Search NASASearch

SEARCH · Search NASA

Results for “gamma detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A flow-through gamma detection system for sub-surface radioxenon tracer measurements in LYNM PE1

A continuous flow-through, real-time radioxenon sensor array has been designed to monitor either 127 Xe or 133 Xe tracer gas as part of a series of underground chemical explosions in the Low-Yield Nuclear Monitoring (LYNM) Physics Experiment 1 (PE1). The sensors are pairs of shielded thallium-doped sodium iodide gamma-ray detectors that surround a gas measurement chamber. Each measurement chamber is connected to a sampling location in the geology surrounding the chemical explosion or in the access tunnel. The first experiment in the series, PE1 A, occurred in 2023 and the system quantified the 127 Xe tracer gas in the gas sampling lines for four weeks following the experiment execution. The array generated a set of radioxenon concentration time series with a 15-minute resolution that will be used to refine subsurface gas transport models.

Gamma-ray coincidence detection

Prototype X-ray and Gamma Detection with Cyclotron Radiation Emission Spectroscopy

Cyclotron radiation emission spectroscopy, or CRES, is a novel approach to measuring the energy of an electron. By trapping a free electron in a high magnetic field, it undergoes cyclotron motion and emits radiofrequency (RF) waves. The frequency of this RF radiation is directly related to the energy of the electron. Because many cycles of the RF emission are recorded, the energy resolution of the CRES system is on the order of a single electron volt. To make a CRES system sensitive to photons, a target gas is used to induce a photoelectric effect, producing the electron that is subsequently trapped. By adding the binding energy of the target atom, the energy of the incident photon may be reconstructed. Using a xenon target gas, photoelectric interactions dominate up to approximately 300 keV, covering not only all atomic shell X-rays of the elements, but many low-lying nuclear states as well, including key transuranic elements related to nuclear security. CRES holds the potential of maintaining single-eV resolution up to this 300-keV range, thereby surpassing current state-of-the-art detectors by a factor of 10-100. The instrumental resolution of the system is limited by the uniformity of the applied magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Gamma Ray Detection In Liquid Argon Time Projection Chambers

Gamma rays are photons in excess of 100 keV of energy and can be produced by a variety of mechanisms like radioactive decay and inelastic neutrino-argon interactions. A reconstruc- tion of Compton scattering gamma rays was developed for use in liquid argon time projection chambers. This reconstruction was tested with detectors developed to demonstrate the ca- pabilities of Deep Underground Neutrino Experiment (DUNE) Near Detector Liquid Argon target (ND LAr). In October 2024, a radioactive fluorine-18 source was placed next to the Full Scale Demonstrator. The data obtained was used to test this reconstruction algorithm. It was able to determine the direction of the photons with an error of less than 10 percent. In addition to this work, there has been significant work on designing a liquid argon based Positron Emission Tomography (PET) scanner. PET scanners detect gamma rays emitted by a tracer chemical to help screen for diseases like cancer. In addition to the applications to medical imaging, this thesis briefly explores the applications of this reconstruction to de-excitation photons produced in interactions between neutrinos and argon nuclei. These applications could improve studies focusing on neutrinos originating from accelerators and supernovae.

Murphy, Thomas [Syracuse U.]

Growth of High-Purity CsPbBr 3 Crystals for Enhanced Gamma-Ray Detection

High-quality CsPbBr 3 crystals hold significant potential for gamma-ray detection due to their remarkable optoelectronic properties. This study details an optimized production process using the Bridgman method to achieve highly pure CsPbBr 3 crystals. By implementing rigorous synthesis and purification techniques, we successfully reduced the total impurity levels to 9 ppm, as confirmed by glow discharge mass spectroscopy (GDMS). The resulting CsPbBr 3 crystals demonstrate exceptional performance, including high transparency, intense photoemission, and prolonged photoluminescence decay times. These properties facilitate superior gamma-ray detection with an energy resolution of 1.4% for the 137 Cs 662 keV gamma-rays, comparable to commercial Cd 1-x Zn x Te (CZT) detectors. Our findings underscore the critical relationship between material purity and detector performance, highlighting the potential of CsPbBr 3 as a cost-effective alternative in radiation detection applications. Further studies on defect origins and electronic states are necessary to fully leverage the capabilities of CsPbBr 3 crystals in practical high-energy radiation detection systems.

Bridgman

Surface Trap Dynamics and Gamma‐Ray Detection Enhancement in Passivated FAPbBr 3 Perovskite Crystals

Perovskite‐based direct radiation detectors offer a compelling platform for room‐temperature gamma spectroscopy due to their high sensitivity, tunable optoelectronic properties, and compatibility with solution processing. While prior studies on formamidinium lead tribromide (FAPbBr 3 ) have shown that surface passivation mitigates deep trap state impact on the charge collection efficiency (CCE), the influence of surface‐based shallow traps on time‐resolved detector response remains largely unexplored. In this article, a digital signal processing (DSP) method is applied to analyze waveform rising edge dynamics in FAPbBr 3 single‐crystal detectors, identifying prompt and delayed charge collection components. Using the second derivative of the collected charge signal, the onset of shallow trap reemission is isolated, occurring 1.1 µs after carrier generation. Surface passivation suppressed deep trap states, shifting carrier occupancy toward shallower traps and extending the temporal window of delayed charge collection. This delayed contribution correlates with measurable changes in the temporal and amplitude distributions of detector events. By leveraging time‐domain filtering informed by these dynamics, a selective enhancement in signal quality and gamma peak‐to‐Compton ratio (PCR) is achieved, while preserving over 90% of photoelectric events. An improvement in the PCR to 1.80, from the original 1.09, is enabled by focusing on high collection efficiency events corresponding to reemitted carriers in the 1.1 to 3 µs range after the generation event. These results demonstrate a pathway for leveraging shallow trap dynamics to enhance spectral fidelity in time‐resolved perovskite detectors.

36 MATERIALS SCIENCE

Determination of electron-hole pair creation energy in Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 quaternary semiconductor for room-temperature gamma-ray detection

We report the first-time measurement of the electron-hole pair (ehp) creation energy (W ehp ) in novel Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 (CZTS) quaternary semiconductor. CZTS in single crystalline form is poised to be the future of large-volume room-temperature gamma-ray detectors due to its excellent compositional homogeneity with highly reduced defects, high-Z (atomic number) constituents, wide bandgap (1.6 eV), and superior charge transport properties. Despite a great deal of study of the material and device properties since its inception, the W ehp in CZTS has not been measured experimentally. Accurate determination of W ehp is essential for calibration of the spectrometer and other theoretical calculations. In this study we have used an absolute calibration approach, which is based on an iterative approach that yields the Wehp as the best-fit parameter. Using a 241 Am alpha emitting radioisotope and a planar CZTS detector, the Wehp in CZTS was calculated to be 4.47 eV. The obtained value has been validated by accurately predicting the peak energy for gamma rays emitted by a 137 Cs source and read by a CZTS detector with different dimensions. The dependences of the calculated W ehp value on the detector dimensions, type of interaction, and effect of charge trapping are also discussed.

42 ENGINEERING

Multilabel proportion prediction and out-of-distribution detection on gamma spectra of short-lived fission products

In the machine learning problem of multilabel classification, the objective is to determine for each test instance which classes the instance belongs to. In this work, we consider an extension of multilabel classification, called multilabel proportion prediction, in the context of radioisotope identification (RIID) using gamma spectra data. We aim to not only predict radioisotope proportions, but also identify out-of-distribution (OOD) spectra. We achieve this goal by viewing gamma spectra as discrete probability distributions, and based on this perspective, we develop a custom semi-supervised loss function that combines a traditional supervised loss with an unsupervised reconstruction error function. Our approach was motivated by its application to the analysis of short-lived fission products from spent nuclear fuel. In particular, we demonstrate that a neural network model trained with our loss function can successfully predict the relative proportions of 37 radioisotopes simultaneously. The model trained with synthetic data was then applied to measurements taken by Pacific Northwest National Laboratory (PNNL) to conduct analysis typically done by subject-matter experts. Here, we also extend our approach to successfully identify when measurements are OOD, and thus should not be trusted, whether due to the presence of a novel source or novel proportions.

Anomaly detection

A Systematic Search for MeV–GeV Pulsar Wind Nebulae without Gamma-Ray Detected Pulsars

An increasing number of pulsar wind nebulae (PWNe) are being identified in the TeV band by ground-based Imaging Air Cherenkov Telescopes such that they constitute the dominant source class of Galactic TeV emitters. However, MeV–GeV PWN counterparts are still largely lacking. To date, only a dozen PWNe are identified by the Fermi–Large Area Telescope (LAT) in the MeV–GeV band. Most PWNe are located along the Galactic plane embedded within the prominent, diffuse Galactic γ-ray emission, which makes these sources difficult to disentangle from the bright diffuse background. We present a systematic search for γ-ray counterparts to known PWNe in the 300 MeV–2 TeV energy band using the Fermi–LAT. We target the locations of previously identified PWNe that lack detected Fermi–LAT pulsars to minimize associated pulsar contamination. The sample includes six previously identified Fermi PWNe and eight Fermi–LAT sources associated with PWNe. We report the analysis of 58 regions of interest and classify Fermi–LAT detected sources as either a likely PWN or a candidate PWN counterpart based on their morphological and spectral characteristics across the broadband spectrum. There are nine unidentified Fermi–LAT sources that we consider as likely PWN counterparts, which, if confirmed to be PWNe, would greatly increase the PWN population detected by the Fermi–LAT from 12 to 21. The remaining Fermi–LAT detected sources are considered weaker PWN candidates. A second approach in the systematic search for γ-ray emitting PWNe will involve studying the off-pulse phases of Fermi–LAT detected pulsars for the presence of an obscured PWN and will be reported in a subsequent paper.

Acharyya, A. [Univ. of Southern Denmark, Odense (D

System and method for neutron and gamma radiation detection using non-homogeneous material scintillator

The present disclosure relates to a method for detecting incoming radiation having a plurality of differing properties including at least one of differing types, differing energies or differing incoming directions. The method involves using a scintillator structure formed from first and second dissimilar scintillator materials, where the first and second dissimilar scintillator materials emit first and second different colors of light in response to the incoming radiation. A first light detector is used for detecting light having the first color, and a second light detector is used for detecting light having the second color. A first output signal is generated in response to the detection of light having the first color, and a second output signal is generated in response to detecting light having the second color. The first and second output signals are then analyzed to determine at least one property of the incoming radiation.

Brodsky, Jason Philip

Characterization of Scintillating Crystal for High Energy Radiation Detection and Applications

Cesium Hafnium Chloride (Cs2Hfl6) is a promising metal halide scintillating detector due to its excellent characteristics such as non-hygroscopicity, high light yield without doping. Scintillators plays an important role in nuclear security applications as detectors at border monitoring stations. We grew and characterized CHC crystals to be fabricated for gamma detection. Photoluminescence was performed using the Duetta Fluorescence and Absorbance Spectrometer. The energy response to Cs-137 and Co-60 reference sources was recorded for a representative sodium iodide (NaI) scintillating detector.

Reeder, Angel

Constructing a High‐Resolution Aftershock Catalog for the 2017 Mw 8.2 Tehuantepec Earthquake Sequence Using a Machine Learning–Based Workflow

The 8 September 2017 Mw 8.2 Tehuantepec earthquake was the largest instrumentally recorded normal‐faulting earthquake in Mexico. The mainshock occurred offshore within the Tehuantepec seismic gap, generating >30,000 aftershocks in the following year. We applied an open‐source, machine learning (ML)–assisted workflow to construct a high‐resolution aftershock catalog using data from temporary and permanent seismic networks in southern Mexico. The workflow integrates PhaseNet for phase detection; GaMMA for phase association; and VELEST, HypoInverse, and HypoDD for velocity modeling and relocation. We processed seven months of continuous waveform data from 29 broadband stations, including a temporary rapid‐response deployment that improved station coverage of the offshore rupture zone. To evaluate performance, we compared our results against analyst‐reviewed picks and event locations from the Servicio Sismológico Nacional catalog. The resulting catalog contains 11,374 relocated earthquakes and represents the most comprehensive published dataset for this sequence, incorporating the first full use of the temporary network. Relocated hypocenters show improved depth control and align well with the Slab2.0 subduction geometry, revealing clearer separation between offshore slab events and onshore crustal seismicity. This study demonstrates that combining ML‐based detection with established methods provides a scalable and reproducible approach for constructing high‐quality earthquake catalogs in tectonically complex environments and offers practical guidance for adapting similar workflows to other earthquake sequences.

Garcia, Marc [The University of Texas at El Paso,

First Time-Resolved Leader Spectra Associated With a Downward Terrestrial Gamma-Ray Flash Detected at the Telescope Array Surface Detector

Optical emissions associated with Terrestrial Gamma ray Flashes (TGFs) have recently become important subjects in space-based and ground-based observations as they can help us understand how TGFs are produced during thunderstorms. In this paper, we present the first time-resolved leader spectra of the optical component associated with a downward TGF. The TGF was observed by the Telescope Array Surface Detector (TASD) simultaneously with other lightning detectors, including a Lightning Mapping Array (LMA), an INTerFerometer (INTF), a Fast Antenna (FA), and a spectroscopic system. The spectroscopic system recorded leader spectra at 29,900 frames per second (33.44 μs time resolution), covering a spectral range from 400 to 900 nm, with 2.1 nm per pixel. The recordings of the leader spectra began 11.7 ms before the -18 kA return stroke and at a height of 2.37 km above the ground. These spectra reveal that optical emissions of singly ionized nitrogen and oxygen occur between 167 μs before and 267 μs after the TGF detection, while optical emissions of neutrals (H I, 656 nm; N I, 744 nm, and O I, 777 nm) occur right at the moment of the detection. The time-dependent spectra reveal differences in the optical emissions of lightning leaders with and without downward TGFs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Expected Gamma-Ray Burst Detection Rates and Redshift Distributions for the BlackCAT CubeSat Mission

We report the results of an extensive set of simulations exploring the sensitivity of the BlackCAT CubeSat to long-duration gamma-ray bursts (GRBs). BlackCAT is a NASA APRA-funded CubeSat mission for the detection and real-time subarcminute localization of high-redshift (z ≳ 3.5) GRBs. Thanks to their luminous and long-lived afterglow emissions, GRBs are uniquely valuable probes of high-redshift star-forming galaxies and the intergalactic medium. In addition, each detected GRB with a known redshift serves to localize a region of high-redshift star formation in three dimensions, enabling deep follow-on searches for host galaxies and associated local and large-scale structures. We explore two distinct models for the GRB redshift distribution and luminosity function, both consistent with Swift observations. We find that, for either model, BlackCAT is expected to detect a mean of 42 bursts per year on orbit, with 6.7% to 10% of these at z > 3.5. BlackCAT bursts will be localized to an r 90 ≲ 55'' precision and reported to the community within seconds. Due to the mission orbit and pointing scheme, bursts will be located in the night sky and well placed for deep multiwavelength follow-up observations. BlackCAT is on schedule to achieve launch readiness in 2025.

79 ASTRONOMY AND ASTROPHYSICS

Boron-10 Doped Polysiloxanes as Matrix Materials for Application in the Simultaneous Detection and Discrimination of Gamma Rays and Fast and Thermal Neutrons

Three boron-10 enriched aromatic molecules have been synthesized and incorporated into two different commercial polysiloxane resins, Shin Etsu KER-6000 and Wacker SilRes H62-C. Scintillating fluorophores, 9,9-dimethyl-2-phenylfluorene (PhF) and 2,5-diphenyloxazole (PPO), were tested in combination with each resin and boron-10 molecule for the simultaneous detection of gamma rays, fast neutrons, and thermal neutrons. Here, the H62-C resin was able to solubilize a large amount of PhF, in excess of 20 wt%. Cure kinetics were controlled through the addition of divinylbenzene and phenyl tris(dimethylsiloxy)silane cross-linker solution to the H62-C resin, with rheology experiments demonstrating a large reduction in time to gelation when 20 wt% cross-linker solution was added, from more than 4 hours to less than 1 hour. These polysiloxane resins can be cured in 3 hours under air, while common poly(vinyltoluene) scintillators require at least 4 days of heating and oxygen-free conditions. PhF-doped KER-6000 with tolyl boronate pinacol ester exhibited the best overall performance with a light yield of 62% relative to EJ-200 and thermal neutron capture at energies up to 103 keVee (84 keVee for EJ254B-5). Additionally, four samples exhibited light yields surpassing an industry-standard boron-doped plastic scintillator, Eljen’s EJ254B-5. Over the course of ten months, the KER-6000 samples showed precipitation of dopant molecules, which reduced their light yield by 15% on average, while H62-C proved to be more stable with only a 6% reduction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Reassessment of PHDS Fulcrum40h High Purity Germanium (HPGe) Detector System Performance

This report presents a comprehensive evaluation of the updated PHDS Fulcrum40h High Purity Germanium (HPGe) detector system, benchmarking its performance, usability, and software capabilities against the current National Nuclear Security Administration (NNSA) Nuclear Emergency Support Team (NEST) HPGe Detector System Requirements Document. Systematic measurements were conducted using a single Fulcrum40h detector to assess key parameters including gamma efficiency and resolution, neutron detection efficiency, gamma pulse-pileup response, and gamma-to-neutron crosstalk. The Fulcrum40h system, acquired in August 2022, has undergone recent updates by PHDS to address deficiencies identified following the initial NEST requirements release. The results provide critical insights into the detector’s operational capabilities and compliance with NNSA NEST standards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Contrastive Machine Learning with Gamma Spectroscopy Data Augmentations for Detecting Shielded Radiological Material Transfers

Data analysis techniques can be powerful tools for rapidly analyzing data and extracting information that can be used in a latent space for categorizing observations between classes of data. Machine learning models that exploit learned data relationships can address a variety of nuclear nonproliferation challenges like the detection and tracking of shielded radiological material transfers. The high resource cost of manually labeling radiation spectra is a hindrance to the rapid analysis of data collected from persistent monitoring and to the adoption of supervised machine learning methods that require large volumes of curated training data. Instead, contrastive self-supervised learning on unlabeled spectra can enhance models that are built on limited labeled radiation datasets. This work demonstrates that contrastive machine learning is an effective technique for leveraging unlabeled data in detecting and characterizing nuclear material transfers demonstrated on radiation measurements collected at an Oak Ridge National Laboratory testbed, where sodium iodide detectors measure gamma radiation emitted by material transfers between the High Flux Isotope Reactor and the Radiochemical Engineering Development Center. Label-invariant data augmentations tailored for gamma radiation detection physics are used on unlabeled spectra to contrastively train an encoder, learning a complex, embedded state space with self-supervision. A linear classifier is then trained on a limited set of labeled data to distinguish transfer spectra between byproducts and tracked nuclear material using representations from the contrastively trained encoder. The optimized hyperparameter model achieves a balanced accuracy score of 80.30%. Any given model—that is, a trained encoder and classifier—shows preferential treatment for specific subclasses of transfer types. Regardless of the classifier complexity, a supervised classifier using contrastively trained representations achieves higher accuracy than using spectra when trained and tested on limited labeled data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Geant4 Simulation of Cherenkov Photons in Perovskite CsPbBr 3 Gamma-Ray Detectors

Perovskite materials have recently attracted significant attention for hard X-ray and gamma-ray detection. Cherenkov light generated by fast electrons due to gamma-ray interaction with the material can be used to provide fast timing information. Here, in this study, we report Geant4 simulation results of Cherenkov photon generation, transport, and detection within perovskite CsPbBr3. The Cherenkov photon yield, energy spectrum and temporal distribution are investigated under different gamma-ray energy deposition within CsPbBr3. CsPbBr 3 has a similar Cherenkov photon yield as of TlBr that has demonstrated fast-timing capability based on Cherenkov light. The effect of crystal volume, surface finish and SiPM photon detection efficiency on the Cherenkov detection is also discussed. This work provides insights into Cherenkov processes of CsPbBr3.

Cherenkov photon