Search NASA⌕ Search

SEARCH · Search NASA

Results for “gradient filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Collective epithelial cell sheet adhesion and migration on polyelectrolyte multilayers with uniform and gradients of compliance

Polyelectrolyte multilayers (PEMUs) are tunable thin films that could serve as coatings for biomedical implants. PEMUs built layer by layer with the polyanion poly(acrylic acid) (PAA) modified with a photosensitive 4-(2-hydroxyethoxy) benzophenone (PAABp) group and the polycation poly(allylamine hydrochloride) (PAH) are mechanically tunable by UV irradiation, which forms covalent bonds between the layers and increases PEMU stiffness. PAH-terminated PEMUs (PAH-PEMUs) that were uncrosslinked, UV-crosslinked to a uniform stiffness, or UV-crosslinked with an edge mask or through a neutral density optical gradient filter to form continuous compliance gradients were used to investigate how differences in PEMU stiffness affect the adhesion and migration of epithelial cell sheets from scales of the fish Poecilia sphenops (Black Molly) and Carassius auratus (Comet Goldfish). During the progressive collective cell migration, the edge cells (also known as ‘leader’ cells) in the sheets on softer uncrosslinked PEMUs and less crosslinked regions of the gradient formed more actin filaments and vinculin-containing adherens junctions and focal adhesions than formed in the sheet cells on stiffer PEMUs or glass. During sheet migration, the ratio of edge cell to internal cell (also known as ‘follower’ cells) motilities were greater on the softer PEMUs than on the stiffer PEMUs or glass, causing tension to develop across the sheet and periods of retraction, during which the edge cells lost adhesion to the substrate and regions of the sheet retracted toward the more adherent internal cell region. These retraction events were inhibited by the myosin II inhibitor Blebbistatin, which reduced the motility velocity ratios to those for sheets on the stiffer PEMUs. Blebbistatin also caused disassembly of actin filaments, reorganization of focal adhesions, increased cell spreading at the leading edge, as well as loss of edge cell-cell connections in epithelial cell sheets on all surfaces. Interestingly, cells throughout the interior region of the sheets on uncrosslinked PEMUs retained their actin and vinculin organization at adherens junctions after treatment with Blebbistatin. Like Blebbistatin, a Rho-kinase (ROCK) inhibitor, Y27632, promoted loss of cell-cell connections between edge cells, whereas a Rac1 inhibitor, NSC23766, primarily altered the lamellipodial protrusion in edge cells. Compliance gradient PAH-PEMUs promoted durotaxis of the cell sheets but not of individual keratocytes, demonstrating durotaxis, like plithotaxis, is an emergent property of cell sheet organization. - Highlights: • Fish scale cell sheets migrate on PAH-PAABp polyelectrolyte multilayers. • Sheets migrating on softer PEMUs periodically retract. • Sheets durotax on modulus gradients. • Myosin II inhibitors inhibit sheet integrity and migration.

60 APPLIED LIFE SCIENCES↗

Optical tomography reconstruction algorithm with the finite element method: An optimal approach with regularization tools

Highlights: •New strategies to improve the accuracy of the reconstruction through mesh and finite element parameterization. •Use of gradient filtering through an alternative inner product within the adjoint method. •An integral form of the cost function is used to make the reconstruction compatible with all finite element formulations, continuous and discontinuous. •Gradient-based algorithm with the adjoint method is used for the reconstruction. -- Abstract: Optical tomography is mathematically treated as a non-linear inverse problem where the optical properties of the probed medium are recovered through the minimization of the errors between the experimental measurements and their predictions with a numerical model at the locations of the detectors. According to the ill-posed behavior of the inverse problem, some regularization tools must be performed and the Tikhonov penalization type is the most commonly used in optical tomography applications. This paper introduces an optimized approach for optical tomography reconstruction with the finite element method. An integral form of the cost function is used to take into account the surfaces of the detectors and make the reconstruction compatible with all finite element formulations, continuous and discontinuous. Through a gradient-based algorithm where the adjoint method is used to compute the gradient of the cost function, an alternative inner product is employed for preconditioning the reconstruction algorithm. Moreover, appropriate re-parameterization of the optical properties is performed. These regularization strategies are compared with the classical Tikhonov penalization one. It is shown that both the re-parameterization and the use of the Sobolev cost function gradient are efficient for solving such an ill-posed inverse problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A compact x-ray spectrometer for measurements of electron temperature distributions in inertial confinement fusion implosions at OMEGA

The Wedge Range Filter (WRF), commonly used for proton spectroscopy at the OMEGA Laser Facility and National Ignition Facility, is adapted to measure the x-ray continuum spectrum through transmission measurement using a continuous-gradient filter. Continuum x rays emitted from the hotspot of an implosion contain information about the plasma composition and electron temperature. The WRF data are leveraged to probe this distribution, specifically the electron temperature distribution. In this work, the data recorded with the WRF are forward modeled using a temperature distribution model folded with the WRF response function. An uncertainty analysis is conducted through a Bayesian regression algorithm using a Hamiltonian Monte Carlo sampler. This analysis enables the uncertainties in the instrument response to be folded into the uncertainty estimation of the electron temperature and absolute x-ray emission. Data analysis for a series of OMEGA implosions is presented and compared with radiation hydrodynamic simulations.

Lasers↗

ECP Milestone Report WBS 2.3.4.13 ECP/VTK-m FY18Q1 [MS-18/01-03] Multiblock / Gradients / Release STDA05-5.

The FY18Q1 milestone of the ECP/VTK-m project includes the implementation of a multiblock data set, the completion of a gradients filtering operation, and the release of version 1.1 of the VTK-m software. With the completion of this milestone, the new multiblock data set allows us to iteratively schedule algorithms on composite data structures such as assemblies or hierarchies like AMR. The new gradient algorithms approximate derivatives of fields in 3D structures with finite differences. Finally, the release of VTK-m version 1.1 tags a stable release of the software that can more easily be incorporated into external projects.

97 MATHEMATICS AND COMPUTING↗

Three-dimensional tracking of cardiac catheters using an inverse geometry x-ray fluoroscopy system

Purpose: Scanning beam digital x-ray (SBDX) is an inverse geometry fluoroscopic system with high dose efficiency and the ability to perform continuous real-time tomosynthesis at multiple planes. This study describes a tomosynthesis-based method for 3D tracking of high-contrast objects and present the first experimental investigation of cardiac catheter tracking using a prototype SBDX system. Methods: The 3D tracking algorithm utilizes the stack of regularly spaced tomosynthetic planes that are generated by SBDX after each frame period (15 frames/s). Gradient-filtered versions of the image planes are generated, the filtered images are segmented into object regions, and then a 3D coordinate is calculated for each object region. Two phantom studies of tracking performance were conducted. In the first study, an ablation catheter in a chest phantom was imaged as it was pulled along a 3D trajectory defined by a catheter sheath (10, 25, and 50 mm/s pullback speeds). SBDX tip tracking coordinates were compared to the 3D trajectory of the sheath as determined from a CT scan of the phantom after the registration of the SBDX and CT coordinate systems. In the second study, frame-to-frame tracking precision was measured for six different catheter configurations as a function of image noise level (662-7625 photons/mm{sup 2} mean detected x-ray fluence at isocenter). Results: During catheter pullbacks, the 3D distance between the tracked catheter tip and the sheath centerline was 1.0{+-}0.8 mm (mean {+-}one standard deviation). The electrode to centerline distances were comparable to the diameter of the catheter tip (2.3 mm), the confining sheath (4 mm outside diameter), and the estimated SBDX-to-CT registration error ({+-}0.7 mm). The tip position was localized for all 332 image frames analyzed and 83% of tracked positions were inside the 3D sheath volume derived from CT. The pullback speeds derived from the catheter trajectories were within 5% of the programed pullback speeds. The tracking precision of ablation and diagnostic catheter tips ranged from {+-}0.2 mm at the highest image fluence to {+-}0.9 mm at the lowest fluence. Tracking precision depended on image fluence, the size of the tracked catheter electrode, and the contrast of the electrode. Conclusions: High speed multiplanar tomosynthesis with an inverse geometry x-ray fluoroscopy system enables 3D tracking of multiple high-contrast objects at the rate of fluoroscopic imaging. The SBDX system is capable of tracking electrodes in standard cardiac catheters with approximately 1 mm accuracy and precision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fermi Bubble Edges: Spectrum and Diffusion Function

Current measurements of the γ-ray Fermi bubbles (FB) are based on model-dependent tracers, carry substantial systematic uncertainties, and contain some discrepancies between each other. We show that gradient filters pick out the FB edges, which are found to smoothly connect to the bipolar X-ray structure emanating from the Galactic center, thus supporting the interpretation of the FBs as a Galactic-scale phenomenon. The sharp edges facilitate a direct, model-free measurement of the peripheral FB spectrum. The result is strikingly similar to the full FB-integrated spectrum, softened by a power law of index η ≃ (0.2–0.3). This is naturally explained, in both hadronic and leptonic models, if cosmic rays are injected at the edge, and diffuse away preferentially at higher energies E. The inferred, averaged diffusion function in the (more plausible) leptonic model, D(E)≃10{sup 29.5}(E/10GeV){sup 0.48±0.02} cm{sup 2} s{sup −1}, is consistent with estimates for Kraichnan-like turbulence. Our results, in particular the minute spatial variations in η, indicate that the FB edge is a strong, Mach ≳5, forward shock.

79 ASTRONOMY AND ASTROPHYSICS↗

Differential holography

Differential Holography technology measures the amplitude and/or phase of, e.g., an incident linearly polarized spatially coherent quasi-monochromatic optical field by optically computing the first derivative of the field and linearly mapping it to an irradiance signal detectable by an image sensor. This information recorded on the image sensor is then recovered by a simple algorithm. In some embodiments, an input field is split into two or more beams to independently compute the horizontal and vertical derivatives (using amplitude gradient filters in orthogonal orientations) for detection on one image sensor in separate regions of interest (ROIs) or on multiple image sensors. A third unfiltered beam recorded in a third ROI directly measures amplitude variations in the input field to numerically remove its contribution as noise before recovering the original wavefront using a numerical in algorithm. When combined, the measured amplitude and phase constitute a holographic recording of the incident optical field.

Ravizza, Frank↗

Reconstructing small-scale lenses from the cosmic microwave background temperature fluctuations

Cosmic microwave background (CMB) lensing is a powerful probe of the matter distribution in the Universe. The standard quadratic estimator, which is typically used to measure the lensing signal, is known to be suboptimal for low-noise polarization data from next-generation experiments. In this paper, we explain why the quadratic estimator will also be suboptimal for measuring lensing on very small scales, even for measurements in temperature where this estimator typically performs well. Though maximum likelihood methods could be implemented to improve performance, we explore a much simpler solution, revisiting a previously proposed method to measure lensing that involves a direct inversion of the background gradient. An important application of this simple formalism is the measurement of cluster masses with CMB lensing. We find that directly applying a gradient inversion matched filter to simulated lensed images of the CMB can tighten constraints on cluster masses compared to the quadratic estimator. While the difference is not relevant for existing surveys, for future surveys it can translate to significant improvements in mass calibration for distant clusters, where galaxy lensing calibration is ineffective due to the lack of enough resolved background galaxies. Improvements can be as large as ~50 per cent for a cluster at z = 2 and a next-generation CMB experiment with 1 μK arcmin noise, and over an order of magnitude for lower noise levels. For future surveys, this simple matched filter or gradient inversion method approaches the performance of maximum likelihood methods, at a fraction of the computational cost.

79 ASTRONOMY AND ASTROPHYSICS↗

Ecohydrology of wetland plant communities along an estuarine to tidal river gradient

Abiotic filters that interact with wetland plant communities along tidal–fluvial gradients are highly dynamic, and understanding their quantitative thresholds and relationships to interspecific competition is important during an era of sea-level rise and watershed hydrologic change. Yet, landscape-scale studies of major coastal rivers from the river mouth to the head of tide, such as this study, remain rare. Here, we develop a new predictive framework for estuarine–tidal river research and management using a river-specific low-water datum and the wetland inundation indicator SEVg, the growing-season sum exceedance value of hourly surface-water depth. The distribution and variability of the wetland species pool (n = 203) on the 234 river kilometer (rkm) lower Columbia River and estuary floodplain are described for the first time. 4,940 quadrats at 50 marshes were surveyed (2005–2016). Throughout the estuarine–tidal river system, SEVg was well suited to describe the wetland inundation regime and its variability based on the combination of longitudinal river position and elevation. SEVg increased significantly landward. Two primary wetland inundation regimes were identified: the seaward-tidal, usually greatest during the winter months, and landward-fluvial, greatest during the growing season. Nearest the ocean, salinity is the abiotic factor limiting species richness and non-native species. Farther upriver, the daily, seasonal, and interannual variability of the wetting and drying cycle encourage disturbance-tolerant species and non-natives and limit the number of hydrophytes and total vegetative cover. Hence, the average between-year similarity of site-scale areal cover significantly decreased landward. Hierarchical cluster analysis indicated five vegetative groups and five ecohydrologic zones between rkm 0 and 234 were discriminated with 76 significant species–zone associations. All zones had unique indicator species. Species with high indicator values were Carex lyngbyei throughout the estuarine zones, and Eleocharis palustris, Sagittaria latifolia, and the invasive non-native Phalaris arundinacea in the upper estuarine and lower, middle, and upper tidal river zones (IV > 0.90). Competition from C. lyngbyei nearest the ocean and P. arundinacea in the tidal river was associated with reduced species richness when total cover was >65%. This framework of filters informs the design and prediction of future wetland plant communities on coastal river floodplains.

54 ENVIRONMENTAL SCIENCES↗

Yet another parameter-free shape optimization method

The use of node coordinates as design variables in shape optimization offers a larger design space than computer-aided design (CAD)-based shape parameterizations. It also allows for the optimization of legacy designs, i.e., a finite element mesh from an existing design can be readily optimized to meet new performance requirements without involving a CAD model. However, it is well known that the node coordinate parameterization method is fraught with numerical difficulties, which makes it impractical to use. This has led to several of “parameter-free” shape optimization methods that seek the advantages and avoid the pitfalls of the naïve node coordinate parameterization method. These methods come in two main varieties: sensitivity filtering (or gradient smoothing) and consistent filtering. The latter is analogous to the density filter method used in topology optimization (TO). In this work, we use the PDE filter from TO and energy-based filters to implement consistent shape optimization filtering schemes easily and efficiently. Numerical experiments demonstrate that consistent methods are more robust than sensitivity filtering methods.

42 ENGINEERING↗

Computer-aided measurement of liver volumes in CT by means of geodesic active contour segmentation coupled with level-set algorithms

Purpose: Computerized liver extraction from hepatic CT images is challenging because the liver often abuts other organs of a similar density. The purpose of this study was to develop a computer-aided measurement of liver volumes in hepatic CT. Methods: The authors developed a computerized liver extraction scheme based on geodesic active contour segmentation coupled with level-set contour evolution. First, an anisotropic diffusion filter was applied to portal-venous-phase CT images for noise reduction while preserving the liver structure, followed by a scale-specific gradient magnitude filter to enhance the liver boundaries. Then, a nonlinear grayscale converter enhanced the contrast of the liver parenchyma. By using the liver-parenchyma-enhanced image as a speed function, a fast-marching level-set algorithm generated an initial contour that roughly estimated the liver shape. A geodesic active contour segmentation algorithm coupled with level-set contour evolution refined the initial contour to define the liver boundaries more precisely. The liver volume was then calculated using these refined boundaries. Hepatic CT scans of 15 prospective liver donors were obtained under a liver transplant protocol with a multidetector CT system. The liver volumes extracted by the computerized scheme were compared to those traced manually by a radiologist, used as ''gold standard.''Results: The mean liver volume obtained with our scheme was 1504 cc, whereas the mean gold standard manual volume was 1457 cc, resulting in a mean absolute difference of 105 cc (7.2%). The computer-estimated liver volumetrics agreed excellently with the gold-standard manual volumetrics (intraclass correlation coefficient was 0.95) with no statistically significant difference (F=0.77; p(F{<=}f)=0.32). The average accuracy, sensitivity, specificity, and percent volume error were 98.4%, 91.1%, 99.1%, and 7.2%, respectively. Computerized CT liver volumetry would require substantially less completion time (compared to an average of 39 min per case by manual segmentation). Conclusions: The computerized liver extraction scheme provides an efficient and accurate way of measuring liver volumes in CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three filters for visualization of phase objects with large variations of phase gradients

We propose three amplitude filters for visualization of phase objects. They interact with the spectra of pure-phase objects in the frequency plane and are based on tangent and error functions as well as antisymmetric combination of square roots. The error function is a normalized form of the Gaussian function. The antisymmetric square-root filter is composed of two square-root filters to widen its spatial frequency spectral range. Their advantage over other known amplitude frequency-domain filters, such as linear or square-root graded ones, is that they allow high-contrast visualization of objects with large variations of phase gradients.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simple through-plane spatial filter for 2D MRI projections

A simple spatial filter for 2D projection MR imaging is introduced. It works in the third (unresolved) direction to eliminate uniform or slowly varying interfering background signals. A constant amplitude gradient pulse in the unresolved direction is applied at the same time as the usual phase encode gradient during 2D acquisition. The filter is demonstrated for root imaging in soil, where background soil water signals can be troublesome. The filter suppresses the soil water signal while preserving the desired signal of plant roots. Fundamental to the operation of the filter is that the roots are sparse in the image domain, meaning there are relatively few pixels with multiple roots present. Here, the performance of the through-plane filter is demonstrated and compares favorably to more conventional in-plane spatial filtering.

47 OTHER INSTRUMENTATION↗

Clear-air Vertical Air Motion Within the Marine Boundary Layer

The Doppler lidars (DL) at the ARM observatories operate at 1.5-micrometer wavelength and record backscatter and mean Doppler velocity. The DL present at the ARM ENA site records these quantities at a 1-second temporal and 30-meter range resolution. Reported here are daily files containing gridded values of noise-filtered and calibrated backscatter, and noise-filtered mean Doppler velocity. In addition we also report the noise-filtered and calibrated gradient of backscatter that is used to derive estimates of cloud base height. All of the variables are reported at a uniform 5-second temporal resolution and 30-m range resolution. The instrument reported raw backscatter was first corrected for telescope focus function, filtered for noise, and then calibrated by exploiting the constant lidar ratio exhibited during nonprecipitating stratocumulus cloud conditions. Hence, the reported backscatter can be used to derive aerosol and hydrometeor properties. Daily files are reported for the summer Intensive Operational Period (IOP) of the Aerosol, and Cloud and Experiments in the Eastern North Atlantic (ACE-ENA) field campaign. Similar files can be produced for any DL at ARM observatories. Please find below the header of the NetCDF files. double time (time) ; time:Long_Name = "Time" ; time:units = "Seconds from 1970-1-1 0:00:00" ; double height (height) ; height:Long_Name = "Height" ; height:units = "meters" ; double dl_el (time) ; dl_el:Long_Name = "elevation" ; dl_el:units = "degrees"; double dl_beta (time, height) ; dl_beta:Long_Name = "Noise Filtered Calibrated Backscatter" ; dl_beta:units = "1 / (m * Sr)" ; double dl_velo (time, height); dl_velo:Long_Name = "Mean Doppler Velocity" ; dl_velo:units = "m/s" ; double dl_att (time, height) ; dl_att:Long_Name = "Gradient of Backscatter" ; dl_att:units = "1 / (m ^ 2 * Sr)" ; double base (time) ; base:Long_Name = "Cloud base height" ; base:units = "meters" ;

54 ENVIRONMENTAL SCIENCES↗

Evidence for a role of claudin 2 as a proximal tubular stress responsive paracellular water channel

Claudins are the major proteins of the tight junctions and the composition of claudin subtypes is decisive for the selective permeability of the paracellular route and thus tissue specific function. Their regulation is complex and subject to interference by several factors, including oxidative stress. Here we show that exposure of cultured human proximal tubule cells (RPTEC/TERT1) to the immunosuppressive drug cyclosporine A (CsA) induces an increase in transepithelial electrical resistance (TEER), a decrease in dome formation (on solid growth supports) and a decrease in water transport (on microporous growth supports). In addition, CsA induced a dramatic decrease in the mRNA for the pore forming claudins -2 and -10, and the main subunits of the Na{sup +}/K{sup +} ATPase. Knock down of claudin 2 by shRNA had no discernable effect on TEER or dome formation but severely attenuated apical to basolateral water reabsorption when cultured on microporous filters. Generation of an osmotic gradient in the basolateral compartment rescued water transport in claudin 2 knock down cells. Inhibition of Na{sup +}/K{sup +} ATPase with ouabain prevented dome formation in both cell types. Taken together these results provide strong evidence that dome formation is primarily due to transcellular water transport following a solute osmotic gradient. However, in RPTEC/TERT1 cells cultured on filters under iso-osmotic conditions, water transport is primarily paracellular, most likely due to local increases in osmolarity in the intercellular space. In conclusion, this study provides strong evidence that claudin 2 is involved in paracellular water transport and that claudin 2 expression is sensitive to compound induced cellular stress. - Highlights: • Cyclosporine A increased TEER and decreased water transport in RPTEC/TERT1 cells. • Claudins 2 and 10 were decreased in response to cyclosporine A. • Knock down of claudin 2 inhibited water transport in proximal tubular cells. • We propose that claudin 2 is a nephrotoxin sensitive water channel.

60 APPLIED LIFE SCIENCES↗

Improved filters for angular filter refractometry

Angular filter refractometry is an optical diagnostic that measures the absolute contours of a line-integrated density gradient by placing a filter with alternating opaque and transparent zones in the focal plane of a probe beam, which produce corresponding alternating light and dark regions in the image plane. Identifying transitions between these regions with specific zones on the angular filter (AF) allows the line-integrated density to be determined, but the sign of the density gradient at each transition is degenerate and must be broken using other information about the object plasma. Additional features from diffraction in the filter plane often complicate data analysis. Here, in this paper, we present an improved AF design that uses a stochastic pixel pattern with a sinusoidal radial profile to minimize unwanted diffraction effects in the image caused by the sharp edges of the filter bands. We also present a technique in which a pair of AFs with different patterns on two branches of the same probe beam can be used to break the density gradient degeneracy. Both techniques are demonstrated using a synthetic diagnostic and data collected on the OMEGA EP (extended performance) laser.

47 OTHER INSTRUMENTATION↗

QuCNN : A Quantum Convolutional Neural Network with Entanglement Based Backpropagation

Quantum Machine Learning continues to be a highly active area of interest within Quantum Computing. Many of these approaches have adapted classical approaches to the quantum settings, such as QuantumFlow, etc. We push forward this trend, and demonstrate an adaption of the Classical Convolutional Neural Networks to quantum systems - namely QuCNN. QuCNN is a parameterised multi-quantum-state based neural network layer computing similarities between each quantum filter state and each quantum data state. With QuCNN, back propagation can be achieved through a single-ancilla qubit quantum routine. QuCNN is validated by applying a convolutional layer with a data state and a filter state over a small subset of MNIST images, comparing the backpropagated gradients, and training a filter state against an ideal target state.

high performance computing, quantum computing↗

Computerized image analysis: Texture-field orientation method for pectoral muscle identification on MLO-view mammograms

Purpose: To develop a new texture-field orientation (TFO) method that combines a priori knowledge, local and global information for the automated identification of pectoral muscle on mammograms. Methods: The authors designed a gradient-based directional kernel (GDK) filter to enhance the linear texture structures, and a gradient-based texture analysis to extract a texture orientation image that represented the dominant texture orientation at each pixel. The texture orientation image was enhanced by a second GDK filter for ridge point extraction. The extracted ridge points were validated and the ridges that were less likely to lie on the pectoral boundary were removed automatically. A shortest-path finding method was used to generate a probability image that represented the likelihood that each remaining ridge point lay on the true pectoral boundary. Finally, the pectoral boundary was tracked by searching for the ridge points with the highest probability lying on the pectoral boundary. A data set of 130 MLO-view digitized film mammograms (DFMs) from 65 patients was used to train the TFO algorithm. An independent data set of 637 MLO-view DFMs from 562 patients was used to evaluate its performance. Another independent data set of 92 MLO-view full field digital mammograms (FFDMs) from 92 patients was used to assess the adaptability of the TFO algorithm to FFDMs. The pectoral boundary detection accuracy of the TFO method was quantified by comparison with an experienced radiologist's manually drawn pectoral boundary using three performance metrics: The percent overlap area (POA), the Hausdorff distance (Hdist), and the average distance (AvgDist). Results: The mean and standard deviation of POA, Hdist, and AvgDist were 95.0{+-}3.6%, 3.45{+-}2.16 mm, and 1.12{+-}0.82 mm, respectively. For the POA measure, 91.5%, 97.3%, and 98.9% of the computer detected pectoral muscles had POA larger than 90%, 85%, and 80%, respectively. For the distance measures, 85.4% and 98.0% of the computer detected pectoral boundaries had Hdist within 5 and 10 mm, respectively, and 99.4% of computer detected pectoral muscle boundaries had AvgDist within 5 mm from the radiologist's manually drawn boundaries. Conclusions: The pectoral muscle on DFMs can be detected accurately by the automated TFO method. The preliminary study of applying the same pectoral muscle identification algorithm to FFDMs without retraining demonstrates that the TFO method is reasonably robust against the differences in the image properties between the digitized and digital mammograms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗