Search NASA⌕ Search

SEARCH · Search NASA

Results for “grab sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Measurements of concentrations of chlorofluoromethanes (CFMs) carbon dioxide and carbon isotope ratio in stratospheric and tropospheric air by grab-sampling systems

Measurements of concentrations of chlorofluoromethanes (CFMs), carbon dioxide and carbon isotope ratio in stratospheric and tropospheric air by grab-sampling systems are reported. The balloon-borne grab-sampling system has been launched from Sanriku Balloon Center three times since 1981. It consists of: (1) six sampling cylinders, (2) eight motor driven values, (3) control and monitor circuits, and (4) pressurized housing. Particular consideration is paid to the problem of contamination. Strict requirements are placed on the choice of materials and components, construction methods, cleaning techniques, vacuum integrity, and sampling procedures. An aluminum pressurized housing and a 4-m long inlet line are employed to prevent the sampling air from contamination by outgassing of sampling and control devices. The sampling is performed during the descent of the system. Vertical profiles of mixing ratios of CF2Cl2, CFCl3 and CH4 are given. Mixing ratios of CF2Cl2 and CFCl3 in the stratosphere do not show the discernible effect of the increase of those in the ground level background, and decrease with altitude. Decreasing rate of CFCl3 is larger than that of CF2Cl2. CH4 mixing ratio, on the other hand, shows diffusive equilibrium, as the photodissociation cross section of CH4 is small and concentrations of OH radical and 0(sup I D) are low.

Itoh, T.↗

Evaluation of the Air Quality Monitor's Performance on the International Space Station

The Air Quality Monitor (AQM) was flown to the International Space Station (ISS) as an experiment to evaluate its potential to replace the aging Volatile Organic Analyzer (VOA), which ceased operations in August 2009. The AQM (Figure 1) is a small gas chromatography/differential mobility spectrometer (GC/DMS) manufactured by Sionex. Data was presented at last year s ISIMS conference that detailed the preparation of the AQM for flight, including instrument calibration. Furthermore, initial AQM data was compared to VOA results from simultaneous runs of the two instruments. Although comparison with VOA data provided a measure of confidence in the AQM performance, it is the comparison with results from simultaneously acquired air samples (grab sample containers-GSCs) that will define the success (or failure) of the AQM performance. This paper will update the progress in the AQM investigation by comparing AQM data to results from the analyses of GSC samples, returned from ISS. Additionally, a couple of example will illustrate the AQM s ability to detect disruptions in the spacecraft s air quality. Discussion will also focus upon a few unexpected issues that have arisen and how these will be a addressed in the final operational unit now being built.

Limero, Thomas↗

Apollo Saturn 511 effluent measurements from the Apollo 16 launch operations: An experiment

An experiment was performed in conjunction with the Apollo 16 launch to define operational and instrumentational problems associated with launch-vehicle exhaust effluent monitoring. Ground and airborne sampling were performed for CO, CO2, hydrocarbons, and particulates. Sampling systems included filter pads and photometers for particulates and whole-air grab samples for gases. Launch debris was identified in the particulate samples at ground level(taken immediately after launch) and in the airborne measurements (taken 40 to 50 minutes after launch approximately 40 km downwind of the pad). Operational problems were identified and included the need for higher instrumentation mobility and the need for real-time sampling instrumentation as opposed to collection-type samples such as the whole-air grab sample.

Gregory, G. L.↗

Space X1 First Entry Sample

One mini-grab sample container (m-GSC) was returned aboard Space X1 because of the importance of quickly knowing first-entry conditions in this new commercial module. This sample was analyzed alongside samples of the portable clean room (PCR) used in the Space X complex at KSC. The recoveries of C-13-acetone, fluorobenzene, and chlorobenzene from the GSCs averaged 130, 129, and 132 %, respectively.

James, John T.↗

Toxicological Assessment of ISS Air Quality: Contingency Sampling - February 2013

Two grab sample containers (GSCs) were collected by crew members onboard ISS in response to a vinegar-like odor in the US Lab. On February 5, the first sample was collected approximately 1 hour after the odor was noted by the crew in the forward portion of the Lab. The second sample was collected on February 22 when a similar odor was noted and localized to the end ports of the microgravity science glovebox (MSG). The crewmember removed a glove from the MSG and collected the GSC inside the glovebox volume. Both samples were returned on SpaceX-2 for ground analysis.

Meyers, Valerie↗

Day and night profiles of tropospheric nitrous oxide

Daytime and nighttime vertical profiles of the tropospheric trace gas N2O were determined from grab sample collections off the Atlantic and Gulf coasts of Florida. The grab samples were collected during the week of October 7-13, 1984, from a Lear jet during descent spirals over an altitude range of 12.5-0.3 km in approximately 1.2-km intervals. During this period there were two distinct airflow regimes sampled: (1) the surface boundary layer (less than 2 km), in which the wind direction was typically easterly; and (2) the regime above the boundary layer, which was predominantly characterized by westerly flow. N2O mixing ratios, normalized to dry air, were determined from 148 daytime and nighttime samplings. N2O was found to be uniformly mixed at all altitudes at 301.9 + or - 2.4 parts per billion by volume.

Cofer, Wesley R., III↗

Volatile Organic Analyzer (VOA) in 2006: Repair, Revalidation, and Restart of Elektron Event

The Volatile Organic Analyzer (VOA) was launched to the International Space Station (ISS) in August 2001 and was the first instrument to provide near real-time measurement of volatile organic compounds in a spacecraft atmosphere. The VOA performed an analysis of the ISS air approximately twice a month for most of its operation through May 2003. This intermittent operation, caused by a software interface issue with the ISS communication bus, slowed the validation of the VOA. However, operational validation was completed in 2003 when analysis of air samples collected in grab sample containers (GSCs) compared favorably with simultaneous VOA runs (1). The VOA has two channels that provide redundant function, albeit at slightly reduced performance, when only one channel is operating (2). Most target compounds can be detected on both channels. In January 2003, the VOA identified a malfunction in the channel 2 preconcentrator and it shut down that channel. The anomaly profile suggested that a fuse might have failed, but the root cause could not be determined. In May 2003, channel 1 was shut down when the detector s elevated temperature could not longer be maintained. Since both VOA channels were now deactivated, VOA operations ended until an in-flight repair could be planned and executed. This paper describes the process to repair the VOA and to revalidate it for operations, and then an account is given of the VOA s contribution following a contingency event on ISS.

Limero, Thomas↗

Measurements of the global distribution of carbon monoxide in the troposphere

Carbon monoxide and methane grab samples were obtained simultaneously with ozone, aerosol, nitric oxide and DACOM CO measurements. Eighty grab samples were collected at various altitudes up to 19,000 ft. along a north-south flight path from Wallops Flight Center, VA to 11 N. CO and CH were analyzed by flame ionization gas chromatography with cryogenic preconcentration. The relationship between CO and O3 concentrated is examined. A comparative analysis between trends in aerosol and CO concentration is performed.

Hinton, R. R.↗

Luna 24: 90-150 micrometer fraction - Implications for remote sampling of regolith

An analysis of the mineral grains and glasses found in the 90 to 150 micron fraction of the Luna 24 core sample is presented and implications for the automatic collection of planetary and asteroidal regoliths are discussed. Electron microprobe analysis for pyroxene, olivine, plagioclase, opaque minerals and glass in samples at various depths indicate that polymineralic grains have compositions similar to those of gabbroic and basaltic fragments from coarser samples, while monomineralic grains contain an additional population of Mg-rich olivines and pyroxene. Most of the glasses are found to be related to mare basalts or local regolith, with nonmare material represented by glasses of highland basalt and low K Fra Mauro composition. It is concluded that as regards mineralogy and petrology, a single grab sample would have been as useful and a series of grab samples on a long traverse would have been more useful than the Luna 24 core sample, with the fine sample being more informative than the coarse.

Papp, H. A.↗

Stratospheric CCN sampling program

Two one liter grab samples of stratospheric aerosol were returned from each of six U-2 sampling missions. Cloud condensation nuclei (CCN) spectra from each sample were obtained. Interest was centered on the effects of volcanic activity. Spurious particle generation was found to be a serious problem in container 9 LFT and a much smaller problem in container 9 RT. Initial studies of an option for improved sample containers and values were completed. A CCN spectrometer, able to operate at an internal pressure of 300 mb, was designed.

Rogers, C. F.↗

Soyuz 24 Return Samples: Assessment of Air Quality Aboard the International Space Station

Fifteen mini-grab sample containers (m-GSCs) were returned aboard Soyuz. This is the first time all samples were acquired with the mini-grab samplers. The toxicological assessment of 15 m-GSCs from the ISS is shown. The recoveries of the 3 internal standards, C(13)-acetone, fluorobenzene, and chlorobenzene, from the GSCs averaged 75, 97 and 79%, respectively. Formaldehyde badges were not returned on Soyuz 24

James, John T.↗

STS 125 Samples: the Hubble Servicing Mission

The toxicological assessments of 2 grab sample canisters (GSCs) from the Shuttle are reported in a table. Based on the end-of-mission sample, the Shuttle atmosphere was acceptable for human respiration.

James, John T.↗

Soyuz 22 Return Samples: Assessment of Air Quality Aboard the International Space Station

Three mini-grab sample containers (m-GSCs) were returned aboard Soyuz 22 because of concerns that new air pollutants were present in the air and these were getting into the water recovery system. The Total Organic Carbon Analyzer had been giving increasing readings of total organic carbon (TOC) in the potable water, and it was postulated that an increased load into the system was responsible. The toxicological assessment of 3 m-GSCs from the ISS is shown in Table 1. The recoveries of the 3 standards (as listed above) from the GSCs averaged 103, 95 and 76%, respectively. Recovery from formaldehyde control badges were 90 and 91%.

Jams, John T.↗

Soyuz 23 Return Samples: Assessment of Air Quality Aboard the International Space Station

Six mini-grab sample containers (m-GSCs) were returned aboard Soyuz 23 because of concerns that new air pollutants had been present in the air and these were getting into the water recovery system. The Total Organic Carbon Analyzer had been giving increasing readings of total organic carbon (TOC) in the potable water, and it was postulated that an increased load into the system was responsible. The TOC began to decline in late October, 2010. The toxicological assessment of 6 m-GSCs from the ISS is shown in Table 1. The recoveries of 13C-acetone, fluorobenzene, and chlorobenzene from the GSCs averaged 73, 82, and 59%, respectively. We are working to understand the sub-optimal recovery of chlorobenzene.

James, John T.↗

Assessment of Air Quality in the International Space Station (ISS) and Space Shuttle Based on Samples Returned Aboard STS-ll1 (UF2) in June 2002

The toxicological assessments of grab sample canisters (GSCs) and 2 solid sorbent air samplers (SSASs) returned aboard STS-111 are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the GSCs were 86-106% and 62% to 136 % from the SSASs; 2 tubes with low surrogate recoveries were not reported. Pressure tracking indicated no leaks in the canisters during analysis. Recoveries from lab and trip controls for formaldehyde analyses ranged from 87 to 96%. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). Because of the inertness of Freon 218 (octafluoropropane, OFP), Its contribution to the NMVOC is subtracted and tabulated separately. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols (including acetone) are also shown for each sample. Because formaldehyde is quantified from sorbent badges, its concentration is listed separately. The table shows that the air quality in general was acceptable for crew respiration; however, certain values shown in bold require further explanation. The 1.05 T value on 2/28/02 was caused by an unusually high measurement ofhexamethylcyc1otrisiloxane (T value = 0.50), which is not a concern. The MPLM T value of 1.42 and the alcohol level of 7.5 mg/cu m were due to an overall polluted atmosphere, which was expected at first entry. The major T-value component was carbon monoxide at a contribution of 0.44 units. Since the crew was only exposed momentarily to the polluted atmosphere, no health effects are expected. The formaldehyde value of 0.060 mg/cu m found in the Lab sample from 3/27/02 is cause for concern because the Lab consistently shows higher concentrations of formaldehyde than the SM and occasionally the concentrations are above the acceptable guideline. Levels of OFP have remained low, suggesting that no further leaks of the SM air conditioner have occurred.

James, John T.↗

Soyuz 7 Return Samples: Assessment of Air Quality Aboard the International Space Station

The toxicological assessments of one grab sample canister (GSC), 6 dual sorbent tubes (DSTs), and 20 formaldehyde badges returned aboard Soyuz 7 are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the GSC were 84-89%. The recoveries of the less volatile surrogates from the DSTs were 87 to 112%; however, 13C-acetone was only recovered at 53-59%. Formaldehyde recoveries from 2 lab controls were 87 and 95%; trip controls were not returned to ground.

James, John T.↗