Search NASA⌕ Search

SEARCH · Search NASA

Results for “gravity energy storage system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Optimizing Grid Regulation with Gravity Energy Storage Systems: A Comparative Analysis with Different Motor Inertias

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid imbalances in generation and demand is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS scenarios provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 s from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS based on a highinertia motor may be able to operate over a broader range of frequency variations, whereas a low-inertia system may be limited by thermal constraints of the motor.

ENERGY STORAGE,POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing Grid Regulation With Gravity Storage Systems: A Comparative Analysis With Different Motor Inertias

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid imbalances in generation and demand is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS scenarios provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 s from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS based on a high-inertia motor may be able to operate over a broader range of frequency variations, whereas a low-inertia system may be limited by thermal constraints of the motor.

frequency regulation↗

Optimizing Grid Regulation With Gravity Storage Systems: A Comparative Analysis With Different Motor Inertias: Preprint

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between the energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid generation-demand imbalances is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS systems provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 seconds from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS with a high-inertia motor may be able operate over a broader range of frequency variations whereas a low-inertia system may be limited by thermal constraints of the motor.

frequency regulation↗

Pilot Development Progress to Demonstrate Electric Thermal Energy Storage (ETES) Using Low-Cost Particles

The rapid growth of future energy demand increases the need to economically store electrical energy over durations up to several days in long-duration energy storage (LDES) applications. LDES can reduce the grid stress for improving the resilience of the grid. The integration of renewable power and storage has several significant and positive impacts including expanding the renewable energy portion of electricity generation, meeting peak-load demand, and coordinating supply and demand. Several energy storage approaches including mechanical, chemical and electrochemical methods are currently deployed or under development. However, LDES requirements pose unique challenges for scalability, energy capacity, and cost. Thermal energy storage (TES) has the ability to store a large capacity of energy with improved site flexibility compared to incumbent LDES technologies (i.e., pumped hydro) and has attracted significant interest. Our development in TES technology using solid particles as the storage medium has shown feasibility and potential in serving LDES purposes. Particle TES has various advantages over commercialized molten nitrate salt TES and has emerged as a promising storage technology originating from Generation 3 concentrating solar power (CSP) development. Stable, inexpensive silica sand produced in the Midwestern U.S. was identified as a suitable storage medium and has been validated through lab heating and cycling tests. We have successfully developed particle TES for bidirectional electric energy storage to broaden the applications for TES beyond CSP technologies and into standalone electric-thermal energy storage (ETES) systems. Key component designs and performance were verified with prototype testing and model simulations. The ETES system uses high-temperature, low-cost particle thermal energy storage coupled with a unique pressurized fluidized bed heat exchanger that supports a high-efficiency, air-Brayton combined power cycle. At times of low energy demand or high renewable production, an electric particle heater heats large quantities of solid particles to high temperatures in excess of 1100 degrees C. The particles are stored in internally insulated silos. At times of high electricity demand, the hot particles are gravity-fed through the heat exchanger where stored thermal energy is transferred to the power cycle working fluid to drive the gas turbine power generation system, thereby converting the thermal energy back into electricity for the grid. The cold particles leaving the heat exchanger are returned to the storage silos by a well-insulated particle conveyor. This ETES technology using particle TES can be sited anywhere and is predicted to be economic and efficient. Moreover, this ETES technology could be co-located with a retired coal or gas plant to leverage existing power generation and grid infrastructure. Our work has focused on the development of each of the key components (e.g., the electric particle heater, particle storage silos, and the particle-to-gas pressurized fluidized bed heat exchanger) through conceptual designs, prototype testing, and computational modeling. These developments demonstrate technological feasibility and are an important step towards the next phase of development of this promising LDES technology. This presentation will show the progress in developing a pilot demonstration of the ETES system on a commercially relevant scale.

25 ENERGY STORAGE↗

Energy Storage Technologies and U.S. Department of War Requirements

This report offers an overarching primer the energy storage market and assessment of each technology’s suitability for U.S. Department of War applications. We find that battery energy storage is the most promising technology for energy storage applications in terms of energy density and cost. While commercial and advanced Li-ion can satisfy certain electric mobility (e.g., cars, midsized vehicles) and electric flight application (e.g. drones) needs of DoW, next generation technologies like Li metal solid-state batteries, and conversion chemistries (Li-air, Li-CFx) are needed for heavy duty applications like armored vehicles, tanks, airplanes, jets. Batteries should also be supplemented with technologies such as supercapacitors and next-generation flywheels to provide short bursts of high energy for high power needs. Thermal energy storage solutions (sensible and latent heat) and fuel cells (PEMFC and SOFC) are good alternatives for supporting energy storage applications in terms of energy density and cost. Gravity-based energy storage promises the least energy density with high cost and should only be used for niche DoW applications. Of the different gravity energy storage technologies reviewed, pumped-hydro, flywheel, and compressed air energy storage are promising, while solid gravity energy storage appears the least attractive. Military facilities requiring 14 days of energy storage can benefit from flow batteries, especially commercial VFRBs and next generation iron-air systems. While VFRBs are expensive, iron-air batteries have the coupled benefits of low cost and good energy density promising 100+ hours of storage.

25 ENERGY STORAGE↗

Gravity Well Commercial Economics Assessment: Potential Revenue and Cost: Cooperative Research and Development (Final Report)

In the Gravity Well Revenue Study, we evaluate the potential revenue from energy storage using historical energy-only electricity prices, forward-looking projections of hourly electricity prices, and actual reported revenue. This analysis examines the impact of storage duration and round-trip efficiency, as well as the location of the storage, on storage revenue within the current and projected U.S. power system. We also investigated the impact of round-trip efficiency on storage revenue. We found that the relationship between storage revenue and round-trip efficiency is nonlinear. The value of improved round-trip efficiency declines as round-trip efficiency increases. In the Gravity Well Future Cost Study, we applied learning curves to predict the future cost trajectory of Gravity Wells (GrWs). Two types of analysis were implemented. The first was a bottom-up analysis that used historical learning rates for cost components, such as motors and gearboxes, and cost categories (e.g., engineering and design, etc.) to determine the learning-by-doing based single-factor learning curve. The single factor learning curve expresses the relationship between the cost of GrW and the number of units deployed (or the cumulative capacity). In the second analysis, we predicted future GrW costs via a top-down approach. This approach accounts for historical cost trends in other renewable energy and storage technologies, which have similarities with GrWs. Using a multifactor learning curve that accounts for both intrinsic (cumulative capacity) and extrinsic (the elasticity in the price of steel) factors, we estimated the future cost of GrWs.

25 ENERGY STORAGE↗

Nine Canyon Long-Duration Energy Storage: A Feasibility Study

The Nine Canyon Long Duration Energy Storage (LDES) Feasibility Study explores the technical and economic viability of deploying advanced energy storage technologies at Energy Northwest's (EN) Nine Canyon (9C) Wind Project site in Benton County, Washington. Supported by the Washington State Department of Commerce and the U.S. Department of Energy’s Office of Electricity under its LDES Voucher Program, the study represents a collaborative effort between EN, Pacific Northwest National Laboratory (PNNL), and ARES North America. At the core of this effort is the development of a generalized techno-economic modeling framework and evaluation tool designed to assess the value proposition of LDES projects across a variety of contexts. The modeling tool is technology-agnostic and accommodates user-defined parameters such as rated power, energy duration, round-trip efficiency, capital and operational costs, and dispatch constraints. It also integrates economic inputs, including market prices, energy revenue structures, and financing parameters to evaluate performance through key metrics. The tool provides utilities with a transparent, adaptable platform to support decision-making, investment prioritization, and portfolio planning for various storage technologies. To guide scenario design and interpretation, the study first surveyed the LDES technology landscape, including lithium-ion batteries, flow batteries, non-hydro gravity storage, and thermo-mechanical systems, comparing cost trajectories, technical performance, safety and hazards, materials sourcing and recyclability, and spatial/siting considerations. This literature-grounded review highlights technology trade-offs and reinforces the need to align technology choice with site characteristics, use cases, and project objectives. A companion chapter examines ownership structures (EN ownership, third-party ownership, shared models) and offtake options (energy marketing, capacity/energy PPAs, time-of-use PPAs, block-delivery PPAs, and tolling), where PPAs (power purchase agreements) represent contractual arrangements for buying and selling electricity. The chapter also highlights implications for risk allocation, capital access, operational control, and revenue certainty. The study also evaluates supervisory control and data acquisition (SCADA) and transmission interconnection pathways, options include upgrading the existing SCADA or deploying a dedicated LDES controller, with attention to protection schemes, data telemetry, cybersecurity, and regulatory coordination with BPA. In addition, an ARES-specific geotechnical and hydrology assessment presented in the appendix screens multiple corridors for slope stability, bearing capacity, cut-and-fill magnitude, and stormwater behavior.

25 ENERGY STORAGE↗

Hydrogen, Methane, Brine Flow Behavior, and Saturation in Sandstone Cores During H 2 and CH 4 Injection and Displacement

Large-scale underground hydrogen storage (UHS) is a critical component in the emerging hydrogen economy. Knowledge of multiphase flow behavior involving hydrogen in storage reservoir formations is crucial to characterizing hydrogen transport properties and essential for the deliverability and storage operations of UHS. There are still many gaps in fully understanding hydrogen–methane–brine multiphase phase flow that require further investigation. In this work, H 2 and CH 4 were injected through brine-saturated sandstone cores using a tri-axial core holder system fitted with flow rate meters and pressure transducers, while the effluent gas concentrations were analyzed using an online micro gas chromatograph. Brine displacement, permeability, and gas breakthrough curves were measured. We studied the flow behavior of hydrogen and methane in sandstone cores through testing brine displacement by gas injection and comparing the hydrogen displacement of methane with the methane displacement of hydrogen. We also tested the differences between horizontal and vertical flow in brine displacement. The results showed that brine displacement was more efficient in a core with higher permeability and porosity, resulting in a higher initial gas saturation. A higher gas injection rate brought about faster gas breakthrough measured by pore volume and sharper concentration curves. Hydrogen did not exhibit abnormal flow in the sandstone when the flow was horizontal and downward vertical. Gas overriding was observed in brine displacements when the flow was horizontal, with hydrogen showing this behavior more profoundly compared to methane. Downward vertical gas injection induced higher efficiency brine displacement compared to horizontal displacement and resulted in a higher initial gas saturation in the sandstone cores. These findings address critical knowledge gaps regarding gas flow patterns and displacement behaviors during hydrogen injection and recovery phases in UHS facilities using methane as the cushion gas. The insights from this research offer valuable guidance for optimizing UHS systems, ensuring operational efficiency, and advancing sustainable energy solutions in alignment with decarbonization goals.

08 HYDROGEN↗

Watching the Grand Ethiopian Renaissance Dam from a distance: Implications for sustainable water management of the Nile water

Increased demands for sustainable water and energy resources in densely populated basins have led to the construction of dams, which impound waters in artificial reservoirs. In many cases, scarce field data led to the development of models that underestimated the seepage losses from reservoirs and ignored the role of extensive fault networks as preferred pathways for groundwater flow. We adopt an integrated approach (remote sensing, hydrologic modeling, and field observations) to assess the magnitude and nature of seepage from such systems using the Grand Ethiopian Renaissance Dam (GERD), Africa's largest hydropower project, as a test site. The dam was constructed on the Blue Nile within steep, highly fractured, and weathered terrain in the western Ethiopian Highlands. The GERD Gravity Recovery and Climate Experiment Terrestrial Water Storage (GRACETWS), seasonal peak difference product, reveals significant mass accumulation (43 ± 5 BCM) in the reservoir and seepage in its surroundings with progressive south-southwest mass migration along mapped structures between 2019 and 2022. Seepage, but not a decrease in inflow or increase in outflow, could explain, at least in part, the observed drop in the reservoir's water level and volume following each of the three fillings. Using mass balance calculations and GRACETWS observations, we estimate significant seepage (19.8 ± 6 BCM) comparable to the reservoir's impounded waters (19.9 ± 1.2 BCM). Investigating and addressing the seepage from the GERD will ensure sustainable development and promote regional cooperation; overlooking the seepage would compromise hydrological modeling efforts on the Nile Basin and misinform ongoing negotiations on the Nile water management.

GRACE and GRACE-FO↗

Numerical Evaluation of Effective Thermal Conductivity of PCM with Metal Foam Incorporating Buoyancy Effects for Thermal Energy Storage

The thermal energy storage (TES) system has the capability to efficiently preserve thermal energy directly derived from the energy source, minimizing any conversion losses. Especially latent heat storage offers distinct advantages, including a substantial increase in energy storage density and minimization of temperature fluctuations within the plants. However, the phase change material (PCM) employed in latent heat storage has low thermal conductivity. Consequently, various studies are being conducted to enhance heat transfer. One approach to enhance heat transfer involves utilizing metal foam to maximize the heat transfer area. However, modeling metal foam with its intricate structure is a challenging task in numerical analysis. For this reason, ongoing research focuses on simplifying the modeling of metal foam. Nevertheless, fully encompassing all the characteristics of actual metal foam proves to be a challenging task for the simplified analytical model. The objective of this paper is to interpret the simple lattice metal foam analysis model from the perspective of behavior induced by buoyancy. When comparing the analysis results of solid PCM and liquid PCM with the same thermal conductivity under changes in porosity and gravity direction, we conducted an analysis to discern the trends in effective thermal conductivity that are overestimated due to convection. In the analysis, a constant heat flux of 10 kW and a constant surface boundary condition of 350 K were applied, and a sensitivity study regarding the mesh was conducted. The results indicate that, from the perspective of gravity in the simple lattice model, the solid analysis yields an effective thermal conductivity 29-47% higher compared to the liquid analysis. Additionally, as porosity increases, there is an observed increase of 24-33% in effective thermal conductivity.

25 ENERGY STORAGE↗

Generating Buoyancy-Driven Convection in Membrane Distillation

Membrane distillation (MD) is a thermally-driven desalination process that can treat hypersaline brines. Considerable MD literature has focused on mitigating temperature and concentration polarization. This literature largely neglects that temperature and concentration polarization increase the feed density near the membrane. With gravity properly oriented, this increase in density could trigger buoyancy-driven convection and increase permeate production. Convection could also be strengthened by heating the feed channel wall opposite the membrane. To investigate that possibility, we perform a series of experiments using a plate-and-frame direct contact MD system with an active membrane area of 300 cm2 and a feed channel wall heated using a resistive heater. The experiments measure the average transmembrane permeate flux for two gravitational orientations, feed Reynolds numbers between 128 and 1128, and wall heat fluxes up to 12 kW/m2. The results confirm that with gravity properly oriented, wall-heating can trigger buoyancy-driven convection for a wide range of feed Reynolds numbers, and increase permeate production between roughly 20 and 130 %. We estimate, however, that at high Reynolds numbers (Re > 800), more than 70 % of the wall heat is carried out of the MD system by the feed flow, without contributing to permeate production. This suggests the need for longer membranes and heat recovery steps in any future practical implementation.

buoyancy-driven convection↗

Compact Counter Flow Fluidized Bed Heat Exchanger (Final Report)

Generation 3 concentrating solar power systems which utilize solid granular media as the heat transfer and storage media hold promise in reducing the levelized cost of electricity relative to generation 2 systems which utilize molten salt. The particles can be heated to temperatures exceeding 800 °C which enables the use of high efficiency supercritical CO 2 Brayton power cycles. A key challenge associate with the use of solid media is its low bulk thermal conductivity which limits the ability to transfer heat from the particles to a working fluid, such as supercritical CO 2 . Tradition shell and tube and shell and plate heat exchangers feature gravity driven particle flow which limits the maximum particle side heat transfer coefficient in these systems to approximately 400 W/m 2 K. A fluidized bed heat exchanger does not rely solely on gravity for particle flow. Instead, enhanced mixing and horizontal conveyance is achieved through fluidization induced through air injection at the bottom of a bed of particles. A tube bundle within the bed conveys the supercritical CO 2 which is heated via the turbulent particle motion at the tube wall.

14 SOLAR ENERGY↗