Search NASA⌕ Search

SEARCH · Search NASA

Results for “gas meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Demonstration and Evaluation of a Non-Invasive, Low-Cost, Strap-On Sensor for Natural Gas Meters

The U.S. General Services Administration (GSA) is interested in installing internet-connected, gas submeters to better understand gas consumption in its portfolio of buildings. The GSA in partnership with the National Renewable Energy Laboratory conducted a demonstration to assess a specific submeter technology. This technology was implemented at two GSA separate facilities located in Dallas, Texas. This demonstration evaluated hardware and software installations and integrations, data integrity and accuracy, and included an economic analysis. This demonstration evaluated a gas submeter technology provided by the vendor Vata Verks, who produces a non-invasive strap-on submeter. The company was founded with a mission to conserve water (and eventually gas) cheaply and simply, as explained on its website. The product intends to streamline submeter deployments for gas and water by eliminating most hardware costs while allowing for easy integration of submetered data into other systems such as the Building Automation System and removing tenant and building disruption This demonstration evaluated the product features when used on a gas utility meter.

03 NATURAL GAS↗

Tracking the PACE of household energy usage: Energy usage impacts of projects financed through Property Assessed Clean Energy programs in California

This report examines the household-level energy impacts of residential property assessed clean energy (R-PACE) projects using normalized metered energy consumption methods. Our analysis covers projects that occurred through an R-PACE program between 2009 and 2017 and includes more than 25,000 electricity meters and 15,000 gas meters. We employ a comparison group, drawn from other R-PACE households with similar locational and usage characteristics whose projects were implemented at different times, to control for some non-project and non-weather factors that may impact energy use. We find that projects consisting of energy efficiency technologies save, on average, about 3% of household electricity usage and 3.5% of household gas usage. R-PACE financing, however, can be used to install central heating or air conditioning equipment for the first time. These projects would be expected to increase energy consumption. Since our data do not directly indicate which projects are new installations, we develop a simple algorithm for identifying them. Removing these inferred installation projects yields average savings of about 5% for electricity and 6% for gas for those households that remain in the sample. Given the mild California climate and the results of another study of similar California projects using similar methods, these results are in line with expectations. Solar PV projects yield large reductions in grid electricity use, averaging 69% of household consumption. We estimate that, collectively, all R-PACE projects installed in California through 2019 would generate annual reductions in grid-tied electricity consumption of 506 GWh (mostly due to solar PV) and gas consumption reductions of 2 million therms in a normal weather year. These impacts are equivalent to the electricity consumption of about 74,000 California households (including both efficiency and PV generation) and the gas consumption of about 4700 California households.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirical Estimation of the Energy Impacts of Projects Installed through Residential Property Assessed Clean Energy Financing Programs in California

We examine the energy use impacts of energy efficiency and solar PV projects financed by residential property assessed clean energy (R-PACE) programs in California. We leverage household-level interval meter data to apply normalized metered energy consumption (NMEC) methods at significant scale—more than 25,000 electric meters and more than 15,000 gas meters. We develop a comparison group to account for non-project-related changes in usage. The projects include homes that replaced existing HVAC equipment with higher-efficiency units and homes that installed central heating or air conditioning equipment for the first time. We have limited information on pre-project household equipment stock so we develop a method to infer new installations. We find that projects that installed energy efficiency technologies reduce electricity consumption by approximately 3% and gas consumption by approximately 3.5% on average. When we remove homes that installed new cooling and heating equipment for the first time, savings rise to approximately 5% for electricity and approximately 6% for gas. Given the California climate and the results of an existing study of similar California projects, these results are in line with expectations. Solar PV projects produce electricity that offsets approximately 69% of household electricity consumption on average. We estimate that California R-PACE projects installed through the end of 2019 produce annual reductions in grid-tied electricity consumption of 506 GWh (equivalent to the electricity consumption of approximately 74,000 California households) and gas consumption reductions of 2 million therms (equivalent to the gas consumption of approximately 4700 California households) in a typical weather year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

System and method for characterization of retrofit opportunities in building using data from communicating thermostats

Systems and methods for characterization of retrofit opportunities are described. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. In some embodiments, a model-predicted indoor temperature may be fitted against thermal data measured by a thermostat at the building. The thermal characteristic of the building may comprise a thermal insulation, an air leakage rate and/or an HVAC efficiency. The method may be used to determine, using the at least one computing device, suitability of the building for a retrofit opportunity to improve energy efficiency of the building. Determining the suitability may comprise evaluating the one or more thermal characteristics. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter.

Zeifman, Michael↗

System and method for characterization of retrofit opportunities in building using data from interval meters

Systems and methods for characterization of retrofit opportunities are described. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. In some embodiments, a model-predicted indoor temperature may be fitted against thermal data measured by a thermostat at the building. The thermal characteristic of the building may comprise a thermal insulation, an air leakage rate and/or an HVAC efficiency. The method may be used to determine, using the at least one computing device, suitability of the building for a retrofit opportunity to improve energy efficiency of the building. Determining the suitability may comprise evaluating the one or more thermal characteristics. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter.

Zeifman, Michael↗

System and method for characterization of air leakage in building using data from communicating thermostats and/or interval meters

Systems and methods for characterization of retrofit opportunities are described. Some embodiments are directed to methods for determining the air leakage rate of a building, and accordingly, for determining suitability of sealing of air leaks to improve the energy efficiency of a building. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter. To isolate the impact of air leakage, subsets of the HVAC runtime data at time intervals selected to have substantially the same conditions, but different wind speeds, may be computed.

Zeifman, Michael↗

Triple bubbler system, fast-bubbling approach, and related methods

A triple bubbler system includes a first fluid probe, a second fluid probe, a third fluid probe, a gas source operably coupled to the first fluid probe, the second fluid probe, and the third fluid probe and configured to meter gas through the first fluid probe, the second fluid probe, and the third fluid probe to form bubbles at tips of each of the first fluid probe, the second fluid probe, and the third fluid probe, and a cover member disposed over the tips of the first, second, and third fluid probes and configured to at least partially prevent bubbles formed and escaping the tips of the first, second, and third fluid probes from interfering with other bubbles formed at each other tips. The bubbler system includes a thermocouple having a plurality of junctions disposed along an axis parallel to longitudinal axes of the first, second, and third fluid probes.

Galbreth, Gregory G.↗

Experimental Investigation of Gaseous Mixtures of Ethane, Methane, and Carbon Dioxide as an Alternative to Conventional Fuel in Spark Ignition Engines

This study investigates the viability and performance of certain synthetic fuels in spark ignition internal combustion engine based stationary power generation wherein the fuel comprises a mixture of methane and ethane in high dilutions of carbon dioxide (CO 2 ). The fuel of concern is a byproduct of a novel method for producing ethylene from ethane. The byproduct gas mixture has a concentration of approximately 41% CO 2 , 40% ethane, and 5% methane by weight along with other minor compounds. Varying mixtures of ethane and methane combined with between 42% and 46% by weight CO 2 were used to evaluate the viability and efficiency of this fuel to operate in existing internal combustion engines as a means of reducing emissions and increasing industrial process efficiency. A 13 hp gasoline generator was repurposed as a test stand by incorporating a modified fuel induction system and instrumentation for data collection. A gas metering and mixing system was installed to precisely control the mass flow of gases induced into the engine. Various instrumentations were installed to monitor in-cylinder pressure, temperature at various locations, emissions, and fuel and airflow rates. Varying fuel mixtures and loads were tested and compared to gasoline. It was found that under a high load, the mixed gas was able to generate comparable thermal efficiency and power to gasoline. But under no load or a part load condition the indicated thermal efficiency was found to be about 21% lower than that of gasoline. Further, the mixed gas also resulted in up to 50% reduction in CO and NOx emissions when compared to gasoline.

42 ENGINEERING↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Meter-scale plasma waveguides for multi-GeV laser wakefield acceleration

Here, we present results from two new techniques for the generation of meter-scale, low density (~10 17 cm -3 on axis) plasma waveguides, the “two-Bessel” technique, and the “self-waveguiding” technique. Plasma waveguides of this density and length range are needed for demonstration of a ~10 GeV laser wakefield accelerator module, key for future staging for a ~TeV lepton collider. Both techniques require the use of high quality ultrashort pulse Bessel beams to efficiently and uniformly ionize hydrogen gas in meter-scale supersonic gas jets via optical field ionization. We review these two techniques, describe our meter-scale gas jets, and present a new method for correction of optical aberrations in Bessel beams. Finally, we briefly present results from recent experiments employing one of our techniques, demonstrating quasi-monoenergetic acceleration of ~5 GeV electron bunches in 20 cm long, low density plasma waveguides.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Benchmarking of hydrodynamic plasma waveguides for multi-GeV laser-driven electron acceleration

Hydrodynamic plasma waveguides initiated by optical field ionization have recently become a key component of multi-GeV laser wakefield accelerators. Here, we present the most complete and accurate experimental and simulation-based characterization to date, applicable to current multi-GeV experiments and future 100 GeV-scale laser plasma accelerators. Crucial to the simulations is the correct modeling of intense Bessel beam interaction with meter-scale gas targets, the results of which are used as initial conditions for hydrodynamic simulations. The simulations are in good agreement with our experiments measuring evolving plasma and neutral hydrogen density profiles using two-color short pulse interferometry, enabling realistic determination of the guided mode structure for application to laser-driven plasma accelerator design. Published by the American Physical Society 2024

Physics↗

Combustion control using spiking neural networks

A system that controls a combustion engine stores network vectors in a memory that represent diverse and distinct spiking neural networks. The system decodes the network vectors and trains and evaluates the spiking neural networks. The system duplicates selected network vectors and crosses-over the duplicated network vectors that represent modified spiking neural networks. The system mutates the crossed-over duplicated network vectors by randomly modifying one or more portions of the crossing-over duplicated network vectors. The system meter exhaust gas into an intake manifold when an engine temperature exceeds a threshold, an engine load exceeds a threshold, an engine's rotation-per-minute rate exceeds a threshold, and a fuel flow exceeds a threshold. The system modifies fuel flow into an engine's combustion chamber on a cycle-to-cycle basis by the trained spiking neural network.

Puente, Brian P. Maldonado↗

Manufacture aluminum alloy tube from powder with a single-step extrusion via ShAPE

Mechanical performance of aluminum in terms of strength, wear and corrosion resistance, especially high-temperature strength has been shown to improve with the addition of transition metal (TM) elements of Fe, Cr, and Ti. However, these feedstock materials occur as powders. As such, the traditional fabrication process is complex and expensive because it requires multiple procedures and consumes considerable energy. This study developed Shear Assisted Processing and Extrusion (ShAPE) as a single-step process that manufactures tubes directly from Al-TM powders obtained via gas atomization. Meter-long Al-TM alloy tubes are extruded from powders with different processing conditions. The ShAPE tubes have very low porosity and the average density is 2.94 kg/cm 3 , which is equal to or higher than parts fabricated by hot extrusion and sintering. The powder-to-tube fabrication process was revealed and discussed by examining the microstructural evolution. The Vickers hardness of ShAPE tubes ranges from 110 to 140 HV through wall thickness and at different extrusion speeds. The variation in hardness was correlated with the extent of refinement of intermetallics and attributed to the shear deformation per unit extrusion length. Energy cost analysis shows that ShAPE save ~60% energy compared to the conventional sintering and extrusion processes. Results indicate ShAPE is a low-cost, high-efficiency manufacturing process for producing tubes from metallic powders.

36 MATERIALS SCIENCE↗

Development of a high charge 10 GeV laser electron accelerator

Low-density meter-scale plasma waveguides produced in meter-scale supersonic gas jets have paved the way for recent demonstrations of all-optical multi-gigaelectronvolt laser wakefield acceleration (LWFA). This paper reviews recent advances by the University of Maryland, which have enabled these results, focusing on the development of elongated supersonic gas jets up to ∼1 m in length, experimental and simulation studies of plasma waveguide formation, and a new three-stage model for relativistic pulse propagation dynamics in these waveguides. We also present results from recent LWFA experiments conducted at the Laboratory for Advanced Lasers and Extreme Photonics at Colorado State University demonstrating high charge, low divergence electron bunches to ∼10 GeV, with laser-to-electron beam efficiency of at least ∼30%.

Rockafellow, E. [Univ. of Maryland, College Park, ↗

Wakefield generation in hydrogen and lithium plasmas at FACET-II: Diagnostics and first beam-plasma interaction results

Plasma wakefield acceleration provides ultrahigh acceleration gradients of tens of GeV/m, providing a novel path toward efficient, compact, TeV-scale linear colliders, and high brightness free electron lasers. Critical to the success of these applications is demonstrating simultaneously high gradient acceleration, high energy transfer efficiency, and preservation of emittance, charge, and energy spread. Experiments at the FACET-II National User Facility at SLAC National Accelerator Laboratory aim to achieve all of these milestones in a single-stage plasma wakefield accelerator, providing a 10 GeV energy gain in a < 1 m plasma with high energy transfer efficiency. Such a demonstration depends critically on diagnostics able to measure emittance with mm mrad accuracy, energy spectra to determine both percent level energy spread, and broadband energy gain and loss, incoming longitudinal phase space, and matching dynamics. This paper discusses the experimental setup at FACET-II, including the incoming beam parameters from the FACET-II linac, plasma sources, and diagnostics developed to meet this challenge. Initial progress on the generation of beam ionized wakes in meter-scale hydrogen gas is discussed as well as commissioning of the plasma sources and diagnostics. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Validation of strongly coupled geomechanics and gas hydrate reservoir simulation with multiscale laboratory tests

In this work, we validate a coupled flow-geomechanics simulator for gas hydrate deposits, named T+M AM , performing two meter-scale laboratory experiments of gas hydrates for production by depressurization, replicating the gas hydrate deposit in the Ulleung Basin, East Sea, South Korea. The first experiment with a sand-only specimen is a 1D 1 m-scale depressurization test based on the excess gas method, which represents the grain coating hydrate growth. On the other hand, the second is a 3D 1.5 m-scale test with the excess water method for a sand-mud alternating layer system, representing the pore filling hydrate growth. We measure production and displacement at the top with different depressurization levels. In particular, the 3D test exhibits high coupling strength of substantial deformation induced by incompressibility of water and high deformability of the specimen. For validation, we match pressure, flow rate, and displacement between the experimental data and numerical results. Thus, we identify that T+M AM is a reliable simulator, which can be applied to fields in both permafrost and deep oceanic hydrate deposits of strongly coupled flow and geomechanics systems. This validation also implies that other coupled simulators based on the same coupling formulation as T+M AM can be validated when individual flow and geomechanics simulators are stable and reliable.

02 PETROLEUM↗

Virtual Metering for Monitoring Building Energy Consumption

The United States Department of Energy (DOE) has standard metering requirements of commercial buildings for optimizing energy performance. The guiding principles are to continuously track and optimize energy performance and install building-level meters for electricity, natural gas, and steam. Some buildings at Los Alamos National Laboratory (LANL) have physical submeters monitoring their energy consumption, but these meters have proven to be unreliable. And, in most cases, replacing them has proven to be a slow process. Installing new submeters also requires a temporary lockout of the circuit on which they are being installed. Many buildings at LANL contain laboratories with ongoing experiments or data centers, which makes an equipment power outage nearly impossible to plan. This inability to plan power outages results in long-term submeter failures. Although most submeters are eventually replaced, failures lead to missing consumption data for some unpredictable, extended time. A building automation system (BAS) is a system that provides control and monitoring on a building to maintain the operational performance of the building and occupancy comfort. Many buildings at LANL currently have a BAS, and all new renovations and installs will include installing a BAS if one does not already exist. The intended purpose for a BAS is primarily to monitor the health and efficiency of a building; however, it is also possible to calculate equipment power and energy consumption using BAS information. This project aims to use virtual meters to monitor building energy consumption as a cost-effective and minimally labor-intensive alternative to installing physical submeters. The fault detection and diagnostics tool, SkySpark, provides a centralized database for all the data from the various BAS that are active at LANL. This data includes the information that is needed to create virtual meters for heating, ventilating, and air conditioning (HVAC) systems in most buildings, including heating and cooling loads. 9 This report begins with a detailed summary of the project, including the reasoning, procedure, and results. The specific processes of creating the various virtual meters are then identified. Then the limitations are discussed. And, lastly, the results and future potential are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗