Search NASA⌕ Search

SEARCH · Search NASA

Results for “groundwater pumping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Identifying hydrologic signatures associated with streamflow depletion caused by groundwater pumping

Abstract Groundwater pumping can reduce streamflow in nearby waterways (‘streamflow depletion’), a process which must be accounted for in integrated management of surface and groundwater resources. However, causal identification of streamflow depletion from hydrographs alone is challenging because pumping impacts are masked by other drivers of hydrologic variability. To identify potential indicators of streamflow depletion, we used synthetic hydrographs and an analytical streamflow depletion model to assess potential pumping impacts on specific hydrograph characteristics (‘hydrologic signatures’) for 215 streamgages spanning the conterminous United States (CONUS). We found that streamflow depletion commonly impacts signatures associated with seasonal and annual low flows and low flow recessions. The largest impacts occurred during dry years, suggesting streamflow depletion may be evident in dry years even where impacts are unmeasurable in wet years. Random forest models indicated that streamflow depletion could significantly impact Annual, Summer, and Fall signatures in most streams. Our finding that multiple hydrologic signatures are consistently responsive to streamflow depletion across CONUS suggests that the underlying hydrological processes linking pumping to streamflow reductions are consistent across diverse settings, information that will aid in identifying indicators of streamflow depletion from streamflow hydrographs.

Lapides, Dana A.↗

Effects of groundwater pumping on ground surface temperature: A regional modeling study in the North China Plain

Over-exploitation of groundwater (GW) in the North China Plain (NCP) since the 1960s has many environmental consequences. However, understanding of the dominant mechanisms remains limited, particularly at regional scale. In this study, the coupled ParFlow.CLM model representing subsurface and land-surface processes and their interactions was applied in the NCP at high spatio-temporal resolutions. The model was validated using the water and energy fluxes reported in previous studies and from the JRA-55 reanalysis. Numerical experiments were designed to examine the relative impacts of GW pumping and irrigation on the ground surface temperature (GST). Results show significant effects of GW pumping on GST in the NCP. Generally, the subsurface acts as a buffer to temporal variations in heat fluxes at the land-surface, but long-term pumping can gradually weaken this buffer, resulting in increases in the spatio-temporal variability of GST, as exemplified by hotter summers and colder winters. Considering that changes of water table depth (WTD) can significantly affect land surface heat fluxes when WTD ranges roughly between 0.01–10 m, the 0.5 m/year increase of WTD simulated by the model due to pumping can continue to increase the average WTD and hence, disturb GST, for about 20 years from the pre-pumping WTD in the NCP, before the WTD exceeds 10 m. The variations of GST are expected to be faster initially and gradually slow down due to the nonlinear behaviors of GST with WTD. The findings from this study in the NCP may also have implications for other regions with GW depletion.

Yang, Chen↗

Impact of excessive groundwater pumping on rejuvenation processes in the Bandung basin (Indonesia) as determined by hydrogeochemistry and modeling

In the Bandung basin, Indonesia, excessive groundwater pumping caused by rapid increases in industrialization and population growth has caused subsurface environmental problems, such as excessive groundwater drawdown and land subsidence. In this study, multiple hydrogeochemical techniques and numerical modeling have been applied to evaluate the recharge processes and groundwater age (rejuvenation). Although all the groundwater in the Bandung basin is recharged at the same elevation at the periphery of the basin, the water type and residence time of the shallow and deep groundwater could be clearly differentiated. However, there was significant groundwater drawdown in all the depression areas and there is evidence of groundwater mixing between the shallow and deep groundwater. The groundwater mixing was traced from the high dichlorodifluoromethane (CFC-12) concentrations in some deep groundwater samples and by estimating the rejuvenation ratio (R) in some representative observation wells. The magnitude of CFC-12 concentration, as an indicator of young groundwater, showed a good correlation with R, determined using {sup 14}C activity in samples taken between 2008 and 2012. These correlations were confirmed with the estimation of vertical downward flux from shallower to deeper aquifers using numerical modeling. Furthermore, the change in vertical flux is affected by the change in groundwater pumping. Since the 1970s, the vertical flux increased significantly and reached approximately 15% of the total pumping amount during the 2000s, as it compensated the groundwater pumping. This study clearly revealed the processes of groundwater impact caused by excessive groundwater pumping using a combination of hydrogeochemical methods and modeling.

58 GEOSCIENCES↗

Impacts of Groundwater Pumping on Regional and Global Water Resources

Except frozen water in ice and glaciers (68%), groundwater is the world's largest distributed store of freshwater (30%), and has strategic importance to global food and water security. In this chapter, the most recent advances assessing human impact on regional and global groundwater resources are reviewed. This chapter critically evaluates the recently advanced modeling approaches quantifying the effect of groundwater pumping in regional and global groundwater resources and the evidence of feedback to the Earth system including sea‐level rise associated with groundwater use. At last, critical challenges and opportunities are identified in the use of groundwater to adapt to growing food demand and uncertain climate.

groundwater↗

Groundwater Pump and Treat System Optimization Report U.S. DOE NNSA Pantex Plant, Texas

This document details the approach and presents the results for the optimization of the perched groundwater pump and treat (P&T) systems at the Pantex Plant, located in the Texas panhandle (Figure 1.1). Recommendations from the second Five-Year Review (FYR) for the Pantex Plant (HGL, 2018) and objectives specified in the 2007 Record of Decision (ROD) are the basis of the optimization effort.

54 ENVIRONMENTAL SCIENCES↗

Factors governing sustainable groundwater pumping near a river

The objective of this paper is to provide new insights into processes affecting riverbank filtration (RBF). We consider a system with an inflatable dam installed for enhancing water production from downstream collector wells. Using a numerical model, we investigate the impact of groundwater pumping and dam operation on the hydrodynamics in the aquifer and water production. We focus our study on two processes that potentially limit water production of an RBF system: the development of an unsaturated zone and riverbed clogging. We quantify river clogging by calibrating a time-dependent riverbed permeability function based on knowledge of pumping rate, river stage, and temperature. The dynamics of the estimated riverbed permeability reflects clogging and scouring mechanisms. Our results indicate that (1) riverbed permeability is the dominant factor affecting infiltration needed for sustainable RBF production; (2) dam operation can influence pumping efficiency and prevent the development of an unsaturated zone beneath the riverbed only under conditions of sufficient riverbed permeability; (3) slow river velocity, caused by dam raising during summer months, may lead to sedimentation and deposition of fine-grained material within the riverbed, which may clog the riverbed, limiting recharge to the collector wells and contributing to the development of an unsaturated zone beneath the riverbed; and (4) higher river flow velocities, caused by dam lowering during winter storms, scour the riverbed an thus increase its permeability. These insights can be used as the basis for developing sustainable water management of a RBF system.

54 ENVIRONMENTAL SCIENCES↗

Combining a land surface model with groundwater model calibration to assess the impacts of groundwater pumping in a mountainous desert basin

The quantification of recharge and trans-valley underflow is needed in arid regions to estimate the impacts of new water withdrawals on the water table. However, for mountainous desert areas, such estimates are highly challenging, due to data scarcity, heterogeneous soils, and long residence times. Conventional assessment employs isolated groundwater models configured with simplified uniform estimates of recharge. Here, we employed a data-constrained surface-subsurface process model to provide an ensemble of spatially distributed recharge and underflow estimates using perturbed parameters. Then, the Model-Independent Parameter Estimation and Uncertainty Quantification (PEST) package was used to calibrate the aquifer hydraulic conductivity field in MODFLOW for this ensemble and reject implausible recharge values. This novel dual-model approach, broadly applicable to mountainous arid regions, was designed to maximally exploit available data sources. It can assimilate groundwater head observations, reject unrealistic parameters, and narrow the range of estimated drawdowns due to pumping. We applied this approach to the Chuckwalla basin in California, USA to determine natural recharge. Simulated recharge concentrates along alluvial fans at the mountain fronts and ephemeral washes where run-off water infiltrates. If an evenly distributed recharge was employed as in conventional studies, it would result in regional biases in estimated drawdown and larger uncertainty bounds. Here, we also note that the speed of groundwater recovery does not guarantee sustainability: heavy pumping induces large hydraulic gradients that initially recover quickly when pumping is halted, but the system may not ultimately recover to pre-pumping levels.

54 ENVIRONMENTAL SCIENCES↗

Managing an Aging Pump-and-Treat Groundwater Remediation System at the Fernald Preserve - 19557

The Fernald Preserve, Ohio, Site underwent restoration and remediation under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). With the exception of the Great Miami Aquifer, the CERCLA remediation was declared physically complete on October 29, 2006, and the site was turned over to the US Department of Energy Office of Legacy Management for long-term care and maintenance. The Record of Decision under CERCLA specifies a concentration-based cleanup that requires the extraction and treatment of Great Miami Aquifer groundwater above Final Remediation Levels (FRLs) until the full, beneficial use potential of the aquifer is achieved, including use as a drinking water source. The area of the aquifer targeted for remediation is 126.5 hectares (312.70 acres). The groundwater pumping remediation was designed by modeling cleanup with the Variable Saturated Analysis Model in 3 Dimensions (VAM-3D) modeling code, developed by Hydrogeologic Inc. The original design called for 23 extraction wells operating at 379 liters per minute (lpm) (100 gallons per minute [gpm]) to 1135 lpm (300 gpm) each for a system total of 18,073 lpm (4775 gpm). In 2014, the system was optimized down to 20 extraction wells operating at 379 to 1893 lpm each for a system total of 19,180 lpm (5075 gpm). To date, pumping has been an effective remediation technology for the aquifer. At the end of 2017, the area of the aquifer remaining above FRLs was down to 38.2 hectares (94.4 acres). From August 1993 through December 2017 (24 years), 6235 kilograms (kg) (13,733 pounds) of uranium were removed from the aquifer by the pumping of 1.74 x 10{sup 11} liters (46.2 billion gallons) of water. Since 2010, treatment of groundwater to achieve regulatory discharge limits at the Great Miami River has not been needed on a routine basis. The ongoing remediation is now essentially a pumping operation, and this water does not require treatment. Metrics reported in the annual Site Environmental Report for the groundwater remediation indicate that, based on the model-predicted estimate of the mass of uranium that needs to be removed from the aquifer to achieve a concentration-based cleanup, the cleanup is approximately 86% - 87% complete. Current model predictions indicate that pumping will need to continue an additional 16 years (until 2035) in some of the wells. During the additional 16 years, it is estimated that approximately 1012 kg (2231 pounds) of uranium will be removed from the aquifer. System pumping rates are designed to decrease over the course of the remaining 16 years, dropping down to a system total of 11,638 lpm (3075 gpm) in 2022 and a system total of 4163 lpm (1100 gpm) in 2033. Even with the designed decreases in pumping rates, it is estimated that approximately 1 x 10{sup 11} liters (26.6 billion gallons) of water will be pumped from the aquifer to remove 1012 kg (2231 pounds) of uranium. This indicates that the remaining 16 years of operation will be much less efficient than the first 24 years. Decreasing efficiency is common for pumping operations. The worst-case scenario is that decreasing concentration trends stabilize above the cleanup FRLs and remediation goals are never achieved. Performance assessments of the pumping remedy will need to be routinely conducted to determine if pumping should be discontinued, if it should be continued but optimized, or if the pumping technology can be supplemented with a different technology that will improve the outcome of the remediation and make the operation more efficient and successful. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Relative Contribution of Monsoon Precipitation and Pumping to Changes in Groundwater Storage in India

The depletion of groundwater resources threatens food and water security in India. However, the relative influence of groundwater pumping and climate variability on groundwater availability and storage remains unclear. Here we show from analyses of satellite and local well data spanning the past decade that long-term changes in monsoon precipitation are driving groundwater storage variability in most parts of India either directly by changing recharge or indirectly by changing abstraction. We find that groundwater storage has declined in northern India at the rate of 2 cm/yr and increased by 1 to 2 cm/yr in southern India between 2002 and 2013. We find that a large fraction of the total variability in groundwater storage in north-central and southern India can be explained by changes in precipitation. Groundwater storage variability in northwestern India can be explained predominantly by variability in abstraction for irrigation, which is in turn influenced by changes in precipitation. Declining precipitation in northern India is linked to Indian Ocean warming, suggesting a previously unrecognized teleconnection between ocean temperatures and groundwater storage.

Climate-change impacts↗

Groundwater Remediation with Pump-and-Treat Technology

Pump-and-treat (P&T) is a widely used remediation technology that involves pumping groundwater from extraction wells in the subsurface, removing contaminants of concern from the groundwater in an aboveground treatment system, reintroducing treated water into the environment – often by injection back into the groundwater aquifer or by discharge to the surface–, and groundwater monitoring to evaluate performance. In this chapter we explore how the Hanford Site uses the P&T remediation approach to treat contaminated groundwater. Six P&T facilities currently operate at the Hanford Site; however, this chapter uses the 100 Area DX and HX P&T facilities' treatment of hexavalent chromium as a case study to discuss this remediation approach. Located in the River Corridor, HX and DX P&T facilities are much closer to reaching closure than the younger 200W P&T facility located in the Central Plateau’s 200W Area. As such, one can follow the historical design, operation, and optimization steps that have led these facilities closer to closure.

Saslow, Sarah A.↗

Assessing the Thermal Environmental Impacts of an Groundwater Heat Pump in Southeastern Washington State

A thermal analysis of a large-scale (e.g., 1900 gpm), open-loop ground source heat pump (GSHP) installed on the Pacific Northwest National Laboratory (PNNL) campus in southeastern Washington State has been performed using a numerical modeling approach. Water temperature increases at the upgradient extraction wells in the system and at the downgradient Columbia River are potential concerns, especially since heat rejection to the subsurface will occur year-round. Hence, thermal impacts of the open-loop GSHP were investigated to identify operational scenarios that minimized downgradient environmental impacts at the river, and upgradient temperature drift at the production wells. Simulations examined the sensitivity of the system to variations in pumping rates and injected water temperatures, as well as to hydraulic conductivity estimates of the aquifer. Results demonstrated that both downgradient and upgradient thermal impacts were more sensitive to injection flow rates than estimates of hydraulic conductivity. Higher injection rates at lower temperatures resulted in higher temperature increases at the extraction wells but lower increases at the river. Conversely, lower pumping rates and higher injected water temperatures resulted in a smaller temperature increase at the extraction wells, but higher increases at the river. The scenario with lower pumping rates is operationally more efficient, but does increase the likelihood of a thermal plume discharging into the Columbia River. However, this impact would be mitigated by mixing within the hyporheic zone and the Columbia River. The impact under current operational conditions is negligible, but future increases in heat rejection could require a compromise between maximizing operational efficiency and minimizing temperature increases at the shoreline.

15 GEOTHERMAL ENERGY↗

Lessons Learned From The 200 West Pump And Treatment Facility Construction Project At The US DOE Hanford Site - A Leadership For Energy And Environmental Design (LEED) Gold-Certified Facility

CH2M Hill Plateau Remediation Company (CHPRC) designed, constructed, commissioned, and began operation of the largest groundwater pump and treatment facility in the U.S. Department of Energy's (DOE) nationwide complex. This one-of-a-kind groundwater pump and treatment facility, located at the Hanford Nuclear Reservation Site (Hanford Site) in Washington State, was built in an accelerated manner with American Recovery and Reinvestment Act (ARRA) funds and has attained Leadership in Energy and Environmental Design (LEED) GOLD certification, which makes it the first non-administrative building in the DOE Office of Environmental Management complex to earn such an award. There were many contractual, technical, configuration management, quality, safety, and LEED challenges associated with the design, procurement, construction, and commissioning of this $95 million, 52,000 ft groundwater pump and treatment facility. This paper will present the Project and LEED accomplishments, as well as Lessons Learned by CHPRC when additional ARRA funds were used to accelerate design, procurement, construction, and commissioning of the 200 West Groundwater Pump and Treatment (2W P&T) Facility to meet DOE's mission of treating contaminated groundwater at the Hanford Site with a new facility by June 28, 2012.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Systematic Application of Flow-and-Transport Modeling for Wellfield Design: the Hanford 200-ZP-1 Groundwater Pump-and-Treat Remedy - 10320

During 2007 a Feasibility Study and Proposed Plan were completed that describe the selection of a combined groundwater pump-and-treat, monitored natural attenuation, and flow-path-control remedy for contaminants present in the Hanford 200-ZP-1 groundwater operable unit. In anticipation of the September 2008 signing of the final record of decision, work began on the development of a groundwater flow and contaminant transport model encompassing the 200-ZP-1 OU. The model was developed to support the preparation of the remedial design/remedial action work plan and subsequent design documents; to provide estimates of influent concentrations and mass removal rates for several contaminants of concern, including carbon tetrachloride, technetium-99, and hexavalent chromium; and to assist in the integration of remedial decision making across the Hanford Central Plateau. This paper describes the initial development and application of the flow and transport model, through Spring 2009.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Overpumping leads to California groundwater arsenic threat

Water resources are being challenged to meet domestic, agricultural, and industrial needs. To complement finite surface water supplies that are being stressed by changes in precipitation and increased demand, groundwater is increasingly being used. Sustaining groundwater use requires considering both water quantity and quality. A unique challenge for groundwater use, as compared with surface water, is the presence of naturally occurring contaminants within aquifer sediments, which can enter the water supply. Here we find that recent groundwater pumping, observed through land subsidence, results in an increase in aquifer arsenic concentrations in the San Joaquin Valley of California. By comparison, historic groundwater pumping shows no link to current groundwater arsenic concentrations. Our results support the premise that arsenic can reside within pore water of clay strata within aquifers and is released due to overpumping. We provide a quantitative model for using subsidence as an indicator of arsenic concentrations correlated with groundwater pumping.

54 ENVIRONMENTAL SCIENCES↗

Lessons Learned from the 200 West Pump and Treatment Facility Construction Project at the US DOE Hanford Site - A Leadership for Energy and Environmental Design (LEED) Gold-Certified Facility

CH2M Hill Plateau Remediation Company (CHPRC) designed, constructed, commissioned, and began operation of the largest groundwater pump and treatment facility in the U.S. Department of Energy’s (DOE) nationwide complex. This one-of-a-kind groundwater pump and treatment facility, located at the Hanford Nuclear Reservation Site (Hanford Site) in Washington State, was built to an accelerated schedule with American Recovery and Reinvestment Act (ARRA) funds. There were many contractual, technical, configuration management, quality, safety, and Leadership in Energy and Environmental Design (LEED) challenges associated with the design, procurement, construction, and commissioning of this $95 million, 52,000 ft groundwater pump and treatment facility to meet DOE’s mission objective of treating contaminated groundwater at the Hanford Site with a new facility by June 28, 2012. The project team’s successful integration of the project’s core values and green energy technology throughout design, procurement, construction, and start-up of this complex, first-of-its-kind Bio Process facility resulted in successful achievement of DOE’s mission objective, as well as attainment of LEED GOLD certification, which makes this Bio Process facility the first non-administrative building in the DOE Office of Environmental Management complex to earn such an award.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of Temporary Shutdown Testing and Groundwater Pump-Testing at Agra, Kansas, February-September 2016 and march 2017, and Assessment of Groundwater and Contaminant Migration

In 2005, the Commodity Credit Corporation/U.S. Department of Agriculture (CCC/USDA) conducted a comprehensive investigation of potential contaminant source areas on, and in the vicinity of, the former CCC/USDA grain storage facility in Agra, Kansas (Argonne 2006). The data collected during this investigation identified three primary source areas for carbon tetrachloride contamination. One source is located on the former CCC/USDA property, and the other two (western and eastern) sources are located on adjacent property owned by Pro-Ag Marketing. The soil source located at the western end of the Pro-Ag property has been identified as the sole source of carbon tetrachloride contamination to the groundwater in this portion of the Agra site, and is not associated with any grain storage activities on the former CCC/USDA property. In 2008-2009, to address the carbon tetrachloride contamination detected on its former property, the CCC/USDA initiated source area cleanup as an interim measure (IM). The cleanup employs five large-diameter boreholes (LDBs) that were excavated by auger drilling. The purposes of these borings were to (1) physically remove soils impacted by carbon tetrachloride from the most contaminated area for treatment by onsite land farming and (2) provide locations for the installation of coupled soil vapor extraction (SVE) and air sparging (AS) wells to facilitate in-situ treatment of the carbon tetrachloride in the soils and underlying groundwater. With the approval of the KDHE, operation of the SVE/AS systems began in May 2009, and has generally continued with minimal interruption since that time. Land farming operations to treat contaminated soil excavated from the LDBs were successfully completed in October 2010.

54 ENVIRONMENTAL SCIENCES↗

Lessons Learned from the 200 West Pump and Treatment Facility Construction Project at the US DOE Hanford Site - A Leadership for Energy and Environmental Design (LEED) Gold-Certified Facility - 13113

CH2M Hill Plateau Remediation Company (CHPRC) designed, constructed, commissioned, and began operation of the largest groundwater pump and treatment facility in the U.S. Department of Energy's (DOE) nationwide complex. This one-of-a-kind groundwater pump and treatment facility, located at the Hanford Nuclear Reservation Site (Hanford Site) in Washington State, was built to an accelerated schedule with American Recovery and Reinvestment Act (ARRA) funds. There were many contractual, technical, configuration management, quality, safety, and Leadership in Energy and Environmental Design (LEED) challenges associated with the design, procurement, construction, and commissioning of this $95 million, 52,000 ft groundwater pump and treatment facility to meet DOE's mission objective of treating contaminated groundwater at the Hanford Site with a new facility by June 28, 2012. The project team's successful integration of the project's core values and green energy technology throughout design, procurement, construction, and start-up of this complex, first-of-its-kind Bio Process facility resulted in successful achievement of DOE's mission objective, as well as attainment of LEED GOLD certification (Figure 1), which makes this Bio Process facility the first non-administrative building in the DOE Office of Environmental Management complex to earn such an award. (authors)

54 ENVIRONMENTAL SCIENCES↗

Sub-drain Water Treatment Facility for Reduction of Accumulated Waste Water Amount at the Fukushima NPS Site - 17572

At the Fukushima Daiichi Nuclear Power Station site, water treatment facility special for sub-drain and groundwater drain has been constructed by Tokyo Electric Power Company Holdings, Inc. and Hitachi-GE Nuclear Energy, Ltd., and it has been operated to remove radionuclides from the pumped groundwater. The facility consists of three kinds of equipment for collecting, purifying and transferring. The purification equipment removes radionuclides contained in the pumped groundwater. The purification equipment consists of filters for removal of solids and colloidal particles, and adsorbents for removal of ionic radionuclides. Five adsorption vessels are installed into the equipment; three vessels have adsorbent to remove Cs and Sr simultaneously, the fourth vessel has adsorbent to remove Sb and for the last has adsorbent to remove heavy metals. The vessels for Cs and Sr are operating as a so-called 'merry-go-round'. For the rational operation of the equipment, a simulation code has been developed to calculate the Sr concentration of outlet water which determines the replacement timings of the Cs-Sr adsorption vessels. The simulation code has been applied to planning of vessel replacement during the water treatment facility operation. The facility started operation in September 2015, and treated the pumped groundwater since then. As of October 2016, about 211,000 m{sup 3} of groundwater had been treated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗