Search NASA⌕ Search

SEARCH · Search NASA

Results for “full width at half maximum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Raman signatures from age-dating PuO 2 since last calcination

The self-irradiation of PuO 2 has been shown to affect the attributes of fifteen vibrational bands in the Raman spectrum. The vibrational bands correspond to the Raman allowed vibrational mode T 2g , overtones, defects, and bands from electronic origin. Defects in the crystal lattice from low-calcination temperature and alpha decay origins are responsible for the changes in the band attributes (band position, full-width half maximum (FWHM), intensity). Crystal lattice defects are also responsible for the growth of the defect bands. The temporal behavior of the vibrational bands can be used to estimate the age of the material since last calcination. Laser annealing was used to reset the material to full crystallinity prior to the aging study. 240 PuO 2 , with an alpha decay rate of 3.67 greater than the decay rate of 239 PuO 2 , was primarily used to assess the alpha decay-induced damage within 3 years. The aging study focused on the time-dependent properties of the T 2g band and the growth of defect bands. The FWHM of the T 2g band and the ratio of the areas of the defect bands/T 2g band were measured through a time period in excess of 3 years. The data from this study were found very close to the data describing the temporal evolution of the lattice constant measured with the X-ray diffraction (XRD) technique. The local physical properties of the material measured with Raman spectroscopy and the lattice parameter constant measured with XRD indicates a strong correlation between the two techniques. Although both techniques provide similar age-dating information, in contrast to the few milligram quantities required for XRD, Raman spectroscopy requires a 10 µm diameter PuO 2 particle to provide an estimate of the material age since last calcination.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Off-line commissioning of the St. Benedict radiofrequency quadrupole cooler-buncher

The St. Benedict ion trapping system, which aims to measure the β - v angular correlation parameter in superallowed-mixed mirror transitions, is under construction at the University of Notre Dame. These measurements will provide much-needed data to improve the accuracy of the V ud element of the CKM matrix. One of the major components of this system is the radio frequency quadrupole cooler-buncher, which is necessary to create low-emittance ion bunches for injection into the measurement Paul trap. The off-line commissioning of the cooler-buncher, using a potassium ion source, determined that the device could produce cooled ion bunches characterized by a 50-ns full-width-half-maximum time width at its exit. The commissioning results also determined the trapping efficiency to be 93(1)% and the trapping half-life to be 20.0(5) s.

Paul trap↗

New Lightning-Derived Vertical Total Electron Content Data Provide Unique Global Ionospheric Measurements

A newly released, novel ionospheric data set of global gridded vertical total electron content (VTEC) is introduced in this paper. This VTEC data set, provided by Los Alamos National Laboratory (LANL), is derived from very high frequency (VHF; defined as 30–300 MHz) broadband radio-frequency (RF) measurements of lightning made by U.S. Department of Defense sensing systems on board Global Positioning System (GPS) satellites. This paper presents the new data set (LANL VTEC), discusses the errors inherent in VHF TEC estimation due to ionospheric dispersion, and compares the LANL VTEC to two community standard VTEC gridded products: Jet Propulsion Laboratory's Global Ionospheric Model (JPL GIM) and the CEDAR community's Open Madrigal VTEC gridded measurements of L-band GNSS (global navigation satellite systems) TEC. We find that the LANL VTEC data have an offset of 3 TECU from CEDAR Madrigal GNSS VTEC and a full-width-half-maximum (FWHM) of 6 TECU. In comparison, the offset between LANL VTEC and the JPL GIM model is –3 TECU, but with a FWHM of 5 TECU. We also compare to Jason-3 VTEC measurements over the ocean, finding an offset of less than 0.5 TECU and an FWHM of <5 TECU. Because this technique uses a completely different methodology to determine TEC, the sources of errors are distinct from the typical ground-based GNSS L-band (GHz) TEC measurements. Also, because it is derived from RF lightning signals, this data set provides measurements in regions that are not well covered by ground-based GPS measurements, such as over oceans and over central Africa.

79 ASTRONOMY AND ASTROPHYSICS↗

On-chip spectrometers using stratified waveguide filters

We present an ultra-compact single-shot spectrometer on silicon platform for sparse spectrum reconstruction. It consists of 32 stratified waveguide filters (SWFs) with diverse transmission spectra for sampling the unknown spectrum of the input signal and a specially designed ultra-compact structure for splitting the incident signal into those 32 filters with low power imbalance. Each SWF has a footprint less than 1 µm × 30,µm, while the 1 × 32 splitter and 32 filters in total occupy an area of about 35 µm × 260 µm, which to the best of our knowledge, is the smallest footprint spectrometer realized on silicon photonic platform. Experimental characteristics of the fabricated spectrometer demonstrate a broad operating bandwidth of 180 nm centered at 1550 nm and narrowband peaks with 0.45 nm Full-Width-Half-Maximum (FWHM) can be clearly resolved. This concept can also be implemented using other material platforms for operation in optical spectral bands of interest for various applications.

42 ENGINEERING↗

High-resolution optical micro-spectroscopy extending from the near-infrared to the vacuum-ultraviolet

Optical characterization of small samples over a wide spectral range with rapid data acquisition is essential for the analysis of many material systems, such as 2D van der Waals layers and their heterostructures. In this paper, we present the design and implementation of a tabletop micro-spectroscopy system covering the near-infrared to the vacuum-ultraviolet (1.2 eV–6.8 eV or ~1.0 μm to 185 nm) using mostly off-the-shelf components. It can measure highly reproducible local reflectance spectra with a total integration time of a few minutes and a full-width-half-maximum spot size of 2.7 by 5.6 μm. For precise positioning, the design also allows simultaneous monitoring of the measurement location and the wide-field image of the sample. We demonstrate ultra-broadband reflectance spectra of exfoliated thin flakes of several wide-gap 2D materials, including ZnPS 3 , hexagonal BN, and Ca(OH) 2 .

47 OTHER INSTRUMENTATION↗

Spatiotemporal evolution of emission and absorption signatures in a laser-produced plasma

Here we report spatiotemporal evolution of emission and absorption signatures of Al species in a nanosecond (ns) laser-produced plasma (LPP). The plasmas were generated from an Inconel target, which contained ~0:4 wt. % Al, using 1064 nm, ≈6 ns full width half maximum pulses from an Nd:YAG laser at an Ar cover gas pressure of ≈34 Torr. The temporal distributions of the Al I (394.4 nm) transition were collected from various spatial points within the plasma employing time-of-flight (TOF) emission and laser absorption spectroscopy, and they provide kinetics of the excited state and ground state population of the selected transition. The emission and absorption signatures showed multiple peaks in their temporal profiles, although they appeared at different spatial locations and times after the plasma onset. The absorption temporal profiles showed an early time signature representing shock wave propagation into the ambient gas. We also used emission and absorption spectral features for measuring various physical properties of the plasma. The absorption spectral profiles are utilized for measuring linewidths, column density, and kinetic temperature, while emission spectra were used to measure excitation temperature. A comparison between excitation and kinetic temperature was made at various spatial points in the plasma. Our results highlight that the TOF measurements provide a resourceful tool for showing the spatiotemporal LPP dynamics with higher spatial and temporal resolution than is possible with spectral measurements but are difficult to interpret without additional information on excitation temperatures and linewidths. The combination of absorption and emission TOF and spectral measurements thus provides a more complete picture of LPP spatiotemporal dynamics than is possible using any one technique alone.

(140.3440) Laser-induced breakdown, (280.4788) Opt↗

Time-of-flight vs time-of-arrival in neutron spectroscopic measurements for high energy density plasmas

The neutron time-of-flight (nToF) diagnostic technique has a lengthy history in Inertial Confinement Fusion (ICF) and High Energy Density (HED) Science experiments. Its initial utility resulted from the simple relationship between the full width half maximum of the fusion peak signal in a distant detector and the burn averaged conditions of an ideal plasma producing the flux [Lehner and Pohl, Z. Phys. 207, 83–104 (1967)]. More recent precision measurements [Gatu-Johnson et al., Phys. Rev. E 94(8), 021202 (2016)] and theoretical studies [Munro, Nucl. Fusion 56, 035001 (2016)] have shown the spectrum to be more subtle and complicated, driving the desire for an absolute calibration of the spectrum to disambiguate plasma dynamics from the conditions producing thermonuclear reactions. In experiments where the neutron production history is not well measured, but the neutron signal is preceded by a concomitant flux of photons, the spectrum can be in situ calibrated using a set of collinear detectors to obtain a true “time-of-flight” measurement. This article presents the motivation and overview of this technique along with estimates of the experimental precision needed to make useful measurements in existing and future nToF systems such as the pulsed power Z-machine located in Albuquerque, NM, at Sandia National Laboratories.

Fusion experiments↗

Comparison of laser-produced plasma spatio-temporal electron density evolution measured using interferometry with simulation results

Due to the difficulties associated with experimental measurements of laser-produced plasma (LPP) properties during the earliest stages of plasma evolution, radiation hydrodynamic codes are often used. However, although these codes have been extensively validated in the higher intensity regimes, validation at low to moderate intensities has been limited. In this study, the spatio-temporal electron density evolution in an LPP generated at moderate laser intensities and at various laser wavelengths was validated against the FLASH code for times up to 20 ns. The LPP was generated by focusing the fundamental and various harmonics radiation (1064, 532, and 266 nm) from a 6 ns full width half maximum Nd:YAG laser, at a laser intensity of 10 GW cm -2 , onto a copper target. The spatio-temporal density evolution of the expanding plasma was analyzed using Nomarski interferometry. Experimental measurements were found to be consistent with FLASH simulations, and the dependence of electron densities on wavelength was found to be in agreement with analytical models, varying as n e ∝ λ -0.7 . However, slight differences were noted in the widths and shape functions of the experimental and simulated electron density profiles.

2D fast imaging↗

Experimental investigation of H-mode pedestal turbulence using a charge exchange imaging diagnostic system at DIII-D

Microtearing modes (MTMs) (ω ~ ω de k θ ρ s ~ 0.1, k r ρ s ~ 0.3 – 1.0) are predicted to cause substantial electron thermal transport in the H-mode pedestal, limiting fusion performance on high-power devices. Localized 2D measurements of low-to-intermediate wavenumber density fluctuations in the edge of DIII-D H-mode plasmas suggest the presence of temporally intermittent or ‘bursting’ MTMs during the inter-ELM cycle in the steep gradient region. These measurements are obtained using a new intermediate radial resolution multichannel Charge eXchange Imaging (CXI) diagnostic that analyzes the intensity of the CVI emission at 529 nm. The mode is peaked near ρ = 0.97 with a radial full-width half maximum of 1.5–2.0 cm and a normalized density fluctuation amplitude peak of $\frac{dn_C}{n_C}$ ~ 5%, peaking near 60 kHz in the lab frame. The mode additionally features a broad spectral width from 30 to 180 kHz and propagates in the electron diamagnetic direction in the plasma frame. CXI measurements taken during discharges with high density and current ramps provide evidence that MTMs become unstable at finite collisionality and remain at nearly the same location in ρ-space despite scanning of rational surface position. This indicates that the location of the peak in the electron diamagnetic frequency is a stronger driving force than individual rational surfaces.

DIII-D↗

Development of a large array of Silicon Drift Detectors for high-rate synchrotron fluorescence spectroscopy

An array of small-area Silicon Drift Detectors (SDD), named Hera, has been developed at Brookhaven National Laboratory (BNL) in the past few years. Its primary application is high-rate spectroscopy at synchrotrons. Each SDD pixel is a 1 mm × 1 mm square to match the footprint of the original diode-based pixel detector called Maia, which was developed for the same application. The replacement of the diode with an SDD allows for better energy resolution at short shaping times and an increased stability of the detector. 32, 96, and 384-channel arrays were designed and fabricated and achieved a Full Width Half Maximum (FWHM) as low as 176 eV at 5.9 keV with peaking time of 1 μs at -13°C. The sensor design, simulation, fabrication, its readout system, and its spectroscopic performance are reported.

47 OTHER INSTRUMENTATION↗

Photoinduced structural recovery dynamics of rare-earth nickelate thin films

Photoinduced structural dynamics of rare-earth nickelate thin films, NdNiO 3 and SmNiO 3 , grown on (001) oriented SrTiO 3 were studied using time-resolved x-ray diffraction. The evolution of the (002) Bragg peak was tracked following laser excitation. The recovery pathways were found to be strongly dependent on laser fluence for NdNiO 3 and distinct for the two rare-earth nickelates. The recovery of the (002) peak shifts was modeled using a one-dimensional thermal diffusion model which showed that the recovery processes are non-thermal at high fluences. For NdNiO 3 , the timescales for the recovery of the (002) peak shift were found to be closely related to Ni magnetism recovery, potentially indicating magneto-structural coupling. Moreover, the evolution of integrated intensity and full-width-half-maximum points towards the presence of a structural phase separation during recovery. In conclusion, our studies highlight structural recovery pathways in nickelates by comparing the distinct responses of the photoinduced metal-insulator transition in NdNiO 3 and SmNiO 3 .

36 MATERIALS SCIENCE↗

ASCENT: a balloon-borne hard x-ray imaging spectroscopy telescope using transition edge sensor microcalorimeter detectors

Core collapse supernovae are thought to be one of the main sources in the galaxy of elements heavier than iron. Understanding the origin of the elements is thus tightly linked to our understanding of the explosion mechanism of supernovae and supernova nucleosynthesis. X-ray and gamma-ray observations of young supernova remnants, combined with improved theoretical modeling, have resulted in enormous improvements in our knowledge of these events. Here, the isotope Ti44 is one of the most sensitive probes of the innermost regions of the core collapse engine, and its spatial and velocity distribution are key observables. Hard x-ray imaging spectroscopy with the Nuclear Spectroscopic Telescope Array (NuSTAR) has provided new insights into the structure of the supernova remnant Cassiopeia A (Cas A), establishing the convective nature of the supernova engine. However, many questions about the details of this engine remain. We present here the concept for a balloon-borne follow-up mission called A SuperConducting ENergetic x-ray Telescope (ASCENT). ASCENT uses transition edge sensor gamma-ray microcalorimeter detectors with a demonstrated 55-eV full-width half maximum energy resolution at 97 keV. This 8- to 16-fold improvement in energy resolution over NuSTAR will allow for high-resolution imaging and spectroscopy of the Ti44 emission. This will allow for a detailed reconstruction of gamma-ray line redshifts, widths, and shapes, allowing us to address questions such as, What is the source of the neutron star kicks? What is the dominant production pathway for Ti44? Is the engine of Cas A unique?

79 ASTRONOMY AND ASTROPHYSICS↗

Improved noise performance from the next-generation buried-channel p-MOSFET SiSeROs

The Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. In our earlier work, we characterized a number of first prototype SiSeROs with the MOSFET transistor channels at the surface layer. An equivalent noise charge (ENC) of around 15 electrons root mean square (RMS) was obtained. In this work, we examine the first buried-channel SiSeRO. Here we have achieved substantially improved noise performance of around 4.5 electrons root mean square (RMS) and a full width half maximum (FWHM) energy resolution of 132 eV at 5.9 keV, for a readout speed of 625 kpixel/s. We also discuss how digital filtering techniques can be used to further improve the SiSeRO noise performance. Additional measurements and device simulations will be essential to further mature the SiSeRO technology. This new device class presents an exciting new technology for the next-generation astronomical X-ray telescopes requiring fast, low-noise, radiation-hard megapixel imagers with moderate spectroscopic resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Line Emission Mapper: an X-ray probe mission concept to study the cosmic ecosystems and the physics of galaxy formation

In the 2020 Astrophysics Decadal Survey, the National Academies identified cosmic feedback and structure formation as a key question that should drive research in the upcoming decade. In response to this recommendation, NASA released a call for X-ray and IR probe-class missions, with a $\$$1B cost cap. The line emission mapper (LEM) is a mission concept designed in response to this call. LEM is a single-instrument X-ray telescope that consists of a Wolter–Schwarzschild type I X-ray optic with a 4 m focal length, coupled with an X-ray microcalorimeter with a 30' field of view (FoV), 15" angular resolution, and 2.5 eV energy resolution [full-width half maximum (FWHM)], with a 1.3 eV FWHM energy resolution central subarray. The high throughput X-ray mirror combined with the large FoV and excellent energy resolution allows for efficient mapping of extended emission-line dominated astrophysical objects from megaparsecs to sub-pc scales to study cosmic ecosystems and unveil the physical drivers of galaxy formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photonic ring resonator notch filters for astronomical OH line suppression

Photonic ring resonator arrays used as notch filters are a promising novel solution to improve the signal-to-noise ratio of ground-based astronomical observations by suppressing OH emission lines in the near-infrared (NIR) wavelength range (0.9-2.5 μm). We aim to fabricate a series of ring resonators connected by a waveguide, each with its resonance wavelength and full-width-half-maximum (FWHM) matched with one of the OH emission lines. The fundamental structure of ring resonator-based notch filters is a ring resonator evanescently coupled to a waveguide. Due to the optical loss of the ring resonator, the transmission of light through the waveguide will be suppressed at the resonance wavelength of the ring resonator. The degree of suppression can be controlled by varying the coupling strength between the waveguide and the ring resonator, while the resonance wavelength can be controlled by the geometry and size of the ring. However, since a single ring resonator has multiple modes each with a different wavelength separated by its free spectral range (FSR), the additional suppression at other wavelengths may undermine the signal. Therefore, the ideal FSR off the ring resonators needs to be larger than the measurement window. For this application, we aim the FSR to be 1 larger than 30 nm . Our initial measurement results revealed two major challenges for this application. First, the FSR of the ring resonators is limited by the bending loss of ring resonators. In a standard 220 nm silicon-on-insulator material platform, the FSR of ring resonators cannot exceed 30 nm; Second, due to the wafer thickness variation and fabrication inaccuracy, the achievable accuracy in the resonance wavelength of a fabricated single ring resonator is only ~1.5 nm. In this work, we report our novel solutions to the above two challenges. For the first one, we have developed a novel structure based on the Vernier effect to greatly raise the FSR of ring resonators. Serially coupled Vernier ring structures is a typical approach to increase the FSR without encountering bending loss, but it requires restrictive matching of the coupling and optical loss of the rings and any imperfect matching can result in even noisier signals. On the contrary, our structure, as shown in shown in Fig. 1, does not require the restrictive matching. The signals of two output ports in our structure marked in Fig. 1 will be added together to form the final output signal, and Fig. 2 shows the finite-difference time-domain (FDTD) simulation results of the final output signal. As can be seen, the FSR of the entire structure is well-beyond 60 nm with little noise at other wavelengths. For the second one, we have developed an easy-to-implement method to permanently tune the resonance wavelengths of ring resonators within 0.1 nm accuracy. The tuning mechanism is based on the property of hydrogen silsesquioxane (HSQ) resist. As a negative tone electron beam resist, HSQ upon exposure will cross-link and eventually form SiO2. The refractive 2 index of HSQ resist and formed SiO2 are slightly different , enabling the tuning. By having a thin layer of HSQ resist on top of ring resonator structures followed by SiO2 cladding, the resonance wavelengths of ring resonators can be post-tuned Advances in Optical Astronomical Instrumentation 2019, edited by Simon Ellis, Céline d'Orgeville, Downloaded From: https://www.spiedigitallibrary.org/conference-proceedings-of-spie on 23 Sep 2020 Terms of Use: https://www.spiedigitallibrary.org/terms-of-use through electron beam exposure. We have found that, within 5 nm tuning range, the resonance wavelength shift and dosage applied obeys a linear relationship. So a simple calibration beforehand can result in resonance wavelength tuning within 0.1 nm accuracy. The transmission spectra of a 3-ring device before and after tuning is shown in Fig. 3.

Astronomical optics↗

Metal-semiconductor-metal structured p-i-n GaN/AlGaN ultrafast detectors for deep-UV photodetection

We report the productive outcome of the design, fabrication, and testing of a new class of GaN/AlGaN-based ultrafast, sensitive photodiodes for deep-UV solar blind photodetection. Pt was employed as the interdigitated metal electrode to establish that while a Schottky contact was formed at the metal/semiconductor heterojunction, it was the quantum wells in the p-i-n vertical structure that produced the diode characteristics of the detectors. The metal–semiconductor–metal design retained its ultrafast property as expected in the p-i-n structure because the spacing between the interdigitated fingers was asymmetrically implemented to optimize the photogenerated carriers’ transit time from the quantum well to the external circuitry. Also, the vertical p-i-n structure provided its renowned efficient photocarrier generation, which was significantly enhanced by the delta quantum well architecture of the vertical epitaxial structure. The active area of the device was 300 μm × 300 μm with 5-μm finger width, and asymmetric electrode spacing of 2 μm, 3 μm, and 5 μm. Here, the best device had peak responsivity of 3.5 A/W under 262-nm illumination with full width half maximum of 337.2-ps and 37.5-ps rise times when biased with 20 V.

efficient↗

Characterization of Partial Charge Collection Induced by Neutron Damage in High-Purity Germanium Detectors

This paper investigates the correlation of damage induced by neutron interactions and degradation in the spectra of HPGe detectors. As neutrons kinetically interact with germanium crystals, they create interstitial and vacancy defects within the lattice. These defects then interfere with the charge migration of electron-hole pairs and reduce resolution in the observed energy spectrum. The partial charge collection produces observable spectral changes by increasing the peak width and reducing resolution (full width half maximum). A detailed characterization using various check sources was performed before and after iterations of neutron exposure in order to observe the effects of the neutron damage. An additional set of measurements was performed along with characterizations to show the detector’s response at discrete locations on the HPGe crystal. This was done to observe how the spectrum changes when the gamma rays are isolated to regions of various thicknesses of germanium. In order to impart damage, the detector was placed inside a californium shuffler with the face of the detector against the guide tube for the 252 Cf source. For irradiation of the HPGe, the source was then positioned in front of the face of the detector using the stepper motor of the shuffler. The neutron exposure time intervals were recorded and increased based on the initial damage observed. An MCNP simulation was performed to estimate the amount of interactions that occurred in the germanium crystal to ensure enough damage had occurred. Studying the effects that neutron damage imparts on a bullet-type HPGe detector can help provide necessary data to estimate total neutron exposure limits, reduce the likelihood of decisions made on suspect data, and aid in diagnostics of a damaged detector.

36 MATERIALS SCIENCE↗

A summary of air sampler filter performance data: Bladewerx Speclon 5(TM) and Millipore FMLW047 5um

Bladewerx™ LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon 5™ PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon™ filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. Millipore FMLW (5μm) filters are also used at Los Alamos, and a comparison of the two filter types has been requested. For filter face air velocities from 0.066 m/s to 1.5 m/s, the aerosol collection efficiency (for 0.3 μm particle diameters) and the filter pressure drops were measured. The FWHM (full width half maximum) of alpha spectroscopy peaks was also determined, using naturally occurring radon progeny at an alpha energy of 6 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗