Search NASA⌕ Search

SEARCH · Search NASA

Results for “hall effect transducers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A free-trailing vane flow direction indicator employing a linear output Hall effect transducer

The Hall effect vane (HEV) was developed to measure flow angularity in the NASA 40-by-80-foot and 80-by-120-foot wind tunnels. This indicator is capable of sensing flow direction at air speeds from 5 to 300 knots and over a + or - 40 deg angle range with a resolution of 0.1 deg. A free-trailing vane configuration employing a linear output Hall effect transducer as a shaft angle resolver was used. The current configuration of the HEV is designed primarily for wind tunnel calibration testing; however, other potential applications include atmospheric, flight or ground research testing. The HEV met initial design requirements.

Zell, Peter T.↗

Measuring Fan-Blade-Tip Displacements

Magnets and Hall-effect transducers used to monitor tip-to-shroud clearances. Mounting permanent magnet in end of fan blade and monitoring tip-to-shroud distance by use of output of Hall-effect transducers affixed to surface of shroud. Transducers provide real-time information. By placing magnets in each fan-blade tip, complete set monitored sequentially as each blade rotates past sensor. Application in many rotating machines, providing surrounding materials nonmagnetic and temperatures not severe.

Berry, Robert F., Jr.↗

Noncontacting valve-position indicator

Position of sealed valve or other movable part is indicated without penetrating housing. Flux from magnets connected to stem of hydraulic valve penetrates pressure wall and is sensed by Hall-effect transducer outside wall. When valve closes, moving stem and magnets, voltage from transducer decreases; thus, stem position is indicated without physical contact.

Crovella, E. A.↗

Flow direction measurement criteria and techniques planned for the 40- by 80-/80- x 120-foot wind tunnel integrated systems tests

A study was performed in order to develop the criteria for the selection of flow direction indicators for use in the Integrated Systems Tests (ISTs) of the 40 by 80/80 by 120 Foot Wind Tunnel System. The problems, requirements, and limitations of flow direction measurement in the wind tunnel were investigated. The locations and types of flow direction measurements planned in the facility were discussed. A review of current methods of flow direction measurement was made and the most suitable technique for each location was chosen. A flow direction vane for each location was chosen. A flow direction vane that employs a Hall Effect Transducer was then developed and evaluated for application during the ISTs.

Zell, P. T.↗

Software Architecture and Hardware Organization in Mu2e Solenoid Field Mapping System

Herein, the Mu2e field mapping system is designed to produce high accuracy field maps of the detector solenoid used in the experiment. The data acquisition system is mobile and uses a self-propelled mapper with rotating arms equipped with 3D Hall probes. The measurements require not only accurate magnetic field readouts, but also accurate locations of all Hall probes while measuring data. The latter is accomplished by using the laser tracker to measure positions of several retroreflectors on the field mapper during data acquisition. The measurement process requires scanning the whole space inside the large solenoid and takes many hours to complete, which necessitates its full automation. The automation software includes control of the mapper, readout of Hall and NMR probes and control of a laser tracker, including prediction of retroreflector positions and execution of quality control checks. The software architecture and data acquisition hardware of the field mapping system are described, with special attention given to control of the laser tracker and its integration with the rest of the system.

3d hall probes↗

Magnetic-field measurements for the Lewis Research Center cyclotron

The magnetic field of the Lewis Center cyclotron was mapped by using a Hall-effect magnetic-field transducer. Main-field Fourier coefficients were determined on a polar mesh of 40 radii for each of seven levels of main-field coil current. Incremental fields for eight sets of trim coils and two sets of harmonic coils were also determined at four of these main-field levels. A stored-program, digital computer was used to perform the measurements. The process was entirely automatic; all data-taking and data-reduction activities were specified by the computer programs. A new method for temperature compensation of a Hall element was used. This method required no temperature control of the element. Measurements of the Hall voltage and Hall-element resistance were sufficient to correct for temperature effects.

Fessler, T. E.↗

Acoustoelectric drag current in vanadium oxide films

Two different Mott insulator wires, vanadium dioxide and vanadium sesquioxide, were prepared on the piezoelectric LiNbO 3 substrates. Coupling of acoustic waves propagating in LiNbO 3 with free carriers in vanadium oxide gives rise to the acoustoelectric effect that manifests itself as the generation of direct electric current by the acoustic wave. According to a phenomenological model, the value of the effect strongly depends on the wires conductivity, which, for the vanadium-oxide films, changes by a few orders of magnitude. We demonstrated that this yields a significant enhancement of the direct current (DC) current generated in the wires at the metal–insulator transition temperatures. The sign of the generated DC voltage is different for excitations by surface and bulk acoustic wave modes, which may happen due to reverse wave propagation at the substrate surface. For each resonance mode, polarities of the generated DC signal are the same in both wires, despite the signs of charge carriers being different for these materials. It was shown that two complementary techniques (acoustoelectric and Hall effect measurements) yield opposite signs of charge carriers in VO 2 .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Solid state switch panel

An intensive study of various forms of transducers was conducted with application towards hermetically sealing the transducer pick off and all electronics. The results indicated that the Hall effect devices and a LED/phototransistor combination were the most practical for this type of application. Therefore, hardware was developed utilizing a magnet/Hall effect transducer for single action switches and LED/phototransistor transducers for rotary multiposition or potentiometer applications. A number of switches were built and models were hermetically sealed to prove the feasibility of this type of fabrication. One of each type of switch was subjected to temperature cycling, vibration, and EMI tests.

Beenfeldt, E.↗

Solid state switch panel

An intensive study of various forms of transducers was conducted with application towards hermetically sealing the transducer and all electronics. The results of the study indicated that the Hall effect devices and a LED/phototransistor combination were the most practical for this type of application. Therefore, hardware was developed utilizing a magnet/Hall effect transducer for single action switches and LED/phototransistor transducers for rotary multiposition or potentiometer applications. All electronics could be housed in a hermetically sealed compartment. A number of switches were built and models were hermetically sealed to prove the feasibility of this type of fabrication. One of each type of switch was subjected to temperature cycling, vibration, and EMI tests. The results of these tests are presented.

Beenfeldt, E.↗

Current transducer

A current transducer for rugged environments uses a solid permalloy core including a magnetic gap for a Hall effect generator and rigid mounting extensions.

McLyman, W. T.↗

Controlling optical-cavity locking using reinforcement learning

Abstract This study applies an effective methodology based on Reinforcement Learning to a control system. Using the Pound–Drever–Hall locking scheme, we match the wavelength of a controlled laser to the length of a Fabry-Pérot cavity such that the cavity length is an exact integer multiple of the laser wavelength. Typically, long-term drift of the cavity length and laser wavelength exceeds the dynamic range of this control if only the laser’s piezoelectric transducer is actuated, so the same error signal also controls the temperature of the laser crystal. In this work, we instead implement this feedback control grounded on Q-Learning. Our system learns in real-time, eschewing reliance on historical data, and exhibits adaptability to system variations post-training. This adaptive quality ensures continuous updates to the learning agent. This innovative approach maintains lock for eight days on average.

47 OTHER INSTRUMENTATION↗

A Review: PFAS Adsorption, Sensing, and Remediation with Engineered Nanoporous Materials

Per- and polyfluoroalkyl substances (PFAS) are among the most abundant environmental contaminant species. They are widespread due to uncontrolled industrial and commercial use and have been linked to health risks such as cancer. With rising global concerns about the public health effects of PFAS, there is an incentive to develop strategies for reliable monitoring and effective PFAS removal, particularly in drinking water. Traditional PFAS sensing techniques are inefficient due to long measurement times, high labor input, high costs, and limitations to ex situ analysis. Current commercially available sorbents for PFAS removal generally lack the ability to capture PFAS components rapidly and quantitatively. Furthermore, existing sorbents are notably inefficient in removing the more toxic, smaller PFAS chemical chains. Large-scale applications of these methods tend to be costly and resource-intensive. Pacific Northwest National Laboratory has developed unique strategies for PFAS sensing and removal with capture probe technology that has an affinity for fluorocarbons, including PFAS. For both sensing and removal, the customizable capture probes can target specific PFAS compounds since they used a metal-organic framework (MOF)-based technology that can be fine-tuned and molecularly tailored. This tailoring of the materials enables high PFAS sensitivity, selectivity, and faster uptake. PNNL’s capture probe materials have been developed into a sensing technique based on the interactions of the capture probes with PFAS at the molecular level and further transduced that to a quantifiable electrochemical response. The materials have been integrated into a sensor platform developed by New Jersey Institute of Technology (NJIT). Tunable capture probes with a range of detection sensitivities allow for faster and more sensitive PFAS detection limits as low as what appears to be 0.5 ng/L (compared to the U.S. Environmental Protection Agency health advisory level of 70 ng/L). Customization of the capture probe results in improved sorption capacities (fast kinetics and high capacities) compared to commercial granular activated carbons. This research applied various experimental and modeling tools to improve understanding the molecular level interactions between the sorbents towards PFAS adsorption properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗