At least 19 records

Investigation of Biomass Fouling on Screw Feeder in Preconversion of Pyrolysis

Biomass is a source of renewable energy and can undergo thermochemical processes to be converted into gaseous and liquid fuels. Thermal decomposition-induced biomass fouling on the screw feeder is a major challenge in preconversion of pyrolysis, leading to plugging of the feed line. Here, this work intends to gain fundamental understanding of the biomass fouling phenomena across the heat gradient on the screw feeder via a combination of materials characterization and thermal simulation. An actual screw feeder that failed because of biomass fouling was examined to reveal the deposit’s morphology, composition, and mechanical properties. Thermal simulations were developed for both the screw feeder and the wood particles being transported using a combined analytical and numerical approach. The simulated temperature profiles correlated well with the deposit observations, based on which potential mitigations were proposed from both the operation and screw design perspectives and supported by preliminary experimental validation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Generalized Analysis of Dynamic Flow Fouling on Heat Transfer Surfaces

Several energy applications involve flow of untreated heat transfer fluids that contain trace amounts of mineral salts, such as calcium carbonate and calcium sulfate, which show reverse solubility with temperature. The gradual accretion of these salts onto the heat transfer surfaces causes fouling that degrades thermal performance over time. While fouling of bare surfaces has been extensively studied, fouling of nonwetting superhydrophobic or liquid-infused surfaces is less understood, especially under dynamic flow conditions. This study presents a systematic experimental analysis to elucidate dynamic flow fouling of calcium carbonate and calcium sulfate on smooth, superhydrophobic and liquid-infused surfaces in a generalized manner. Here, copper tubes with modified inner surface wettability are fabricated and subjected to forced convection at different flow rates and fouling salt concentrations. Fouling characteristics of the two salts on the different surfaces are examined through microstructural analysis, and quantified in terms of asymptotic fouling resistance that measures the total extent of fouling, and a threshold time, which correlates to the onset of significant fouling. Using Taguchi design of experiments, the study reports, for the first time, closed-form analytical relationships for the asymptotic fouling thermal resistance and threshold time on the Reynolds number, dimensionless concentration of fouling agent and dimensionless infused liquid viscosity that represents the different surface types in a unified manner. It is shown that the analytical model accurately predicts the fouling characteristics in up to about 97% of the data, based on which contour maps of optimum surface designs for minimizing fouling resistance are presented. The results provide information on designing surfaces for reduced fouling or for estimating the fouling characteristics for a given surface in applications.

36 MATERIALS SCIENCE↗

Experimental Investigation of Polymer Induced Fouling of Heater Tubes in the First-Ever Polymer Flood Pilot on Alaska North Slope

Mineral fouling in heat exchangers has been extensively investigated by researchers in recent times. The oil and gas industry has a long history of fouling issues in production systems as a result of produced fluids treatment. Due to decline in production rates in oilfields new technologies are being developed and field tested in pilots. Polymer flooding is one such technology that involves addition of polymers to injection fluids to enhance oil production. A polymer flood pilot has been set up in the Schrader Bluff viscous oil reservoir at Milne Point field on the Alaska North Slope (ANS). The results from the pilot are encouraging, however a major concern of the operator is the influence of polymer on the production system after breakthrough, especially the fouling in heat exchangers. This study investigates the propensity of polymer fouling on the heater tubes as a function of different variables, with the ultimate goal of determining safe and efficient operating conditions. This work applies a multi-experimental approach to study the severity of polymer-induced fouling in both dynamic and static states of produced fluids as well as studying the stability of polymer solutions at different temperatures. A unique experimental setup was designed and developed in-house to simulate the fouling process on the heating tube. The influence of heating tube skin temperature, tube material, and polymer concentration on fouling tendency was investigated. Each test was run five times with the same tube, and in each run, the freshly prepared synthetic brine and polymer solution was heated from 77°F to 122°F to mimic field-operating conditions. The heating time and fouling amount were recorded for each run. Dynamic Scale Loop (DSL) tests were conducted to study fouling due to polymer at different temperatures (165°F to 350°F) in a dynamic state of fluid flow where the fluids mimic the residence time of fluids in the heat exchanger on the field pilot. Cloud point measurement has also been conducted to find the critical temperature at which the polymer in solution becomes unstable and precipitates out. The morphology and composition of the deposit samples were analyzed by environmental scanning electron microscopy (ESEM) and X-ray diffraction (XRD), respectively. It was found that the presence of polymer in produced fluids would aggravate the fouling issues on both carbon steel and stainless-steel surfaces at all tested skin temperatures. Only higher skin temperatures of 250°F and 350°F could cause polymer-induced fouling issues on the copper tube surface, and the fouling tendency increased with polymer concentration. At the lower skin temperatures of 165°F, no polymer-induced fouling was identified on the copper tube. A critical temperature that is related to the cloud point of the polymer solution was believed to exist, below which polymer-induced fouling would not occur, and only mineral scale was deposited but above which the polymer would aggravate the fouling issue. The cloud point of the tested polymer solution was determined to be between 220°F and 230°F. In the DSL tests it was found that at higher skin temperatures of 250°F and 350°F tube blocking was observed in the DSL tests whereas the tests at 165°F and 200°F did not show any tube blocking in the same time period. These experiments also manifested the influence of cloud point of the solution as deposit rate increased significantly in both carbon steel and stainless-steel tubes when the skin temperature was higher than the solution cloud point. The results of this study have provided guidance to the operator for the field-operations.

Dhaliwal, Anshul↗

Experimental Investigation of Polymer Induced Fouling of Heater Tubes in the First-ever Polymer Flood Pilot on Alaska North Slope

Polymer flooding has been validated in the lab and by successful applications in other countries, such as Canada and China, to be an effective EOR technique for heavy oil reservoirs. Currently, polymer flooding is being pilot tested for the first time in the Schrader Bluff viscous oil reservoir at Milne Point field on Alaska North Slope (ANS). One of the major concerns of the operator is the impact of polymer on the oil production system after polymer breakthrough, especially the polymer induced fouling issues in the heat exchanger. This study investigates the propensity of polymer fouling on the heater tubes as a function of different variables, with the ultimate goal of determining safe and efficient operating conditions. A unique experimental set-up was indigenously designed and developed to simulate the fouling process on the heating tube. The influence of heating tube skin temperature, tube material, and polymer concentration on fouling tendency was investigated. Under each test condition, the test was run five times with the same tube, and in each run, the freshly prepared synthetic brine and polymer solution were heated from 77°F to 122°F to mimic field operating conditions. The heating time and fouling amount were recorded for each run. The morphology and composition of the deposit samples were analyzed by environmental scanning electron microscopy (ESEM) and X-ray diffraction (XRD), respectively. It has been found that, in general, the presence of polymer in produced fluids would aggravate the fouling issues on both carbon steel and stainless steel surfaces at all tested skin temperatures (165°F, 250 °F and 350°F), but only higher skin temperatures of 250°F and 350°F could cause polymer induced fouling issues on the copper tube surface and the fouling tendency increased with polymer concentration. At the lower skin temperatures of 165°F, no polymer-induced fouling was identified on the copper tube. A critical temperature that is related to the cloud point of the polymer solution was believed to exist, below which polymer induced fouling would not occur and only mineral scale deposited, but above which the polymer would obviously aggravate the fouling issue. The heating efficiency of the tube would be reduced gradually as more fouling material accumulates on its surface. The ESEM results indicate that if polymer precipitated and deposited on the surface, it would bond to the mineral crystals to form a stronger three- dimensional network structure, and that is why the polymer induced fouling was tougher and more difficult to be removed from the tube surface. The XRD analysis results confirm that the presence of polymer in the fluids can enhance the mineral scale propensity. Overall, the study results have provided practical guidance to the field operator for the ongoing polymer flooding pilot test on ANS. This study may also prove to be valuable for other chemical EOR projects around the world.

Alaska North Slope↗

The effects of outdoor air-side fouling on frost growth and heat transfer characteristics of a microchannel heat exchanger: An experimental study

Air source heat pumps have the potential to efficiently heat and cool buildings, but their effectiveness in many climates is limited by frost growth on the outdoor heat exchanger in heating mode. These heat exchanger coils are also subject to fouling from fibers and particulates outdoors. Frost and fouling have each independently been studied extensively, and newly available research on fouling provides a method to realistically foul the air-side of coils in the laboratory. The current paper uses this method to conduct the first laboratory study of the important interactions between fouling and frost growth for a heat pump outdoor coil. A microchannel heat exchanger is tested clean and fouled, with variations in fouling level, humidity, and initial face velocity of air. Air flow rate is allowed to vary with resistance, and a surprising result is that light fouling increases heat transfer and frost growth rates, even with a 3.5% reduction in initial airflow caused by the fouling. However, heavier fouling decreases both rates. When frost growth is normalized to heat transfer, it is found to be increased by fouling; i.e. the coil’s sensible heat ratio decreases.

42 ENGINEERING↗

Novel nonwetting solid-infused surfaces for superior fouling mitigation

Fouling is a ubiquitous issue in several environmental and energy applications. Here we introduce novel nonwetting solid-infused surfaces (SIS) with superior anti-fouling characteristics that are durable than conventional nonwetting surfaces in a dynamic flow environment. A systematic study is presented to elucidate the fouling mitigation performance of SIS in comparison to lubricant-infused surface (LIS) and conventional smooth surface. Copper tubes with SIS, LIS or smooth inner walls are fabricated and subjected to accelerated calcium sulfate fouling in a flow fouling experimental setup. Fouling on the various surface types is quantified in terms of asymptotic fouling resistance, and the fundamental morphological differences in the interactions of the foulant and the various surface types are analyzed. Based on a systematic sweep of the parameter combinations using design of experiments and Taguchi analysis, an analytical dependence of asymptotic fouling resistance on the governing parameters namely, Reynolds number, foulant concentration and temperature is derived. The analytical model is shown to predict the asymptotic fouling resistance to within 20% accuracy with a 95% confidence. In addition, for the first time, the effects of shear durability on the fouling mitigation performance of LIS vis-à-vis SIS are studied. It is shown that the novel nonwetting SIS offers a robust option for superior fouling mitigation over LIS in the long run.

42 ENGINEERING↗

Calcium-organic matter fouling in nanofiltration: Synchrotron-based X-ray fluorescence and absorption near-edge structure spectroscopy for speciation

Calcium (Ca)-enhanced organic matter (OM) fouling of nanofiltration (NF) membranes leads to reduced flux during desalination and requires frequent cleaning. Fouling mechanisms are not fully understood, which limits the development of targeted fouling control methods. This study employed synchrotron-based X-ray fluorescence (XRF) and X-ray absorption near-edge structure (XANES) spectroscopy to quantify the spatial distribution and mass of Ca deposition as well as changes in the Ca coordination environment characteristic of specific fouling mechanisms, respectively. Bench-scale filtration experiments were performed using feed solutions containing Ca and ten different types of organic matter (OM), as well as the common scalants, calcium carbonate (CaCO 3 ) and calcium sulfate (CaSO 4 ). Osmotic backwash (OB) was performed at regular intervals for fouling control. Ca-OM aggregation resulted in greater flux decline and lower flux recovery during OB than Ca conditioning of membranes followed by filtration of feed solution with OM. Linear combination fitting (LCF) of XANES absorption spectra from fouled membranes indicated that Ca-OM aggregation preferentially occurred for OM types that exhibited both high carboxylic group and negative charge density. Consequently, these OM types exhibited greater deposition of Ca and TOC on the membrane surface when compared to other OM types. For the coexistence of scalants and OM, Ca speciation within the fouling layer was characteristic of both Ca bound to the membrane (i.e. potential bridging, charge screening) as well as Ca-OM aggregation and deposition mechanisms, while a range of crystal polymorphs were observed to occur simultaneously. XRF and XANES represent powerful tools for the elucidation of NF fouling mechanisms by quantification of Ca deposition as well as Ca speciation. Fouling control methods should target OM types with high carboxyl group density and negative charge to neutralize or eliminate interactions with Ca.

42 ENGINEERING↗

Effects of Temperature on Flow Fouling of Smooth and Nonwetting Surfaces

Mineral fouling (scaling) of heat transfer surfaces is a pervasive problem in heat exchangers, chemical reactors, and other equipment in energy, environmental, and process industrial applications. Many of the applications involve dynamic flow of fluids with the impurity minerals and, furthermore, operate at elevated temperature. Strategies to mitigate fouling under these conditions are of much value in industrial applications. This paper presents a comparative study of temperature-dependent mineral fouling deposition on smooth surfaces and nonwetting superhydrophobic and lubricant-infused surfaces under dynamic flow conditions. The surfaces are represented in a unified manner using the viscosity ratio of the infused material within the porous asperities on a surface to that of the flowing fluid such that the spectrum of surfaces from superhydrophobic to smooth is captured by the range of viscosity ratios from 0 to ∞. Using a forced convection experimental setup, deposition of calcium sulfate on the surfaces is quantified in terms of asymptotic fouling resistance over a range of temperature, Reynolds number, and mineral foulant supersaturation. Through a systematic set of accelerated fouling experiments, an empirical relationship for the asymptotic fouling resistance is developed in terms of Reynolds number, foulant concentration, temperature, and surface type. The empirical model is validated with a comprehensive set of experimental data from this study as well as from the literature. Optimum nonwetting surface designs for minimizing fouling resistance compared to conventional smooth surfaces are developed as a function of temperature. The results of the study offer insight into the temperature-dependent fouling of surfaces under flow conditions and a rational design of fouling-resistant nonwetting surfaces that can be readily translated to practice.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Linking water quality, fouling layer composition, and performance of reverse osmosis membranes

Fouling of polyamide membranes during reverse osmosis (RO) is a major challenge for adopting membrane technologies to treat highly contaminated waters, especially those containing organic foulants (e.g., natural organic matter (NOM), polysaccharides) and dominant cations (e.g., sodium, magnesium, calcium). Here, this work combines bench-scale membrane fouling experiments with detailed characterization of feedwater chemistry and fouling layer composition/morphology to reveal fundamental mechanisms of (in)organic fouling during RO. Divalent cations are shown to promote fouling by hydrophobic NOM containing aromatic and carboxyl groups, while NOM fouling in the presence of a monovalent cation, sodium, occurs by smaller fulvic acids containing larger fractions of carboxyl groups and other oxygen-rich moieties. Calcium-carboxyl bridging occurs in solution and near the membrane surface to induce NOM aggregation on nanometer length scales. In complex waters containing foulant mixtures, co-fouling by calcium-carboxyl bridging and CaCO 3 precipitation influence membrane performance at longer timeframes. However, the flux decline observed for the co-fouling mechanism was less significant than the sum of its parts, suggesting both synergistic and antagonistic fouling mechanisms should be considered in membrane design/operation. These results encourage the design of pretreatment processes to reduce concentrations of multivalent ions and hydrophobic NOM in RO feedwaters, and of membrane materials to limit attachment/deposition of aggregates to/on polyamide surfaces.

42 ENGINEERING↗

Crossflow membrane filtration system for operando fouling characterization using transmission x-ray scattering

Membrane-based separations are widely used for wastewater treatment due to their low cost and efficiency. However, membrane fouling, which is the unwanted deposition or attachment of contaminants on membrane surfaces and/or within membrane pores, remains a major challenge as it increases the mass transfer resistance and reduces membrane productivity. Membrane fouling is typically probed by macroscopic performance metrics, such as flux decline, and ex situ characterization. However, this does not capture the membrane and fouling layer evolution under operating conditions, potentially masking important mechanisms and nonequilibrium pathways that impact fouling. Here, we present a remotely controlled crossflow membrane system and a custom membrane cell for operando fouling characterization using transmission small/wide angle x-ray scattering (SAXS/WAXS). This approach allows direct observation of the nanoscale changes occurring at the membrane surface during pressurized water treatment processes, enabling a new way to understand the connections between dynamic fouling behaviors and membrane performance. Nanoparticle fouling of porous membranes during ultrafiltration was investigated using operando SAXS, and mineral scaling of reverse osmosis membranes was investigated using operando WAXS. Furthermore, this system allows for tracking membrane fouling in real time and under realistic conditions, providing fundamental physical insights into how water chemistry and operating conditions affect macroscopic membrane performance. Moreover, this system opens the door for future in situ and operando studies, and it serves as a testbed for evaluating novel materials/processes for membrane-based separations.

36 MATERIALS SCIENCE↗

A survey of gas-side fouling in industrial heat-transfer equipment

Gas-side fouling and corrosion problems occur in all of the energy intensive industries including the chemical, petroleum, primary metals, pulp and paper, glass, cement, foodstuffs, and textile industries. Topics of major interest include: (1) heat exchanger design procedures for gas-side fouling service; (2) gas-side fouling factors which are presently available; (3) startup and shutdown procedures used to minimize the effects of gas-side fouling; (4) gas-side fouling prevention, mitigation, and accommodation techniques; (5) economic impact of gas-side fouling on capital costs, maintenance costs, loss of production, and energy losses; and (6) miscellaneous considerations related to gas-side fouling. The present state-of-the-art for industrial gas-side fouling is summarized by a list of recommendations for further work in this area.

Marner, W. J.↗

Analysis of silica fouling on nonwetting surfaces

Ground water sources used as coolant fluids in a variety of thermal systems such as heat exchangers and power plant condensers contain silica particles that accrete on heat transfer surfaces over time leading to reduction in thermal performance, a problem that is particularly exacerbated with temperature. Nonwetting superhydrophobic, lubricant-infused, and a new class of solid-infused surfaces introduced in this work are candidates for fouling mitigation, by virtue of their water repellency, but little is known about fouling of silica on the surfaces, especially under dynamic flow conditions and as a function of temperature. This article presents, for the first time, a systematic study of dynamic flow fouling of silica on nonwetting surfaces vis-à-vis conventional copper surface over a temperature range 20–50°C. The mechanism of silica aggregate formation and its adherence to the different surfaces is elucidated by scanning electron microscope (SEM) imaging. Sigmoidal growth model is used to describe the time evolution of fouling thermal resistance and an Arrhenius model is presented for the temperature-dependent increase in the asymptotic fouling resistance on nonwetting and conventional surfaces alike. Lubricant-infused and solid-infused surfaces are shown to reduce fouling thermal resistance by up to 25% and 13%, respectively, compared to a conventional surface, whereas superhydrophobic surfaces lose their non-wettability under flow conditions, leading to an adverse increase in the fouling resistance by up to 13%. Considering the possible lubricant depletion in lubricant-infused surfaces over prolonged exposure to a flowing fluid, solid-infused surfaces present a robust alternative.

42 ENGINEERING↗

Mitigating municipal solid waste fouling in biofuel conversion via screw surface modifications

Here, municipal solid waste (MSW)'s 40–60 % carbon content makes it a feedstock for biofuel production via pyrolysis. One challenge in the conversion process is MSW fouling due to thermal decomposition. The accumulated deposit on the injection screw often leads to plugging and constriction. This study examined the morphology and composition of the MSW fouling deposit and conducted a thermal simulation to understand the temperature gradience of the injection screw. Surface modifications including smoothening and anti-adhesion coating were proposed for the injection screw to address the deposit problem. For evaluating the candidate mitigations, a bench-scale fouling test was developed with the gas environment, temperature, and sliding speed relevant to the contact interface between the MSW particles and the screw. Results suggested that a smoother screw surface could reduce the grip and a non-metallic coating with a lower surface energy could decrease adhesion, consequently leading to less fouling. Specifically, reducing the roughness from 2 to 0.6 and then to 0.2 μm proportionally decreased the amount of deposit, and the diamond-like-carbon, CrN, and NiCr–CrC composite coatings effectively hindered the fouling process. This study provides fundamental insights into the MSW fouling and proof-of-concept of potential mitigations through the screw surface modification.

09 BIOMASS FUELS↗

Comparative analysis of various pretreatments to mitigate fouling and scaling in membrane distillation

Membrane distillation (MD) has shown strong promise for treating hypersaline produced water (PW) streams. Scaling and fouling on the membrane surface, however, have been identified as major challenges for commercialization and widespread application. The focus of this study was to first identify the nature of foulants and scalants on the membrane surface and then investigate the pretreatment strategies that mitigate the extent of fouling and scaling on the membrane surface. Vacuum MD (VMD) was selected for this study because of its higher flux at more moderate feed temperatures that eventually leads better assessment of fouling and scaling on the membrane surface. VMD flux tests were carried out with three different real PW samples at total dissolved solids concentrations in the range of 120-160 g/L. It was found that an efficient pretreatment prior to MD is required to mitigate the fouling potential of the organic matter, mostly suspended constituents, in PW samples. Suspended organics fouled and quickly wetted the MD membrane. Major conventional treatments, including filtration, oxidation, coagulation, air floatation, and aeration were investigated to pretreat the PW before VMD tests. A comprehensive comparative analysis is presented showing that the ultrafiltration and coagulation pretreatments displayed the best performance in mitigating the fouling and scaling, while oxidative pretreatment was found to be effective in reducing the iron concentration to less than 5 ppm. The surface of scaled membranes was carefully characterized to further evaluate the performance of each pretreatment. The components that had the highest tendency to precipitate on the membrane surface were identified as strontium sulfate, calcium carbonate, sodium chloride, iron oxide, and silica. In closing, these findings are supported by thermodynamic estimation of the saturation index.

42 ENGINEERING↗

Analysis of fouling mechanism in ultrafiltration of produced water

Flux decline measurements provided insight into the fouling behavior of ultrafiltration (UF) membranes for produced water (PW) treatment. Three UF membranes were compared in terms of the rate and the intensity of fouling. The flux decline analysis showed the fouling transition from blocking mechanisms (i.e., complete and intermediate blocking as well as standard blocking) to cake formation occurs earlier for more permeable membranes. Lower trans-membrane pressure (TMP) of 0.1 bar led to particle accumulation on the membrane surface leading to cake formation as the predominant fouling mechanism. In higher TMP experiments, standard and intermediate blocking followed by cake formation were found to be apparent fouling mechanisms. Overall, for the membranes with higher permeabilities and for the filtrations with pre-filtered feed, faster transition to cake formation was observed primarily due to crowd out effect. By understanding membrane fouling and behavior, it is possible to mitigate performance losses in membrane-based technologies that could be used for the treatment of PW. Furthermore, this study provides information to identify blocking rate and intensity in various conditions for UF membranes when treating PW.

42 ENGINEERING↗