Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency transform”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Synchro-Waveform-Based Event Identification Using Multi-Task Time-Frequency Transform Networks

Influenced by the transient dynamics and reduced inertia characteristics of high-penetration renewable energy systems, power system events frequently exhibit distinct characteristics such as high-frequency components including wide-band oscillations and hyper-harmonics. This makes standard systems face challenges including significant latency and reduced accuracy due to limited data resolution. However, current methods face significant limitations, including insufficient pattern capture ability, low noise immunity, limited feature learning, and restricted localization capabilities, thereby hindering real-time performance. To tackle this issue, this paper proposed a novel synchro-waveform-based event identification approach via a Multi-task Time-frequency Transform Network (MTTNet). Initially, a Time-frequency Transform Block (TTB) is developed to extract both local and global information. The TTB leverages both Fourier and S-transforms to derive comprehensive time-frequency information from synchro-waveforms. Subsequently, a multi-task learning strategy is employed to identify the type and distinguish localization of events. Integrating the TTB and multi-task learning, the MTTNet is designed for synchro-waveform-based event identification, incorporating an adaptive weighting strategy and simplified computation for the S-transform. Two different datasets, comprising simulated and actual synchro-waveforms, are collected from the IEEE 123 bus system and a real-world high-penetration renewable energy system using a universal grid analyzer. Extensive experiments on various conditions are carried out. In conclusion, results demonstrated that the MTTNet consistently surpasses both basic and advanced baselines, with maximum improvements of 13.24% and 9.86%, respectively, while reducing the calculation burden by 15-19 times to achieve real-time event identification.

Event identification↗

Design and Optimization of High-frequency Transformer for Isolated Single-Stage Three-Phase AC/DC Converter using Bidirectional Switches

This paper presents the design and optimization of the high-frequency transformer for an isolated single-stage threephase AC/DC converter enabled by the 4H-SiC BiDirectional Field Effect Transistor (BiDFET). Non-dominated Sorting Genetic Algorithm II (NSGA-II) is used to perform a multiobjective optimization to minimize loss, weight, and volume. A 20 kW, 50 kHz hardware prototype based on the selected optimal point is characterized by a power amplifier. The finite element analysis simulation results are also presented to validate the core magnetic flux density and winding electric field strength. The experimental prototype was tested at 800 Vdc/480 Vrms at 10 kW rated power.

BiDFET, High-frequency transformer, Multiobjective↗

Design and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters

This paper presents a design and optimization methodology for a 200-kW medium-frequency transformer (MFT) based on low-loss magnetic core (FINEMET FT-3TL). The proposed optimal design methodology consists of predesign, preliminary design, and optimal design. In the preliminary design, the parallel-concentric winding structure is selected to increase the current carrying capability and reduce the leakage inductance. Based on the parallel-concentric winding concept, a novel cooing and insulation structure with 3-D printed bobbins are proposed. The optimal designed MFT prototype achieves a power density higher than 19.23 kW/L. The electrical insulation system is tested at 12 kV ac peak voltage. In addition, the partial discharge (PD) test is conducted at 7.5 kV ac peak voltage to ensure the PD-free design. The high-frequency bipolar pulsewidth modulation voltage insulation (PD) test is the first time applied in MFT design and test process. Finally, the transformer is applied in a dual-active-bridge (DAB) converter with 200 kW rated power. The peak efficiency of the DAB converter is 99.53%, and the efficiency at 200 kW is 98.85%. The peak efficiency of MFT is 99.844%, and the efficiency at 200 kW is 99.842%.

42 ENGINEERING↗

Transient MOC with frequency transform and DSA on unstructured mesh

We present an implementation of the transient method of characteristics (MOC) with isotropic time derivatives, accelerated by diffusion synthetic acceleration (DSA). The fully implicit frequency transform method is used to solve the transient problem with analytic precursor integration. The code works on meshes composed of almost any of the commonly used non-curvilinear finite element types, and can handle the deformation of geometry in time-dependent transport calculations. We present results of a continuous Fourier analysis for the transient multigroup DSA problem, and representative benchmarking results are presented for the C5G7-TD benchmark in 2D showing reasonable performance and agreement compared to other codes. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of a Multi-kw, High Frequency Transformer for Space Applications

Various NASA studies have shown that high power (multi-kW and higher) electrical systems for various aerospace applications favor high frequency distribution systems, due to the improved safety and weight factors associated with those systems. Other favorable characteristics include low EMI, minimal wiring and ease of system parameter sensing and control of a single phase system. In aerospace power systems, as in terrestrial AC distribution systems, transformers are needed to provide voltage changes, isolation and the resetting of ground. Under NASA contract NAS3-21948 a multi-kW high frequency transformer was designed, fabricated and tested by Thermal Technology Lab, Inc. of Buffalo, New York. 'The goals of this program included the determination of the relationships between transformer weight, efficiency and operating frequency; low internal temperatures and reduced specific weight; and the validation of these new design concepts through experimentation and the fabrication and testing of transformers and their insulation systems.' The transformer was delivered to NASA-Lewis, where an evaluation program was conducted in Lewis' High Power High Frequency Component Test Facility. The transformer was tested in both atmosphere and under vacuum conditions. This paper will discuss the design of the transformer, the evaluation program and test results, the failures experienced and conclusions.

Roth, Mary Ellen↗

Lightweight, high-frequency transformers

The 25-kVA space transformer was developed under contract by Thermal Technology Laboratory, Buffalo, N. Y. The NASA Lewis transformer technology program attempted to develop the baseline technology. For the 25-kVA transformer the input voltage was chosen as 200 V, the output voltage as 1500 V, the input voltage waveform as square wave, the duty cycle as continuous, the frequency range (within certain constraints) as 10 to 40 kHz, the operating temperatures as 85 deg. and 130 C, the baseplate temperature as 50 C, the equivalent leakage inductance as less than 10 micro-h, the operating environment as space, and the life expectancy as 10 years. Such a transformer can also be used for aircraft, ship and terrestrial applications.

Schwarze, G. E.↗

Detailed Vibration Analysis of Pinion Gear with Time-Frequency Methods

In this paper, the authors show a detailed analysis of the vibration signal from the destructive testing of a spiral bevel gear and pinion pair containing seeded faults. The vibration signal is analyzed in the time domain, frequency domain and with four time-frequency transforms: the Short Time Frequency Transform (STFT), the Wigner-Ville Distribution with the Choi-Williams kernel (WV-CW), the Continuous Wavelet' Transform (CWT) and the Discrete Wavelet Transform (DWT). Vibration data of bevel gear tooth fatigue cracks, under a variety of operating load levels and damage conditions, are analyzed using these methods. A new metric for automatic anomaly detection is developed and can be produced from any systematic numerical representation of the vibration signals. This new metric reveals indications of gear damage with all of the time-frequency transforms, as well as time and frequency representations, on this data set. Analysis with the CWT detects changes in the signal at low torque levels not found with the other transforms. The WV-CW and CWT use considerably more resources than the STFT and the DWT. More testing of the new metric is needed to determine its value for automatic anomaly detection and to develop fault detection methods for the metric.

Mosher, Marianne↗

A High-Frequency Planar Transformer with Medium-Voltage Isolation

This paper presents the design of a low-loss, high-frequency planar transformer having medium-voltage (10’s of kV) isolation capability while transformer primary and secondary windings are interleaved to reduce losses. Medium-voltage isolation between adjacent printed circuit board (PCB) layers is extremely challenging using traditional PCB dielectrics. The isolation requirement is met using PCB with 7 kV/mil polyimide (Panasonic Felios RF775) as the dielectric, and by an appropriate layout of the windings and the inter-winding vias. The transformer is used to implement a dual active bridge (DAB) converter in a stackable dc-ac architecture where the dc port is connected to a photovoltaic (PV) string and ac outputs are connected in series to achieve direct PV string-to-medium voltage conversion without the need for low-voltage collection or a bulky line frequency transformer. Since each DAB transformer processes time-varying power, a design methodology is developed to minimize line-cycle-averaged losses. Experimental results are presented for a 1:1 planar transformer in a 7.5 kW SiC-based dc-to-ac module operating at 200 kHz. Isolation of 26 kV between the primary and secondary layers and between the windings and the core is verified using a hipot tester.

insulation resistance↗

A High-Frequency Planar Transformer with Medium-Voltage Isolation: Preprint

This paper presents the design of a low-loss, high-frequency planar transformer having medium-voltage (10's of kV) isolation capability while transformer primary and secondary windings are interleaved to reduce losses. Medium-voltage isolation between adjacent printed circuit board (PCB) layers is extremely challenging using traditional PCB dielectrics. The isolation requirement is met using PCB with $7$\,kV/mil polyimide (Panasonic Felios RF775) as the dielectric, and by an appropriate layout of the windings and the inter-winding vias. The transformer is used to implement a dual active bridge (DAB) converter in a stackable dc-ac architecture where the dc port is connected to a photovoltaic (PV) string and ac outputs are connected in series to achieve direct PV string-to-medium voltage conversion without the need for low-voltage collection or a bulky line frequency transformer. Since each DAB transformer processes time-varying power, a design methodology is developed to minimize line-cycle-averaged losses. Experimental results are presented for a 1:1 planar transformer in a 7.5\,kW SiC-based dc-to-ac module operating at 200 kHz. Isolation of 26 kV between the primary and secondary layers and between the windings and the core is verified using a hipot tester.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Evaluation of Histone Deacetylase Inhibitors as Radiosensitizers for Proton and Light Ion Radiotherapy

Significant opportunities remain for pharmacologically enhancing the clinical effectiveness of proton and carbon ion-based radiotherapies to achieve both tumor cell radiosensitization and normal tissue radioprotection. We investigated whether pretreatment with the hydroxamate-based histone deacetylase inhibitors (HDACi) SAHA (vorinostat), M344, and PTACH impacts radiation-induced DNA double-strand break (DSB) induction and repair, cell killing, and transformation (acquisition of anchorage-independent growth in soft agar) in human normal and tumor cell lines following gamma ray and light ion irradiation. Treatment of normal NFF28 primary fibroblasts and U2OS osteosarcoma, A549 lung carcinoma, and U87MG glioma cells with 5–10 µM HDACi concentrations 18 h prior to cesium-137 gamma irradiation resulted in radiosensitization measured by clonogenic survival assays and increased levels of colocalized gamma-H2AX/53BP1 foci induction. We similarly tested these HDACi following irradiation with 200 MeV protons, 290 MeV/n carbon ions, and 350 MeV/n oxygen ions delivered in the Bragg plateau region. Unlike uniform gamma ray radiosensitization, effects of HDACi pretreatment were unexpectedly cell type and ion species-dependent with C-12 and O-16 ion irradiations showing enhanced G0/G1-phase fibroblast survival (radioprotection) and in some cases reduced or absent tumor cell radiosensitization. DSB-associated foci levels were similar for proton-irradiated DMSO control and SAHA-treated fibroblast cultures, while lower levels of induced foci were observed in SAHA-pretreated C-12 ion-irradiated fibroblasts. Fibroblast transformation frequencies measured for all radiation types were generally LET-dependent and lowest following proton irradiation; however, both gamma and proton exposures showed hyperlinear transformation induction at low doses (≤25 cGy). HDACi pretreatments led to overall lower transformation frequencies at low doses for all radiation types except O-16 ions but generally led to higher transformation frequencies at higher doses (>50 cGy). The results of these in vitro studies cast doubt on the clinical efficacy of using HDACi as radiosensitizers for light ion-based hadron radiotherapy given the mixed results on their radiosensitization effectiveness and related possibility of increased second cancer induction.

59 BASIC BIOLOGICAL SCIENCES↗

Next-Generation Modular Flexible Low-Cost SiC-based High-Frequency-Link Transformer (Final Technical Report)

This project, led by the small business NextWatt LLC, led to the design and development of a novel high-frequency-link (HFL) transformer that yields reduce number of semiconductor devices compared to conventional solid-state transformers (SSTs). The HFL transformer is based on SiC device technology and nanocrystalline-core-based magnetics techniology. The control actuation of the SiC devices are algorithmically implemented in digital signal processor (DSP) platform. The overall HFL transformer technology is conceived and developed using a modular approach. During the course of the project the novel technology and its experimental performances at the module, multi-phase, and cascaded multi-phase levels have been demonstrated to the sponsor U.S. Department of Energy (DOE).

24 POWER TRANSMISSION AND DISTRIBUTION↗

High voltage-high power components for large space power distribution systems

Space power components including a family of bipolar power switching transistors, fast switching power diodes, heat pipe cooled high frequency transformers and inductors, high frequency conduction cooled transformers, high power-high frequency capacitors, remote power controllers and rotary power transfer devices were developed. Many of these components such as the power switching transistors, power diodes and the high frequency capacitor are commercially available. All the other components were developed to the prototype level. The dc/dc series resonant converters were built to the 25 kW level.

Renz, D. D.↗

High voltage-high power components for large space power distribution systems

Space power components including a family of bipolar power switching transistors, fast switching power diodes, heat pipe cooled high frequency transformers and inductors, high frequency conduction cooled transformers, high power-high frequency capacitors, remote power controllers and rotary power transfer devices were developed. Many of these components such as the power switching transistors, power diodes and the high frequency capacitor are commercially available. All the other components were developed to the prototype level. The dc/dc series resonant converters were built to the 25 kW level.

Renz, D. D.↗