Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency standard microwave cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High frequency gravitational wave sensing with superconducting microwave cavities

A promising way to probe physics beyond the Standard Model is to search for gravitational wave (GW) signals at high frequencies where known astrophysical sources can not obscure the signal. Similar to the search for dark matter, microwave cavity resonators can be used to detect faint effects from GWs. We will report on the progress of our project to operate such a detector and highlight improvements we are planning in the future. This includes quantum enhancement techniques like vacuum squeezing which will allow future detectors to operate beyond the standard quantum limit.

Marconato, Giovanni [Hamburg U.]↗

Design concept for the microwave interrogation structure in PARCS

In this paper we will describe key aspects of the conceptual design of the microwave interrogation structure in the laser-cooled cesium frequency standard that is part of the Primary Atomic Reference Clock in Space (PARCS) experiment.

frequency standard phase shift microwave cavity↗

Communications elements research

Radio frequency techniques, microwave thermal noise standards, radio frequency breakdown in coaxial transmission lines, and coaxial cavity radiator development

Source record↗

Precision timekeeping using a small passive hydrogen maser

The timekeeping ability of a prototype passive hydrogen maser which is a factor of 5 smaller in size, weight, and cost than any previously designed, was compared to UTC (NBS) based on 10 cesium frequency standards including a large primary standard, NBS-4. The frequency of the prototype was monitored as a function of source pressure, cavity temperature, microwave power, modulation width, and magnetic field. Based on these measurements, a frequency stability of better than 6 x 10 to the -15 power was expected, implying a timekeeping ability of order 0.5 ns/day. Measurements vs UTC(NBS) indicate a joint timekeeping a stability of order 1.2 ns/day. Simultaneous measurements made between NBS-4, UTC(6600), and the small passive me maser show peak to peak time variations of the small maser vs UTC(6600) was 10 ns for the full 32 days if the average rate and drift are considered. Frequency stability of the small prototype vs UTC (NBS) was to 1.1 x 10 to the -14th power for tau = 1 to 8 days.

Walls, F. L.↗

The status of cesium beam frequency standards

There has been a lot of progress in cesium beam frequency standards in the last few years some of which will be reported here. Optical pumping is being pursued actively in a number of laboratories. Optically slowed and cooled beams have been demonstrated as well as traps for cold neutral atoms. The microwave cavity performance with regard to local phase shift at the beam holes was improved by use of carefully designed and built ring structures for the cavity ends. Work is being done on improvements in electronics with some emphasis on use of digital circuitry and microprocessors. The frequency pulling due to microwave Delta M = +/- 1 transitions (Ramsey pulling) was analyzed and shown to be important. Status of cesium beam frequency standards in some of the laboratories as well as some of the commercial work is discussed. Optical pumping and detection are discussed.

Cutler, Leonard S.↗

Effect of thermal cycling on stress in metallic films on ceramic substrates

The hydrogen maser is the most stable frequency standard currently available for averaging intervals of hours to weeks. A major contributor to maser frequency variations is the maser's microwave resonant cavity: by means of the cavity pulling effect, a change in the cavity's resonance frequency produces a proportional change in the maser's output frequency. To minimize variations in the cavity's dimensions, and thus in its resonance frequency, maser cavities are often constructed of a low-expansivity glass-ceramic material coated on its surface with a conductive metallic film. It was previously shown that silver films like those used in SAO maser cavities develop tensile stress when cooled to room temperature after being fired onto the cavity, and that the stress in such films relaxes with time at a rate proportional to the level of stress. Stress relaxation in maser cavity coatings can alter the shape, and hence the resonance frequency, of the cavity, resulting in a slow variation in the maser's output frequency. The possibility was investigated of reversing the initial tensile stress by precooling the coated cavity material. It was hypothesized that cooling the material well below its normal working temperature and then warming it to its normal temperature would result in a lower tensile stress or even a compressive stress. Under such a condition stress relaxation, and thus any consequent frequency drifts, might be reduced or reversed.

Mattison, Edward M.↗

Stimulated Emission of Signal Photons from Dark Matter Waves

The manipulation of quantum states of light has resulted in significant advancements in both dark matter searches and gravitational wave detectors. Current dark matter searches operating in the microwave frequency range use nearly quantum-limited amplifiers. Future high frequency searches will use photon counting techniques to evade the standard quantum limit. We present a signal enhancement technique that utilizes a superconducting qubit to prepare a superconducting microwave cavity in a nonclassical Fock state and stimulate the emission of a photon from a dark matter wave. By initializing the cavity in an | n = 4 ⟩ Fock state, we demonstrate a quantum enhancement technique that increases the signal photon rate and hence also the dark matter scan rate each by a factor of 2.78. Using this technique, we conduct a dark photon search in a band around 5.965 GHz ( 24.67 μ eV ), where the kinetic mixing angle ε ≥ 4.35 × 10 − 13 is excluded at the 90% confidence level. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum metrology of low-frequency electromagnetic modes with frequency upconverters

We present the RF Quantum Upconverter (RQU) and describe its application to quantum metrology of electromagnetic modes between dc and the very high frequency band (VHF) ( ≲ 300 MHz). The RQU uses a Josephson interferometer made up of superconducting loops and Josephson junctions to implement a parametric interaction between a low-frequency electromagnetic mode (between dc and VHF) and a mode in the microwave C Band ( ∼ 5 GHz), analogous to the radiation pressure interaction between electromagnetic and mechanical modes in cavity optomechanics. We analyze RQU performance with quantum amplifier theory and show that the RQU can operate as a quantum-limited op-amp in this frequency range. It can also use nonclassical measurement protocols equivalent to those used in cavity optomechanics, including back-action evading (BAE) measurements, sideband cooling, and two-mode squeezing. These protocols enable experiments using dc VHF electromagnetic modes as quantum sensors with sensitivity better than the standard quantum limit (SQL). We demonstrate signal upconversion from low frequencies to the microwave C band using an RQU and show a phase-sensitive gain (extinction ratio) of 46.9 dB , which is a necessary step towards the realization of full BAE. Published by the American Physical Society 2025

Kuenstner, Stephen E. (ORCID:0000000346128846)↗

Quantum Sensing Experiments at SQMS

The Superconducting Quantum Materials and Systems (SQMS) Center, led by Fermi National Accelerator Laboratory, is one of five U.S. Department of Energy-funded research centers dedicated to advancing quantum computing and quantum sensing. SQMS leverages its expertise in superconducting radio-frequency (SRF) cavities and transmon qubits to develop sensitive quantum sensors to probe fundamental physics. This presentation will highlight the progress and innovations in SQMS’s quantum sensing thrust, with a particular focus on searches for particles beyond the Standard Model, dark matter candidates, and gravitational waves. Recent developments include the search for dark photon dark matter using transmon qubits and widely tunable superconducting cavities (4 GHz–7 GHz), a quantum-enhanced axion dark matter search employing an itinerant single microwave photon counter, and efforts to detect low-mass axions and high-frequency gravitational waves using multimode superconducting cavities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Highly Stable Microwave Resonator

Superconducting walls on sapphire-filled cavity make low-loss device. Improved microwave resonant cavity consists of sapphire cylinder coated with thin film of superconducting lead. Operated well below superconducting transition temperature at 1.5K, cavity demonstrated superior frequency stability and quality factor. Cavity frequency highly stable and therefore suitable for use in standard frequency generators and filters.

Strayer, Donald M.↗

Development of a cryogenic hydrogen maser at the NPL

A prototype Cold Hydrogen Maser (CHM) was being developed for the past year. The features of this CHM, which is designed to operate initially at 4.2 K, are the use of low loss alumina, and later sapphire, in the fabrication of the microwave cavity; possible use of superconductors for shielding; use of a cryogenic amplifier; possible coating material; and a reliable RF discharge circuit for the dissociation of hydrogen. A numerical simulation was performed to find the dimensions of the microwave cavity for the TE011 mode and the model was confirmed experimentally. The system will be used to test various wall coatings adsorbed on top of a PTFE buffer underlayer. The CHM is expected to be used as a flywheel frequency standard at the NPL with medium-term stability of one part in 10(exp 14) or better.

Mossavati, R.↗

Cosmic Axion Background detection using resonant cavity arrays

The axion is a well-motivated and generic extension of the Standard Model. If produced in the early universe, axions may still be relativistic today, forming a Cosmic Axion Background (CaB) potentially detectable in direct detection experiments. Although CaB is expected to be broadband, which makes it challenging to be detected, a high-quality-factor microwave cavity acts as a narrowband filter with response peaked at its resonant frequency. We propose a new strategy using multi-cavity arrays to distinguish signal from background noise by exploiting spatial correlations of the axion-induced electric field which are set by the cavity quality factor. We compute the two-point correlation function for electric fields in spatially separated cavities sourced by an isotropic CaB. Analyzing various cavity geometries, we find that stacked, wide-base cavity arrays offer coherent enhancement of the axion signal. We apply our formalism to prospective upgrades of the ADMX experiment, including configurations with four and eighteen coupled cavities. Although these arrays do not achieve a coherent enhancement, optimizing the geometry could potentially yield an $\mathcal{O}(1)$ improvement in the sensitivity to the CaB.

Axions and ALPs↗

Tuning Concept for Resonant Cavities

Deviations from resonance detected by sampling phases. Automatic tuner feedback control system derives error signal from E and H plane probe signals. Control objective to maintain phase difference between E and H at 90 degrees. Technique estimated to sensitive to fractional frequency deviation of about 5 X 10-16 and applicable not only to masers but also other microwave elements, including klystrons, general purpose oscillators, and frequency standards.

Sydnor, R. L.↗

Accurate Measurements of the Dielectric Constant of Seawater at L Band

This paper describes measurements of the dielectric constant of seawater at a frequency of 1.413 GHz, the center of the protected band (i.e., passive use only) used in the measurement of sea surface salinity from space. The objective of the measurements is to accurately determine the complex dielectric constant of seawater as a function of salinity and temperature. A resonant cylindrical microwave cavity in transmission mode has been employed to make the measurements. The measurements are made using standard seawater at salinities of 30, 33, 35, and 38 practical salinity units over a range of temperatures from 0 degree C to 35 degree C in 5 degree C intervals. Repeated measurements have been made at each temperature and salinity. Mean values and standard deviations are then computed. The total error budget indicates that the real and imaginary parts of the dielectric constant have a combined standard uncertainty of about 0.3 over the range of salinities and temperatures considered. The measurements are compared with the dielectric constants obtained from the model functions of Klein and Swift and those of Meissner and Wentz. The biggest differences occur at low and high temperatures.

Measurements↗

Quantum-Enhanced Sensing of Axion Dark Matter with a Transmon-Based Single Microwave Photon Counter

We report an axion dark matter search with a haloscope equipped with a microwave photon counter. The haloscope is a tunable high quality factor three-dimensional microwave cavity placed in a magnetic field. The photon counter, operated cyclically, maps an incoming microwave photon onto the state of a superconducting transmon qubit. The measurement protocol continuously monitors the power emitted by the haloscope cavity as well as the dark count background and enables tuning of the cavity frequency to probe different axion masses. With this apparatus, we enhance by a factor of 20 the search speed that can be reached with quantum-limited linear amplifiers and set a new standard for probing the existence of axions with resonant detectors above 5 GHz. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A compact hydrogen maser with exceptional long-term stability

A passive hydrogen maser employing a smaller microwave cavity than previous masers is described. The volume of the entire resonator package, including a conventional source, hexapole state selector, and four magnetic shields, is estimated at 20 liters. The techniques for constructing the ceramic cavity, coating it with FEP, and attaching the endcaps to achieve a stable container (to allow its use as a single vacuum system) are described in detail. Frequency stability measurements were made of four such masers, against an NBS-4 cesium primary standard, against each other, and against eight commercial cesium clocks; frequency stability level is reported as 1.7 x 10 to the -12th tau exp -1/2 from 1 to 100,000 sec, and no drift above 1 x 10 to the -15th/day was found. Pressure and temperature effects on frequency stability were found at the 1 x 10 to the -14th level. Noise behavior beyond 200,000 sec is characterized as random walk. The potential use of a compact stable maser as a clock is suggested.

Howe, D. A.↗