Search NASA⌕ Search

SEARCH · Search NASA

Results for “freezers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Final Scientific/Technical Report-FREE-piston Zero Emissions Refrigerator (FREEZER)

The FREE-piston Zero Emissions Refrigerator (FREEZER™) is a natural refrigerant Stirling-cycle cooler developed by AMSC in partnership with Heatcraft, targeted as a replacement refrigeration system for walk-in coolers or freezers found commonly in restaurants, convenience stores, supermarkets, etc. The FREEZER™, combined with a closed-loop CO2 heat-transfer system, had the goal to provides an efficient (Target COP = 1.4), zero ODP (Ozone Depletion Potential) and near zero GWP (Global Warming Potential) refrigeration solution with no synthetic, flammable, or toxic refrigerants. Other near zero GWP refrigeration systems do not exist at the scale and performance level of FREEZER. ARPA-E Continuation Funding enabled the design and fabrication of one Advanced Development Unit (ADU) cooler and two Field Test Unit (FTU) coolers, and a new revised Field Test Unit (new FTU). Heatcraft was to extensively test the various coolers at their facilities, which closely simulate real-world conditions. The original plan was to install and operate FREEZER FTUs alongside a traditional cooling solution at one or more customer locations to obtain data on direct performance comparisons with existing commercial refrigeration systems. Success in this FREEZER refinement and field-test project will establish the basis for a new class of environmentally friendly refrigeration systems that will revolutionize the industry. The hardware developed under the program is shown below in Figure 1. Five Stirling-cycle machines were built within the program, with a sixth cooler still under construction. The original DU and the ADU coolers met the performance target with a coefficient of performance (COP) of 1.2. The FTU was underperforming during the initial tuning of the free-piston Stirling cycle dynamics when there was a catastrophic failure of the fasteners on pressure boundary. This caused a pause to the program while the failure mechanism was investigated. The root cause was an inadequate flange design that allowed an excessive cyclic loading on the fasteners, leading to a fatigue failure. It was determined that existing FTU design could not be reasonably salvaged in a safe manner, and that fact, combined with the lower-than-expected performance of the new experimental heat exchanger modules lead to the design of the “new FTU” with a more conventional shell-and-tube heat exchanger design which should get close to the design target COP of 1.4, but have a higher overall machine cost. The program ran out of time before the fabrication of the new FTU was completed, but AMSC is still working on the cooler, with the majority of the parts fabricated, and hopes to have the unit under test sometime in early 2022, after which it will be shipped to Heatcraft for additional testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Investigation on Cooling performance of A Thermoelectric Freezer

Thermoelectric heat pumps (TEHPs) have found widespread use in the electronics cooling industry and portable refrigerators. However, there has been a lack of extensive research on the application of TEHPs in low-temperature refrigeration settings. To address this gap, various configurations of TEHPs were fabricated to assess their suitability for freezer applications. Key parameters such as cooling capacity and system performance of the TEHPs were crucial in evaluating these configurations. Three configurations, each with different numbers of cooling units and fan arrangements, were tested using a 300-liter freezer prototype under typical room conditions (21°C). A cooling unit is comprised of two-stage thermoelectric modules, an aluminum plate fin heat exchanger sink with fans positioned either on top or directing airflow through the center, and a cooling block with circulating icy water for heat dissipation. Across all configurations, the minimum temperature inside the freezer cabinet reached -16.0°C. The cooling capacity peaked at 74.7 W, with the thermoelectric coefficient of performance (COP) reaching a maximum of 0.45. System COP ranged from 0.23 to 0.28. Minimum TE power consumption was recorded at 138.8 W, with TE system power consumption at 174.4 W, indicating feasibility for practical residential freezer applications. This investigation lays the foundation for integrating TE freezers with ice thermal storage systems.

Hu, Yifeng↗

Improving the energy efficiency of a refrigerator-freezer through the use of a novel cabinet/door liner based on polylactide biopolymer

This paper presents the energy savings potential of a newly developed liner applied on the foam insulation used in refrigerator and freezer cabinets, compared with using a more commonly used liner made from high-impact polystyrene. The new polylactic acid polymer liner is made from renewable feedstock such as carbon found in plant sugars. The energy use over the life of refrigerator and freezer is calculated using the Energy-Efficient Refrigerator Analysis program developed by the United States Department of Energy to estimate the energy savings potential of various technology option upgrades (cabinet and refrigeration system) for rulemaking purposes. The simulation results show that energy savings from implementing the Ingeo liner range from 818 to 1395tkWh (7.3–12.5% of total energy use) over a 15-year period. In addition to the energy savings, the slower increase in the thermal conductivity of the insulation could allow the compressor to run fewer hours per year compared with a case in which the foam thermal conductivity increases rapidly. This change could increase the life of the compressor and the refrigerators and freezers. As a result, this study does not attempt to quantify the impact of slower foam aging on the compressor life.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Market Assessment for Residential Refrigerator-Freezer with Novel Rotating Heat Exchanger

Despite a steady record of energy efficiency improvements in residential refrigerators and freezers over recent decades, these products still account for 4% of the site energy consumption for the average U.S. household. The Oak Ridge National Laboratory (ORNL) – along with partners Sandia National Laboratories (SNL) and the University of Maryland – are pursuing further efficiency improvements in this market sector by using a novel/prototype rotating heat exchanger (RHX) based on a Sandia Cooler technology as an evaporator in a residential refrigerator-freezer. The purpose of this study is to investigate the market potential of refrigerator-freezer products equipped with RHX evaporators in the United States, including projections of maximum annual market share and unit shipments and maximum direct and indirect job creation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Improved Performance of Polyurethane Foam Insulation Using Ingeo Biopolymer Liners and its Impact on Energy Efficiency of Refrigerator and Freezers

This paper compares the effect of isothermal aging of the thermal conductivity of polyurethane foam in simulated refrigerator-freezer panels made from polylactic acid biopolymer from NatureWorks (IngeoTM) and high-impact polystyrene. Specimens were aged at room temperature and thermal conductivity measurements were made at 10°C over a period of 2.4 years. The energy use over the life of refrigerator-freezer is also calculated using the Energy-Efficient Refrigerator Analysis program which was developed by the United States Department of Energy to estimate the energy savings potential of various technology option upgrades (cabinet and refrigeration system) for rulemaking purposes. The results show that energy savings from implementing the Ingeo liner range from 818 to 1395 kWh (7 to 13% of total energy use) over a 15-year period.

Hossieny, Nemat↗

Ultra-Low-Temperature Laboratory Freezer Specification

This specification provides a description of required performance characteristics resulting in increased energy savings for ultra-low-temperature freezers (ULTs) in laboratories.

Refrigeration, ultra-low-temperature laboratory fr↗

Fort Meade demonstration test LEDS in freezer rooms, fiber optics in display cases

Demonstration projects at Fort George G. Meade, MD, substituted LED lighting for incandescent bulbs in commisary wal-in freezers and fiber optic lighting in reach-in display cases. The goal was to reduce energy consumption and the results were positive. Journal article published in Public Works Digest

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Note: A microfluidic freezer based on evaporative cooling of atomized aqueous microdroplets

We report for the first time water-based evaporative cooling integrated into a microfluidic chip for temperature control and freezing of biological solution. We opt for water as a nontoxic, effective refrigerant. Aqueous solutions are atomized in our device and evaporation of microdroplets under vacuum removes heat effectively. We achieve rapid cooling (−5.1 °C/s) and a low freezing temperature (−14.1 °C). Using this approach, we demonstrate freezing of deionized water and protein solution. Our simple, yet effective cooling device may improve many microfluidic applications currently relying on external power-hungry instruments for cooling and freezing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cost-Benefit Analysis for Energy Efficient Refrigerators and Freezers in Uganda

Refrigeration appliances and equipment available on the market are manufactured with a wide range of energy performance. The goal of this report is to perform a cost-benefit analysis, providing policy recommendations to develop standards and labels for refrigerators in Uganda: in particular, an analysis of the cost-effectiveness of adopting the UNEP U4E MRG for refrigerators given the local context in Uganda.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Living and Working in the Freezer

Very little data of any kind exists from the early spring in the Arctic. The reason? It's extremely cold and that makes it difficult to survive, let alone conduct science. From March through the end of April, 2011, scientists from around the world braved temperatures of -48°C in the high Canadian Arctic in the name of science. At the Catlin Arctic Survey's floating 'Ice Base' off Ellef Ringnes Island, Dr. Victoria Hill was investigating how organic material in fresh water near the surface of the ocean may be trapping heat from the sun, causing the upper ocean layers to warm. This is a very new area of research and this mechanism represents a key uncertainty in accurate modeling of ice thickness and upper ocean heat content. In this presentation Dr. Hill will talk about living and working at the ice base and discuss preliminary data from the expedition.

54 ENVIRONMENTAL SCIENCES↗

U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys

Amazon Mechanical Turk was used, for the first time, to collect statistically representative survey data from U.S. households on the presence, number, type and usage of refrigerators, freezers, and various “miscellaneous” refrigeration products (wine/beverage coolers, residential icemakers and non-vapor compression refrigerators and freezers), along with household and demographic information. Such products have been poorly studied to date, with almost no information available about shipments, stocks, capacities, energy use, etc. A total of 9,981 clean survey responses were obtained from five distinct surveys deployed in 2012. General refrigeration product survey responses were weighted to demographics in the U.S. Energy Information Administration’s Residential Energy Consumption Survey 2009 dataset. Miscellaneous refrigeration product survey responses were weighted according to demographics of product ownership found in the general refrigeration product surveys. Model number matching for a portion of miscellaneous refrigeration product responses allowed validation of refrigeration product characteristics, which enabled more accurate estimates of the penetrations of these products in U.S. households. We estimated that there were 12.3±1.0 million wine/beverage coolers, 5.5(–3.5,+3.2) million residential icemakers and 4.4(–2.7,+2.3) million non-vapor compression refrigerators in U.S. households in 2012. (All numerical results are expressed with ranges indicating the 95% confidence interval.) No evidence was found for the existence of non-vapor compression freezers. Moreover, we found that 15% of wine/beverage coolers used vapor compression cooling technology, while 85% used thermoelectric cooling technology, with the vast majority of thermoelectric units having capacities of less than 30 wine bottles (approximately 3.5 cubic feet). No evidence was found for the existence of wine/beverage coolers with absorption cooling technology. Additionally, we estimated that there were 3.6±1.0 million hybrid refrigerator-wine/beverage coolers and 0.9±0.5 million hybrid freezer-wine/beverage coolers in U.S. households. We also obtained estimates of miscellaneous refrigeration product capacities, lifetimes, purchase and installation costs, repair frequencies and costs, and maintenance costs. For wine/beverage coolers, we also obtained information on the penetration of built-in units, AC/DC operating capability, the use of internal lights, and distributions of door opening frequencies. This information is essential to develop detailed estimates of national energy usage and life-cycle costs, and would be helpful in obtaining information on other plug-load appliances. Additional information not highlighted in the main report was presented in Appendices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗