Experience with CPV Module Failures at NREL (Presentation)
The failures and performance issues associated with three years of on-sun testing of CPV modules are discussed. Pictures of various failure mechanisms and performance issues are presented.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
The failures and performance issues associated with three years of on-sun testing of CPV modules are discussed. Pictures of various failure mechanisms and performance issues are presented.
This work experimentally investigates hail-related failures in Glass/Backsheet and Glass/Glass PV modules with varying ice ball diameters and velocities.
This workshop presentation proposes the development of solar photovoltaic (PV) system resilience metrics and a methodology and framework for evaluation of PV resilience metrics. PV resilience metrics are needed to establish a consistent basis for reporting, evaluation, and data collection by industry, evaluate performance of PV systems that have been subject to natural hazards, correlating resilience to system attributes, and predicting resilience for any PV system. PV resilience metrics can guide improved system design, standards, and insurance coverage. Establishing consistent metrics can foster data collection on impacts of natural hazards on PV systems.
Abstract not provided
Poster presenting a new Duramat project that will develop a science-based definition of a "50-year solar panel" by combining reliability data, climate risks, design choices, and long-term cost analysis. The work aims to clarify what is needed to enable longer-lasting, high-value solar systems.
This paper provides statistical analysis of the characteristics of power system outages to gain a better understanding of the impacts of the increasing severe weather conditions on the outages. 10-year historical power system outage data from the Bonneville Power Administration (BPA) were gathered together with co-located weather attributes and recorded extreme weather events in the service area, which are paired in comparable spatial and temporal scales, with a focus on each outage transmission line. Statistical frequency analysis and cross-tabular evaluation are performed to investigate the occurring frequency and duration of outages associated with extreme weather in this area of study. The study reveals that the weather-related outages can be mainly attributed to hail and thunderstorm events which correspond to up to 60% out of all failures in several transmission line types.
Emerging mobility services (e.g. ride-hailing, e-commerce, micro-mobility, etc.), are generating novel and rapidly growing demands to use curbside space, with potentially large impacts on mobility, energy consumption, and related outcomes. This presents both opportunities and challenges to municipal agencies responsible for managing this interface between the road network and adjacent land uses, as legacy practices require updating. In this study, we employ a semi-structured interviewing approach to establish how municipalities are adapting to these new pressures on their curbside. We interviewed senior staff responsible for curbside policy of ten large U.S. municipalities, with populations ranging from ~250,000 to ~5,000,000 (and the majority of which are the central city of their metropolitan region). We document a trend of organizational restructuring to more formally include curbside management teams, with the majority of interviewees also reporting increased staffing. Respondents reported that operational failures at their curbside (e.g. demand in excess of capacity) have impacts on safety, capacity, and emergency vehicle mobility, with impacts highly concentrated spatially and temporally (e.g. late evenings in nightlife districts). We document a diversity of data flows between ride-hailing operators (e.g. Uber, Lyft) and municipalities, with some cities reporting obtaining types of data that other cities report not receiving, despite requesting such data. Finally, respondents consistently expressed a desire for new data streams and methodologies to help manage the curbside of the future. It is hoped that establishing the state of practice in this rapidly changing context will be of use to practitioners facing similar pressures as those of our interviewees.
This initiative is a multi-faceted project at the National Laboratory of the Rockies (NLR) aimed at strengthening its Concentrating Solar Power (CSP) Optical Facilities to advance the development of low-cost, high-performance materials for solar and other applications. The project's strategy is built on three pillars: strategic stakeholder engagement, diligent facility maintenance and utilization, and the development of new research capabilities. The overarching goal is to ensure the facilities remain state-of-the-art resources for industry and academia, thereby accelerating the conversion of concentrated sunlight into energy. A key driver of the project is an international Advisory Board, which provides critical guidance on research priorities and industry needs, leading to new collaborations and secured funding. This external engagement, combined with proactive outreach to industry partners, ensures the lab's work remains aligned with real-world challenges, including materials durability and performance certification. Significant efforts in facility maintenance have addressed challenges with aging infrastructure. Notable achievements include the complete refurbishment of the hail-damaged Ultra-Accelerated Weathering System (UAWS) and the successful replacement of a failing 15-year-old Lambda 1050 spectrophotometer with a new-generation model, substantially upgrading material characterization capabilities. These maintenance activities were complemented by achieving a prestigious ISO 9001:2015 certification for the Advanced Optical Materials Labs, formally recognizing the quality and reliability of NLR's measurement capabilities. Despite these successes, challenges remain, including high demand for the High Flux Solar Furnace (HFSF) and intermittent failures of other key instruments. The project has delivered major advancements in research techniques and capabilities. At the Flatirons campus, a new indoor laboratory, was established to house advanced deflectometry and photogrammetry systems for heliostat characterization. For on-sun testing, a novel, actively cooled turning mirror was developed for the HFSF, enabling more realistic testing of particle receivers and components. A collaboration with Virginia Tech successfully demonstrated the high-temperature durability of a new solar absorber coating through extensive cyclic testing. Concurrently, new modeling took place to better predict material degradation on rough, fractal surfaces. In summary, this project has systematically enhanced NLR's CSP Optical Facilities through strategic upgrades, rigorous maintenance, and stakeholder-guided research. By overcoming equipment failures, budgetary constraints, and logistical hurdles, the project has reinforced NLR's role as a central hub for CSP innovation and materials testing. Future work will focus on securing diverse funding, expanding collaborations, and continuing to provide the critical infrastructure needed to accelerate the development and deployment of next-generation technologies.
Wind turbine blade leading-edge erosion (LEE) is a cause of increased operation and maintenance costs and decreased annual energy production. Thus, detailed, site-specific quantification of likely erosion conditions are critically needed to inform wind plant owner/operator decisions regarding mitigation strategies. Estimating the damage potential at a wind plant site requires accurate measurement of precipitation intensity, phase, droplet size distributions, wind speeds and their joint statistics. The current work quantifies the effect of disdrometer type on the characterization of LEE potential at a site in the US Southern Great Plains. using observations from three co-located disdrometers (an optical, an impact and a video disdrometer), along with hub-height wind-speed observations from a Doppler lidar and two LEE models: a kinetic energy model and the Springer model. Estimates of total kinetic energy of hydrometeor impacts over the four-year study period vary by as much as 38%, and coating lifetime derived from accumulated distance-to-failure estimates from the Springer model differ by an even greater amount, depending on disdrometer type. Damage potential at this site is concentrated in time, with 50% of impact kinetic energy occurring in 6–12 h per year, depending on which set of disdrometer observations is used. Rotor-speed curtailment during the most erosive 0.1–0.2% of 10 min periods is found to increase blade lifetimes and lead to the lowest levelized cost of energy.