Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Greedy permanent magnet optimization

Abstract A number of scientific fields rely on placing permanent magnets in order to produce a desired magnetic field. We have shown in recent work that the placement process can be formulated as sparse regression. However, binary, grid-aligned solutions are desired for realistic engineering designs. We now show that the binary permanent magnet problem can be formulated as a quadratic program with quadratic equality constraints, the binary, grid-aligned problem is equivalent to the quadratic knapsack problem with multiple knapsack constraints, and the single-orientation-only problem is equivalent to the unconstrained quadratic binary problem. We then provide a set of simple greedy algorithms for solving variants of permanent magnet optimization, and demonstrate their capabilities by designing magnets for stellarator plasmas. The algorithms can a-priori produce sparse, grid-aligned, binary solutions. Despite its simple design and greedy nature, we provide an algorithm that compares with or even outperforms the state-of-the-art algorithms while being substantially faster, more flexible, and easier to use.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Metrics and Analytical Frameworks for Valuing Energy Efficiency and Distributed Energy Resources in the Built Environment: Preprint

This paper summarizes efforts to develop new—and enhance existing—analytical frameworks and metrics to quantify the value that grid-interactive efficient homes with solar (GEB-solar homes) can provide. Industry is working to characterize and understand these capabilities and benefits, but existing analytical frameworks for evaluating energy efficiency (EE) are often siloed from those that evaluate distributed energy resources (DERs). Five metrics were adapted from an extensive literature review and applied to case studies of a modeled home in Riverside, California: ramp up/down, cover factor demand/supply, and curtailable load. Eight different technology scenarios were analyzed using a more tightly connected suite of building-to-grid models (BEopt, REopt, ReEDS, and PLEXOS). Additionally, an initial version of the Cambium tool was developed, characterizing the marginal prices and emissions from NREL’s 2018 Standard Scenarios. These grid costs were extended to a time-varying proxy retail rate and applied as part of a new grid alignment metric. In the results, a more integrated combination of GEB-solar technologies led to a higher cover factor demand—the percentage of gross home load covered by on-site solar—however, a benchmark was required to determine what range of cover factor was “best” for given grid conditions. To that end, a grid alignment cost metric was applied to the case study scenarios. The average cost to serve the net load of the home decreased from a median of ~$0.24/kWh to ~$0.10/kWh when the most integrated technology scenario was optimized towards the grid pricing proxy versus the time-of-use (TOU) rate.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Parallel diffusion operator for magnetized plasmas with improved spectral fidelity

Diffusive transport processes in magnetized plasmas are highly anisotropic, with fast parallel transport along the magnetic field lines sometimes faster than perpendicular transport by orders of magnitude. This constitutes a major challenge for describing non-grid-aligned magnetic structures in Eulerian (grid-based) simulations. Here, the present paper describes and validates a new method for parallel diffusion in magnetized plasmas based on the anti-symmetry representation [Halpern and Waltz, Phys. Plasmas 25, 060703 (2018)]. In the anti-symmetry formalism, diffusion manifests as a flow operator involving the logarithmic derivative of the transported quantity. Qualitative plane wave analysis shows that the new operator naturally yields better discrete spectral resolution compared to its conventional counterpart. Numerical simulations comparing the new method against existing finite difference methods are carried out, showing significant improvement. In particular, we find that combining anti-symmetry with finite differences in diagonally staggered grids essentially eliminates the so-called “artificial numerical diffusion” that affects conventional finite difference and finite volume methods.

Anisotropic diffusion↗

A Shock Stabilization of the HLLC Riemann Solver for the Carbuncle Instability

The HLLC approximate Riemann solver improves upon the HLL Riemann solver by resolving contact discontinuities. This is a particularly desirable property for multi-material codes in which problems usually contain material interfaces. However, the HLLC solver is known to suffer from the carbuncle phenomenon, a numerical instability most apparent at grid-aligned shocks in multi-dimensional simulations. Many problems of interest, including high energy-density physics applications, require the accurate resolution of both material interfaces and hydrodynamic shocks. A variety of methods have been developed to cure this instability, with varying degrees of complexity. The objective of this work is to describe a simple approach to modify the HLLC Riemann solver and prevent the carbuncle instability. Here, the method is then demonstrated for assorted two-dimensional test problems known to exhibit the shock instability. The performance of the new solver is compared with that of the standard HLL and HLLC Riemann solvers.

97 MATHEMATICS AND COMPUTING↗

Implementation of a 9-point stencil in SOLPS-ITER and implications for Alcator C-Mod divertor plasma simulations

The SOLPS-ITER code suite is used worldwide for plasma edge modeling, the interpretation of experiments, as well as for the design of the ITER divertor. The numerical scheme of the plasma solver of the code, B2.5, is based on the assumption of perfectly field-aligned grids, while in practice grids are often strongly distorted to match divertor target shapes. Neglecting these grid distortion leads to qualitatively and quantitatively incorrect results for fluid neutral simulations, and may affect results in cold (detached) divertors even when using kinetic neutral simulations. In this contribution, we present the first results of a newly implemented 9-point stencil in B2.5 to properly handle misaligned grids. The new scheme is then applied to fluid neutral simulations of a well-diagnosed and previously modeled Alcator C-Mod discharge. Results are compared with the original 5-point scheme neglecting grid distortion effects, as well as with simulations including a full kinetic neutral model. We conclude that the 9-point stencil is essential to correctly model the transport of fluid neutrals on distorted grids, and to capture the effects of divertor closure on the fluid neutral behavior.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Unsupervised anomaly clustering via offset alignment in multivariate grid sensing data

Modern industries increasingly rely on multi-sensor technologies to acquire complex, high-dimensional data streams, enabling advanced monitoring and control systems. One critical application is online anomaly detection in electrical smart grids, where multivariate and multimodal sensing technologies play a vital role. However, detecting anomalies in such time-series data is challenging due to their inherent temporal dependencies and stochastic behavior. Traditional approaches based on supervised and semi-supervised learning methods depend on labeled datasets, which are often unavailable in real-world scenarios. While unsupervised methods have emerged as promising alternatives, these methods are highly susceptible to noise and outliers commonly present in sensing applications. Furthermore, deep learning-based anomaly detection methods, despite their performance, are often criticized for their black-box nature, limiting their applicability in safety-critical and online environments where interpretability and explainability are paramount. In this work, we propose an unsupervised anomaly clustering method leveraging a cyclic alignment-based offset detection algorithm for multivariate time-series signals. The proposed method is applied to multivariate data collected from vibrational, voltage, and magnetic field sensors deployed in a local grid substation. Our results demonstrate the robustness of the algorithm in accurately clustering various anomalies/events across different sensing modalities. Additionally, we compare the effectiveness of the proposed approach against a simple pattern-based anomaly detection method, which performs well for univariate data but fails to generalize to multivariate and multimodal time-series data.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)↗

Modeling Flow and Particle Deposition in a Spent Nuclear Fuel Assembly

CFD (Computational Fluid Dynamic) simulation of aerosol-laden natural convective flow and particle deposition in a spent fuel storage canister with 37 assemblies is currently computationally prohibitive. PWR (Pressurized Water Reactor) assemblies have up to 289 pins or tubes with several spacer grids to align the pins. Spacer grids with mixing vanes induce swirling during operation to increase heat transfer. Each spacer grid contains hundreds of small structures such as retaining clips, channel walls, and openings. The largest canisters store 37 PWR assemblies thus, there are numerous pins, tubes, and spacer grids for which the flow region between and around these structures needs to be determined along with the movement and deposition of aerosol particles. Because of the complicated geometry, modeling the intricate flow even for just one assembly is currently impractical. Nonetheless, we are developing techniques for a practical model to assess the natural aerosol particle deposition process in a canister in the event that a release occurs from one or more fuel pins. In the previous work it was demonstrated that CFD can model the flow through a PWR spacer grid with mixing vanes, including particle deposition, in a reasonable amount of time on a personal computer. In this work, the analysis is extended to include the bypass region between an assembly and the canister basket walls. It is shown that the flow velocity in the bypass region is about three times that of the interstitial region between the pins. The lengths before and after the spacer grid are also extended to determine when the flow becomes fully developed. In addition, the approach of computationally “stitching together” segments of an assembly is demonstrated with the plan to ultimately model a full assembly. The fraction of particles that are deposited in a segment with a spacer grid is determined as a function of particle size and flow velocity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

End-Use Load Profiles for the U.S. Building Stock: Market Needs, Use Cases, and Data Gaps

States and utilities are developing increasingly ambitious energy goals. Part of the solution to meeting these goals is improving electric grid flexibility. This includes shifting electric demand to align with grid needs. Thus, identifying and using building energy efficiency and other distributed energy resources to produce the highest grid value requires highly resolved, accurate and accessible electricity end-use load profiles (EULPs). EULPs quantify how and when energy is used. Currently, few accurate and accessible end-use load profiles are available for utilities, public utility commissions, state energy offices and other stakeholders to use to prioritize investment and value energy efficiency, demand response, distributed generation and energy storage. High-quality EULPs are also critical for determining the time-sensitive value of efficiency and other distributed energy resources, and the widespread adoption of grid-interactive efficient buildings (GEBs).For example, EULPs can be used to accurately forecast energy savings in buildings or identify energy activities that can be shifted to different times of the day. This report serves as the first-year deliverable for a multiyear U.S. Department of Energy-funded project, End-Use Load Profiles for the U.S. Building Stock, that intends to produce a set of highly resolved EULPs of the U.S. residential and commercial building stock. The project team, made up of researchers from the National Renewable Energy Laboratory (NREL), Lawrence Berkeley National Laboratory (LBNL), and Argonne National Laboratory, ultimately will use calibrated physics-based building energy models to create these EULPs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

End-Use Load Profiles for the U.S. Building Stock: Market Needs, Use Cases, and Data Gaps

States and utilities are developing increasingly ambitious energy goals. Part of the solution to meeting these goals is improving electric grid flexibility. This includes shifting electric demand to align with grid needs. Thus, identifying and using building energy efficiency and other distributed energy resources to produce the highest grid value requires highly resolved, accurate and accessible electricity end-use load profiles (EULPs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aligning Electric Vehicle Customer Charging with Grid Needs

This talk to the National Association of Regulatory Utility Commissioners (NARUC) focuses on "Aligning Electric Vehicle Customer Charging with Grid Needs" to highlight the opportunities associated with managed electric vehicle charging and its value for consumers and the power system. Electric vehicles (EVs) are experiencing a rapid rise in popularity and adoption, and growing EV adoption offers an opportunity to increase electricity demand. With expected widespread EV adoption, supporting charging will require investments in generation, transmission, and distribution systems. Uncoordinated charging of EVs will lead to increased system peak load, possibly exceeding the maximum power that can be supported by distribution systems and generally increasing power system stress. However, vehicles are underutilized assets parked ~96% of the time: managed EV charging can satisfy mobility needs while also supporting the grid. EVs are not a burden for the grid, but a resource: The demand-side flexibility provided by managed EV charging offers significant potential benefits for the grid over multiple timescales and applications., especially for high-renewable systems. Managed charging can support power system planning and operations during normal and extreme conditions, benefitting EV owners and other electricity consumers. Managed charging is shown to consistently provide hundreds of dollars in cost savings per EV each year.

ADVANCED PROPULSION SYSTEMS↗

Optimizing Grid Regulation With Gravity Storage Systems: A Comparative Analysis With Different Motor Inertias

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid imbalances in generation and demand is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS scenarios provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 s from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS based on a high-inertia motor may be able to operate over a broader range of frequency variations, whereas a low-inertia system may be limited by thermal constraints of the motor.

frequency regulation↗

Optimizing Grid Regulation With Gravity Storage Systems: A Comparative Analysis With Different Motor Inertias: Preprint

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between the energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid generation-demand imbalances is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS systems provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 seconds from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS with a high-inertia motor may be able operate over a broader range of frequency variations whereas a low-inertia system may be limited by thermal constraints of the motor.

frequency regulation↗

Optimizing Grid Regulation with Gravity Energy Storage Systems: A Comparative Analysis with Different Motor Inertias

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid imbalances in generation and demand is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS scenarios provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 s from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS based on a highinertia motor may be able to operate over a broader range of frequency variations, whereas a low-inertia system may be limited by thermal constraints of the motor.

ENERGY STORAGE,POWER TRANSMISSION AND DISTRIBUTION↗

Self-Aligned Selective Area Front Contacts on Poly -Si/SiO x Passivating Contact c -Si Solar Cells

We report both polarity poly-Si/SiO x passivating contacts in a front/back device configuration may represent the next solar cell architecture after tunnel oxide passivating contacts (TOPCon) cells, but high parasitic absorption in the front poly -Si layer often limits its performance. This work explores a wet etching technique to remove the front poly -Si in the nonmetallized regions using self-aligned metal grids as an etch mask. We systematically examine various dielectric layers (SiN x ,Al 2 O 3 , and stacks thereof) to study the repassivation of the etched n + surface, and find that an SiN x /Al 2 O 3 passivation stack can effectively repassivate the etched surface, which we attribute to field-effect passivation from the positive fixed charge from the SiN x layer, and excellent chemical passivation property from Al 2 O 3 in the form of atomic H. We demonstrate a front/back poly-Si/SiO x passivating contact device, with an open-circuit voltage (V oc ) of 690 mV, short-circuit current density (J sc ) of 39.8 mA/cm 2 , fill factor of 78%, and power conversion efficiency of 21.4%. Furthermore, simulations using SunSolve and Quokka 3 show good agreement with both the optical and electrical properties of the experimental device. The power loss analysis reveals improvements in the optical loss from the back Ti adhesion and front SiN x layers would lead to a 23.5% device. Lastly, a techno-economic model compares the production cost of this improved cell with the current TOPCon cells. Our results highlight that further cost reductions in single-sided doped poly -Si layers are needed to compete with mainstream passivated emitter and rear cell, and TOPCon technologies.

14 SOLAR ENERGY↗

Effective Dielectric Passivation Scheme in Area-Selective Front/Back Poly-Si/SiOx Passivating Contact Solar Cells

Despite the high efficiencies reached by heavily doped poly-Si/SiO x passivating contact solar cells, challenges like the high front parasitic absorption still limit their performance. Previously, we showed a wet etching technique using self-aligned metal grids to remove the front poly-Si in the non-metallized region. Here, we focus on the effective dielectric passivation on this tunneling oxide/n + in-diffused region. The effect of poly-Si thickness was studied to balance between the passivation quality and the current gain. We then compared various dielectric passivation schemes using SiN x , Al 2 O 3 , and stacks thereof via injection-level dependent lifetime and the transfer length method. We demonstrate a SiN x /Al 2 O 3 stack yielded the best passivation performance within device process limitation and obtained an improved front/back poly-Si/SiO x passivating contact device, with a short circuit current density of 41.8 mA/cm 2 and an efficiency of 21.8%.

anisotropic wet etching↗

Modeling the Impact of Flexible CHP on the Future Electric Grid In California

Combined heat and power (CHP) systems provide electricity and process heat at more than 4,400 industrial and commercial facilities across the United States. Typically fueled with natural gas, a CHP system combines a prime mover (such as a reciprocating engine) with a generator and heat recovery equipment, allowing operation at very high efficiencies (65–85%). Traditionally, CHP systems have been configured to serve local electrical and thermal loads at the sites where they are deployed. Units are sized to ensure a high capacity factor for the equipment, and the electricity generated tends to be used on site. CHP units in the United States already generate over 12% of the nation’s electricity. However, CHP’s potential benefits could be much greater if power generated could be used beyond the site, because the analysis was performed under the assumption that sites could use all the thermal output. Analysis of a few key sectors confirmed that this assumption is valid (for more information, see Appendix E). Those benefits could include improved grid reliability and resilience, as well as lower-cost options for providing energy and other grid services. The potential benefits also align well with grid modernization objectives, as shown in Combined heat and power (CHP) systems provide electricity and process heat at more than 4,400 industrial and commercial facilities across the United States., and greater electrification of loads, driven by carbon reduction priorities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Deliberate Design: Creating Electricity Rates with Purpose

Today’s electricity rates often are legacy designs that do not reflect the dynamics of an evolving power grid or align with current policy objectives. Four steps will assist utilities, regulators, and industry stakeholders in modernizing outdated electricity rate designs. 1. Understand the context for rate design change: The power system is changing at a pace that the industry has not experienced for decades. It is essential to understand the implications of these changes so rates can evolve to remain consistent with changes to the underlying cost profile, customer preferences, and power system requirements. 2. Establish ratemaking objectives: Rates can do more than recover utility costs. They can be a tool for promoting desired outcomes such as improved energy affordability, flexible and efficient electricity consumption, or promoting technology adoption. First, these objectives must be clearly defined and prioritized. 3. Account for tradeoffs when designing new rates: Rate design is the art of balancing tradeoffs. It is essential to understand these tradeoffs when designing new rates, particularly if the rates are being used as a tool for accomplishing policy objectives that extend beyond the basic goal of cost reflectivity. 4. Transition to the new rates with a plan: The move to well-designed rates requires a transition plan. This will ensure that rate design changes do not happen in isolation and are consistent with a long-term, holistic vision. The report, published as an interactive web tool for which the content can be separately downloaded as a standalone document, is intended to allow state energy regulators, utility rates staff, and other industry stakeholders with an interest in rate design to selectively “drill down” on content that is relevant to their interests and situation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Commercial and Residential Hourly Load Profiles for All Typical Meteorological Year 3 (TMY3) Locations in the United States

One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, it is critical to understand how and when energy is used. High-quality end-use load profiles (EULPs) provide this information and can help cities, states, and utilities understand the time-sensitive value of energy efficiency, demand response, and distributed energy resources. Publicly available EULPs have traditionally had limited application because of age and incomplete geographic representation. To help fill this gap, the U.S. Department of Energy funded a 3-year project, End-Use Load Profiles for the U.S. Building Stock, that culminated in this publicly available dataset of calibrated and validated 15-minute-resolution load profiles for all major residential and commercial building types and end uses across all climate regions in the United States. These EULPs were created by calibrating the ResStock and ComStock physics-based building stock models using many different measured datasets, as described in the "Technical Report Documenting Methodology" linked in the submission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗