SEARCH · Search NASA
Results for “flux”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Design of a Modular E-Core Flux Concentrating Axial Flux Machine
In this paper a novel E-Core axial flux machine is proposed. The machine has a double stator-single rotor configuration with flux concentrating ferrite magnets, and pole windings across each leg of an E-Core stator. E-Core stators with the proposed flux-concentrating rotor arrangement result in better magnet utilization and higher torque density. The machine also has a modular structure facilitating simpler construction. This paper presents a single phase and a three-phase version of the E-Core machine. Case study for a 1.1 kW, 400 rpm machine for both the single phase and three-phase axial flux machine is presented. The results are verified through 3D finite element analysis.
Amplitude flux, probability flux, and gauge invariance in the finite volume scheme for the Schrödinger equation
The time-dependent Schrödinger equation can be put in a probability conserving, gauge invariant form, on arbitrary structured grids via finite volume discretization. The gauge terms in the discrete system cancel with a portion of the amplitude flux to produce abbreviated flux functions. The resulting time translation operator is strictly unitary, and is compatible with an efficient operator splitting scheme that allows for multi-dimensional simulation with complex grid geometries. Moreover, the abbreviated amplitude flux is necessary to the construction of a conservative probability current. This construction turns out to be important when computing Bohmian trajectories in multi-dimensions. Bohmian trajectories are useful in the interpretation of quantum mechanical phenomena such as tunneling ionization, and provide a bridge between quantum and classical regimes.
An ecosystem-scale perspective of the net land methanol flux: synthesis of micrometeorological flux measurements
We present field observations made in June 2011 downwind of Dallas-Fort Worth, TX, and evaluate the role of stabilized Criegee radicals (sCIs) in gaseous sulfuric acid (H2SO4) production. Zero-dimensional model calculations show that sCI from BVOCs composed the majority of the sCIs. The main uncertainty associated with an evaluation of H2SO4 production from the sCI reaction channel is the lack of experimentally determined reaction rates for sCIs formed from isoprene ozonolysis with SO2. In general, the maximum of H2SO4 production from the sCI channel is found in the late afternoon as ozone increases towards the late afternoon. The sCI channel, however, contributes minor H2SO4 production compared with the conventional OH channel. Finally, The production and the loss rates of H2SO4 are compared. The application of the recommended mass accommodation coefficient causes significant overestimation of H2SO4 loss rates compared with H2SO4 production rates. On the other hand, the application of a lower experimental value for the mass accommodation coefficient provides good agreement between the loss and production rates of H2SO4. The results suggest that the recommended coefficient for the H2O surface may not be suitable for this relatively dry environment.
The first measurements of soft x-ray flux from ignition scale Hohlraums at the National Ignition Facility using DANTE (invited)
The first 96 and 192 beam vacuum Hohlraum target experiments have been fielded at the National Ignition Facility demonstrating radiation temperatures up to 340 eV and fluxes of 20 TW/sr as viewed by DANTE representing an {approx}20 times flux increase over NOVA/Omega scale Hohlraums. The vacuum Hohlraums were irradiated with 2 ns square laser pulses with energies between 150 and 635 kJ. They produced nearly Planckian spectra with about 30{+-}10% more flux than predicted by the preshot radiation hydrodynamic simulations. To validate these results, careful verification of all component calibrations, cable deconvolution, and software analysis routines has been conducted. In addition, a half Hohlraum experiment was conducted using a single 2 ns long axial quad with an irradiance of {approx}2x10{sup 15} W/cm{sup 2} for comparison with NIF Early Light experiments completed in 2004. We have also completed a conversion efficiency test using a 128-beam nearly uniformly illuminated gold sphere with intensities kept low (at 1x10{sup 14} W/cm{sup 2} over 5 ns) to avoid sensitivity to modeling uncertainties for nonlocal heat conduction and nonlinear absorption mechanisms, to compare with similar intensity, 3 ns OMEGA sphere results. The 2004 and 2009 NIF half-Hohlraums agreed to 10% in flux, but more importantly, the 2006 OMEGA Au Sphere, the 2009 NIF Au sphere, and the calculated Au conversion efficiency agree to {+-}5% in flux, which is estimated to be the absolute calibration accuracy of the DANTEs. Hence we conclude that the 30{+-}10% higher than expected radiation fluxes from the 96 and 192 beam vacuum Hohlraums are attributable to differences in physics of the larger Hohlraums.
Flux Transfer Events Simultaneously Observed by Polar and Cluster: Flux Rope in the Subsolar Region and Flux Tube Addition to the Polar Cusp
The phenomenon called flux transfer events (FTEs) is widely accepted as the manifestation of time-dependent reconnection. In this paper, we present observational evidence of a flux transfer event observed simultaneously at low-latitude by Polar and at high-latitude by Cluster. This event occurs on March 21, 2002, when both Cluster and Polar are located near local noon but with a large latitudinal separation. During the event, Cluster is moving outbound from the polar cusp to the magnetosheath, and Polar is in the magnetosheath near the equatorial magnetopause. The observations show that a flux transfer event occurs between the equator and the northern cusp. Polar and Cluster observe the FTE s two open flux tubes: Polar encounters the southward moving flux tube near the equator; and Cluster the northward moving flux tube at high latitude. The low latitude FTE appears to be a flux rope with helical magnetic field lines as it has a strong core field and the magnetic field component in the boundary normal direction exhibits a strong bi-polar variation. Unlike the low-latitude FTE, the high-latitude FTE observed by Cluster does not exhibit the characteristic bi-polar perturbation in the magnetic field. But the plasma data clearly reveal its open flux tube configuration. It shows that the magnetic field lines have straightened inside the FTE and become more aligned to the neighboring flux tubes as it moves to the cusp. Enhanced electrostatic fluctuations have been observed within the FTE core, both at low- and high-latitudes. This event provides a unique opportunity to understand high-latitude FTE signatures and the nature of time-varying reconnection.
Effect of nonaxisymmetric magnetic perturbations on divertor heat and particle flux profiles in National Spherical Torus Experiment
Small, nonaxisymmetric magnetic perturbations generated by external coils have been found to break the axisymmetry of heat and particle flux deposition pattern in the divertor area in the National Spherical Torus Experiment (NSTX). This breaking by the applied 3-D field causes strike point splitting that is represented as local peaks and valleys in the divertor profiles. In case of n = 3 fields application, the broken toroidal symmetry of the divertor profile shows 120 deg. of spatial periodicity while data for n = 1 fields provide a fully nonaxisymmetric heat and particle deposition. Field line tracing showed good agreement with the measured heat and particle flux profiles. Higher toroidal mode number (n = 3) of the applied perturbation produced more and finer striations in the divertor profiles than in the lower mode number (n = 1) case. Following the previous result of the intrinsic strike point splitting by the n = 3 error fields [Nucl. Fusion 50, 045010 (2010); J. Nucl. Mater. (2011), doi:10.1016/j.jnucmat.2011.01.115], result of the connection length profile from field line tracing identifies intrinsic error field as a possible source of the intrinsic splitting. In determining the strike point splitting pattern, q{sub 95} is found to play an important role; higher q{sub 95} produces finer striations and induces higher fraction of heat flux to flow through the split strike point channels. Higher pedestal electron collisionality also made the striations in the D{sub {alpha}} profile more pronounced in the given range of collisionality variation. The radial location of local peaks in the profiles during the triggered edge localized modes (ELMs) by the applied n = 3 fields stays similar before and after the application. This shows that the heat flux from the triggered ELMs follows the mode number of the applied perturbation. The external magnetic perturbation can reattach detached divertor plasma, but this can be overcome by detaching the plasma with additional divertor gas puffing.
Etalon-induced baseline drift and correction in atom flux sensors based on atomic absorption spectroscopy
Atom flux sensors based on atomic absorption (AA) spectroscopy are of significant interest in thin film growth as they can provide unobtrusive, element specific real-time flux sensing and control. The ultimate sensitivity and performance of these sensors are strongly affected by baseline drift. Here we demonstrate that an etalon effect resulting from temperature changes in optical viewport housings is a major source of signal instability, which has not been previously considered, and cannot be corrected using existing methods. We show that small temperature variations in the fused silica viewports can introduce intensity modulations of up to 1.5% which in turn significantly deteriorate AA sensor performance. This undesirable effect can be at least partially eliminated by reducing the size of the beam and tilting the incident light beam off the viewport normal.
The galactic contribution to IceCube's astrophysical neutrino flux
High energy neutrinos have been detected by IceCube, but their origin remains a mystery. Determining the sources of this flux is a crucial first step towards multi-messenger studies. Here, we systematically compare two classes of sources with the data: Galactic and extragalactic. We assume that the neutrino sources are distributed according to a class of Galactic models. We build a likelihood function on an event by event basis including energy, event topology, absorption, and direction information. We present the probability that each high energy event with deposited energy E dep >60 TeV in the HESE sample is Galactic, extragalactic, or background. Lastly, for Galactic models considered the Galactic fraction of the astrophysical flux has a best fit value of 1.3% and is <9.5% at 90\% CL. A zero Galactic flux is allowed at <1σ.
Neutrino Fluxes from NUHM LSP Annihilations in the Sun
We extend our previous studies of the neutrino fluxes expected from neutralino LSP annihilations inside the Sun to include variants of the minimal supersymmetric extension of the Standard Model (MSSM) with squark, slepton and gaugino masses constrained to be universal at the GUT scale, but allowing one or two non-universal supersymmetry-breaking parameters contributing to the Higgs masses (NUHM1,2). As in the constrained MSSM (CMSSM) with universal Higgs masses, there are large regions of the NUHM parameter space where the LSP density inside the Sun is not in equilibrium, so that the annihilation rate may be far below the capture rate, and there are also large regions where the capture rate is not dominated by spin-dependent LSP-proton scattering. The spectra possible in the NUHM are qualitatively similar to those in the CMSSM. We calculate neutrino-induced muon fluxes above a threshold energy of 10 GeV, appropriate for the IceCube/DeepCore detector, for points where the NUHM yields the correct cosmological relic density for representative choices of the NUHM parameters. We find that the IceCube/DeepCore detector can probe regions of the NUHM parameter space in addition to analogues of the focus-point strip and the tip of the coannihilation strip familiar from the CMSSM. These include regions with enhanced Higgsino-gaugino mixing in the LSP composition, that occurs where neutralino mass eigenstates cross over. On the other hand, rapid-annihilation funnel regions in general yield neutrino fluxes that are unobservably small.
The distribution of solar magnetic fluxes and the nonlinearity of stellar flux-flux relations
Synoptic maps for the 1975-1984 period are used to determine the time-dependent distribution function of magnetic flux densities in the solar atmosphere. The distribution function depends only on the global level of magnetic activity, and it is used to study how relations between magnetic flux densities and radiative flux densities from different temperature regimes in the outer atmosphere (derived from spatially resolved solar observations) transform into relations between surface-averaged flux densities. It is found that the transformation to surface-averaged fluxes preserves the power-law character of relations between radiative and magnetic flux densities for spatially resolved data.
Three-Dimensional Simulation of Volatile Organic Compound Mass Flux from the Vadose Zone to Groundwater
Low permeability layers of the vadose zone containing volatile organic compounds (VOCs) may persist as source zones for long time periods and may provide contamination to groundwater. At sites with low recharge rates, where vapor migration is the dominant transport process, the impact of vadose zone sources on groundwater may be difficult to assess. Typical assessment methods include one-dimensional numerical and analytical techniques. The one-dimensional approaches only consider groundwater coupling options through boundary conditions at the water table and may yield artificially high mass flux results when transport is assumed to occur by gas-phase diffusion between a source and an interface with a zero concentration boundary condition. Improvements in mass flux assessments for VOCs originating from vadose zone sources may be obtained by coupling vadose zone gas transport and dissolved contaminant transport in the saturated zone and by incorporating the inherent three-dimensional nature of gas-phase transport, including the potential of density-driven advection. This paper describes a series of three-dimensional simulations using data from the U.S. Department of Energy’s Hanford Site, where carbon tetrachloride is present in a low permeability zone about 30 m above the groundwater. Results show that, for most cases, only a relatively small amount of the contaminant emanating from the source zone partitions into the groundwater and that density-driven advection is only important when relatively high source concentrations are considered.
Comparison of the high temperature heat flux sensor to traditional heat flux gages under high heat flux conditions.
Four types of heat flux gages (Gardon, Schmidt-Boelter, Directional Flame Temperature, and High Temperature Heat Flux Sensor) were assessed and compared under flux conditions ranging between 100-1000 kW/m2, such as those seen in hydrocarbon fire or propellant fire conditions. Short duration step and pulse boundary conditions were imposed using a six-panel cylindrical array of high-temperature tungsten lamps. Overall, agreement between all gages was acceptable for the pulse tests and also for the step tests. However, repeated tests with the HTHFS with relatively long durations at temperatures approaching 1000ÀC showed a substantial decrease (10-25%) in heat flux subsequent to the initial test, likely due to the mounting technique. New HTHFS gages have been ordered to allow additional tests to determine the cause of the flux reduction.
Striation pattern of target particle and heat fluxes in three dimensional simulations for DIII-D
The application of resonant magnetic perturbations results in a non-axisymmetric striation pattern of magnetic field lines from the plasma interior which intersect the divertor targets. The impact on related particle and heat fluxes is investigated by three dimensional computer simulations for two different recycling conditions (controlled via neutral gas pumping). It is demonstrated that a mismatch between the particle and heat flux striation pattern (splitting vs. no splitting), as is repeatedly observed in ITER similar shape H-mode plasmas at DIII-D, can be reproduced by the simulations for high recycling conditions at the onset of partial detachment. These results indicate that a detailed knowledge of the particle and energy balance is at least as important for realistic simulations as the consideration of a change in the magnetic field structure by plasma response effects.
Measurement of the {sup 8}B solar neutrino flux with the KamLAND liquid scintillator detector
We report a measurement of the neutrino-electron elastic scattering rate from {sup 8}B solar neutrinos based on a 123 kton-day exposure of KamLAND. The background-subtracted electron recoil rate, above a 5.5-MeV analysis threshold is 1.49 {+-} 0.14(stat) {+-} 0.17(syst) events per kton-day. Interpreted as due to a pure electron flavor flux with a {sup 8}B neutrino spectrum, this corresponds to a spectrum integrated flux of 2.77 {+-} 0.26(stat) {+-} 0.32(syst) x10{sup 6} cm{sup -2}s{sup -1}. The analysis threshold is driven by {sup 208}Tl present in the liquid scintillator, and the main source of systematic uncertainty is due to background from cosmogenic {sup 11}Be. The measured rate is consistent with existing measurements and with standard solar model predictions which include matter-enhanced neutrino oscillation.
DCS - A high flux beamline for time resolved dynamic compression science – Design highlights
The Dynamic Compression Sector (DCS) beamline, a national user facility for time resolved dynamic compression science supported by the National Nuclear Security Administration (NNSA) of the Department of Energy (DOE), has recently completed construction and is being commissioned at Sector 35 of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The beamline consists of a First Optics Enclosure (FOE) and four experimental enclosures. A Kirkpatrick–Baez focusing mirror system with 2.2 mrad incident angles in the FOE delivers pink beam to the experimental stations. A refocusing Kirkpatrick–Baez mirror system is situated in each of the two most downstream enclosures. Experiments can be conducted in either white, monochromatic, pink or monochromatic-reflected beam mode in any of the experimental stations by changing the position of two interlocked components in the FOE. The beamline Radiation Safety System (RSS) components have been designed to handle the continuous beam provided by two in-line revolver undulators with periods of 27 and 30 mm, at closed gap, 150 mA beam current, and passing through a power limiting aperture of 1.5 x 1.0 mm{sup 2}. A novel pink beam end station stop [1] is used to stop the continuous and focused pink beam which can achieve a peak heat flux of 105 kW/mm{sup 2}. A new millisecond shutter design [2] is used to deliver a quick pulse of beam to the sample, synchronized with the dynamic event, the microsecond shutter, and the storage ring clock.
A novel approach to evaluate soil heat flux calculation: An analytical review of nine methods
Abstract There are no direct methods to evaluate calculated soil heat flux (SHF) at the surface ( G 0 ). Instead, validation and cross evaluation of methods for calculating G 0 usually rely on the conventional calorimetric method or the degree of the surface energy balance closure. However, there is uncertainty in the calorimetric method itself, and factors apart from G 0 also contribute to nonclosure of the surface energy balance. Here we used a novel approach to evaluate nine different methods for calculating SHF, including the calorimetric method and methods based on analytical solutions of the heat diffusion equation. The SHF ( G z ) measured by a self‐calibrating SHF plate at a depth of z = 5 cm below the surface (hereafter G m _5 cm ) was deployed as a reference. Each SHF calculation method was assessed by comparing the calculated G z at the same depth (hereafter G c _5 cm ) with G m _5 cm . The calorimetric method and simple measurement method performed best in determining G c _5 cm but still underestimated G m _5 cm by 19% during the daytime. Possible causes for this underestimation include errors and uncertainties in SHF measurements and soil thermal properties, as well as the phase lag between G c _5 cm and G m _5 cm . Our results indicate that the calorimetric method achieves the most accurate SHF estimates if self‐calibrating SHF plates are deployed at two depths (e.g., 5 cm and 10 cm), soil temperature and water content measurements are made in a few depths between the two plates, and soil thermal properties are accurately quantified.