Estimation of Energy Use by Plug-In Hybrid Electric Vehicles; Validating Gamma Distribution for Representing Random Daily Driving Distance
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Abstract Gamma distributed delay differential equations (DDEs) arise naturally in many modelling applications. However, appropriate numerical methods for generic gamma distributed DDEs have not previously been implemented. Modellers have therefore resorted to approximating the gamma distribution with an Erlang distribution and using the linear chain technique to derive an equivalent system of ordinary differential equations (ODEs). In this work, we address the lack of appropriate numerical tools for gamma distributed DDEs in two ways. First, we develop a functional continuous Runge–Kutta (FCRK) method to numerically integrate the gamma distributed DDE without resorting to Erlang approximation. We prove the fourth-order convergence of the FCRK method and perform numerical tests to demonstrate the accuracy of the new numerical method. Nevertheless, FCRK methods for infinite delay DDEs are not widely available in existing scientific software packages. As an alternative approach to solving gamma distributed DDEs, we also derive a hypoexponential approximation of the gamma distributed DDE. This hypoexponential approach is a more accurate approximation of the true gamma distributed DDE than the common Erlang approximation but, like the Erlang approximation, can be formulated as a system of ODEs and solved numerically using standard ODE software. Using our FCRK method to provide reference solutions, we show that the common Erlang approximation may produce solutions that are qualitatively different from the underlying gamma distributed DDE. However, the proposed hypoexponential approximations do not have this limitation. Finally, we apply our hypoexponential approximations to perform statistical inference on synthetic epidemiological data to illustrate the utility of the hypoexponential approximation.
Probabilistic proofs of the Johnson-Lindenstrauss lemma imply that random projection can reduce the dimension of a data set and approximately preserve pairwise distances. If a distance being approximately preserved is called a success, and the complement of this event is called a failure, then such a random projection likely results in no failures. Assuming a Gaussian random projection, the lemma is proved by showing that the no-failure probability is positive using a combination of Bonferroni's inequality and Markov's inequality. This paper modifies this proof in two ways to obtain a greater lower bound on the no-failure probability. First, Bonferroni's inequality is applied to pairs of failures instead of individual failures. Second, since a pair of projection errors has a bivariate gamma distribution, this probability of a pair of successes is bounded using an inequality from [Jensen, 1969]. If n is the number of points to be embedded and μ is the probability of success, then this leads to an increase in the lower bound on the no-failure probability of $\frac{1}{2}$ ($\genfrac{}{}{0pt}{}{n}{2}$) (1- μ ) 2 is ($\genfrac{}{}{0pt}{}{n}{2}$) is even and $\frac{1}{2}$ (($\genfrac{}{}{0pt}{}{n}{2}$)-1) (1- μ ) 2 if ($\genfrac{}{}{0pt}{}{n}{2}$) is odd. For example, if n =10 5 points are to be embedded in k =10 4 dimensions with a tolerance of ϵ=0.1, then the improvement in the lower bound is on the order of 10 -14 . We also show that further improvement is possible if the inequality in [Jensen, 1969] extends to three successes, though we do not have a proof of this result.
The results obtained by measuring the angular and energy distributions of gamma rays originating from the inelastic scattering of 14.1-MeV neutrons by carbon and oxygen nuclei are presented. The measurements in question were performed by the tagged-neutron method in a beam of an ING-27 standard portable neutron generator. The angular distributions of gamma rays emitted by the 2{sup +} state of {sup 12}С at 4.43 MeVand the 3{sup −} state of {sup 16}O at 6.13 MeV were obtained.
Purpose: The authors propose an algorithm based on the k-d tree for nearest neighbor searching to improve the {gamma} calculation time for 2D and 3D dose distributions. Methods: The {gamma} calculation method has been widely used for comparisons of dose distributions in clinical treatment plans and quality assurances. By specifying the acceptable dose and distance-to-agreement criteria, the method provides quantitative measurement of the agreement between the reference and evaluation dose distributions. The {gamma} value indicates the acceptability. In regions where {gamma}{<=}1, the predefined criterion is satisfied and thus the agreement is acceptable; otherwise, the agreement fails. Although the concept of the method is not complicated and a quick naieve implementation is straightforward, an efficient and robust implementation is not trivial. Recent algorithms based on exhaustive searching within a maximum radius, the geometric Euclidean distance, and the table lookup method have been proposed to improve the computational time for multidimensional dose distributions. Motivated by the fact that the least searching time for finding a nearest neighbor can be an O(log N) operation with a k-d tree, where N is the total number of the dose points, the authors propose an algorithm based on the k-d tree for the {gamma} evaluation in this work. Results: In the experiment, the authors found that the average k-d tree construction time per reference point is O(log N), while the nearest neighbor searching time per evaluation point is proportional to O(N{sup 1/k}), where k is between 2 and 3 for two-dimensional and three-dimensional dose distributions, respectively. Conclusions: Comparing with other algorithms such as exhaustive search and sorted list O(N), the k-d tree algorithm for {gamma} evaluation is much more efficient.
Here, the validity of the gamma distribution in describing the neutron number probability distribution function for both isolated and coupled multiplying assemblies when constrained to reproduce the true mean and variance is investigated in lumped geometry by numerical comparison with kinetic Monte Carlo simulations. The mean and variance are obtained from numerical solution of moment equations constructed from the relevant forward Master equation with assembly coupling coefficients obtained from a view factor method. Numerical results for a two-group, two coupled assemblies model, with static and dynamic reactivity insertion, show that except for subcritical assemblies, the gamma distribution well-approximates the number distribution. Differences in the fast and thermal neutron population shapes are explained in terms of effective source strengths due to downscatter and coupling.
We perform spatial and spectral analyses of the LMC gamma-ray emission collected over 66 months by the Fermi Gamma-ray Space Telescope. In our spatial analysis, we model the LMC cosmic-ray distribution and gamma-ray production using observed maps of the LMC interstellar medium, star formation history, interstellar radiation field, and synchrotron emission. We use bootstrapping of the data to quantify the robustness of spatial model performance. We model the LMC gamma-ray spectrum using fitting functions derived from the physics of π{sup 0} decay, Bremsstrahlung, and inverse Compton scattering. We find the integrated gamma-ray flux of the LMC from 200 MeV to 20 GeV to be 1.37 ± 0.02 × 10{sup −7} ph cm{sup −2} s{sup −1}, of which we attribute about 6% to inverse Compton scattering and 44% to Bremsstrahlung. From our work, we conclude that the spectral index of the LMC cosmic-ray proton population is 2.4 ± 0.2, and we find that cosmic-ray energy loss through gamma-ray production is concentrated within a few 100 pc of acceleration sites. Assuming cosmic-ray energy equipartition with magnetic fields, we estimate LMC cosmic rays encounter an average magnetic field strength ∼3 μG.
Distributed energy resources, such as rooftop solar photovoltaics (PV), are likely to comprise a substantial fraction of new generation capacity in the United States. However, forecasting technology adoption based on people's willingness to pay (WTP) faces two major challenges: the stated-intention and omitted-variable biases. Previous solar adoption literature has neglected to address these two biases altogether. Here, we adopt a 'parameterization + calibration' approach to address both biases and estimate customers' WTP for PV. After collecting survey data on respondents' WTP for adopting PV, we characterize its empirical cumulative density function using a gamma distribution. We further calibrate the gamma distribution parameters using a national distributed PV adoption simulation model, finding the parameters that produce the best fit between simulated and historic solar adoption. We then show that the calibrated gamma distribution improves the raw WTP data after correcting for the two biases. Finally, we use our optimally-calibrated WTP to forecast market demand for residential PV at the county-level of the United States in 2020. Improving estimates of customer willingness to pay has significant implications for policy directly, e.g. estimating the effect of a proposed policy on technology adoption, and other regulatory processes that use forecasting, e.g. integrated resource planning.
The objective of the present work is to apply the Harris ansatz to coupled assemblies in a lumped setting, i.e., ignoring the neutron phase dependence, which hitherto has not been considered. A Master equation for the single-time joint distribution of neutron number in each assembly, accounting for transfer of neutrons from one assembly to another via leakage transition probabilities and intercept or view factors is derived from which equations for the mean and variance in each assembly are developed. Because of the neutronic coupling, it is necessary to additionally compute the correlation function between pairs of assemblies which gives an expanded set of moment equations to solve. The reactivity of each assembly is allowed to vary with time, although a formal mechanism that is responsible for reactivity coupling between assemblies is not considered or proposed. Following Harris, it is then hypothesized that the number distribution in each assembly is a gamma distribution with assembly-specific mean and variance computed exactly from the moment equations. Illustrative numerical results are presented for the moments of a system of four coupled assemblies under various reactivity and neutronic coupling scenarios. The gamma distribution is then used to compute the probability that the neutron population exceeds a threshold value in any assembly. The report concludes with a discussion of recommended further work on this problem.
Using BlackHat in conjunction with SHERPA, we have computed next-to-leading order QCD predictions for a variety of distributions in Z,{gamma}*+1, 2, 3-jet production at the Tevatron, where the Z boson or off-shell photon decays into an electron-positron pair. We find good agreement between the next-to-leading order results for jet p{sub T} distributions and measurements by CDF and D0. We also present jet-production ratios, or probabilities of finding one additional jet. As a function of vector-boson p{sub T}, the ratios have distinctive features which we describe in terms of a simple model capturing leading logarithms and phase-space and parton-distribution-function suppression.
The mode-switching phenomenon of PSR B0329+54 is investigated based on the long-term monitoring from 2003 September to 2009 April made with the Urumqi 25 m radio telescope at 1540 MHz. At that frequency, the change of relative intensity between the leading and trailing components is the predominant feature of mode switching. The intensity ratios between the leading and trailing components are measured for the individual profiles averaged over a few minutes. It is found that the ratios follow normal distributions, where the abnormal mode has a greater typical width than the normal mode, indicating that the abnormal mode is less stable than the normal mode. Our data show that 84.9% of the time for PSR B0329+54 was in the normal mode and 15.1% was in the abnormal mode. From the two passages of eight-day quasi-continuous observations in 2004, supplemented by the daily data observed with the 15 m telescope at 610 MHz at Jodrell Bank Observatory, the intrinsic distributions of mode timescales are constrained with the Bayesian inference method. It is found that the gamma distribution with the shape parameter slightly smaller than 1 is favored over the normal, log-normal, and Pareto distributions. The optimal scale parameters of the gamma distribution are 31.5 minutes for the abnormal mode and 154 minutes for the normal mode. The shape parameters have very similar values, i.e., 0.75{sup +0.22}{sub -0.17} for the normal mode and 0.84{sup +0.28}{sub -0.22} for the abnormal mode, indicating that the physical mechanisms in both modes may be the same. No long-term modulation of the relative intensity ratios was found for either mode, suggesting that the mode switching was stable. The intrinsic timescale distributions, constrained for this pulsar for the first time, provide valuable information to understand the physics of mode switching.
Purpose: In vivo range verification is one of the most important parts of proton therapy to fully utilize its benefits delivering high radiation dose to tumor, while sparing the normal tissue with the so-called Bragg peak. Currently, however, range verification method is not used in clinics. The purpose of the present study is to optimize and evaluate the configuration of an array-type prompt gamma measurement system on determining distal dose edge for in vivo range verification of proton therapy. Methods: To effectively measure the prompt gammas against the background gammas, the Monte Carlo simulations with the MCNPX code were employed in optimizing the configuration of the measurement system, and the Monte Carlo method was also used to understand the effect of the background gammas, mainly neutron capture gammas, in the measured gamma distribution. To reduce the effect of the background gammas, the optimized energy window of 4-10 MeV in measuring the prompt gammas was employed. A parameterized source was used to maximize computation speed in the optimization study. A simplified test measurement system, using only one detector moving from one measurement location to the next, was constructed and applied to therapeutic proton beams of 80-220 MeV. For accurate determination of the distal dose edge, the sigmoidal curve-fitting method was applied to the measured distributions of the prompt gammas, and then, the location of the half-value between the maximum and minimum value in the curve-fitting was determined as the distal dose edge and compared with the beam range assessed by the proton dose distribution. Results: The parameterized source term employed in optimization process improved the calculation speed by up to {approx}300 times. The optimization study indicates that an array-type measurement system with 3, 2, 2, and 150 mm for scintillator thickness, slit width, septal thickness, and slit length, respectively, can effectively measure the prompt gamma distributions minimizing the contribution of background gammas. The present results show that a few hundred counts of prompt gammas can be easily obtained by measuring 10 s at each measurement location for proton beams of {approx}4 nA. The distal dose edges determined by the prompt gamma distribution are 5.45, 14.73, and 27.74 cm for proton beams of 5.17 (80 MeV), 14.99 (150 MeV), and 27.38 (220 MeV) cm, respectively. Conclusions: The results show that the array-type measurement system can measure prompt gamma distributions from a therapeutic proton beam within a short measurement time, and that the distal dose edge can be determined within a few millimeters of error without using any sophisticated analysis.
Particle density fluctuations in the scrape-off layer of magnetically confined plasmas, as measured by gas-puff imaging or Langmuir probes, are modeled as the realization of a stochastic process in which a superposition of pulses with a fixed shape, an exponential distribution of waiting times, and amplitudes represents the radial motion of blob-like structures. With an analytic formulation of the process at hand, we derive expressions for the mean squared error on estimators of sample mean and sample variance as a function of sample length, sampling frequency, and the parameters of the stochastic process. Employing that the probability distribution function of a particularly relevant stochastic process is given by the gamma distribution, we derive estimators for sample skewness and kurtosis and expressions for the mean squared error on these estimators. Numerically, generated synthetic time series are used to verify the proposed estimators, the sample length dependency of their mean squared errors, and their performance. We find that estimators for sample skewness and kurtosis based on the gamma distribution are more precise and more accurate than common estimators based on the method of moments.
The orientation of falling ice particles directly influences estimates of microphysical and radiative bulk quantities as well as in situ retrievals of size, shape, and mass. However, retrieval efforts and bulk calculations often incorporate very basic orientations or ignore these effects altogether. To address this deficiency, this study develops a general method for projecting bulk distributions of particle shape for arbitrary orientations. The Amoroso distribution provides the most general bulk aspect ratio distribution for gamma-distributed particle axis lengths. The parameters that govern the behavior of this aspect ratio distribution depend on the assumed relationship between mass, maximum dimension, and aspect ratio. Individual spheroidal geometry allows for eccentricity quantities to linearly map onto ellipse analogs, whereas aspect ratio quantities map nonlinearly. For particles viewed from their side, this analytic distinction leads to substantially larger errors in projected aspect ratio than for projected eccentricity. Distribution transformations using these mapping equations and numerical integration of projection kernels show that both truncation of size distributions and changes in Gaussian dispersion can alter the modality and shape of projection distributions. As a result, the projection process can more than triple the relative entropy between the spheroidal and projection distributions for commonly assumed model and orientation parameters. This shape uncertainty is maximized for distributions of highly eccentric particles and for particles like aggregates that are thought to fall with large canting-angle deviations. As a result, the methods used to report projected aspect ratios and the corresponding values should be questioned.
We study the potential of the LHC to discover the signal of dark matter associated production with a photon induced by a dimension six effective operator, including next-to-leading order QCD corrections. We investigate the main backgrounds from the standard model, i.e. Z boson and a photon associated production with invisible decay of Z boson, and Z boson and a jet production with the jet misidentified as a photon. We find that the p{sub T}{sup {gamma}} distributions of the backgrounds decrease faster than that of the signal with increasing of the transverse momentum of the photon. The {eta}{sup {gamma}} distributions of the backgrounds are almost flat in the full range of {eta}{sup {gamma}}. In contrast, the signal lies mainly in the central region of {eta}{sup {gamma}}. These characteristics may help to select the events in experiments. We show that in the parameter space allowed by the relic abundance constraint, which we have calculated at the next-to-leading-order QCD level, the LHC with {radical}(S)=7 TeV may discover this signal at the 5{sigma} level after collecting an integrated luminosity of 1 fb{sup -1}. On the other hand, if this signal is not observed at the LHC, we can set a lower limit on the new physics scale at the 3{sigma} level.
Fluctuation Electron Microscopy (FEM) is a technique that examines the fluctuations in electron scattering across a uniformly thin amorphous sample. The statistics of the intensity fluctuations, mean and variance, reveal any underlying medium-range order present in the structure. The goals of this project were: (1) To determine the fundamentals of the scattering physics that gives rise to the variance signal in fluctuation electron microscopy (FEM); (2) To use these discoveries to find ways to quantify FEM; (3) To apply the FEM method to interesting and technologically important families of amorphous materials, particularly those with important applications in energy-related processes. Excellent progress was made in items (1) and (2). In stage (3) we did not examine the metamict zircons, as proposed. Instead, we examined films of polycrystalline and amorphous semi-conducting diamond. Significant accomplishments are: (1) A Reverse Monte Carlo procedure was successfully implemented to invert FEM data into a structural model. This is computer-intensive, but it demonstrated that diffraction and FEM data from amorphous silicon are most consistent with a paracrystallite model. This means that there is more diamond-like topology present in amorphous silicon than is predicted by the continuous random network model. (2) There is significant displacement decoherence arising in diffraction from amorphous silicon and carbon. The samples are being bombarded by the electron beam and atoms do not stay still while being irradiated – much more than was formerly understood. The atom motions cause the destructive and constructive interferences in the diffraction pattern to fluctuate with time, and it is the time-averaged speckle that is being measured. The variance is reduced by a factor m, 4 ≤ m ≤ 1000, relative to that predicted by kinematical scattering theory. (3) Speckle intensity obeys a gamma distribution, where the mean intensity $ \overline{I}\ $ and m are the two parameters governing the shape of the gamma distribution profile. m is determined by the illumination spatial coherence, which is normally very high, and mostly by the displacement decoherence within the sample. (4) Amorphous materials are more affected by the electron beam than are crystalline materials. Different samples exhibit different disruptibility, as measured by the effective values of m that fit the data. (5) Understanding the origin of the displacement decoherence better should lead to efficient methods for computing the observed variance from amorphous materials.
We obtain in closed form the probability distribution for individual measurements of the stress-energy tensor of two-dimensional conformal field theory in the vacuum state, smeared in time against a Gaussian test function. The result is a shifted gamma distribution with the shift given by the previously known optimal quantum inequality bound. For small values of the central charge it is overwhelmingly likely that individual measurements of the sampled energy density in the vacuum give negative results. For the case of a single massless scalar field, the probability of finding a negative value is 84%. We also report on computations for four-dimensional massless scalar fields showing that the probability distribution of the smeared square field is also a shifted gamma distribution, but that the distribution of the energy density is not.