At least 19 records

New Design Yields Robust Large-Area Framing Camera

Framing cameras provide a discrete series of images over a short period of time in a manner that mimics a high-speed movie camera, but with individual shutter times that must be extremely short in order to capture freeze-frame images of rapidly evolving phenomena such as high-explosive shock-driven ejecta, dynamic compression of metals, and high-velocity fluid flow. The NNSS has designed and fielded a new, large-area, gated framing camera called Kraken. The camera design emphasized manufacturability and flexibility by improving imager yield and creating a camera architecture to shorten design cycles. Design strategies and field data are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Origin of the framing camera.

Framing cameras of rotating mirror type, discussing optical principles used in American, British and Russian high speed cameras developed since original NACA camera

FRAMING CAMERA↗

Origin of the framing camera.

Framing cameras of rotating mirror type, discussing optical principles used in American, British and Russian high speed cameras developed since original NACA camera

HIGH SPEED CAMERA↗

Solid-state framing camera with multiple time frames

A high speed solid-state framing camera has been developed which can operate over a wide range of photon energies. This camera measures the two-dimensional spatial profile of the flux incident on a cadmium selenide semiconductor at multiple times. This multi-frame camera has been tested at 3.1 eV and 4.5 keV. The framing camera currently records two frames with a temporal separation between the frames of 5 ps but this separation can be varied between hundreds of femtoseconds up to nanoseconds and the number of frames can be increased by angularly multiplexing the probe beam onto the cadmium selenide semiconductor.

36 MATERIALS SCIENCE↗

Experimental Evaluation of Neutron Induced Noise on Gated X-ray Framing Cameras

A micro-channel plate based temporally-gated x-ray camera (framing camera) is one of the most versatile diagnostic tools of inertial confinement fusion experiments; particularly for observation of the shape of x-ray self emission from compressed core of imploded capsules. However, components used in an x-ray framing camera have sensitivity to neutrons induced secondary radiations. On early low-yield capsule implosions at the National Ignition Facility (NIF), the expected neutron production is about 5 x 10{sup 14}. Therefore, the expected neutron fluence at a framing camera located {approx} 150 cm from the object is 2 x 10{sup 9} neutrons/cm{sup 2}. To obtain gated x-ray images in such harsh neutron environments, quantitative understanding of neutron-induced backgrounds is crucial.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Standard design for National Ignition Facility x-ray streak and framing cameras

The x-ray streak camera and x-ray framing camera for the National Ignition Facility were redesigned to improve electromagnetic pulse hardening, protect high voltage circuits from pressure transients, and maximize the use of common parts and operational software. Both instruments use the same PC104 based controller, interface, power supply, charge coupled device camera, protective hermetically sealed housing, and mechanical interfaces. Communication is over fiber optics with identical facility hardware for both instruments. Each has three triggers that can be either fiber optic or coax. High voltage protection consists of a vacuum sensor to enable the high voltage and pulsed microchannel plate phosphor voltage. In the streak camera, the high voltage is removed after the sweep. Both rely on the hardened aluminum box and a custom power supply to reduce electromagnetic pulse/electromagnetic interference (EMP/EMI) getting into the electronics. In addition, the streak camera has an EMP/EMI shield enclosing the front of the streak tube.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating the relationship between noise transfer inside the x-ray framing cameras and their imaging ability

We apply a cascaded linear model analysis to a micro-channel plate x-ray framing camera. We establish a theoretical expression of the Noise Power Spectrum (NPS) at the detector’s output and assess its accuracy by comparing it to the NPS of Monte Carlo simulations of the detector’s response to a uniform illumination. We also reflect that fitting the NPS of experimental data against a parametric model based on this expression can yield valuable information on the imaging ability of framing cameras, offering an alternative method to the usual avenue employed to measure their modulation transfer functions.

25 ENERGY STORAGE↗

Imaging Asteroid 4 Vesta Using the Framing Camera

The Framing Camera (FC) onboard the Dawn spacecraft serves a dual purpose. Next to its central role as a prime science instrument it is also used for the complex navigation of the ion drive spacecraft. The CCD detector with 1024 by 1024 pixels provides the stability for a multiyear mission and its high requirements of photometric accuracy over the wavelength band from 400 to 1000 nm covered by 7 band-pass filters. Vesta will be observed from 3 orbit stages with image scales of 227, 63, and 17 m/px, respectively. The mapping of Vesta s surface with medium resolution will be only completed during the exit phase when the north pole will be illuminated. A detailed pointing strategy will cover the surface at least twice at similar phase angles to provide stereo views for reconstruction of the topography. During approach the phase function of Vesta was determined over a range of angles not accessible from earth. This is the first step in deriving the photometric function of the surface. Combining the topography based on stereo tie points with the photometry in an iterative procedure will disclose details of the surface morphology at considerably smaller scales than the pixel scale. The 7 color filters are well positioned to provide information on the spectral slope in the visible, the depth of the strong pyroxene absorption band, and their variability over the surface. Cross calibration with the VIR spectrometer that extends into the near IR will provide detailed maps of Vesta s surface mineralogy and physical properties. Georeferencing all these observation will result in a coherent and unique data set. During Dawn s approach and capture FC has already demonstrated its performance. The strong variation observed by the Hubble Space Telescope can now be correlated with surface units and features. We will report on results obtained from images taken during survey mode covering the whole illuminated surface. Vesta is a planet-like differentiated body, but its surface gravity and escape velocity are comparable to those of other asteroids and hence much smaller than those of the inner planets or

Keller, H. Uwe↗

Development of a dual MCP framing camera for high energy x-rays

Recently developed diagnostic techniques at LLNL require recording backlit images of extremely dense imploded plasmas using hard x-rays, and demand the detector to be sensitive to photons with energies higher than 50 keV [R. Tommasini et al., Phys. Phys. Plasmas 18, 056309 (2011); G. N. Hall et al., “AXIS: An instrument for imaging Compton radiographs using ARC on the NIF,” Rev. Sci. Instrum. (these proceedings)]. To increase the sensitivity in the high energy region, we propose to use a combination of two MCPs. The first MCP is operated in a low gain regime and works as a thick photocathode, and the second MCP works as a high gain electron multiplier. We tested the concept of this dual MCP configuration and succeeded in obtaining a detective quantum efficiency of 4.5% for 59 keV x-rays, 3 times larger than with a single plate of the thickness typically used in NIF framing cameras.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Non-gain microchannel plate gated framing camera

An x-ray framing camera using a non-gain microchannel plate (MCP) is reported in this article. The advantage of the non-gain MCP is the less transit time spread. The non-gain MCP gated framing camera has four microstrip line cathodes with 6 mm in width. The time domain reflectometry curves of the four microstrip lines are measured, which show that the characteristic impedance of each microstrip line is about 17 {Omega}. While the photocathode is driven by the gating electrical pulse with width of 125 ps and amplitude of -1.48 kV with -400 V bias, the measured exposure time of this camera is about 72 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial Demonstration of 9-MHz Framing Camera Rates on the FAST UV Drive Laser Pulse Trains

We report the configuration of a Hamamatsu C5680 streak camera as a framing camera to record transverse spatial information of green-component laser micropulses at 3- and 9-MHz rates for the first time. The latter is near the time scale of the ~7.5-MHz revolution frequency of the Integrable Optics Test Accelerator (IOTA) ring and its expected synchroton radiation source temporal structure. The 2-D images are recorded with a Gig-E readout CCD camera. We also report a first proof of principle with an OTR source using the linac streak camera in a semi-framing mode.

43 PARTICLE ACCELERATORS↗

Advances in x-ray framing cameras at the National Ignition Facility to improve quantitative precision in x-ray imaging

We describe an experimental method to measure the gate profile of an x-ray framing camera and to determine several important functional parameters: relative gain (between strips), relative gain droop (within each strip), gate propagation velocity, gate width, and actual inter-strip timing. Several of these parameters cannot be measured accurately by any other technique. This method is then used to document cross talk-induced gain variations and artifacts created by radiation that arrives before the framing camera is actively amplifying x-rays. Electromagnetic cross talk can cause relative gains to vary significantly as inter-strip timing is varied. This imposes a stringent requirement for gain calibration. If radiation arrives before a framing camera is triggered, it can cause an artifact that manifests as a high-intensity, spatially varying background signal. Furthermore, we have developed a device that can be added to the framing camera head to prevent these artifacts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental study of neutron induced background noise on gated x-ray framing cameras

A temporally gated x-ray framing camera based on a proximity focus microchannel plate is one of the most important diagnostic tools of inertial confinement fusion experiments. However, fusion neutrons produced in imploded capsules interact with structures surrounding the camera and produce background to x-ray signals. To understand the mechanisms of this neutron induced background, we tested several gated x-ray cameras in the presence of 14 MeV neutrons produced at the Omega laser facility. Differences between background levels observed with photographic film readout and charge-coupled-device readout have been studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid-state framing camera operating in interferometric mode

A high speed solid-state framing camera has been created which can operate in interferometric mode. This camera measures the change in the index of refraction of a semiconductor when x-rays are incident upon it. This instrument uses an x-ray transmission grating/mask in front of the semiconductor to induce a corresponding phase grating in the semiconductor which can then be measured by an infrared probe beam. The probe beam scatters off of this grating, enabling a measure of the x-ray signal incident on the semiconductor. In this specific instrument, the zero-order reflected probe beam is attenuated and interfered with the diffracted orders to produce an interferometric image on a charge coupled device camera of the phase change induced inside the semiconductor by the incident x-rays.

74 ATOMIC AND MOLECULAR PHYSICS↗

Coincidence ion imaging with a fast frame camera

A new time- and position-sensitive particle detection system based on a fast frame CMOS (complementary metal-oxide semiconductors) camera is developed for coincidence ion imaging. The system is composed of four major components: a conventional microchannel plate/phosphor screen ion imager, a fast frame CMOS camera, a single anode photomultiplier tube (PMT), and a high-speed digitizer. The system collects the positional information of ions from a fast frame camera through real-time centroiding while the arrival times are obtained from the timing signal of a PMT processed by a high-speed digitizer. Multi-hit capability is achieved by correlating the intensity of ion spots on each camera frame with the peak heights on the corresponding time-of-flight spectrum of a PMT. Efficient computer algorithms are developed to process camera frames and digitizer traces in real-time at 1 kHz laser repetition rate. We demonstrate the capability of this system by detecting a momentum-matched co-fragments pair (methyl and iodine cations) produced from strong field dissociative double ionization of methyl iodide.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗