Search NASA⌕ Search

SEARCH · Search NASA

Results for “four-terminal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Outdoor Deployment Data for a Four-Terminal GaAs//Si Tandem Solar Mini-Module

This dataset contains the complete outdoor measurement and analysis data for a mechanically stacked, four-terminal (4T) gallium arsenide (GaAs)//silicon (Si) tandem solar mini-module deployed from October 2019 to January 2021 at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado, USA. The data support a performance modeling and degradation analysis framework for tandem photovoltaic devices, as described in the accompanying publication. The dataset includes: (1) current–voltage (J–V) characteristics of each sub-cell measured approximately every five minutes, with extracted performance parameters; (2) spectral irradiance from an EKO MS-710 WISER spectroradiometer, along with derived spectral mismatch ratios (SMR) and average photon energy (APE); (3) one-minute resolution meteorological data from the co-located SRRL weather station and GPS-derived precipitable water vapor (PWV); (4) pre-deployment laboratory characterization (external quantum efficiency, J–V curves, standard test conditions parameters); (5) outdoor-extracted temperature and PWV correction coefficients; and (6) PVcircuit equivalent-circuit simulation outputs used for model validation. Degradation rates of −4.1 ± 0.2 %/year (GaAs) and −2.5 ± 0.9 %/year (Si) were determined using a filtering and normalization methodology adapted for fixed-tilt tandem modules. All data are provided in open, portable formats (Apache Parquet, CSV, JSON) to enable full reproducibility of the published analysis.

14 SOLAR ENERGY↗

Four-terminal electrical testing device

The invention relates to a four-terminal electrical connector device for testing and measuring unknown resistances of initiators used for starting pyrotechnic events aboard the space shuttle. The testing device minimizes contact resistance degradation effects and so improves the reliability of resistance measurements taken with the device. Separate and independent voltage sensing and current supply circuits each include a pair of socket contacts for mating engagement with the pins of the initiator. The unknown resistance that is measured by the device is the resistance of the bridgewire of the initiator which is required to be between 0.95 and 1.15 ohms.

Robinson, Robert L.↗

Four-terminal connector for measuring resistance of a pyrotechnic initiator

A four-terminal electrical connector device (40) for testing and measuring unknown resistances of initiators (11) used for starting pyrotechnic events aboard a Space Transportation System. The testing device minimizes contact resistance degradation effects and so improves the reliability of resistance measurement taken with the device. Separate and independent voltage sensing (19) and current supply (20) circuits each includes a pair of socket contacts (13-16) for mating engagement with the pins (17,18) of the initiator. The unknown resistance that is measured by the device is the resistance of the bridgewire (23) of the initiator which is required to be between 0.95 and 1.15 ohms.

Robinson, Robert L.↗

Semiautomatic device tests components with biaxial leads

Semiautomatic device with a four-terminal network tests quantities of components having biaxial leads. The four-terminal network permits the testing of components in different environments. This device is easily modified for completely automatic operation.

Marshall, T. C.↗

Performance measurement of emerging 3- and 4-terminal tandem solar cells

Tandem solar cells are not limited to the conventional two-terminal (2-T) configuration. Multi-terminal designs like three-terminal (3-T) and four-terminal (4-T) devices have gained increasing attention in the PV community due to their relaxed current-matching requirement between subcells and their potential for enhanced energy yield. However, reliable and standardized methods for evaluating the performance of multi-terminal tandems remain underdeveloped. This work addresses this gap by providing comprehensive measurement guidelines tailored to these advanced configurations. We examine key coupling mechanisms between subcells, including the shared electrical load in 3-T devices and optical luminescent coupling in both 3-T and 4-T devices, to enable accurate and consistent performance evaluation. Furthermore, we propose two stabilized measurement methods for emerging 3-T tandem cells incorporating perovskite subcells: (1) a two-dimensional maximum-power-point tracking (MPPT) approach that continuously tracks both subcells' maximum power points (P MAX ) until convergence to stabilized outputs, and (2) a hybrid approach that combines MPPT for one subcell with stabilized current recording under fixed voltage biases near the P MAX of the other, allowing robust extraction of the overall stabilized P MAX (termed “MPPT + asymptotic P MA X scan” method). These methods directly address the dynamic current responses inherent to perovskite-containing tandems, providing a foundation for meaningful and reproducible performance comparisons.

14 SOLAR ENERGY↗

Technoeconomic analysis of perovskite/silicon tandem solar modules

Tandem photovoltaic (PV) modules offer an opportunity to improve the efficiency and energy yield of available solar resources compared with single-junction devices. Here, we present a cost model and sensitivity analysis of perovskite/silicon (Si) tandem modules to understand how design choices impact overall module costs. We find a minimum sustainable price (MSP) of $\$$0.428/W DC for our baseline two-terminal design and $\$$0.423/W DC for our baseline four-terminal design, each at a module efficiency of 25% and module production of 3 GW per year in the United States. We find that the choice of Si cell architecture, overall module efficiency, and factory throughput have the most significant impacts on cost and competitiveness. The dynamic model provided is designed for researchers, companies, and interested individuals to use and edit as needed to better understand the trade-offs among PV module technologies and enable targeted research to improve module design and fabrication.

14 SOLAR ENERGY↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems

A crucial requirement of the protection system for multi-terminal high-voltage DC (MTDC) transmission is that it is capable of selectively isolating the faulty area from the healthy part of the network using DC circuit breakers (DCCBs), while ensuring continuous operation of converter stations in the healthy part of the network. But in the half-bridge modular multilevel converters (HB-MMCs) based MTDC system, since HB-MMCs do not have fault current absorption capability, when a DC fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of the MMCs in the healthy part. To facilitate fault-ride-through capability of MTDC system, large DC reactors are often considered in series with DCCBs to reduce the rate of rise of the fault current and prevent blocking the MMCs in the healthy part of the DC networks; however, large DC reactors prohibitively increase the cost of the system, introduce stability issues and can create post-fault oscillations. This paper presents an adaptive fault current-limiting control method for MMCs to avoid their blocking and enable the continuous operation of the healthy part of MTDC systems. The method contains two parts: The first part is based on circulating current feedforward control, which emulates virtual reactors in each arm of an MMC, and is immediately activated when the fault current starts to increase to reduce the rate of rise of the fault current. The second part temporarily bypasses all the submodules when the fault current exceeds a preset threshold, complementing the fault current-limiting effect of the first part. Neither part requires fault detection signals, and they are automatically activated during faults. Simulation case studies of a four-terminal bipolar MMC-based high-voltage DC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Performance Modeling of Tandem Photovoltaics: A Yearlong Outdoor Degradation Analysis of a Ga⁢As//Si Minimodule

We present a performance modeling and degradation analysis framework for tandem photovoltaic modules, building upon established procedures for crystalline silicon devices and adapting them to account for the spectral sensitivity of multijunction technologies. The methodology employs filter criteria to select outdoor measurements close to standard test conditions (STC) under stable spectral and ambient conditions, followed by normalization of power production data with corrections for temperature, irradiance, and precipitable water vapor. We demonstrate this framework using a mechanically stacked four-terminal gallium arsenide (Ga⁢As) // silicon (Si) tandem solar minimodule deployed outdoors from October 2019 to January 2021 in Golden, Colorado, USA. We determined degradation rates of −4.1 ±0.2%/year for the Ga⁢As subcell and −2.5 ±0.9%/year for the Si subcell, with analysis of individual performance metrics indicating that packaging degradation, particularly delamination, was the dominant failure mode. Simulations using PVcircuit, an open-source equivalent-circuit solver, confirmed these findings. The presented methodology provides a reproducible foundation for performance modeling and degradation analysis of emerging tandem technologies.

14 SOLAR ENERGY↗

High-Voltage DC MULTI-terminal SIMulation (HVDC MULTISIM): Technical Program Summary

Expansion of the power grid in the USA is essential to fulfilling the rising energy demand of the country. In particular, the transmission grid, a network of electrical energy corridors that enable the flow of large amounts of energy from the point of generation to the point of consumption, needs significant expansion to cater to this growth of electrification. The current infrastructure is also dated, and any new transmission corridor should be based on a vision of building a modern infrastructure that is futureproof. High voltage DC (HVDC) transmission technology falls in this category: it is the most economical way to build large transmission lines and relies on sophisticated electronics and flexible controls, rather than just passive components like switchgear and transformers. This project is aimed at establishing the technical and economic feasibility of a network of HVDC lines that are interconnected to form a multi-terminal DC network. HVDC transmission is not a new technology and United States has a number of such lines; however, these are point to point transmissions and do not form a DC grid. Modeling and analyzing DC grids is challenging since there are no established modeling tools and the traditional ways of modeling AC grids fall short of providing the fidelity required the fast dynamics of the DC grid. This project aims to build a software-in-the-loop simulator for a multi-terminal HVDC grid, called MULTISIM and, establish new control and protection algorithms to operate such a connected DC system. NLR, a key partner, established the core framework of the MULTISIM simulator and validated its functionality. The GE Vernova team, created a full-scale model of a four-terminal HVDC network using PSCAD (Power Systems Computer Aided Design) software and established the baseline performance of the system during normal and fault operation. The project was started on 10/12024 with a kick-off meeting held on 12/11/2024 and ran through two quarters till termination. All the tasks, milestones and deliverables during this period were met. Several interim reports detailing the various tasks were submitted. The following sections provide details on the completed tasks till the project pause and termination after Q2.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analytical model for liquid rocket propellant feedline dynamics

A generalized analytical model and computer program have been developed to predict the frequency response of arbitrary liquid propellant feedline designs. The analytical model is based on an extension of an existing distributed parameter representation of a viscous fluid transmission line with laminar flow which was modified to include the effects of a turbulent mean flow. The effects of dissolved ullage gases, wall elasticity, localized gas or vapor bubbles, bellows, forced changes in length due to structural excitation, complex side branches, and structural mounting stiffness are also included. Each line component is written as a four-terminal, pressure-flow relationship in matrix form in the Laplace domain; the transfer function relating the pressure response at the line terminal (inducer inlet) to the external excitation is obtained in the computer program by sequential matrix substitution.

Holster, J. L.↗

Diode-quad bridge circuit means

A transducer and frequency discriminator circuit is described including a four-terminal circulating diode bridge, a first pair of capacitors connected in series across two terminals of the bridge, and a second pair of capacitors, or other impedance elements, connected in series across the other two terminals of the bridge. A source of balanced alternating electrical energy for energizing the circuit is coupled between the commonly connected plates of the first pair of capacitors and the commonly connected plates of the second pair of capacitors. Due to the operation of the diode bridge, the sum of the resultant charges developed on the first pair of capacitors is proportional to the relationship between the respective capacitors of the second pair, and consequently, an output voltage taken across the first pair of capacitors will be proportional to that relationship.

Harrison, D. R.↗

Improved acoustic viscosimeter technique

An improved technique has been developed for studies of the shear viscosity of fluids. It utilizes an acoustic resonator as a four-terminal electrical device; the resonator's amplitude response may be determined directly and simply related to the fluid's viscosity. The use of this technique is discussed briefly and data obtained in several fluids is presented.

Fisch, M. R.↗

Optimal design of high-efficiency tandem cells

Computer analysis indicates that a substantial increase in solar cell conversion efficiencies can be achieved by using two-cell, multi-bandgap tandem structures instead of single-junction cells. Practical AM1 efficiencies of about 30 percent at one sun and over 30 percent at multiple suns are to be expected. The further increases in efficiency calculated for a three-cell tandem structure are much smaller and may not justify the added complexity. For inexpensive two-cell tandem modules, Si is preferred for the bottom cell, and the top-cell material should have a bandgap of 1.75 to 1.80 eV. The GaAs-AlAs and GaAs-GaP systems are very attractive candidates for the top cell. Significant advances have been achieved in growing GaAs on Ge-coated Si substrates (for the two-terminal, two-cell structure) and in growing free-standing ultrathin GaAs layers (for the two-terminal or four-terminal structures). These advances should be transferable to the GaAs-AlAs and GaAs-GaP systems.

Fan, J. C. C.↗

Nondestructive characterization of RBSOA of high-power bipolar transistors

Reverse-bias safe operating area (RBSOA) of high-power Darlington transistors is characterized using a 120 A/1000 V nondestructive reverse-bias second breakdown tester designed and fabricated at Virginia Polytechnic Institute and State University. Elaborate RBSOA characteristics are generated with different forward/reverse base drives and collector current levels. The effects of elevated case temperature and second-base drive on RBSOA of four-terminal Darlington devices are also discussed.

Jovanovic, M. M.↗

Formula Gives Better Contact-Resistance Values

Lateral currents in contact strips taken into account. Four-terminal test structures added to intergrated circuits to enable measurement of interfacial resistivities of contacts between thin conducting layers. Thin-film model simplified quasi-two-dimensional potential model that accounts adequately for complicated three-dimensional, nonuniform current densitites. Effects of nonuniformity caused by lateral current flow in strips summarized in equivalent resistance Rs and voltage Vs.

Lieneweg, Udo↗