Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency variation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Investigating the Anomalous Frequency Variations Near $T_c$ of Nb SRF Cavities

We report recent studies on the anomalous frequency variations of 1.3 GHz Nb SRF cavities near the transition temperature Tc and use them to investigate the underlying physics of state-of-the-art surface treatments. One such feature, a dip in frequency, correlates directly with the quality factor at 16 MV/m and the anti-Q slope that arise in cavities with dilute concentrations of N interstitial in the RF layer achieved via N-doping and mid temperature baking. For N interstitial, we find that the dip magnitude and Tc follow exponential relationships with the electronic mean free path. We present the first observation of the frequency dip near Tc in a cavity baked at 200 C in-situ for 11 hours, which is concurrent with the anti-Q slope, and may be driven by oxygen diffused from the native oxide, thus suggesting the possibility of ‘‘O-doping.’’ We also investigate the conductivities of two cavities that display different resonant frequency behaviors near Tc and suggest that the anti-Q slope and frequency dip phenomena may occur in the presence of interstitial N or possibly O that inhibit the formation of proximity coupled Nb nano-hydrides.

43 PARTICLE ACCELERATORS↗

Using distributed power electronics-based devices to improve the voltage and frequency stability of distribution systems

Methods include, in response to a line frequency variation of a power grid, adjusting a voltage setpoint of a voltage regulator coupled to the power grid at a grid edge to maintain a voltage at the grid edge, wherein the adjusting the regulated voltage setpoint is configured to reduce the line frequency variation to stabilize the line frequency of the power grid. Apparatus include a voltage regulator configured to couple to a power grid at a grid edge and to maintain a voltage at the grid edge, wherein the voltage regulator is further configured to adjust a voltage setpoint of a voltage regulator in response to a line frequency variation of the power grid to reduce the line frequency variation and stabilize the line frequency of the power grid.

Du, Wei↗

Optimizing Grid Regulation With Gravity Storage Systems: A Comparative Analysis With Different Motor Inertias

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid imbalances in generation and demand is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS scenarios provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 s from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS based on a high-inertia motor may be able to operate over a broader range of frequency variations, whereas a low-inertia system may be limited by thermal constraints of the motor.

frequency regulation↗

Optimizing Grid Regulation With Gravity Storage Systems: A Comparative Analysis With Different Motor Inertias: Preprint

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between the energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid generation-demand imbalances is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS systems provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 seconds from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS with a high-inertia motor may be able operate over a broader range of frequency variations whereas a low-inertia system may be limited by thermal constraints of the motor.

frequency regulation↗

Optimizing Grid Regulation with Gravity Energy Storage Systems: A Comparative Analysis with Different Motor Inertias

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid imbalances in generation and demand is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS scenarios provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 s from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS based on a highinertia motor may be able to operate over a broader range of frequency variations, whereas a low-inertia system may be limited by thermal constraints of the motor.

ENERGY STORAGE,POWER TRANSMISSION AND DISTRIBUTION↗

The Simons Observatory: gain, bandpass and polarization-angle calibration requirements for B-mode searches

We quantify the calibration requirements for systematic uncertainties for next-generation ground-based observatories targeting the large-angle B-mode polarization of the Cosmic Microwave Background, with a focus on the Simons Observatory (SO). We explore uncertainties on gain calibration, bandpass center frequencies, and polarization angles, including the frequency variation of the latter across the bandpass. We find that gain calibration and bandpass center frequencies must be known to percent levels or less to avoid biases on the tensor-to-scalar ratio r on the order of Δ r∼10-3, in line with previous findings. Polarization angles must be calibrated to the level of a few tenths of a degree, while their frequency variation between the edges of the band must be known to O(10) degrees. Given the tightness of these calibration requirements, we explore the level to which residual uncertainties on these systematics would affect the final constraints on r if included in the data model and marginalized over. We find that the additional parameter freedom does not degrade the final constraints on r significantly, broadening the error bar by O(10%) at most. We validate these results by reanalyzing the latest publicly available data from the collaboration within an extended parameter space covering both cosmological, foreground and systematic parameters. Finally, our results are discussed in light of the instrument design and calibration studies carried out within SO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Medium Voltage Testbed for the Performance and Function Tests of a 13.8 kV Power Conditioning System Converter

Medium voltage SiC devices facilitate the development of medium voltage grid-connected power electronics converters. However, it is difficult to test these converters directly on the real medium voltage grid, especially considering abnormal grid conditions, such as grid voltage and frequency variation, and different converter operation modes, such as grid-connected mode and islanded mode. This paper introduces the design and implementation of a medium voltage testbed, which supports tests of medium voltage converters in both grid-connected and islanded mode tests. In the grid-connected mode, the testbed can provide up to 13.8 kV grid voltage, can support the four-quadrant operation, and can emulate different grid conditions, such as voltage and frequency variation. In the islanded mode, the converter under test works as a voltage source and the testbed emulates a three-phase balanced or unbalanced load. Experiment test results are provided to validate the design and capability of the testbed.

Li, Haiguo↗

A Nonstationary and Non-Gaussian Moving Average Model for Solar Irradiance

Historically, power has flowed from large power plants to customers. Increasing penetration of distributed energy resources such as solar power from rooftop photovoltaic has made the distribution network a two-way-street with power being generated at the customer level. The incorporation of renewables introduces additional uncertainty and variability into the power grid. Distribution network operation studies are being adapted to include renewables; however, such studies require high quality solar irradiance data that adequately reflect realistic meteorological variability. Data from satellite-based products are spatially complete, but temporally coarse, whereas solar irradiances exhibit high frequency variation at very fine timescales. We propose a new stochastic method for temporally downscaling global horizontal irradiance (GHI) to 1 min resolution, but we do not consider the spatial aspect due to limited availability of the in situ irradiance measurements. Solar irradiance's first and second-order structures vary diurnally and seasonally, and our model adapts to such nonstationarity. Empirical irradiance data exhibits highly non-Gaussian behavior; we develop a nonstationary and non-Gaussian moving average model that is shown to capture realistic solar variability at multiple timescales. We also propose a new estimation scheme based on Cholesky factors of empirical autocovariance matrices, bypassing difficult and inaccessible likelihood-based approaches. The model is demonstrated for a case study of three locations that are located in diverse climates through the United States. The model is compared against competitors from the literature and is shown to provide better uncertainty and variability quantification on testing data.

Cholesky factor↗

Enhanced Frequency Support Scheme of Generic Inverter-Based Resource Models for Renewable-Dominated Power Grids

The frequency response of SG-dominated power grids is predictable ahead of an occurrence of a frequency event because the frequency response of SGs is consistent, and it can be inferred from the swing equation [1]. However, increasing the portion of IBRs in an SG-dominated power grid might make the characteristics of the conventional power grids no longer valid because this changing resource mix affects grid dynamics and controls [2]. Thus, maintaining these characteristics greatly benefits the control and operation of the power grids with high penetration of IBRs. To maintain these characteristics in IBR-dominated power grids, IBRs should have frequency response capability similar to that of an SG. The WECC modeling validation subcommittee has developed generic IBR models for large system planning [3]-[5]. These models can represent various vendors' dynamic behavior for WTG, PV, and ESS [5]. The current generic IBR models approved by WECC can provide frequency response only from droop control loops in REPC models [6], [7]. The contribution of the loops is proportional to the frequency deviation from the nominal frequency. Thus, it presents an insufficient contribution to arrest frequency variation compared to the frequency response of SGs because it allows a high ROCOF in the early stage of frequency events. This shortfall will become greater as the PL of IBRs increases in power grids. Controller enhancement for the generic IBR models is required to secure the frequency stability under high PL of IBRs as in the SG-dominated power grids. This paper proposes a control extension for the generic IBR models to enhance the frequency support capabilities and discusses the classification of frequency support for the different types of IBR considering their operating constraints. An inertial control scheme is implemented in the REPC and REEC models of the generic IBR models to achieve these objectives. The inertial control scheme includes the following stages: Control area data acquisition, inertia time constant estimation, IBR-related constraint check, IBR contribution determination, and inertial response provision. In the scheme, a REPC acquires control area data from a system operator and estimates a total inertia time constant for the control area the applicable IBR power plant belongs. Then, the estimated inertial time constant is transferred to each IBR controller—REEC—within the power plant. Each REEC checks the availability of applicable IBR for inertial response participation. If the IBR is available, the REEC amplifies the estimated inertial time constant to utilize it for inertial response provision. In this way, the proposed inertial response scheme extends the functionality of the generic IBR models to provide SG-like frequency response within their constraints. Various scenarios considering different IBR types, IBR penetration levels, and frequency control schemes were simulated and compared in an IEEE 39-bus system using PSCAD simulator to verify the effectiveness of the proposed scheme.

Kim, Jinho↗

A Model-Free Frequency Control Approach for Diesel-Wind Powered Microgrids

Islanded microgrids usually consist of diesel generators and renewable energy sources (RES) to reduce the operating cost. Such microgrids have shown values for powering remote locations, but introduced unique challenges for frequency control of the grid due to the variability of renewable energy as well as the decoupled design of converter interface in RES. So, supportive control in RES becomes mandatory in such networks. This paper proposes a new dynamic control strategy, based on model-free control (MFC) approach, to support the primary frequency control of such islanded microgrids. The practical values of MFC have been discussed in various domains due to its control capability without modeling procedure and its efficient computation. In particular, we consider the diesel-wind system and the proposed MFC strategy is utilized as an online controller, which computes supplementary control signals for the rotor-side converter of the available wind turbine generators (WTGs). The calculated input signals allow WTGs to respond to frequency variations and improve the frequency response of the system. The controller is implemented and verified using the modified IEEE 33-bus full nonlinear model of the three-phase diesel-wind system in Simulink. Simulation results show the enhanced frequency response from the MFC strategy.

Park, Byungkwon↗

Multibunch Studies for LCLS-II High Energy Upgrade

The Linac Coherent Light Source (LCLS) X-ray free-electron laser at SLAC is being upgraded to LCLS-II with a superconducting linac and 1 MHz bunch repetition rate. The proposed high-energy upgrade (LCLS-II-HE) will increase the beam energy from 4 to 8 GeV, extending the reach of accessible X-ray photon energies. With the increased repetition rate and longer linac of LCLS-II-HE, multi-bunch effects are of greater concern. We use recently introduced capabilities in the beam transport code ELEGANT to study dipole and monopole beam breakup effects for LCLS-II HE beam parameters. The results indicate that resonant dipole kicks have steady-state settle times on the order of 500 bunches or less and appear manageable. We also consider a statistical variation of the cavity frequencies and transverse offsets of cavities and quadrupoles. Resonant emittance growth driven by monopole kicks is found to be disrupted by frequency variation between cavities.

43 PARTICLE ACCELERATORS↗

Investigation of oscillations above the acoustic cut-off frequency for a sample of Kepler stars. II. Identifying temporal frequency shifts

ABSTRACT Stellar oscillations with frequencies greater than the acoustic cut-off frequency are not trapped within the star’s interior. Geometric interference between these high-frequency waves produces a peak-like structure in the power spectrum of the star, known as the pseudo-modes. In this study, we aim to analyse 51 stars previously identified (from a sample of 91 Kepler stars) to contain statistically significant evidence for pseudo-modes, to determine if the pseudo-mode frequencies vary in time. We obtained these frequency variations and the uncertainty by the resampled periodogram approach, where periodogram realisations were created from successive, overlapping 90-d time segments, and a cross-correlation function was generated between them. The computed shifts were compared against temporal p-mode frequency shifts and a stellar magnetic activity proxy, $S_{\mathrm{ph}}$. We found that for 16 per cent of the stars pseudo-mode frequency shifts were significantly anticorrelated with p-mode shifts, as is the case for the Sun. However, we also found pseudo-mode and p-mode shifts to be significantly correlated in-phase in 8 per cent of our sample. The remainder showed no significant correlation. We also searched for trends between the maximum variation of pseudo-mode frequency shifts and stellar parameters. Whilst we found no correlation between the maximum variation and stellar photospheric and chromospheric proxies, we found frequency variations to have a greater amplitude for cooler and slower rotating stars, which is in opposition to p-mode frequency shift variation. Temporal changes to pseudo-mode frequencies may be attributable to variations in stellar magnetic activity, and therefore can contribute to our understanding of stellar activity cycles.

Millson, L. J. (ORCID:0009000342542676)↗

Genomic variation across Chinook salmon populations reveals effects of a duplication on migration alleles and supports fine scale structure

Abstract The distribution of ecotypic variation in natural populations is influenced by neutral and adaptive evolutionary forces that are challenging to disentangle. This study provides a high‐resolution portrait of genomic variation in Chinook salmon ( Oncorhynchus tshawytscha ) with emphasis on a region of major effect for ecotypic variation in migration timing. With a filtered data set of ~13 million single nucleotide polymorphisms (SNPs) from low‐coverage whole genome resequencing of 53 populations (3566 barcoded individuals), we contrasted patterns of genomic structure within and among major lineages and examined the extent of a selective sweep at a major effect region underlying migration timing (GREB1L/ROCK1). Neutral variation provided support for fine‐scale structure of populations, while allele frequency variation in GREB1L/ROCK1 was highly correlated with mean return timing for early and late migrating populations within each of the lineages ( r 2 = .58–.95; p < .001). However, the extent of selection within the genomic region controlling migration timing was much narrower in one lineage (interior stream‐type) compared to the other two major lineages, which corresponded to the breadth of phenotypic variation in migration timing observed among lineages. Evidence of a duplicated block within GREB1L/ROCK1 may be responsible for reduced recombination in this portion of the genome and contributes to phenotypic variation within and across lineages. Lastly, SNP positions across GREB1L/ROCK1 were assessed for their utility in discriminating migration timing among lineages, and we recommend multiple markers nearest the duplication to provide highest accuracy in conservation applications such as those that aim to protect early migrating Chinook salmon. These results highlight the need to investigate variation throughout the genome and the effects of structural variants on ecologically relevant phenotypic variation in natural species.

Horn, Rebekah L.↗

Structural, magnetic, optical, dielectric and electronic properties of R 2 NiIrO 6 (R = Pr and Nd): A comprehensive experimental and theoretical investigation

Double perovskites are highly promising materials capable of exhibiting a wide variety of phenomena. In this work, we perform a comprehensive experimental and theoretical study of polycrystalline R 2 NiIrO 6 (R = Pr and Nd) compounds. Both compounds were synthesised using the solid-state reaction method. Rietveld refinement confirmed a monoclinic structure with the P2 1 /n space group for both compounds. The scanning electron images showed the average grain sizes of 0.55 μm for R = Pr and 0.46 μm for R = Nd. Fourier transform infrared ra- diation spectra of the two compounds presented two intense bands at 470 cm -1 and 540 cm -1 . The optical measurements revealed that the band gaps of the compounds were in the visible absorption range. The field- cooled magnetisation - field hysteresis measurements indicated exchange bias properties in the synthesised compounds at low temperatures. Both temperature and frequency variation of dielectric constant and loss tangent measurements were conducted. The frequency-dependent ac conductivity measurements indicated that the conductivity increases with the increase of frequency as well as temperature. The Nd 2 NiIrO 6 compound showed lower ac conductivities compared to its isostructural Pr 2 NiIrO 6 compound. The atomic and electronic structures of Nd 2 NiIrO 6 and Pr 2 NiIrO 6 were explored using the spin-polarised calculations performed within the DFT+U method. Our results suggested that the inclusion of on-site correlations and repulsions for the d-states of atoms was necessary in order to obtain finite band gaps of Nd 2 NiIrO 6 and Pr 2 NiIrO 6 systems.

36 MATERIALS SCIENCE↗

Integrated reference cavity with dual-mode optical thermometry for frequency correction

Photonic integrated resonators have advantages over traditional benchtop cavities in terms of size, weight, and cost with the potential to enable applications that require spectrally pure light. However, integrated resonators suffer from temperature-dependent frequency variations and are sensitive to external environmental perturbations, which hinders their usage in precision frequency applications. One solution is to use interrogation of the cavity temperature through dual-mode optical thermometry (DMOT) by measuring the shift of the resonance frequency difference between two polarization or optical frequency modes. Yet this approach has only been demonstrated in bulk-optic whispering gallery mode and fiber resonators. In this paper, we implement dual-mode optical thermometry in an ultra-high Q integrated silicon nitride resonator. A dual-mode resonance frequency difference temperature sensitivity of 188 ± <#comment/> 15 M H z / K is measured. We demonstrate feedforward DMOT frequency correction that, under an applied external temperature ramp, is able to reduce the optical frequency change to 0.31 kHz/s as compared to an uncorrected 10.03 kHz/s, a factor of 30 × <#comment/> reduction. These results show promise for on-chip frequency correction solutions for quantum, metrology, atomic, and coherent optical communications applications.

Zhao, Qiancheng (ORCID:0000000206968667)↗

Parametric Comparative Analysis between Virtual Synchronous Generator and Droop-based Inertia for Inverter-Based Microgrids

This paper presents a parametric comparative analysis between the virtual synchronous generator (VSG) method and the droop control method to emulate inertia in the voltage-source inverter (VSI). Droop controllers are commonly used to regulate sharing power in microgrids and distribute power generation proportionally among VSI’s depending on their rated power. Additionally, VSG has been used to regulate the Rate-of-Change-of-Frequency (RoCoF) of the microgrid using virtual inertia. Although both methods can be used to regulate the frequency variation, the influence of each method on the closed loop eigenvalues is not the same. In this work, the transient response of the frequency is analyzed for each method to determine their advantages and disadvantages regarding frequency regulation in microgrid applications. The results were verified by conducting experimental trials using VSI’s. These experiments demonstrated that VSG is more suitable for regulating RoCoF and frequency nadir than droop controllers since it provides inertial support and improves frequency response.

Campo-Ossa, Daniel D.↗

Bi-Level Linear Programming Model for Automatic Load Shedding: A Distributed Wide-Area Measurement System-based Solution

Load shedding is currently implemented as a two-step based approach. In the first step, manual load shedding is taken place, were system operators, using estimates, inform distribution utilities of predicted stressful conditions. Information provided include the potential use of energy reserves, as well as load shedding amount. In a second step, automatic load shedding is done. The latter is realized using protection relays. While considering frequency variation, pre-defined values of load to be shed and correspondent number of stages for such to be realized are transformed into relay settings. Under-frequency protection relays use only local measurements towards decision making, thus operate in a decentralized architecture. Decision making is done in milliseconds plus breaker time. While this approach has provided much system reliability, considering the new smart grid paradigm, where system dynamics are much faster due to increasing renewable resources penetration, in some operating conditions it will generate sub-optimal solutions, such as islanding. Phasor measurement units provide a source of information which can be useful for this problem. Centralized architecture-based solutions for automatic load shedding, as present in the state-of-the-art, require though total processing times which are not acceptable for real-life implementation. In this work, considering the above, a bi-level linear programming model is presented. The model is implemented considering a distributed architecture while leveraging phasor measurement units data. The upper-level model estimates the current system state. Results of this model are embedded in a lower-level model, which decision variables are the location and load value to be shed. Easy-to-implement model, built-on the classic weighted least squares solution, highlight potential aspects towards real-life applications.

Bretas, Arturo Suman↗

A Frequency Control Method for Islanded Microgrids Using Energy Storage Systems

Islanded microgrids are vulnerable to frequency fluctuations due to the presence of low-inertia distributed energy resources (DERs). Moreover, implementation of both synchronous-based and inverter-based DERs with a significant difference in inertia leads to a power imbalance between generation and consumption during transients. This results in frequency variations which might have severe consequences such as blackouts. This paper develops a control scheme for battery energy storage systems (BESSs) to enhance the dynamic response of islanded microgrids by mitigating the frequency fluctuations. A piecewise linear-elliptic (PLE) droop characteristic is proposed and employed in BESS to achieve a faster power balance between generation and consumption during transients, resulting in enhanced frequency responses. Different case studies are carried out to validate the viability of the proposed approach in improving the dynamics of islanded microgrids.

Pilehvar, Mohsen S.↗