Graphene Oxide Functionalized Biosensor for Detection of Stress-Related Biomarkers
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Thermal emittance of nickel as function of oxide thickness measured, using filament in vacuum technique and microphotography
Thermal emittance of nickel as function of oxide thickness measured, using filament in vacuum technique and microphotography
The startup reliability of a 15 cm diameter mercury bombardment ion thruster which employs a pulsed high voltage tickler electrode on the main and neutralizer cathodes is examined. Startup of the thruster is achieved 100% of the time on the main cathode and 98.7% of the time on the neutralizer cathode over a 3640 cycle test. The thruster was started from a 20 C initial condition and operated for an hour at a 600 mA beam current. An energy efficiency of 75% and a propellant utilization efficiency of 77% was achieved over the complete cycle. The effect of a single cusp magnetic field thruster length on its performance is discussed. Guidelines are formulated for the shaping of magnetic field lines in thrusters. A model describing double ion production in mercury discharges is presented. The production route is shown to occur through the single ionic ground state. Photographs of the interior of an operating-hollow cathode are presented. A cathode spot is shown to be present if the cathode is free of low work-function surfaces. The spot is observed if a low work-function oxide coating is applied to the cathode insert. Results show that low work-function oxide coatings tend to migrate during thruster operation.
Thermal emittance of Cu measured in vacuum in spherical enclosure by calorimetric method to investigate oxidation effect
Seebeck effect and electrical conductivity of stannic oxide as function of temperature and ambient pressure
Porous silica sol-gel glasses into which reactive vanadium oxide functional groups incorporated exhibit number of unique characteristics. Because they bind molecules of some species both reversibly and selectively, useful as chemical sensors or indicators or as scrubbers to remove toxic or hazardous contaminants. Materials also oxidize methane gas photochemically: suggests they're useful as catalysts for conversion of methane to alcohol and for oxidation of hydrocarbons in general. By incorporating various amounts of other metals into silica sol-gel glasses, possible to synthesize new materials with broad range of new characteristics.
Levitation experiments on the International Space Station (ISS) are ongoing. The European Space Agency (ESA) Materials Science Laboratory Electromagnetic Levitator (MSL-EML) has been in operation since 2015. US investigators are on several of the European Topical Teams and have been heavily involved with the experiments since 2009. The experiments include magneto-hydrodynamic (MHD) modeling of macro-convection, the effects of convection on microstructure, investigation of metallic glass formation, and much more. Recently NASA selected four proposals to the MaterialsLab NASA Research Announcement (NRA) for experiments on the Japan Aerospace eXploration Agency (JAXA) Electrostatic Levitation Furnace (ELF), which was launched to the ISS in 2015. It is estimated that the four US investigators will have flight experiments on ELF within the next few years. The experiments range from a novel method to measure interfacial tension to investigations of thermophysical properties of metals, metal oxides, and non-linear optical materials. Using the MSL-EML and ELF, US investigators are studying a wide range of NASA exploration-relevant materials. Levitation experiments enable exploration in many ways. For example, high quality thermophysical properties of high-temperature materials are critical to develop accurate models of casting, welding, and metal additive manufacturing, which could lead to more efficient and more reliable production of metallic parts for exploration, commercial, and industrial applications. High-quality thermophysical properties could also lead to the development of functional oxide glass and optical materials. In many cases, the accuracy of available property data is the limiting factor in the predictive capabilities of the models. Many thermophysical properties can be measured in a levitator on Earth, but with convective contamination. This contamination plays a significant role in the formation of the intermediate phases. In particular, nucleation and viscosity measurements demand quiescent conditions that can only be attained in microgravity-based levitation systems. A brief overview of the ongoing and planned levitation experiments on the ISS will be presented, followed by the exploration-relevance.
Mass spectra of quinoline and isoquinoline N- oxides, discussing diagnostic values of fragmentation reactions for heteroaromatic N- oxide function presence
Surface studies have been performed on aluminum polycrystalline surfaces which have been mechanically scraped. Such studies were initiated in order to understand surface effects occurring in tribological processes which involve rubbing surfaces and the effects of adsorption of oxygen. To characterize the surfaces, the following three different experimental approaches have been used: (1) X.P.S. (X-ray photoelectron spectroscopy), in order to check the cleanliness of the surfaces and follow the adsorption and oxidation kinetics; (2) Analysis of the work function changes by following the energy spectra of secondary electrons emitted under low energy electron bombardment; and (3) Analysis of photoemission intensities under U.V. excitation. The reference state being chosen to be the surface cleaned by ion bombardment and exposures to oxygen atmospheres have been shown to lower the work function of clean polycrystalline aluminum by 1.2 eV. The oxygen pressure is found to affect only the kinetics of these experiments. Mechanical scraping has been shown to induce a decrease ( 0.3 eV) in the work function, which could sharply modify the kinetics of adsorption on the surface.
Neutrophil functions (phagocytosis, oxidative burst, degranulation) and expression of surface markers involved in these functions were studied in 25 astronauts before and after 4 space shuttle missions. Space flight duration ranged from 5 to 11 days. Blood specimens were obtained 10 days before launch (preflight or L-10), immediately after landing (landing or R+0), and again at 3 days after landing (postflight or R+3). Blood samples were also collected from 9 healthy low-stressed subjects at 3 time points simulating a 10-day shuttle mission. The number of neutrophils increased at landing by 85 percent when compared to the preflight numbers. Neutrophil functions were studied in whole blood using flow cytometric methods. Phagocytosis of E.coli-FITC and oxidative burst capacity of the neutrophils following the 9 to 11 day missions were lower at all three sampling points than the mean values for control subjects. Phagocytosis and oxidative burst capacity of the astronauts was decreased even 10-days before space flight. Mission duration appears to be a factor in phagocytic and oxidative functions. In contrast, following the short-duration (5-days) mission, these functions were unchanged from control values. No consistent changes in degranulation were observed following either short or medium length space missions. The expression of CD16, CD32, CD11a, CD11b, CD11c, L-selectin and CD36 was measured and found to be variable. Specifically, CD16 and CD32 did not correlate with the changes in oxidative burst and phagocytosis. We can conclude from this study that the stresses associated with space flight can alter the important functions of neutrophils.
The electrical conductivity of (Mg, Fe)O magnesiowustite containing 9 and 27.5 mol pct FeO has been measured at simultaneously high pressures (30-32 GPa) and temperatures using a diamond anvil cell heated with a continuous wave Nd:YAG laser and an external resistance heater. The conductivity depends strongly on the FeO concentration at both ambient and high pressures. At the pressures and temperatures of about 30 GPa and 2000 K, conditions expected in the lower mantle, the magnesiowustite containing 27.5 percent FeO is 3 orders of magnitude more conductive than that containing 9 percent FeO. The activation energy of magnesiowustite decreases with increasing iron concentration from 0.38 (+ or - 0.09) eV at 9 percent FeO to 0.29 (+ or - 0.05) eV at 27.5 percent FeO.
Spaceflight factors, such as microgravity and space radiation, are known to put astronauts at risk for negative effects to their tissue regeneration and degenerative conditions. On our previous spaceflight research, we found that long duration spaceflight produced increased oxidative stress and activation of the inflammatory response as a major contributor to physiological changes, including alterations to the cardiovascular and musculoskeletal systems, metabolism, and the liver. Proliferation, apoptosis, and ion-channel remodeling of vascular smooth muscle cells, as well as endothelial inflammation, and nitric oxide synthase-nitric oxide system regulation have been shown by spaceflight and simulated spaceflight projects. CDKN1ap21 is a regulatory gene for tissue regeneration and also plays an important role in upregulating oxidative stress caused by radiation. In further research, we have also determined CDKN1ap21 to be overexpressed during spaceflight. When knocked out in mice, however, it protects against unloading-induced changes to the morphology and physiology of carotid arteries. In this proposal, we seek to test a potential dietary countermeasure to down-regulate CDKN1ap21 in the mice and protect against oxidative stress in the rodents. Specifically, we will expose both Wildtype and CDKN1ap21-null mice to hydrogen peroxide to induce oxidative stress and observe the molecular mechanisms in which a dietary supplement protects vascular smooth muscle cells against the consequences of the apoptotic environment within Wildtype mice versus the, hypothetically, sound physiology of CDKN1ap21-null mice. The successful completion of this experiment will conclusively determine accuracy of a dietary supplement as a CDKN1ap21 suppressor. This will provide a new perspective on the problem of increased oxidative stress developing into cardiovascular disease as a result of long-term space flight. This research will address the Human Research Plan Roadmaps Risk of Cardiac Rhythm Problems including CV-8, the Risk of Cardiovascular Disease and Other Degenerative Tissue Effects from Radiation Exposure including Degen-6 and Degen-7, and the Risk of Adverse Health Event from Radiation Exposure including IM-8. Additionally, this research will address Space Biology Research Plans questions SBP CMB-1, SBP CMB-3, and SB AN-2.
The fabrication and thermo-mechanical properties of SiC monofilament- and SiC fiber tow-reinforced reaction-bonded silicon nitride matrix composites (SiC/RBSN) and fully dense SiC monofilament-reinforced silicon nitride matrix composites (SiC/Si3N4) have been reviewed. The SiC/RBSN composites display high strength and toughness, and low thermal conductivity in the as-fabricated condition, but are susceptible to internal oxidation and mechanical property degradation in the intermediate temperature range from 400 to 1100 C. The internal oxidation problem can be avoided by applying functionally graded oxidation resistant coatings on external surfaces of the composite. On the other hand, the fully dense SiC/SiC3N4 composites fabricated by using SiC monofilaments and pressure assisted sintering methods display moderate strength and limited strain capability beyond matrix cracking stress. Advantages, disadvantages, and potential applications of SiC fiber-reinforced silicon nitride matrix composites fabricated using various fiber types and processing methods are discussed.
Explore the source record for details and available documents.
In 2009 and 2010, Concepts NREC prepared for and performed a series of tests on a 52% scale of a version of the Pratt & Whitney Rocketdyne J-2X Oxidizer Turbopump under a Phase III SBIR with NASA MSFC. The test article was a combined inducer and impeller, tested as a unit. This paper presents an overview of the test rig and facility, instrumentation, signal conditioning, data acquisition systems, testing approach, measurement developments, and lessons learned. Results from these tests were presented in the form of two papers at the previous JANNAF joint propulsion conference, in December of 2011.
Broad tissue degeneration and the failure of normal tissue regenerative processes in microgravity because of mechanical unloading are increasing concerns for sustaining life in space as the duration of future flight missions increases. Work in our laboratory has identified normal adult stem cell-based tissue regenerative processes, such as the formation of new bone, cartilage, and immune cells, as being particularly sensitive to the stresses of mechanical unloading in microgravity. Our studies have also identified the inhibition of differentiation of marrow mesenchymal stem cells and activation of CDKN1ap21-mediated cell cycle arrest in proliferative osteoprecursor cells on the bone surface as potential mechanisms for spaceflight-induced skeletal changes. This finding, in combination with the role of CDKN1ap21 as a suppressor of mammalian tissue regeneration, suggests that this gene could be responsible for suppressing stem cell-based tissue regeneration in response to disuse. In this work, we hypothesized that CDKN1ap21 regulates regenerative bone formation in response to alterations in mechanical load and tested this hypothesis by studying the skeletal phenotype and stem cell regenerative ability of juvenile (4-11 weeks old) and adult (18 weeks-12 months old) p21 (--) knockout (KO) mice. Additionally, we analyzed bone micro-architectural properties, bone formation rates and differentiation capacity of bone marrow stem cells (BMSCs) from male and female KO mice exposed to hindlimb unloading (HU) for 15-30 days. We found that juvenile KO mice exhibited increased femoral trabecular and cortical bone formation, whilst three-point bending of the tibias from KO mice showed decreased bone stiffness. Conversely, adult KO mice exhibited no significant differences in micro-architectural properties compared to WT (wild-type) but woven bone structure was indicative of rapid bone remodeling. Furthermore, cortical bone properties showed similar characteristics to aged bone, including increased cross-sectional area and perimeter, whilst three-point bending showed increased stiffness and toughness. Interestingly, in-vitro, KO mice exhibited increased differentiation and mineralized nodule formation in osteoblastogenesis assays compared to WT. Preliminary results from CDKN1ap21 KO mice subjected to HU suggest altered sensitivity to mechanical unloading resulting in decreased cortical thickness compared to WT mice. However, KO mice subjected to short and long-duration HU show increased in-vitro differentiation potential of BMSCs to from form mature, mineral-forming osteoblasts, indicating maintenance of regenerative potential. Analysis of bone formation rates, cell proliferation rates and key genes of interest are currently underway. These results indicate a novel role for CDKN1ap21 in load-dependent osteoprogenitor proliferation and differentiation and that deletion of CDKN1ap21 results in an age-dependent release of osteoblast proliferation inhibition and increased bone formation and turnover.
Explore the source record for details and available documents.