Search NASA⌕ Search

SEARCH · Search NASA

Results for “grab sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Demonstration of VOC Fenceline Sensors and Canister Grab Sampling near Chemical Facilities in Louisville, Kentucky

Experimental fenceline sensor pods (SPods) fitted with 30 s duration canister grab sampling (CGS) systems were deployed at a site near chemical facilities in Louisville, KY, from 4 June 2018 to 5 January 2020. The objective of the study was to better understand lower cost 10.6 eV photoionization detector (PID)-based volatile organic compound (VOC) sensors and investigate their utility for near-source emissions detection applications. Prototype SPods containing PID sensor elements from two different manufacturers yielded between 78% and 86% valid data over the study, producing a dataset of over 120,000 collocated pair fenceline measurements averaged into 5-min datapoints. Ten-second time-resolved SPod data from an elevated fenceline sensor signal day are presented, illustrating source emission detections from the direction of a facility 500 m west of the monitoring site. An SPod-triggered CGS acquired in the emission plume on this day contained elevated concentrations of 1,3-butadiene and cyclohexane (36 parts per billion by volume (ppbv) and 637 ppbv, respectively), compounds known to be emitted by this facility. Elevated concentrations of these compounds were observed in a subset of the 61 manual and triggered CGS grab samples acquired during the study, with winds from the west. Using novel wind-resolved visualization and normalization approaches described herein, the collocated pair SPod datasets exhibited similarity in emission source signature. With winds from the west, approximately 50% of SPod readings were above our defined theoretical detection limit indicating persistent measurable VOC signal at this site. Overall, this 19-month study demonstrated reasonable prototype SPod operational performance indicating that improved commercial forms of lower cost PID sensors could be useful for select VOC fenceline monitoring applications.

1,3-butadiene↗

Applications of Hyporheic Zone Sampling for Assessing VOC Plume Engineered Remediation and Natural Attenuation Effectiveness - 20414

Determining the efficacy of engineered remedial actions and/or natural attenuation as an acceptable EPA Record of Decision (ROD) must address long-term temporal and spatial variability. Since final plume downslope destinations are aquifers and related surface streams and rivers, hyporheic zone sampling is essential. Comprehensive hyporheic sampling documents plume groundwater remediation prior to upwelling into stream benthic strata and natural attenuation within this dynamic zone itself. Our intensive sampling of the Savannah River Site (SRS) Chemical, Metals, and Pesticides (CMP) Pits VOC plume-fringe from 2005 to 2018 documented PCE natural attenuation and effectiveness of In Situ Thermal Treatment (ISTT). Most plume hyporheic upwelling was delimited to a 20 m inflow reach along Pen Branch. Our study utilized corroborative sampling methodologies: ambient hole-water grab samples: passive diffusion bags (PDB); and hole-core sediment samples to confirm station to station spatial and temporal trends. VOC hot spot detections were confirmed from both groundwater and soil core samples. VOC pathways through the Pen Branch hyporheic zone were assessed at hole-installation using sequential soil samples from augered cores and grab-samples of hole-bottom water. Longer term, composite water samples were collected from PDBs deployed for a minimum two-week equilibration period. Soil samples were collected from the 15 and 65 cm core levels in December 2017 and June 2018 at six stations. Additional core depths of 40 and 85 cm were sampled in June 2018 at the highest VOC station (5DB80). All samples were analyzed in an EPA certified lab by purge and trap GC-MS. Effectiveness of previous ISTT and soil vapor extraction (SVE) for this CMP Pits PCE plume, was clearly documented by significant downward trends in VOC at hyporheic zone stations prior to December 2015. Achieving final stage conversions of PCE daughter products to ethene and CO{sub 2} may be limited depending upon suitable interactions between hyporheic zone sediment morphology, hydrology, and redox conditions. Because declines in VOC daughter products at our hyporheic stations may also be caused by physical actions of dilution and dispersion rather than true biochemical dechlorination, full quantification of natural attenuation requires the use of compound-specific isotope ratio analysis (CSIA) and microbial 16S rRNA with qPCR. To assist these next-phase efforts, a natural attenuation index (NAI) was used to help produce quicker, more cost-effective decision making for locating CSIA and microbial sampling efforts. The NAI used natural logarithm transformed GC-MS results for station VOC degradation compounds versus VOC parent compounds. Wide differences were observed between stations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Post-fire time series of sensor and geochemistry sample data from surface water, groundwater, precipitation, soil, and vegetation across Oak Creek watershed, Washington

This dataset supports a broader study examining wildfire impacts on hydrologic connectivity across 5 sites within the Oak Creek watershed and the resulting biogeochemical impacts. Stream sites were selected using the Advanced Terrestrial Simulator (ATS) hydrologic model to identify locations with varying groundwater contributions and hydrologic responses across different burn severity scenarios. The Retreat Fire burned from July 23 to August 2 in 2024, affecting the five study sites at varying burn severities. Each site is equipped with YSI EXO2 sondes logging sub-hourly throughout the year, and grab samples are collected approximately every six weeks. YSI sondes are used to measure temporally resolved proxies for groundwater inputs (specific conductivity) and organic matter (fluorescent dissolved organic matter; fDOM) along with basic water quality and depth. Grab samples of surface water, groundwater, and precipitation are analyzed for water stable isotopes and conductivity to understand endmembers for hydrologic mixing Grab samples of surface water, groundwater, soil water, and litter/vegetation/soil leachates are analyzed for organic matter composition measured by Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry (FTICR-MS) to understand organic matter dynamics. Game camera photos are provided in a separate data package available at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/3018598. Future versions of this dataset will include time series data from YSI EXO2 sondes (fDOM, dissolved oxygen, temperature, depth, specific conductance, turbidity, pH), BaroTROLL sensors (air temperature and barometric pressure), rain gauges (precipitation), and data from the soil and vegetation samples. Because this study is ongoing, this data package will be updated regularly to include newly collected data and the additional data types. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset is comprised of (1) a folder of field photos; (2) a folder of surface water sample data; (3) a folder of raw Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) data; (4) a data checks report; (5) file-level metadata; (6) data dictionary; (7) field metadata; (8) readme; (9) international generic sample number (IGSN) mapping file; and (10) field protocols. The sample data subfolder contains (1) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data and averages; (2) total dissolved nitrogen data and averages; (3) stable water isotopes and averages; (4) methods codes; (5) FTICR-MS methods; and (15) a subfolder of 9.4 Tesla (9.4T) FTICR-MS data. This folder contains the processed data and three subfolders, one containing the .xml files, one containing the water CoreMS output files, and the other containing instructions and scripts for processing the files in CoreMS (https://github.com/EMSL-Computing/CoreMS). All files are .csv, .pdf, .R, .xml, .d, .html, .Rmd, .py, .cal, .json, .jpg, .jpeg, .png, .mov, or .mp4.

Biogeochemistry↗

Greenhouse production contributes to pesticide occurrences in Swedish streams

Greenhouse and other covered cultivation systems have increased globally over the past several decades, leading to considerably improved product quality and productivity per land area unit. However, there is a paucity in information regarding the environmental impacts of covered production systems, especially regarding pesticides entering the surrounding environment. Aiming to address this knowledge gap, we collected grab samples downstream of greenhouses from seven Swedish streams every 14 days during a 12 month period. In three of the streams, samples were also taken upstream of the greenhouses and in four of the streams time-integrated samples were collected by TIMFIE samplers in the period between grab sampling occasions. The samples were analyzed for 28 substances (27 that were permitted for use in greenhouse production systems in Sweden and one degradation product to a permitted substance). Pesticide use journals were collected from the greenhouse producers for the 12 month period. The results were examined for indications of greenhouse contributions to detection frequencies, maximum and average concentrations, and potential ecotoxicicity in several ways: (1) comparing locations downstream of greenhouses with registered use of a substance with those without registered use, (2) comparing results from this study with those from the Swedish environmental monitoring program of pesticides in surface water from catchments with no greenhouses from the same period and region, (3) comparing concentration trends with registered pesticide application times in the greenhouses, and (4) comparing up- and downstream concentrations. The results strongly suggest that greenhouse applications do contribute to pesticide occurrences, maximum and median concentrations for most of the pesticides included in this study, and to potential toxicity to aquatic organisms for several of them, most notably imidacloprid, acetamiprid, carbendazim, and pirimicarb.

54 ENVIRONMENTAL SCIENCES↗

Monthly Sewer Monitoring Report for LLNL Livermore Site, April 2020

Lawrence Livermore National Laboratory (LLNL) collects effluent samples from its sewer outfall at the B196 Sewer Monitoring Station (SMS). Effluent flow-proportional composite samples are collected at the SMS on a daily (midnight-to-midnight), weekly (Thursday through Wednesday), and “monthly” (composited from daily) basis; effluent grab samples are also collected each month at that same location. Certified contract laboratories analyzes these compliance samples, and results (Tables 1–3) are used to establish LLNL compliance with the 2019–2020 Wastewater Discharge Permit (Permit 1250) granted by the City of Livermore Water Resources Division (WRD). Supplemental analyses for biochemical oxygen demand (BOD) and total suspended solids (TSS) are performed onsite and reported (Table 4) for the calculation and assessment of sewer service charges. Quarterly, effluent is sampled for metals (24-hour composite) and cyanide (grab sample) concentrations (mg/L). The results are presented in Table 5. In addition to the sampling noted above, the SMS continuously monitors LLNL sewage effluent in real-time for flow rate, pH, metals, and radioactivity. Standard measurement methods are used to monitor flow and pH to determine permit compliance. Unique nonstandard analytical methods monitor for the presence of metals and radioactivity using x-ray fluorescence (XRF) and gamma spectroscopy, respectively. If an anomalous condition is detected by the monitoring system, an alarm activates LLNL’s Sewer Diversion Facility (SDF) and Livermore Water Reclamation Plant (LWRP) operators are notified that a potential release has occurred.

54 ENVIRONMENTAL SCIENCES↗

Monthly Sewer Monitoring Report for LLNL Livermore Site (Jun 2020)

Lawrence Livermore National Laboratory (LLNL) collects effluent samples from its sewer outfall at the B196 Sewer Monitoring Station (SMS). Effluent flow-proportional composite samples are collected at the SMS on a daily (midnight-to-midnight), weekly (Thursday through Wednesday), and “monthly” (composited from daily) basis; effluent grab samples are also collected each month at that same location. Certified contract laboratories analyze these compliance samples, and results are used to establish LLNL compliance with the 2019 - 2020 Wastewater Discharge Permit (Permit 1250) granted by the City of Livermore Water Resources Division (WRD). Supplemental analyses for biochemical oxygen demand (BOD) and total suspended solids (TSS) are performed onsite and reported for the calculation and assessment of sewer service charges. Quarterly, effluent is sampled for metals (24-hour composite) and cyanide (grab sample) concentrations (mg/L).

54 ENVIRONMENTAL SCIENCES↗

Evaluating Manual Sampling Locations for Regulatory and Emergency Response

Drinking water systems commonly use manual or grab sampling to monitor water quality, identify or confirm issues, and verify that corrective or emergency response actions have been effective. In this paper, the effectiveness of regulatory sampling locations for emergency response is explored. An optimization formulation based on the literature was used to identify manual sampling locations to maximize overall nodal coverage of the system. Results showed that sampling locations could be effective in confirming incidents for which they were not designed. When evaluating sampling locations optimized for emergency response against regulatory scenarios, the average performance was reduced by 3%–4%, while using optimized regulatory sampling locations for emergency response reduced performance by 7%–10%. Secondary constraints were also included in the formulation to ensure geographical and water age diversity with minimal impact on the performance. This work highlighted that regulatory sampling locations provide value in responding to an emergency for these networks.

54 ENVIRONMENTAL SCIENCES↗

High Frequency Monitoring and Nitrate Sourcing Reveals Baseflow and Stormflow Controls on Total Dissolved Nitrogen and Carbon Export Along a Rural‐Urban Gradient

Abstract Efforts to reduce nitrogen and carbon loading from developed watersheds typically target specific flows or sources, but across gradients in development intensity there is no consensus on the contribution of different flows to total loading or sources of nitrogen export. This information is vital to optimize management strategies leveraging source reductions, stormwater controls, and restorations. We investigate how solute loading and sources vary across flows and land‐use using high frequency monitoring and stable nitrate isotope analysis from five catchments with different sanitary infrastructure, along a gradient in development intensity. High frequency monitoring allowed estimation of annual loading and attribution to storm versus baseflows. Nitrate loads were 16 kg/km 2 /yr. from the forested catchment and ranged from 68 to 119 kg/km 2 /yr., across developed catchments, highest for the septic served site. Across developed catchments, baseflow contributions ranged from 40% of N loading to 75% from the septic served catchment, and the contribution from high stormflows increased with development intensity. Stormflows mobilized and mixed many surface and subsurface nitrate sources while baseflow nitrate was dominated by fewer sources which varied by catchment (soil, wastewater, or fertilizer). To help inform future sampling designs, we demonstrate that grab sampling and targeted storm sampling would likely fail to accurately predict annual loadings within the study period. The dominant baseflow loads and subsurface stormflows are not treated by surface water management practices primarily targeted to surface stormflows. Using a balance of green and gray infrastructure and stream/riparian restoration may target specific flow paths and improve management.

Delesantro, Joseph M.↗

Atmospheric H 2 observations from the NOAA Cooperative Global Air Sampling Network

Abstract. The NOAA Global Monitoring Laboratory (GML) measures atmospheric hydrogen (H2) in grab samples collected weekly as flask pairs at over 50 sites in the Cooperative Global Air Sampling Network. Measurements representative of background air sampling show higher H2 in recent years at all latitudes. The marine boundary layer (MBL) global mean H2 was 552.8 ppb in 2021, 20.2 ± 0.2 ppb higher compared to 2010. A 10 ppb or more increase over the 2010–2021 average annual cycle was detected in 2016 for MBL zonal means in the tropics and in the Southern Hemisphere. Carbon monoxide measurements in the same-air samples suggest large biomass burning events in different regions likely contributed to the observed interannual variability at different latitudes. The NOAA H2 measurements from 2009 to 2021 are now based on the World Meteorological Organization Global Atmospheric Watch (WMO GAW) H2 mole fraction calibration scale, developed and maintained by the Max Planck Institute for Biogeochemistry (MPI-BGC), Jena, Germany. GML maintains eight H2 primary calibration standards to propagate the WMO scale. These are gravimetric hydrogen-in-air mixtures in electropolished stainless steel cylinders (Essex Industries, St. Louis, MO), which are stable for H2. These mixtures were calibrated at the MPI-BGC, the WMO Central Calibration Laboratory (CCL) for H2, in late 2020 and span the range 250–700 ppb. We have used the CCL assignments to propagate the WMO H2 calibration scale to NOAA air measurements performed using gas chromatography and helium pulse discharge detector instruments since 2009. To propagate the scale, NOAA uses a hierarchy of secondary and tertiary standards, which consist of high-pressure whole-air mixtures in aluminum cylinders, calibrated against the primary and secondary standards, respectively. Hydrogen at the parts per billion level has a tendency to increase in aluminum cylinders over time. We fit the calibration histories of these standards with zero-, first-, or second-order polynomial functions of time and use the time-dependent mole fraction assignments on the WMO scale to reprocess all tank air and flask air H2 measurement records. The robustness of the scale propagation over multiple years is evaluated with the regular analysis of target air cylinders and with long-term same-air measurement comparison efforts with WMO GAW partner laboratories. Long-term calibrated, globally distributed, and freely accessible measurements of H2 and other gases and isotopes continue to be essential to track and interpret regional and global changes in the atmosphere composition. The adoption of the WMO H2 calibration scale and subsequent reprocessing of NOAA atmospheric data constitute a significant improvement in the NOAA H2 measurement records.

Pétron, Gabrielle↗

Analysis of microplastics in bivalves along Fourmile Branch

Microplastics are commonly found near wastewater treatment facilities with the source originating typically from fibers associated with laundry detergents. Fourmile branch would have limited laundry associated effluent and does not receive any input from water originating from upstream industry sources, therefore microplastics would have originated from Site operations or through atmospheric deposition which are both unexplored pathways. In order to assess environmental inventory effects on the biota, water samples were collected from sampling locations along Fourmile Branch on the Savannah River Site using plankton nets and grab samples at Fourmile Branch locations (i.e., FM-2B, FM-A7, and FM6). Fourmile Branch has a long history of receiving industrial effluents from site operations as well effluent from the site’s wastewater treatment plant. Water samples and the debris collected in the nets were rinsed with deionized water and sieved to remove the larger fractions of plastics (4000-2000 µm) and retain fractions <500 µm. The water samples were analyzed for the type and size of plastics by μ-Raman, mass spectrometry, and Fourier Transform Infrared Spectroscopy (FTIR) methods. Previously collected bivalves were prepared into thin sections and analyzed using microscopy.

54 ENVIRONMENTAL SCIENCES↗

2018 Meander C floodplain groundwater chemistry from the East River Watershed, Colorado

This dataset includes groundwater geochemistry data from floodplain piezometers collected as a part of the Watershed Function Scientific Focus Area (SFA) located in the Upper Colorado River Basin. The data were collected in order to investigate the role of hyporheic exchange and other river corridor processes on riverine export of solutes. Floodplain piezometers installed along two transects across Meander C in the Pumphouse vicinity (MCP and MCB wells) were sampled on daily to weekly time scales during summer-fall 2018. Some river water grab samples are also included. Data includes in-field measurements (pH, electrical conductivity [EC], oxidation reduction potential [ORP], dissolved oxygen [DO], Fe(II), and groundwater level) along with laboratory measurements (dissolved inorganic carbon [DIC], dissolved organic carbon [DOC], metals and major cations, anions [chloride, sulfate, nitrate], and dissolved ammonium). Five files are included in this dataset, including: sample locations and depths in both a kmz file which can be opened in Google Earth and a csv file, sampling protocol as a pdf document, aqueous geochemistry data in a csv file, and analytical detection limits in a csv file.

54 ENVIRONMENTAL SCIENCES↗

2018 Meander Y and Meander Z floodplain groundwater chemistry from the East River watershed, Colorado

This dataset includes groundwater geochemistry data from floodplain piezometers collected as a part of the Watershed Function Scientific Focus Area (SFA) located in the Upper Colorado River Basin. The data were collected in order to investigate the role of hyporheic exchange and other river corridor processes on riverine export of solutes. Floodplain piezometers installed in Meander Z (MZA, MZB wells) and Meander Y (MYP wells) just upstream of the confluence with Brush Creek were sampled on daily to weekly time scales during summer-fall 2018. Some river water grab samples are also included. Data includes in-field measurements (pH, electrical conductivity [EC], oxidation reduction potential [ORP], and groundwater level) along with laboratory measurements (dissolved inorganic carbon [DIC], dissolved organic carbon [DOC], metals and major cations, anions [chloride, sulfate, nitrate], and dissolved ammonium). Five files are included in this dataset, including: sample locations and depths in both a kmz file which can be opened in Google Earth and a csv file, sampling protocol as a pdf document, aqueous geochemistry data in a csv file, and analytical detection limits in a csv file.

54 ENVIRONMENTAL SCIENCES↗

2019 Meander C and Meander Z floodplain groundwater chemistry from the East River Watershed, CO, USA

This dataset includes groundwater geochemistry data from floodplain piezometers collected as a part of the Watershed Function Scientific Focus Area (SFA) located in the Upper Colorado River Basin. The data were collected in order to investigate the role of hyporheic exchange and other river corridor processes on riverine export of solutes. Data includes samples from two intra-meander zones: Meander C, in the Pumphouse vicinity, and Meander Z, just upstream of the confluence with Brush Creek. Floodplain piezometers installed along two transects across Meander C (MCP and MCB wells) and Meander Z (MZA and MZB wells) were sampled on daily to weekly time scales during summer-fall 2019. Some river water grab samples are also included. Data includes in-field measurements (pH, electrical conductivity [EC], oxidation reduction potential [ORP], dissolved oxygen [DO], and groundwater level) along with laboratory measurements (dissolved inorganic carbon [DIC], dissolved organic carbon [DOC], metals and major cations, anions [chloride, sulfate, nitrate], and dissolved ammonium). Files are included in this dataset include: sample locations and depths in both a kmz file which can be opened in Google Earth and a csv file, aqueous geochemistry data in a csv files for Meander C and Meander Z, and analytical detection limits in a csv file. This dataset also includes a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata and a data dictionary (dd.csv) file that contains column/row headers used throughout the files along with a definition, units, and data type.

54 ENVIRONMENTAL SCIENCES↗

Development and Demonstration of a Prototype Molten Salt Sampling System

Molten salt reactors (MSRs) offer potential operability and safety advantages when compared to commercial light water reactors (LWRs). However, operating experience with MSRs is sparse in comparison to what exists for LWRs. Further, the chemical and isotopic composition of the fuel and/or coolant salt is dynamic and difficult to characterize continuously, posing potential safety, operability, and safeguards unknowns that need to be addressed. A molten salt sampling system (MSSS) is regarded as a necessary subsystem within first generation MSRs used to obtain samples of salt for chemical and isotopic analysis in support of the need to monitor and control salt composition during operation. The MSSS is being developed using the Safety-in-Design (SiD) methodology, which incorporates incremental integration of safety analysis into the design process. The MSSS conceptual design emerging from the application of the early stages of the SiD methodology consists of a sample collection system and its housing, a freeze port, and inert gas control and delivery systems. This article describes the prototypes developed to test the functions of these MSSS subsystems, presents the results of testing in both dry and molten salt environments (including reliability data collection performed in accordance with the principles of SiD and the development of a semiquantitative fault tree model), and summarizes the opportunities for future design and testing enhancements based on the results of prototype testing.

molten salt reactor↗

Surface and Active Layer Water Chemistry, Teller Road Mile Marker 27, Seward Peninsula, Alaska, 2016-2018

This dataset provides the results of spatial surveys of aqueous geochemistry conducted at Teller Road Site, Seward Peninsula, Alaska. Surface water and soil pore water samples were collected from multiple depth within the active layer at designated Intensive Stations 2 through 9 at the Teller Road MM 27 Site (TL_MM27). Reported analytes include dissolved methane and carbon dioxide, dissolved organic and inorganic carbon, major inorganic anions, and major and minor cations. Samples and measurements were collected from 2016-2018. Specifically, samples were collected in September of 2016, August and September of 2017, and August of 2018. Most of the samples were collected from piezometers installed at various depths within the active layer (70 cm max). A few are surface water grab samples. Data are provided in a single comma separated (.xlsx / .csv) file. One supplemental file is also included. It provides the results of a limited set of analyses (dissolved methane and carbon dioxide and Fe(II)) on surface and soil pore water samples collected at Teller (TL_MM27) and Council (CN_MM71) locations in September 2019. The metadata and data are draft with outstanding clarifications and additions to come. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 10-year research effort (2012-2022) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy?s Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy?s Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Riverbed and Near-Surface Water Quality Data, Hanford Reach, Columbia River, February 2021 - April 2022

This dataset contains longitudinal profiles of natural groundwater tracers (temperature, electrical conductivity (EC), and Radon-222 (Rn)) collected to identify locations of hydrologic exchange flows along a 75-km reach of the Columbia River near Richland, Washington.A jetboat was used to tow a 30 foot long, weighted tether that had one set of temperature and EC sensors just below the water surface and one set of temperature and EC sensors on the end (just above the river bed). The dataset contains profiles of temperature/EC data (resolution: 1 second) collected along the left and right banks during three different sampling events. During the final sampling event, we revisited some "deep holes" where the river was more than 30 feet deep with a weighted tether that was 75 feet long. The dataset has been processed to remove data collected when the sensors were not in the water, or when the water was too deep to keep the tether on the riverbed. We collected grab samples of water for analysis of dissolved Rn in places where the temperature/EC was different from the background river water. The Rn data was joined to the temperature/EC profiles based on the sample times.This dataset is comprised of one main data folder containing (1) file-level metadata; (2) data dictionary; (3) installation methods; (4) February 2021 data; (5) July 2021 data; (6) April 2022 data; and (7) April 2022 deep hole data. All files are .csv format and can be opened with a spreadsheet program (such as Microsoft Excel or OpenOffice).

54 ENVIRONMENTAL SCIENCES↗

Application of On-Line Monitoring and Real-Time Characterization of Low Level Waste Samples from Hanford Tanks

Waste and treatment stream characterization is an essential part of safe, efficient, and cost-effective processing of Hanford materials. The demand for materials characterization, including chemical, radionuclide, and physical attributes during waste management, transfer, and staging operations in the Hanford tank farms, is expected to significantly increase as the U.S. Department of Energy Office of River Protection (ORP) progresses toward Hanford waste treatment and immobilization. The application of on-line monitoring can greatly improve operation timeframes and reduce costs by providing real-time data and supporting the reduction of necessary grab sample collection. Recently, our team applied Raman online monitoring and chemometric modeling to the supernate of Hanford tank 241-AP-105, and demonstrated the quantitative measurement of nine analytes within this waste. Application of this method has been expanded to additional Hanford tank wastes, AW-102 and AP-107. The performance of the process monitoring instruments and the accuracy of the chemometric models will be assessed. On-line monitoring results will be compared to anion results determined from the current standard, ion-chromatographic and inductively coupled plasma mass spectrometry methods. Comparisons of both determined values and uncertainties of results will be presented. Results will be shared with personnel working on flowsheet interfaces for the Direct-Feed Low Activity Waste mission at Hanford.

Lines, Amanda M.↗

Application of On-Line Monitoring and Real-Time Characterization of Low Level Waste Samples from Hanford Tanks - 20380

Waste and treatment stream characterization is an essential part of safe, efficient, and cost-effective processing of Hanford materials. The demand for materials characterization, including chemical, radionuclide, and physical attributes during waste management, transfer, and staging operations in the Hanford tank farms, is expected to significantly increase as the U.S. Department of Energy Office of River Protection (ORP) progresses toward Hanford waste treatment and immobilization. The application of on-line monitoring can greatly improve operation time frames and reduce costs by providing real-time data and supporting the reduction of necessary grab sample collection. Recently, our team applied Raman online monitoring and chemometric modeling to the supernate of Hanford tank 241-AP-105, and demonstrated the quantitative measurement of nine analytes within this waste. Application of this method has been expanded to additional Hanford tank wastes, AW-102 and AP-107. The performance of the process monitoring instruments and the accuracy of the chemometric models will be assessed. On-line monitoring results will be compared to anion results determined from the current standard, ion-chromatographic and inductively coupled plasma mass spectrometry methods. Comparisons of both determined values and uncertainties of results will be presented. Results will be shared with personnel working on flowsheet interfaces for the Direct-Feed Low Activity Waste mission at Hanford. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗