Environmental Stress Testing of the Single Sample Cylinder: A Proven Consensus Standard for Internal Gas Analysis (IGA) or Residual Gas Analysis (RGA)

In August 2008, Schuessler Consulting was contracted by NASA GSFC in support of the NASA Electronic Parts and Packaging (NEPP) program to perform two separate studies on moisture laden air in a stainless steel cylinder that had been designed to become a consensus standard for Test Method 1018. This Test Method was originally released for hybrids under Mil. Std. 883 but was quickly utilized on other microelectronic devices under the auspice of Mil. Std. 750. The cylinder had subsequently been fabricated for the 750 community. It was back-filled with moist air and subsequently analyzed over a period of time under a previous NASA contract. It had been shown that moisture in the 4000 - 5000 ppm range could be analyzed rather precisely with a mass spectrometer, commonly referred to as a Residual Gas Analyzer (RGA). The scope of this study was to ascertain if the composition and precision varied as a function of thermal shock at sub-zero temperatures and whether there was consensus when the standard was submitted to other RGA units. It was demonstrated and published that the consensus standard would yield precise RGA data for moisture within +/- 1% when optimized for a given RGA unit. It has been subsequently shown in this study at Oneida Research Services, that sub-zero storage did not affect that precision when a well-defined protocol for the analysis was followed. The consensus standard was taken to a second facility for analysis where it was found that moisture adsorption on the transfer lines caused precision to drop to +/- 12%. The Single Sample Cylinder (SSC) is a one liter stainless steel cylinder with associated sampling valves and has considerable weight and volume. But this considerable size allows for approximately 300 gas samples of the same composition to be delivered to any RGA unit. Lastly, a smaller cylinder, approximately 75 cc, of a second consensus standard was fabricated and tested with a different mix of fixed gases where moisture was kept in the 100 ppm range. This second standard has the potential of providing 30 gaseous samples and can be readily shipped to any analytical facility that desires to generate comparison RGA data. A series of comparison residual gas analyses was performed at the Honeywell Federal Manufacturing & Technologies facility in the National Nuclear Facility Administration s plant in Kansas City to complete this project. It was shown that improvements in the precision of a given RGA unit can be done by controlling the cycle time for each analysis and increasing analysis temperatures to minimize moisture adsorption. It was also found that a "one time event" in the subzero storage of the large SSC did not effect the units ability to continuously supply precise samples of the same chemistry, however the "event" caused a permanent +8% shift in the reported value of the moisture content. Lastly, a set of SSC RGA results was plotted on a common graph with DSCC "correlation study" RGA data. The result demonstrates the ability of the SSC to remove many of the individual variances that single, individual samples introduce. The consensus standards are now in storage at Oneida Research Services, one of the DSCC certified houses that does RGA to Military Standards, where they await future studies. The analytical data and the operational parameters of the instruments used are provided in the following discussion. Limitations and suggested means for improvement of both precision and accuracy are provided.

Schuessler, Philipp WH↗

X-ray diffraction, differential scanning calorimetry and evolved gas analysis of aged plutonium tetrafluoride (PuF4)

A 30 year-old PuF4 sample consisting of brown powder (PuF4-b) and pink granules (PuF4-p) was analyzed. X-ray difraction shows the bulk is comprised of three compounds: PuF4, PuO2, and PuF4·1.6H2O. Broadening of PuF4 XRD peaks suggests possible a-damage. After annealing at 650 °C, crystalline PuF4 and PuO2 remain. Thermogravimetric analysis and diferential scanning calorimetry—with simultaneous evolved gas analysis—of the separated PuF4-p and PuF4-b components reveal a distinct sequence of reactions. Dehydration occurs between~90 and 300 °C. Exothermic annealing of the a-damage occurs in two stages: at 350–355 °C and at 555–558 °C. Hydrofuoric acid, fuorine and helium desorb during the frst exotherm. Above 700 °C, PuF4 reacts with PuO2, resulting in oxygen release and mass loss.

PuF4, dsc, differential scanning calorimetry, plut↗

Foaming during Nuclear Waste Melter Feeds Conversion to Glass: Application of Evolved Gas Analysis

During the final stages of batch-to-glass conversion in a waste-glass melter, gases evolving in the cold cap produce primary foam, the formation and collapse of which control the glass production rate via its effect on heat transfer to the reacting batch. We performed quantitative evolved gas analysis (EGA) for several HLW melter feeds with temperatures ranging from 100 °C to 1150 °C, the whole temperature span in a cold cap. EGA results were supplemented with visual observation of batch-to-glass transition using the feed expansion tests. Upon heating, most of the gases—mainly H2O, CO2, NO, NO2, N2 and O2—evolve at temperatures below 700 °C and escape directly to the atmosphere through open porosity. However, as open porosity closes when enough glass-forming melt appears at 720 °C, the residual gas evolution leads to the formation of primary foam. We found that primary foaming is mostly caused by the decomposition of residual carbonates, though oxygen evolution from iron-redox reaction can also play a role. We also show that the gas evolution shifts to a higher temperature when the heating rate increases. The implications for the mathematical modeling of foam layer in the cold cap are presented.

Hujova, Miroslava↗

Thermal and Evolved Gas Analysis of "Nanophase" Carbonates: Implications for Thermal and Evolved Gas Analysis on Mars Missions

Data collected by the Mars Phoenix Lander's Thermal and Evolved Gas Analyzer (TEGA) suggested the presence of calcium-rich carbonates as indicated by a high temperature CO2 release while a low temperature (approx.400-680 C) CO2 release suggested possible Mg- and/or Fe-carbonates [1,2]. Interpretations of the data collected by Mars remote instruments is done by comparing the mission data to a database on the thermal properties of well-characterized Martian analog materials collected under reduced and Earth ambient pressures [3,4]. We are proposing that "nano-phase" carbonates may also be contributing to the low temperature CO2 release. The objectives of this paper is to (1) characterize the thermal and evolved gas proper-ties of carbonates of varying particle size, (2) evaluate the CO2 releases from CO2 treated CaO samples and (3) examine the secondary CO2 release from reheated calcite of varying particle size.

Lauer, Howard V., Jr.↗

COSO Fluid Inclusion Gas Analysis

Fluid inclusion gas analysis for wells in COSO geothermal area, California. Analyses used in developing fluid inclusion stratigraphy for wells and defining fluids across the geothermal fields. Each sample has mass spectrum counts for 180 chemical species.

15 GEOTHERMAL ENERGY↗

Salton Sea Fluid Inclusion Gas Analysis

Fluid inclusion gas analysis for wells in Salton Sea geothermal area, California. Analyses used in developing fluid inclusion stratigraphy for wells and defining fluids across the geothermal fields. Each sample has mass spectrum counts for 180 chemical species.

15 GEOTHERMAL ENERGY↗

Fluid Inclusion Gas Analysis

Fluid inclusion gas analysis for wells in various geothermal areas. Analyses used in developing fluid inclusion stratigraphy for wells and defining fluids across the geothermal fields. Each sample has mass spectrum counts for 180 chemical species.

15 GEOTHERMAL ENERGY↗

Fluid Inclusion Gas Analysis

Fluid inclusion gas analysis for wells in various geothermal areas. Analyses used in developing fluid inclusion stratigraphy for wells and defining fluids across the geothermal fields. Each sample has mass spectrum counts for 180 chemical species.

15 GEOTHERMAL ENERGY↗

Fluid Inclusion Gas Analysis

Fluid inclusion gas analysis for wells in various geothermal areas. Analyses used in developing fluid inclusion stratigraphy for wells and defining fluids across the geothermal fields. Each sample has mass spectrum counts for 180 chemical species.

15 GEOTHERMAL ENERGY↗

Fluid Inclusion Gas Analysis

Fluid inclusion gas analysis for wells in various geothermal areas. Analyses used in developing fluid inclusion stratigraphy for wells and defining fluids across the geothermal fields. Each sample has mass spectrum counts for 180 chemical species.

15 GEOTHERMAL ENERGY↗

Fluid Inclusion Gas Analysis

Fluid inclusion gas analysis for wells in various geothermal areas. Analyses used in developing fluid inclusion stratigraphy for wells and defining fluids across the geothermal fields. Each sample has mass spectrum counts for 180 chemical species.

15 GEOTHERMAL ENERGY↗

Fluid Inclusion Gas Analysis

Fluid inclusion gas analysis for wells in various geothermal areas. Analyses used in developing fluid inclusion stratigraphy for wells and defining fluids across the geothermal fields. Each sample has mass spectrum counts for 180 chemical species.

15 GEOTHERMAL ENERGY↗

Fluid Inclusion Gas Analysis

Fluid inclusion gas analysis for wells in various geothermal areas. Analyses used in developing fluid inclusion stratigraphy for wells and defining fluids across the geothermal fields. Each sample has mass spectrum counts for 180 chemical species.

15 GEOTHERMAL ENERGY↗

Integrated Exhaust-Gas-Analysis System

Gas-Analysis system includes eight commercial gas analyzers and data-processing and calibration electronics. Two microprocessors range analyzers, calibrate system, process raw data to units of concentration, and make all system information available to facility research computer and to operator. After initial setup, system operates several hours without significant operator attention. Saves considerable operator time.

Anderson, R.↗

Capability of the Gas Analysis and Testing Laboratory at the NASA Johnson Space Center

The Gas Analysis and Testing Laboratory is an integral part of the testing performed at the NASA Johnson Space Center. The Gas Analysis and Testing Laboratory is a high performance laboratory providing real time analytical instruments to support manned and unmanned testing. The lab utilizes precision gas chromatographs, gas analyzers and spectrophotometers to support the technology development programs within the NASA community. The Gas Analysis and Testing Laboratory works with a wide variety of customers and provides engineering support for user-specified applications in compressed gas, chemical analysis, general and research laboratory

Broerman, Craig↗

Capability of the Gas Analysis and Testing Laboratory at the NASA Johnson Space Center

The Gas Analysis and Testing Laboratory is an integral part of the testing performed at the NASA Johnson Space Center. The Gas Analysis and Testing Laboratory is a high performance laboratory providing real time analytical instruments to support manned and unmanned testing. The lab utilizes precision gas chromatographs, gas analyzers and spectrophotometers to support the technology development programs within the NASA community. The Gas Analysis and Testing Laboratory works with a wide variety of customers and provides engineering support for user-specified applications in compressed gas, chemical analysis, general and research laboratory.