Search NASA⌕ Search

SEARCH · Search NASA

Results for “gas scintillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Gamma-ray astronomy using a high pressure gas scintillation drift chamber with a waveshifting fiber readout

We describe a balloon-borne hard X-ray telescope called SIGHT (Scintillation Imaging Gas-filled Hard X-ray Telescope). SIGHT is a high sensitivity, good energy resolution instrument that images in the 30 to 300 keV region. We discuss the development of a large area, 20 atmosphere, position sensitive xenon gas scintillation drift chamber which is the gamma-ray detector at the heart of the telescope package. Results of the development of the novel waveshifting fiber readout for this chamber are presented.

Wilkerson, J.↗

An imaging gas scintillation proportional counter for use in X-ray astronomy

An imaging gas scintillation proportional counter (GSPC) has been constructed for use in X-ray astronomy. The IGSPC consists of a gas scintillation proportional counter (GSPC) with a 1 micron polypropylene window coupled to a multiwire proportional counter (MWPC) via a calcium fluoride window. The MWPC, filled with a mixture of argon, methane, and tetrakis (dimethylamino) ethylene, detects the UV photons emitted by the xenon gas in the GSPC. The measured energy resolution is 17.0 percent (fwhm) and 8.0 percent (fwhm) at 1.5 keV and 5.9 keV, respectively. The measured position resolution is 1.9 mm (fwhm) and 0.9 mm (fwhm) at 1.5 and 5.9 keV, respectively. Possible astrophysical observations which can be performed with an IGSPC at the focal plane of a grazing incidence telescope are also discussed.

Hailey, C. J.↗

Properties of an imaging gas scintillation proportional counter

An instrument which combines the improved energy resolution offered by the gas scintillation proportional counter (GSPC) with the submillimeter imaging capabilities of the multiwire proportional counter (MWPC) is described. The imaging gas scintillation proportional counter detects the centroid of the UV light excited by X-ray photons interacting in the noble gas of the GSPC with a UV sensitive gas in the MWPC. The prototype counter yields a measured performance of 9% (FWHM) energy resolution and 0.9 mm (FWHM) spatial resolution at 6 keV. Further design refinements should achieve 18% (FWHM) energy resolution and 0.6 mm (FWHM) spatial resolution at 1 keV.

Ku, W. H.-M.↗

An imaging gas scintillation proportional counter for the detection of subkiloelectron-volt X-rays

A large area imaging gas scintillation proportional counter (IGSPC) was constructed for use in X-ray astronomy. The IGSPC consists of a gas scintillation proportional counted (GSPC) with a micron polyprotylene window coupled to a multiwire proportional counter (MWPC) via a calcium fluoride window. Over a sensitive area of 21 cu cm the instrument has a measured energy resolution of 17.5% (FWHM) and 1.9 mm (FWHM) spatial resolution at 1.5 keV.

Hailey, C. J.↗

A large area imaging gas scintillation proportional counter for use in X-ray astronomy

A large area (200 sq cm), broad bandwidth (0.1-70 keV), imaging gas scintillation proportional counter (IGSPC) has been constructed for use in X-ray astronomy. The IGSPC consists of a high pressure xenon gas scintillation proportional counter (GSPC) coupled to a multi-wire proportional counter (MWPC) via a calcium fluoride window. THe MWPC, filled with a mixture of argon, methane, and tetrakis (dimethylamino) ethylene, detects the UV photons emitted by the xenon gas in the GSPC. The detector has a measured energy resolution of 8.0 percent (FWHM) and 4.3 percent (FWHM) at 5.9 keV and 22.1 keV, respectively. The predicted spatial resolution of the detector is less than 1 mm (FWHM) between 3-22 keV and 37-60 keV. A method to determine the three-dimensional location of detected X-rays is described. In addition, a combination of discrimination schemes designed to reduce the non-X-ray background in the IGSPC by more than two orders of magnitude is discussed.

Ku, W. H.-M.↗

A focusing gas scintillation proportional counter

An improved large-area gas scintillation proportional counter has been built, suitable for use in X-ray astronomy. This counter employs electron focusing in a drift region to achieve uniform response. It is shown that a window area of 60 sq cm and a spectral resolution of 10% fwhm or better at 5.9 keV can be obtained.

Anderson, D. F.↗

Prospects for high pressure imaging gas scintillation drift chambers

The current developmental status and future potential of a promising hard X-ray and gamma ray detector are presented: the high pressure xenon gas scintillation imaging drift chamber. A scheme for reading out the scintillation light waveshifting fibers, which allows operation at pressures at least as high as 20 atmospheres, is used. This technique combines excellent spatial resolution (approximately 200 rms allowing 1.5 arcminute mapping resolution), very good energy resolution (within a factor of three of Ge detectors), good time resolution (approximately 100 ns), and extremely high sensitivity because of excellent background rejection capabilities; it also offers possibilities for extrapolation to large area detectors. Results from tests with a prototype chamber are presented. The design of a scientific instrument for a balloon flight planned in 1995 is described. This instrument, the Scintillation Imaging Gas filled Hard X-ray Telescope (SIGHT), is optimized for detecting 30 to 300 keV X-rays. It has an active area of 1140 sq cm, with a stopping power of between 2.0 and 2.7 g/sq cm of xenon at 20 atmospheres. Possible future evolutionary tracks of the technology leading to innovative satellite applications are discussed.

Edberg, T. K.↗

A High-Energy Focal-Plane Gas Scintillation Proportional Counter

We have developed a high-pressure Gas Scintillation Proportional Counter (GSPC) for the focus of a hard-x-ray telescope. It features an absorption region 50 mm in diameter and 50 mm deep, filled with Xenon + 4% He at 10(exp 6) Pa total pressure, which gives useful response (greater than 75% efficiency) up to the mirror cut-off of 70 keV. Tests with a prototype unit show an energy resolution of 3.5% at 60 keV and a spatial resolution of 0.35 mm from 30-50 keV. Two flight units are currently under construction for a balloon flight in September 1999. Full details of their design and performance will be presented together with available quick-look background data from the flight.

Ramsey, B. D.↗

Recent developments in parallel-grid, gas-scintillation proportional counters

The problems of developing large-area, gas-scintillation proportional counters with high resolution are considered. It is found that simple large-area, parallel-grid proportional counters suffer from a variation in gain over the counter window. Some success has been achieved in overcoming this problem by focusing the charge cloud as it drifts into the multiplication region. Measurements are reported for various mixtures of argon and xenon as well as pure xenon.

Anderson, D. F.↗

A large-area gas scintillation proportional counter for X-ray astronomy

An improved large-area gas scintillation proportional counter has been built, suitable for use in X-ray astronomy. This counter employs electron focusing in a drift region to achieve uniform response. It is shown that a spectral resolution of 9.1% FWHM at 5.9 keV can be obtained over a useful area of 100 sq cm. It is demonstrated that signal rise-time discrimination can be used to reject non-X-ray background as efficiently as in ordinary proportional counters.

Anderson, D. F.↗

Gas scintillation drift chambers with wave shifter fiber readout

Results for a prototype xenon gas scintillation drift chamber are presented. Its operation is discussed using two types of light detection schemes: one based on an Anger camera geometry and one based on an array of wave-shifting light fibers. The results are judged to demonstrate the instrument's potential.

Sadoulet, Bernard↗

High pressure gas scintillation drift chambers with wave shifter fiber readout. I

The authors present results from a prototype xenon-gas scintillation drift chamber. It was operated at pressures up to 20 atm, and the scintillation light yield was measured at various pressures and reduced fields. Scintillation-reduced fields ranged from 1.3 to 3 kV/cm/atm in a 5.4-mm scintillation gap. Drift fields ranged from 45 to 100 V/cm/atm in an 8-cm drift region. The chamber was exposed to an 241Am source in a port either 2.7 or 5.4 cm from the secondary scintillation region. The authors also describe the high-voltage problems encountered during operation at high pressures. Further tests with the wave shifter fiber readout showed that the problem of gas contamination by the fibers is manageable but that the interaction between the optical fibers and the high-pressure xenon gas can lead to fiber damage. A solution to this problem is described.

Parsons, A.↗

High pressure gas scintillation drift chambers with wave-shifter fiber readout. II

Results from a prototype high-pressure xenon gas scintillation drift chamber using a novel wave-shifter fiber readout scheme are presented. The primary scintillation light yield was measured to be one photon per 76 + or - 12 eV deposited energy. Initial results on the chamber are presented for two-interaction separation (less than 4 mm in the drift direction and about 7 mm orthogonal to the drift); for position resolution (less than 400 microns rms in the plane orthogonal to the drift direction); and for energy resolution (less than 6 percent FWHM at 122 keV).

Parsons, A.↗

Gas Scintillation Proportional Counters for High-Energy X-ray Astronomy

A focal plane array of high-pressure gas scintillation proportional counters (GSPC) for a balloon-borne hard-x-ray telescope is under development at the Marshall Space Flight Center. These detectors have an active area of approx. 20 sq cm, and are filled with a high pressure (10(exp 6) Pa) xenon-helium mixture. Imaging is via crossed-grid position-sensitive phototubes sensitive in the UV region. The performance of the GSPC is well matched to that of the telescopes x-ray optics which have response to 75 keV and a focal spot size of approx. 500 microns. The detector s energy resolution, 4% FWHM at 60 keV, is adequate for resolving the broad spectral lines of astrophysical importance and for accurate continuum measurements. Full details of the instrument and its performance will be provided.

Gubarev, Mikhail↗

A High-Pressure Gas-Scintillation-Proportional Counter for the Focus of a Hard-X-Ray Telescope

We are developing a high-pressure Gas Scintillation Proportional Counter (GSPC) for the focus of a balloon-borne hard-x-ray telescope. The device has a total active diameter of 50 mm, of which the central 20 mm only is used, and is filled with xenon + 4% helium at a total pressure of 10 6 Pa giving a quantum efficiency of greater than 85% up to 60 keV. The detector entrance is sealed with a beryllium window, 3-mm thick, which provides useful transmission down to 6 keV, way below the atmospheric cut-off at balloon float altitudes. Scintillation light exits the detector via a UV transmitting window in its base and is registered by a Hamamatsu position-sensitive crossed-grid-readout photomultiplier tube. Initial testing is underway, quantifying light yield and energy resolution. Following that, the spatial resolution and absolute efficiency will be calibrated. Simulations show that a spatial resolution of better than 0.5 mm FWHM should be achievable up to 60 keV, and this is well matched to the angular resolution and plate scale of the mirror system. The energy resolution will be around 5% at 22 keV. Full details of the instrument design and its performance will be presented. A first flight is scheduled for the Fall of 99, on a stratospheric balloon to be launched from Fort Sumner, New Mexico.

Austin, R. A.↗

Performance of Gas Scintillation Proportional Counter Array for High-Energy X-Ray Observatory

A focal plane array of high-pressure gas scintillation proportional counters (GSPC) for a High Energy X-Ray Observatory (HERO) is developed at the Marshall Space Flight Center. The array is consisted from eight GSPCs and is a part of balloon born payload scheduled to flight in May 2004. These detectors have an active area of approximately 20 square centimeters, and are filled with a high pressure (10(exp 6) Pa) xenon-helium mixture. Imaging is via crossed-grid position-sensitive phototubes sensitive in the UV region. The performance of the GSPC is well matched to that of the telescopes x-ray optics which have response to 75 keV and a focal spot size of approximately 500 microns. The detector's energy resolution, 4% FWHM at 60 keV, is adequate for resolving the broad spectral lines of astrophysical importance and for accurate continuum measurements. Results of the on-earth detector calibration will be presented and in-flight detector performance will be provided, as available.

Gubarev, Mikhail↗

A high resolution gas scintillation proportional counter for studying low energy cosmic X-ray sources

In recent years much effort has been devoted to the development of large area gas scintillation proportional counters (GSPCs) suitable for use in X-ray astronomy. The paper deals with a low-energy GSPC for use in detecting sub-keV X-rays from cosmic sources. This instrument has a measured energy resolution of 85 eV (FWHM) at 149 eV over a sensitive area of 5 sq cm. The development of imaging capability for this instrument is discussed. Tests are performed on the feasibility of using an arrangement of several phototubes placed adjacent to one another to determine event locations in a large flat counter. A simple prototype has been constructed and successfully operated.

Hamilton, T. T.↗

Gas scintillation drift chambers with wave shifter read-out for hard X-ray astronomy

A major improvement in hard X-ray and gamma ray astrophysics could be provided by high pressure xenon time projection chambers where gas scintillation is used both for the measurement of the time of interaction and for the detection of the extracted electrons. This allows three dimensional imaging of naturally complex events (photoelectric interaction with escape photon, Compton scatter, and pair production). A novel read-out system based on wave shifter fibers, which is well suited to the high pressures and large areas required of a hard X-ray telescope is proposed. Expected performances are computed, potential problems are outlined, and the experimental effort to solve these problems are described.

Sadoulet, Bernard↗