, and readout circuits for the illumination source and the CCD, ancillary environmental monitoring sensors, and circuitry for controlling a shutter or filter motor are custom-designed and mounted compactly on three circuit boards below a fourth circuit board that holds the CCD (see figure). 3) The compactness of the grating spectrometer, CCD, and circuit assembly makes it possible to fit the entire instrument into a compact package that is intended to be maneuverable underwater by one person. 4) In mass production, the cost of the complete instrument would be relatively low - estimated at approximately $30,000 at 2005 prices.

Moore, Casey↗

Feasibility of surveying pesticide coverage with airborne fluorometer

Response of a Fraunhofer line discriminator (FLD) to varying distributions of granulated corncobs stained with varying concentrations of Rhodamine WT dye was tested on the ground and from an H-19 helicopter. The granules are used as a vehicle for airborne emplacement of poison to control fire ants in the eastern and southeastern United States. Test results showed that the granules are detectable by FLD but that the concentration must be too great to be practical with the present apparatus. Possible methods for enhancement of response may include: (1) increasing dye concentration; (2) incorporating with the poisoned granules a second material to carry the dye alone; (3) use of a more strongly fluorescent substance (at 5890 A); (4) modifying the time interval after dyeing, or modifying the method of dyeing; (5) modifying the FLD for greater efficiency, increased field of view or larger optics; or (6) experimenting with laser-stimulated fluorescence.

Stoertz, G. E.↗

Test of airborne fluorometer over land surfaces and geologic materials

Response of an experimental Fraunhofer line discriminator to a wide range of surficial deposits common in deserts and semideserts was tested in the laboratory and from an H-19 helicopter. No signals attributable to fluorescence were recorded during 540 miles of aerial traverses over southeastern California and west-central Arizona. It was concluded that exposed surfaces of target materials throughout the traverses were either nonluminescent at 5890 A or not sufficiently so to be detectable. It cannot be ruled out that the lack of fluorescence is partly attributable to surficial coatings of nonluminescent weathered material. The principal route surveyed from the air was from Needles, California to Furnace Creek Ranch, Death Valley and return, via the Amargosa River valley, Silurian Lake (dry), Silver Lake (dry), and Soda Lake (dry). Principal targets traversed were unconsolidated clastic sediments ranging from silty clay to cobbles, and a wide range of evaporite deposits.

Stoertz, G. E.↗

A remote sensing laser fluorometer

A sensor is reported which is able to identify certain specific substances in water by means of their fluorescence spectra. In particular, the sensor detects oil, ligninsulfonates and chlorophyll. The device is able to measure the fluorescence spectra of water at ranges up to 75 m and to detect oil spills on water at altitudes up to 300 m. Blue light from a laser is used to excite the fluorescence of the target. Any light from the ambient background illumination, from the reflected laser light or from the induced fluorescence is gathered by a small telescope focused on the target. Optical filters are used to block the reflected laser light and to select the wavelengths of interest in the fluorescence spectrum of the target. The remaining light is detected with a photomultiplier tube. The amplitude of the laser induced fluorescence in the wavelength interval selected by the optical filters is displayed on a meter or strip chart recorder.

Oneill, R. A.↗

Lightweight Fiber Optic Gas Sensor for Monitoring Regenerative Food Production

In this final report, Physical Optics Corporation (POC) describes its development of sensors for oxygen, carbon dioxide, and relative humidity. POC has constructed a phase fluorometer that can detect oxygen over the full concentration range from 0 percent to 100 percent. Phase-based measurements offer distinct advantages, such as immunity to source fluctuation, photobleaching, and leaching. All optics, optoelectronics, power supply, and the printed circuit board are included in a single box; the only external connections to the fluorometer are the optical fiber sensor and a power cord. The indicator-based carbon dioxide sensor is also suitable for short-term and discrete measurements over the concentration range from 0 percent to 100 percent. The optical fiber-based humidity sensor contains a porous core for direct interaction of the light beam with water vapor within fiber pores; the detection range for the humidity sensor is 10 percent to 100 percent, and response time is under five minutes. POC is currently pursuing the commercialization of these oxygen and carbon dioxide sensors for environmental applications.

Schmidlin, Edward↗

Making Sense of Plant Health

Ciencia, Inc. created a new device, known as a Portable Photosynthesis Analyzer, or Phase Fluorometer, that provides real-time data about the photochemical efficiency of phytoplankton and other plant forms. The commercial version of this technology is used for photosynthesis research and offers major benefits to the field of life science. This new instrument is the first portable instrument of its kind. Through a license agreement with Ciencia, Oriel Instruments, of Stratford, Connecticut, manufactures and markets the commercial version of the instrument under the name LifeSense.TMLifeSense is a 70 MHz single-frequency fluorometer that offers unrivaled capabilities for fluorescence lifetime sensing and analysis. LifeSense provides information about all varieties of photosynthetic systems. Photosynthesis research contributes important health assessments about the plant, be it phytoplankton or a higher form of plant life. With its unique sensing capabilities, LifeSense furnishes data regarding the yield of a plant's photochemistry, as well as its levels of photosynthetic activity. The user can then gain an extremely accurate estimate of the plant's chlorophyll biomass, primary production rates, and a general overview of the plant's physiological condition.

Source record↗

Oceanographic Instrument

Developed under NASA contract, the Fast Repetition Rate (FRR) fluorometer is a computer-controlled instrument for measuring the fluorescence of phytoplankton, microscopic plant forms that provide sustenance for animal life in the oceans. The fluorometer sensor is towed by ship through the water and the resulting printouts are compared with satellite data. The instrument is non-destructive and can be used in situ, providing scientific information on ocean activity and productivity.

Source record↗

Satellite Remote Sensing Studies of Biological and Biogeochemical Processing in the Ocean

The remote sensing of phycoerythrin-containing phytoplankton by ocean color was evaluated. Phycoerythrin (PE) can be remotely sensed by three methods: surface reflectance (Sathyendranath et al. 1994), by laser-activated fluorescence (Hoge and Swift 1986) and by passive fluorescence (Letelier et al. 1996). In collaboration with Dr. Frank Hoge and Robert Swift during Dr. Maria Vernet's tenure as Senior Visiting Scientist at Wallops Island, the active and passive methods were studied, in particular the detection of PE fluorescence and spectral reflectance from airborne LIDAR (AOL). Airborne instrumentation allows for more detailed and flexible sampling of the ocean surface than satellites thus providing the ideal platform to test model and develop algorithms than can later be applied to ocean color by satellites such as TERRA and AQUA. Dr. Vernet's contribution to the Wallops team included determination of PE in the water column, in conjunction with AOL flights in the North Atlantic Bight. In addition, a new flow-through fluorometer for PE determination by fluorescence was tested and calibrated. Results: several goals were achieved during this period. Cruises to the California Current, North Atlantic Bight, Gulf of Maine and Chesapeake Bay provided sampling under different oceanographic and optical conditions. The ships carried the flow-through fluorometer and samples for the determination of PE were obtained from the flow-through flow. The AOL was flown over the ship's track, usually several flights during the cruise, weather permitting.

Vernet, Maria↗

FRET-Aptamer Assays for Bone Marker Assessment, C-Telopeptide, Creatinine, and Vitamin D

Astronauts lose 1.0 to 1.5% of their bone mass per month on long-duration spaceflights. NASA wishes to monitor the bone loss onboard spacecraft to develop nutritional and exercise countermeasures, and make adjustments during long space missions. On Earth, the same technology could be used to monitor osteoporosis and its therapy. Aptamers bind to targets against which they are developed, much like antibodies. However, aptamers do not require animal hosts or cell culture and are therefore easier, faster, and less expensive to produce. In addition, aptamers sometimes exhibit greater affinity and specificity vs. comparable antibodies. In this work, fluorescent dyes and quenchers were added to the aptamers to enable pushbutton, one-step, bind-and-detect fluorescence resonance energy transfer (FRET) assays or tests that can be freeze-dried, rehydrated with body fluids, and used to quantitate bone loss of vitamin D levels with a handheld fluorometer in the spacecraft environment. This work generated specific, rapid, one-step FRET assays for the bone loss marker C-telopeptide (CTx) when extracted from urine, creatinine from urine, and vitamin D congeners in diluted serum. The assays were quantified in nanograms/mL using a handheld fluorometer connected to a laptop computer to convert the raw fluorescence values into concentrations of each analyte according to linear standard curves. DNA aptamers were selected and amplified for several rounds against a 26- amino acid form of CTx, creatinine, and vitamin D. The commonalities between loop structures were studied, and several common loop structures were converted into aptamer beacons with a fluorophore and quencher on each end. In theory, when the aptamer beacon binds its cognate target (CTx bone peptide, creatinine, or vitamin D), it is forced open and no longer quenched, so it gives off fluorescent light (when excited) in proportion to the amount of target present in a sample. This proportional increase in fluorescence is called a "lights on" FRET response. The vitamin D aptamer beacon gives a "lights off" or inversely proportional fluorescence response to the amount of vitamin D present in diluted serum. These FRET-aptamer assays are rapid (<30 minutes), sensitive (low ng/mL detection limits), and quite easy to carry out (add sample, mix, and detect in the handheld reader). Benefits include the speed of the assays as well as the small amount of space taken up by the handheld reader and cuvette assays. The aptamer DNA sequences represent novel additional features of the existing (patent-pending) FRET-aptamer assay platform.

Bruno, John G.↗

Fraunhofer line-dept sensing applied to water

An experimental Fraunhofer line discriminator is basically an airborne fluorometer, capable of quantitatively measuring the concentration of fluorescent substances dissolved in water. It must be calibrated against standards and supplemented by ground-truth data on turbidity and on approximate vertical distribution of the fluorescent substance. Quantitative use requires that it be known in advance what substance is the source of the luminescence emission; qualitative sensing, or detection of luminescence is also possible. The two approaches are fundamentally different, having different purposes, different applications, and different instruments. When used for sensing of Rhodamine WT dye in coastal waters and estuaries, the FLD is sensing in the spectral region permitting nearly maximum depth of light penetration.

Stoertz, G. E.↗

Laboratory studies of in vivo fluorescence of phytoplankton

A lidar system is developed that uses four selected excitation wavelengths to induce chlorophyll 'a' fluorescence which is indicative of both the concentration and diversity of phytoplankton. The operating principles of the system and the results of measurements of phytoplankton fluorescence in a controlled laboratory environment are presented. A comparative study of results from lidar fluorosensor laboratory tank tests using representative species of phytoplankton in single and multispecies cultures from each of four color groups reveals that (1) there is good correlation between the fluorescence of chlorophyll 'a' remotely simulated and detected by the lidar system and in-situ measurements using four similar excitation wavelengths in a flow-through fluorometer; (2) good correlation exists between the total chlorophyll 'a' calculated from lidar-fluorosensor data and measurements obtained by the Strickland-Parsons method; and (3) the lidar fluorosensor can provide an index of population diversity.

Brown, C. A., Jr.↗

Satellite detection of phytoplankton export from the mid-Atlantic Bight during the 1979 spring bloom

Analysis of Coastal Zone Color Scanner (CZCS) imagery confirms shipboard and in situ moored fluorometer observations of resuspension of near-bottom chlorophyll within surface waters (1 to 10 m) by northwesterly wind events in the mid-Atlantic Bight. As much as 8 to 16 micrograms chl/l are found during these wind events from March to May, with a seasonal increase of algal biomass until onset of stratification of the water column. Rapid sinking or downwelling apparently occurs after subsequent wind events, however, such that the predominant surface chlorophyll pattern is approx. 0.5 to 1.5 micrograms/l over the continental shelf during most of the spring bloom. Perhaps half of the chlorophyll increase observed by satellite during a wind resuspension event represents in-situ production during the 4 to 5 day interval, with the remainder attributed to accumulation of algal biomass previously produced and temporarily stored within near-bottom water. Present calculations suggest that about 10% of the primary production of the spring bloom may be exported as ungrazed phytoplankton carbon from mid-Atlantic shelf waters to those of the continental slope.

Walsh, J. J.↗

High frequency sampling of the 1984 spring bloom within the mid-Atlantic Bight: Synoptic shipboard, aircraft, and in situ perspectives of the SEEP-I experiment

Moorings of current meters, thermistors, transmissometers, and fluorometers on the mid-Atlantic shelf, south of Long Island, suggest a cumulative seaward export of perhaps 0.35 g C/sq m/day between the 80 and 120 m isobaths during February-April 1984. Such a horizontal loss of algal carbon over the lower third of the water column would be 23 to 78% of the March-April 1984 primary production. This physical carbon loss is similar to daily grazing losses from zooplankton of 32-40% of the algal fixation of carbon. Metabolic demands of the benthos could be met by just the estimated fecal pellet flux, without direct consumption of algal carbon, while bacterioplankton needs could be served by excretory release of dissolved organic matter during photosynthesis. Sediment traps tethered 10 m off the bottom at the 120 m isobath and 50 m above the 500 m isobath caught as much as 0.16 to 0.26 g C /sq m/day during March-April 1984, in reasonable agreement with the flux estimated from the other moored instruments.

Walsh, J. J.↗