Data-Driven Geometric Efficiency Correction for DUNE-PRISM Analysis
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Single crystal Diamond Detectors (SDD) are being increasingly exploited for neutron diagnostics in high power fusion devices, given their significant radiation hardness and high energy resolution capabilities. The geometrical efficiency of SDDs is limited by the size of commercially available crystals, which is often smaller than the dimension of neutron beams along collimated lines of sight in tokamak devices. In this work, we present the design and fabrication of a 14 MeV neutron spectrometer consisting of 12 diamond pixels arranged in a matrix, so to achieve an improved geometrical efficiency. Each pixel is equipped with an independent high voltage supply and read-out electronics optimized to combine high energy resolution and fast signals (<30 ns), which are essential to enable high counting rate (>1 MHz) spectroscopy. The response function of a prototype SDD to 14 MeV neutrons has been measured at the Frascati Neutron Generator by observation of the 8.3 MeV peak from the {sup 12}C(n, α){sup 9}Be reaction occurring between neutrons and {sup 12}C nuclei in the detector. The measured energy resolution (2.5% FWHM) meets the requirements for neutron spectroscopy applications in deuterium-tritium plasmas.
Abstract not provided.
It is proven that the solid angle (or geometry factor, also called the geometrical efficiency) for a spherically symmetric outward-directed surface source with an arbitrary radius and polar angle distribution and an arbitrary detector aperture is equal to the solid angle for an isotropic point source located at the center of the spherical surface source and the same detector aperture.
As an approximate theory that is highly regarded for its computational efficiency, geometrical optics (GO) is widely used for modeling waves in various areas of physics. However, GO fails at caustics, which significantly limits its applicability. A new framework, called metaplectic geometrical optics (MGO), has recently been developed that allows caustics of certain types to be modeled accurately within the GO framework. Here, we extend MGO to the most general case. Further, to illustrate our new theory, we also apply it to several sample problems, including calculations of two-dimensional wavefields near fold and cusp caustics. In contrast with traditional GO solutions, the corresponding MGO solutions are finite everywhere and approximate the true wavefield well near these caustics.
The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.
Thermal energy storage (TES) using phase change materials (PCMs) is a promising technology for capturing and storing excess thermal energy for later use. However, challenges such as poor heat transfer efficiency and a lack of modular, scalable designs have limited widespread adoption of TES in real-world applications. This study developed and evaluated modular brick-type and blade-type TES prototypes featuring an aluminum housing, an embedded serpentine coil for active or passive thermal exchange, and a cost-effective metal mesh to enhance PCM thermal conductivity. The blade-type TES achieved notable geometric efficiency, with a thickness-to-length ratio of 0.03 and a thickness-to-width ratio of 0.08, enabling highly compact and modular thermal storage suitable for space-constrained applications. The paper presents a detailed evaluation of the TES prototypes’ performance. The comparative analysis indicated that the TES prototypes provide a highly cost-effective, thermally optimized alternative for compact energy storage and load shifting. A novel diagnostic technique was also introduced: using a portable endoscope to capture real-time visualizations of PCM phase transitions inside the TES. This method provides critical insights into internal heat transfer mechanisms, identifies potential issues, and offers valuable support for optimizing the TES design and developing the control algorithm. Overall, the modular brick-type and blade-type TES designs demonstrated in this work provide a scalable, efficient, and economically viable solution for advancing TES across residential, commercial, and industrial sectors. The designs’ compact structure, enhanced thermal performance, and integrated diagnostic capabilities make them strong candidates for future deployment in energy-efficient systems.
It has previously been proven that the solid angle (or geometry factor, also called the geometrical efficiency) for a spherically symmetric outward-directed surface source with an arbitrary radius and polar angle distribution and an arbitrary detector aperture is equal to the solid angle for an isotropic point source located at the center of the spherical surface source and the same detector aperture. The solid angle for a source-detector system is the fraction of source particles that enter the detector aperture and so it is not purely geometric-the angular distribution of the source is a factor. The previous proof relied on an analytic transport-theory (streaming only) calculation of the solid angle Ω for a spherically symmetric surface source and a point detector. In this paper, a new, more elegant proof is given. Since the net current across any portion of a plane that intersects the center of a spherical surface source is zero, the solid angle for a spherical surface source with any polar angle distribution and a uniform azimuthal angle distribution and any detector aperture is equal to the solid angle for an isotropic point source and the same detector. This insight obviates the calculus and trigonometry involved in the previous proof. (author)
β-delayed charged-particle emission is a sensitive probe of three-body decays in light nuclei. Time Projection Chambers (TPCs) offer a significant advantage over traditional charged-particle spectroscopy techniques due to a low-energy threshold and a high-geometric efficiency (≈ 4π) which are essential for use with radioactive ion beams where the beam intensities are limited. The technique for high-sensitivity spectroscopy of β-delayed charged-particle emission is shown to be possible using the Texas Active Target (TexAT) TPC in conjunction with the General Electronics for TPCs (GET) system. The benchmark case studied was that of 12 N β-decay to the first α-unbound state in 12 C, the Hoyle state. Here, half-life and branching ratio measurements are presented and are in good agreement with previous studies. The efficacy of using TPCs to study such a near-threshold state and disentangle the three-body dynamics of the decay products is demonstrated.
Light sheet microscopy is a powerful technique for high-speed three-dimensional imaging of subcellular dynamics and large biological specimens. However, it often generates datasets ranging from hundreds of gigabytes to petabytes in size for a single experiment. Conventional computational tools process such images far slower than the time to acquire them and often fail outright due to memory limitations. To address these challenges, we present PetaKit5D, a scalable software solution for efficient petabyte-scale light sheet image processing. This software incorporates a suite of commonly used processing tools that are optimized for memory and performance. Notable advancements include rapid image readers and writers, fast and memory-efficient geometric transformations, high-performance Richardson–Lucy deconvolution and scalable Zarr-based stitching. These features outperform state-of-the-art methods by over one order of magnitude, enabling the processing of petabyte-scale image data at the full teravoxel rates of modern imaging cameras. The software opens new avenues for biological discoveries through large-scale imaging experiments.
In indirect drive inertial confinement fusion (ICF), laser induced Hohlraum preheat radiation (so-called M-band, >1.8 keV) asymmetry will lead to asymmetric ablation front and ablator–fuel interface hydrodynamic instability growth in an imploding capsule. First experiments to infer the M-band asymmetries at the capsule were performed on the National Ignition Facility for high density carbon (HDC) ICF capsules in low density fill (0.3 mg/cc 4 He) Au Hohlraums by time resolved imaging of 2.3 keV fluorescence emission of a smaller Mo sphere placed inside the capsule. In this study, the measured Mo emission is pole hot (P 2 > 0) since M-band is generated mainly by the outer laser beams as their irradiance at the Hohlraum wall is 5× higher than for the inner beams. P 2 has a greater negative than positive swing vs time [Δ(P 2 /P 0 )/Δt ~ 0.2/ns], giving insight into laser heated Hohlraum dynamics. P 4 asymmetry is small at the sphere due to efficient geometric smoothing of Hohlraum asymmetries at large Hohlraum -to-capsule ratios. The M-band P 2 history is qualitatively reproduced by radiation hydrodynamic HYDRA simulations. The smaller P 2 than that calculated earlier suggests either less outer beam spot motion and/or preheat emission. At late times, the observed P 2 swing is larger and P 4 is more negative than simulated, which could be due to inner beams being stopped more in the outer beams wall plasma bubble than simulated. Asymmetry at the HDC capsule inner surface (“ice–ablator interface”) is also inferred from the Mo emission asymmetry by an analytic viewfactor model, accounting for the Mo/HDC radius difference and HDC capsule opacity.
In inertial confinement fusion, penetrating asymmetric hohlraum preheat radiation (>1.8 keV, which includes high temperature coronal M-band emission from laser spots) can lead to asymmetric ablation front and ablator–fuel interface hydrodynamic instability growth in the imploding capsule. First experiments to infer the preheat asymmetries at the capsule were performed on the National Ignition Facility for high density carbon (HDC) capsules in low density fill (0.3 mg/cc 4He) Au hohlraums by time resolved imaging of 2.3 keV fluorescence emission of a smaller Mo sphere placed inside the capsule. Measured Mo emission is pole hot (P2 > 0) since M-band is generated mainly by the outer laser beams as their irradiance at the hohlraum wall is 5× higher than for the inner beams. P2 has a large swing vs time, giving insight into the laser heated hohlraum dynamics. P4 asymmetry is small at the sphere due to efficient geometric smoothing of hohlraum P4 asymmetries at large hohlraum-to-capsule radii ratios. The asymmetry at the HDC capsule is inferred from the Mo emission asymmetry accounting for the Mo/HDC radius difference and HDC capsule opacity.
Here, we report the first measurement of the fusion excitation functions for 39,47 K + 28 Si at near-barrier energies. Evaporation residues resulting from the fusion process were identified by direct measurement of their energy and time-of-flight with high geometric efficiency. At the lowest incident energy, the cross section measured for the neutron-rich 47 K-induced reaction is ≈6 times larger than that of the β-stable system. This experimental approach, both in measurement and in analysis, demonstrates how to efficiently measure fusion with low-intensity re-accelerated radioactive beams, establishing the framework for future studies.
Dark-field X-ray microscopy (DFXM) is a novel diffraction-based imaging technique that non-destructively maps the local deformation from crystalline defects in bulk materials. While studies have demonstrated that DFXM can spatially map 3D defect geometries, it is still challenging to interpret DFXM images of the high-dislocation-density systems relevant to macroscopic crystal plasticity. This work develops a scalable forward model to calculate virtual DFXM images for complex discrete dislocation structure(s) (DDS) obtained from atomistic simulations. Our new DDS-DFXM model integrates a non-singular formulation for calculating the local strain from the DDS and an efficient geometrical optics algorithm for computing the DFXM image from the strain field. We apply the model to complex DDS obtained from a large-scale molecular dynamics simulation of compressive loading on single-crystal silicon. Simulated DFXM images exhibit prominent contrast for dislocation features between the multiple slip systems, demonstrating the potential of DFXM to resolve features from dislocation multiplication. In conclusion, the integrated DDS-DFXM model provides a toolbox for DFXM experimental design and image interpretation in the context of bulk crystal plasticity for a range of measurements across shock plasticity and the broader materials science community.
The scintillator Cs 2 LiYCl 6 (CLYC) has emerged as a versatile detector for both gammas and neutrons, with excellent pulse shape discrimination. Originally developed as a thermal neutron counter, the discovery of its unexpected and unprecedented ~10% pulse height resolution for fast neutrons in the few MeV range has prompted studies to benchmark its use in low-energy nuclear science and applications. Since the typical long time-of-flight arms are not needed for achieving good energy resolution, geometrical efficiency can be enhanced by positioning the detectors much closer to the target. We have constructed a 16-element array of 1” × 1”7Li-enriched C 7 LYC, to eliminate the dominant peak in the spectrum from thermal neutron capture on 6Li, leaving the energy region above 3 MeV with a clean baseline for fast neutron spectroscopy. We have also procured the first ever 3” × 3” C 7 LYC crystal. Test experiments under way with C 7 LYC include elastic and inelastic neutron scattering cross sections at Los Alamos with a pulsed white neutron source, efficiency measurements using mono-energetic neutron beams up to a few MeV at UMass Lowell, and fission neutron measurements with GRETINA and CHICO detector arrays at Argonne. Beta-delayed neutron spectroscopy experiments have also been initiated at the CARIBU and NSCL facilities, to evaluate C 7 LYC as a possible candidate for auxiliary scintillator arrays for stopped beam physics at the next generation rare isotope accelerators.
We relax the cores of $\langle c+a \rangle$ edge and screw dislocations, and $(10\overline{1}2)$ and $(10\overline{1}1)$ twinning dislocations in Mg using first-principles calculations with flexible boundary conditions (FBC). FBC couple highly distorted cores to a harmonic lattice through lattice Green functions (LGF), allowing dislocations to relax as isolated defects. Unlike previous FBC calculations using bulk LGFs, we use LGFs specifically for dislocated geometries. The optimized geometries provide sites for computing solute-dislocation interactions via direct substitution, as well as local strain and slip for input to computationally efficient geometric solute interaction models. The interactions are inputs for solid-solution strengthening models. We compute interactions between Al, Ca, Mn, Sn, and Zn and the dislocations, and predict corresponding changes in stress for dislocation motion. We compare the strengthening of each of these non-basal deformation modes to basal strengthening and examine implications for ductility in Mg alloys. Funding from DOE-USAMP Cooperative Agreement Number DE-EE0007756.
In radioactive waste assay with gamma-ray computed tomography, calibration for intrinsic efficiency of the system is important to the reconstruction of radioactivity distribution. Due to the geometric characteristics of the system, the non-uniformity of intrinsic efficiency for gamma-rays with different incident positions and directions are often un-negligible. Intrinsic efficiency curves versus geometric parameters of incident gamma-ray are obtained by Monte-Carlo simulation, and two intrinsic efficiency models are suggested to characterize the intrinsic efficiency determined by relative source-detector position and system geometry in the system matrix. Monte-Carlo simulation is performed to compare the different intrinsic efficiency models. Better reconstruction results of radioactivity distribution are achieved by both suggested models than by the uniform intrinsic efficiency model. And compared to model based on detector position, model based on point response increases reconstruction accuracy as well as complexity and time of calculation. (authors)
Purpose: To propose, verify, and implement a simple and efficient methodology for the improvement of total geometric accuracy in multiple brain metastases gamma knife (GK) radiation surgery. Methods and Materials: The proposed methodology exploits the directional dependence of magnetic resonance imaging (MRI)-related spatial distortions stemming from background field inhomogeneities, also known as sequence-dependent distortions, with respect to the read-gradient polarity during MRI acquisition. First, an extra MRI pulse sequence is acquired with the same imaging parameters as those used for routine patient imaging, aside from a reversal in the read-gradient polarity. Then, “average” image data are compounded from data acquired from the 2 MRI sequences and are used for treatment planning purposes. The method was applied and verified in a polymer gel phantom irradiated with multiple shots in an extended region of the GK stereotactic space. Its clinical impact in dose delivery accuracy was assessed in 15 patients with a total of 96 relatively small (<2 cm) metastases treated with GK radiation surgery. Results: Phantom study results showed that use of average MR images eliminates the effect of sequence-dependent distortions, leading to a total spatial uncertainty of less than 0.3 mm, attributed mainly to gradient nonlinearities. In brain metastases patients, non-eliminated sequence-dependent distortions lead to target localization uncertainties of up to 1.3 mm (mean: 0.51 ± 0.37 mm) with respect to the corresponding target locations in the “average” MRI series. Due to these uncertainties, a considerable underdosage (5%-32% of the prescription dose) was found in 33% of the studied targets. Conclusions: The proposed methodology is simple and straightforward in its implementation. Regarding multiple brain metastases applications, the suggested approach may substantially improve total GK dose delivery accuracy in smaller, outlying targets.