An improved method for simultaneous determination of frictional pressure drop and vapor volume fraction in vertical flow boiling

The two-phase frictional pressure drop and vapor volume fraction in the vertical boiling and adiabatic flow of the refrigerant, R11, have been simultaneously measured by a liquid balancing column and differential magnetic reluctance pressure transducers. An account is given of the experimental apparatus and procedure, data acquisition and analysis, and error estimation employed. All values of two-phase multipliers evaluated on the basis of the measured frictional pressure drop data in vertical upflow fall in the range bounded by the predictions of the Chisholm correlation and the homogeneous model.

Klausner, J. F.↗

SAM Code Validation on Frictional Pressure Drop through Pebble Beds

The System Analysis Module (SAM) is currently under development at Argonne National Laboratory as a modern system-level modeling and simulation tool for safety analyses of advanced non-light water reactors. This report presents a recent effort to validate the capability of SAM to predict the frictional pressure drop through pebble beds. Selected experimental data were used for code validation, including data from test facilities at Texas A&M University, Missouri University of Science and Technology, and North-West University of South Africa. SAM implements three empirical correlations to predict frictional pressure drop: the classical Ergun correlation; the KTA correlation, which is widely used in high-temperature gas-cooled reactor applications; and the Eisfeld and Schnitzlein correlation, which explicitly considers wall effect. Code validation was performed using all three correlations. For all selected experimental data, the KTA correlation shows the best performance and agrees very well with experimental measurement; the Eisfeld and Schnitzlein correlation, explicitly considering wall effects, shows acceptable accuracy, while there is no evidence that it is better than the KTA correlation; the Ergun correlation, however, over-predicts frictional pressure drop for most selected data points.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation and optimization of flow boiling frictional pressure drop correlations using the data from traditional and next-generation refrigerants in a micro-fin tube

This study presents an experimental evaluation and optimization of flow boiling frictional pressure drop correlations for conventional and next-generation refrigerants in a horizontal micro-fin tube, with particular emphasis on the newly emerging refrigerant blends R-454C and R-455A, for which pressure-drop data in enhanced tubes remain limited. Experiments were conducted with R-410A, R-454C, R-455A, R-134a, R-1234yf, and R-1234ze(E) in a copper micro-fin tube with an inner diameter of 8.468 mm, over mass fluxes ranging from 100 to 300 kg/(m²·s) depending on the refrigerant, and evaporation temperatures of 7, 12, and 14 °C. Frictional pressure gradients were determined from measured total pressure drops after subtracting acceleration pressure drop, and the resulting database was used to assess four existing models: Kuo and Wang (1996), Cavallini et al. (1997), Goto et al. (2001), and Diani et al. (2014). The measured frictional pressure gradient increased with vapor quality and mass flux for all refrigerants and increased further at lower evaporation temperatures, with the overall trend strongly related to liquid viscosity. Among the four correlations, the Goto et al. (2001) model provided the best overall agreement with the measured data before optimization. To further improve prediction accuracy, the Kuo and Wang (1996) and Goto et al. (2001) models were optimized using the complete experimental database. After optimization, both models reduced the overall mean absolute deviation to below 15%, while the optimized Goto et al. (2001) model maintained the best and most consistent overall performance. The results provide new pressure-drop data for next-generation refrigerants and demonstrate that parameter optimization can significantly enhance the applicability of existing micro-fin-tube correlations.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

ANN-based correlation for frictional pressure drop of non-azeotropic mixtures during cryogenic forced boiling

A crucial aspect of Joule-Thomson cryocooler analysis and optimization is the accurate estimation of frictional pressure drop. This paper presents a pressure drop model for boiling of non-azeotropic mixtures of nitrogen with hydrocarbons (e.g., methane, ethane, and propane) in microchannels. These refrigerant mixtures are important for their applicability in natural gas liquefaction plants. Here, the pressure drop model is based on computational intelligence techniques, and its performance is evaluated with the mean relative error (mre), and compared with three correlations previously selected as most accurate: Awad and Muzychka; Sun and Mishima; and Cicchitti et al.

42 ENGINEERING↗

Improvement of Wall Drag Modeling Capabilities of CTF

Coolant Boiling in Rod Arrays-Two Fluid (COBRA-TF), or CTF, is a nuclear thermal hydraulic subchannel code used throughout academia and industry. It solves discretized forms of nine coupled equations for the mass, momentum, and energy equations for the liquid and vapor fields; the mass and momentum equation for the droplet field; and the energy equation for solid structures. This work focuses on improving the wall drag modeling capabilities of CTF by adding new friction models that account for surface roughness. Prior to this work, CTF used simple correlations that assumed that surfaces were smooth. In reality, different materials in the reactor have varying degrees of roughness that act to increase drag and frictional pressure drop. The frictional pressure drop is important, as it partly defines the driving head necessary for achieving certain flow conditions. This is particularly important in passively cooled systems that rely on natural circulation. Therefore, the effects of surface roughness cannot be neglected, as it affects flow rate and distribution, heat transfer and turbulence. (authors)

42 ENGINEERING↗

Condensation pressure drop of HFC-134a and R-404A in a smooth and micro-fin U-tube

The frictional pressure drop during condensation of HFC-134a and R-404A in a smooth (8.56 mm ID) and micro-fin U-tubes (8.96 mm ID) are experimentally investigated. Different from previous studies, the present experiments are performed for various condensing temperatures. The test runs are done at average saturated condensing temperatures ranging from 35 C to 60 C. The mass fluxes are between 90 and 800 kg/m{sup 2}s. The experimental results indicate that the average frictional pressure drop increases with mass flux but decreases with increasing condensing temperature for both smooth and micro-fin-tubes. The average frictional pressure drops of HFC-134a and R-404A for the micro-fin-tubes were 1-1.7 and 1-2.1 times larger than that in smooth tube respectively. New correlations based on the data gathered during the experimentation for predicting frictional pressure drop are proposed for wide range of operating conditions. (author)

42 ENGINEERING↗

Effect of flow topology on the calculation of two-phase frictional multipliers in uniformly heated flow of R-134a in a rectangular duct

The two-phase frictional multipliers for SUVA R-134a flowing in a rectangular duct (with D{sub H} = 4.8 mm) have been measured for three nominal system pressures (0.88, 1.34 and 2.34 MPa) and four nominal mass fluxes (510, 1020 and 1740, 2040 kg/m{sup 2}/s) under uniform heat flux conditions. The data is compared with adiabatic data previously taken at similar flow conditions, as well as with several classical multiplier correlations. The comparisons reveal a strong effect of pressure and mass flux on the flow topology and, by extension, a large effect on the calculation of acceleration and frictional pressure drop components. For this fluid and this geometry, entrainment and fluid separation is enhanced at higher pressures and mass flux such that most of the liquid exists in the test section edges and as dispersed droplets in the core. For these cases, the classical simplified approach to calculate acceleration pressure drop fails to adequately predict the acceleration component and leads to erroneous calculations of frictional pressure drop from the measured total pressure drop. Best estimates of the true acceleration component are given, based on void profiles measured with a gamma densitometer system, comparisons to the adiabatic data, and recasting the data in terms of the total pressure drop multiplier as a function of the Martinelli parameter, X{sub tt}. (author)

42 ENGINEERING↗

Fixed Packed Bed Reactors in Reduced Gravity

We present experimental data on flow pattern transitions, pressure drop and flow characteristics for cocurrent gas-liquid flow through packed columns in microgravity. The flow pattern transition data indicates that the pulse flow regime exists over a wider range of gas and liquid flow rates under microgravity conditions compared to 1-g and the widely used Talmor map in 1-g is not applicable for predicting the transition boundaries. A new transition criterion between bubble and pulse flow in microgravity is proposed and tested using the data. Since there is no static head in microgravity, the pressure drop measured is the true frictional pressure drop. The pressure drop data, which has much smaller scatter than most reported 1-g data clearly shows that capillary effects can enhance the pressure drop (especially in the bubble flow regime) as much as 200% compared to that predicted by the single phase Ergun equation. The pressure drop data are correlated in terms of a two-phase friction factor and its dependence on the gas and liquid Reynolds numbers and the Suratman number. The influence of gravity on the pulse amplitude and frequency is also discussed and compared to that under normal gravity conditions. Experimental work is planned to determine the gas-liquid mass transfer coefficients. Because of enhanced interfacial effects, we expect the gas-liquid transfer coefficients k(L)a and k(G)a (where a is the gas-liquid interfacial area) to be higher in microgravity than in normal gravity at the same flow conditions. This will be verified by gas absorption experiments, with and without reaction in the liquid phase, using oxygen, carbon dioxide, water and dilute aqueous amine solutions. The liquid-solid mass transfer coefficient will also be determined in the bubble as well as the pulse flow regimes using solid benzoic acid particles in the packing and measuring their rate of dissolution. The mass transfer coefficients in microgravity will be compared to those in normal gravity cocurrent flow to determine the mass transfer enhancement and propose new mass transfer correlations for two-phase gas-liquid flows through packed beds in microgravity.

Motil, Brian J.↗

Fixed Packed Bed Reactors in Reduced Gravity

We present experimental data on flow pattern transitions, pressure drop and flow characteristics for cocurrent gas-liquid flow through packed columns in microgravity. The flow pattern transition data indicates that the pulse flow regime exists over a wider range of gas and liquid flow rates under microgravity conditions compared to 1-g and the widely used Talmor map in 1-g is not applicable for predicting the transition boundaries. A new transition criterion between bubble and pulse flow in microgravity is proposed and tested using the data. Since there is no static head in microgravity, the pressure drop measured is the true frictional pressure drop. The pressure drop data, which has much smaller scatter than most reported 1-g data clearly shows that capillary effects can enhance the pressure drop (especially in the bubble flow regime) as much as 200% compared to that predicted by the single phase Ergun equation. The pressure drop data are correlated in terms of a two-phase friction factor and its dependence on the gas and liquid Reynolds numbers and the Suratman number. The influence of gravity on the pulse amplitude and frequency is also discussed and compared to that under normal gravity conditions. Experimental work is planned to determine the gas-liquid and liquid-solid mass transfer coefficients. Because of enhanced interfacial effects, we expect the gas-liquid transfer coefficients kLa and kGa (where a is the gas-liquid interfacial area) to be higher in microgravity than in normal gravity at the same flow conditions. This will be verified by gas absorption experiments, with and without reaction in the liquid phase, using oxygen, carbon dioxide, water and dilute aqueous amine solutions. The liquid-solid mass transfer coefficient will also be determined in the bubble as well as the pulse flow regimes using solid benzoic acid particles in the packing and measuring their rate of dissolution. The mass transfer coefficients in microgravity will be compared to those in normal gravity cocurrent flow to determine the mass transfer enhancement and propose new mass transfer correlations for two-phase gas-liquid flows through packed beds in microgravity.

Motil, Brian J.↗

Two-phase flow characteristics in multiple orifice valves

This work presents an experimental investigation on the characteristics of two-phase flow through multiple orifice valve (MOV), including frictional pressure drop and void fraction. Experiments were carried out using an MOV with three different sets of discs with throat thickness-diameter ratios (s/d) of 1.41, 1.66 and 2.21. Tests were run with air and water flow rates ranging between 1.0 and 3.0 m{sup 3}/h, respectively. The two-phase flow patterns established for the experiment were bubbly and slug. Two-phase frictional multipliers, frictional pressure drop and void fraction were analyzed. The determined two-phase multipliers were compared against existing correlations for gas-liquid flows. None of the correlations tested proved capable of predicting the experimental results. The large discrepancy between predicted and measured values points at the role played by valve throat geometry and thickness-diameter ratio in the hydrodynamics of two-phase flow through MOVs. A modification to the constants in the two-phase multiplier equation used for pipe flow fitted the experimental data. A comparison between computed frictional pressure drop, calculated with the modified two-phase multiplier equation and measured pressure drop yielded better agreement, with less than 20% error. (author)

42 ENGINEERING↗

Taylor flow in intermediate diameter channels: Simulation and hydrodynamic models

The two-phase Taylor flow pattern has been studied extensively. However, limited information is available for flows in intermediate diameter channels (5 ≲ Bo ≲ 40, or 6mm ≲ D ≲ 27mm for ambient gas–water flows), as found in air-lift and bubble pumps. Previous investigations have primarily evaluated Taylor flow models in terms of overall pressure drop, which incorporates hydrostatic and multiple hydrodynamic components. Thus, individual sub-models and sources of error could not be directly assessed. Here in this investigation, volume-of-fluid (VOF) based Taylor flow simulations are performed over a wide range of laminar and turbulent conditions in the intermediate Bond number regime (5 < Bo < 20, 250 < N f < 1000, and 20 < Re j < 8100). Results are applied to individually evaluate hydrodynamic sub-models for bubble-region frictional pressure drop gradient (∇p f,b ), slug frictional pressure drop gradient (∇p f,s ), and flow transition pressure loss (Δp trans ). Based on these results, recommendations are provided for selection of hydrodynamic sub-models. These hydrodynamic closure models are integrated with kinematic flow models to yield a complete intermediate Bond number Taylor flow formulation for which all submodels were independently validated. The resulting model achieves improved accuracy for predicting experimental liquid flow rates compared with previous Taylor flow models (81% of cases within 50% of measured flows rates).

42 ENGINEERING↗

Convective heat transfer in a high aspect ratio minichannel heated on one side

Experimental results are presented for single-phase heat transfer in a narrow rectangular minichannel heated on one side. The aspect ratio and gap thickness of the test channel were 29:1 and 1.96 mm, respectively. Friction pressure drop and Nusselt numbers are reported for the transition and fully turbulent flow regimes, with Prandtl numbers ranging from 2.2 to 5.4. Turbulent friction pressure drop for the high aspect ratio channel is well-correlated by the Blasius solution when a modified Reynolds number, based upon a laminar equivalent diameter, is utilized. The critical Reynolds number for the channel falls between 3500 and 4000, with Nusselt numbers in the transition regime being reasonably predicted by Gnielinski's correlation. The dependence of the heat transfer coefficient on the Prandtl number is larger than that predicted by circular tube correlations, and is likely a result of the asymmetric heating. The problem of asymmetric heating condition is approached theoretically using a boundary layer analysis with a two-region wall layer model, similar to that originally proposed by Prandtl. The analysis clarifies the influence of asymmetric heating on the Nusselt number and correctly predicts the experimentally observed trend with Prandtl number. Furthermore, a semi-analytic correlation is derived from the analysis that accounts for the effect of aspect ratio and asymmetric heating, and is shown to predict the experimental results of this study with a mean absolute error (MAE) of less than 5% for 4000 < Re < 70,000.

42 ENGINEERING↗

Experimental Investigation of Oscillatory Flow Pressure and Pressure Drop Through Complex Geometries

A series of experiments have been performed to investigate the oscillatory flow pressure and pressure drop through complex geometries. These experiments were conducted at the CSU-SLRE facility which is a horizontally opposed, two-piston, single-acting engine with a split crankshaft driving mechanism. Flow through a rectangular duct, with no insert (obstruction), was studied first. Then four different inserts were examined: Abrupt, Manifold, Diverging Short and Diverging Long. The inserts were mounted in the center of the rectangular duct to represent different type of geometries that could be encountered in Stirling machines. The pressure and pressure drop of the oscillating flow was studied for: 1) different inserts, 2) different phase angle between the two pistons of the engine (zero, 90 lead, 180, and 90 lag), and 3) for different piston frequencies (5, 10, 15, and 20 Hz). It was found that the pressure drop of the oscillatory flow increases with increasing Reynolds number. The pressure drop was shown to be mainly due to the gas inertia for the case of oscillatory flow through a rectangular duct with no insert. On the other hand, for the cases with different inserts into the rectangular duct, the pressure drop has three sources: inertia, friction, and local losses. The friction pressure drop is only a small fraction of the total pressure drop. It was also shown that the dimensionless pressure drop decreases with increasing kinetic Reynolds number.

Ibrahim, Mounir B.↗

Heat transfer and fluid dynamics of air-water two-phase flow in micro-channels

Heat transfer, pressure drop, and void fraction were simultaneously measured for upward heated air-water non-boiling two-phase flow in 0.51 mm ID tube to investigate thermo-hydro dynamic characteristics of two-phase flow in micro-channels. At low liquid superficial velocity j{sub l} frictional pressure drop agreed with Mishima-Hibiki's correlation, whereas agreed with Chisholm-Laird's correlation at relatively high j{sub l}. Void fraction was lower than the homogeneous model and conventional empirical correlations. To interpret the decrease of void fraction with decrease of tube diameter, a relation among the void fraction, pressure gradient and tube diameter was derived. Heat transfer coefficient fairly agreed with the data for 1.03 and 2.01 mm ID tubes when j{sub l} was relatively high. But it became lower than that for larger diameter tubes when j{sub l} was low. Analogy between heat transfer and frictional pressure drop was proved to hold roughly for the two-phase flow in micro-channel. But satisfactory relation was not obtained under the condition of low liquid superficial velocity. (author)

42 ENGINEERING↗

Pressure drop in fully developed, turbulent, liquid-vapor annular flows in zero gravity

The prediction of frictional pressure drop in fully developed, turbulent, annular liquid-vapor flows in zero gravity using simulation experiments conducted on earth is described. The scheme extends the authors' earlier work on dispersed flows. The simulation experiments used two immiscible liquids of identical density, namely, water and n-butyl benzoate. Because of the lack of rigorous analytical models for turbulent, annular flows, the proposed scheme resorts to existing semiempirical correlations. Results based on two different correlations are presented and compared. Others may be used. It was shown that, for both dispersed and annular flow regimes, the predicted frictional pressure gradients in 0-g are lower than those in 1-g under otherwise identical conditions. The physical basis for this finding is given.