Search NASA⌕ Search

SEARCH · Search NASA

Results for “heat exchanger”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Experimental investigation on heat transfer performance of drain water heat recovery heat exchangers

Water heating accounts for 18 % of residential energy consumption, and a substantial portion of this energy can be recovered through drain water heat recovery systems. Here, this paper investigates the heat transfer performance of drain water heat recovery heat exchangers. Two heat exchanger configurations were studied: vertical (gravity film exchanger) and horizontal. The heat recovery performance of the exchangers was quantified using sensible effectiveness and characteristic curves following the ε-NTU approach. Depending on the flow conditions, heat exchangers with a vertical configuration offered higher heat transfer effectiveness compared with the horizontal configuration under similar operating conditions. Furthermore, the results showed that properly designed and sized heat exchangers can effectively recover considerable amounts of waste heat from drains, depending on flow rates. Additionally, in the vertical heat exchanger configuration, low flow rates result in partially wet conditions, resulting in lower heat transfer effectiveness. Therefore, two distributor configurations are proposed to improve the heat transfer performance of vertically configured heat exchangers at low flow rates. The proposed distributor configurations and data presented in this paper will be useful in the design and development of drain water heat recovery systems in building applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design Considerations for Phase Change Material-Incorporated Heat Exchangers in Water Heating

In recent years, the buildings sector has seen major pushes towards decarbonization through innovations that promote deep electrification. 20% of an average household's energy use comes from water heating, and in the US, over half of all households still use gas water heaters. Of those that use electricity for water heating, the majority use resistive elements rather than heat pump water heaters (HPWHs), the latter of which use 60-70% less energy than the former. However, HPWHs tend to have larger dimensions, preventing current 50-80-gallon tanks on the market from fitting into smaller utility closets sized for 30-40 gallons, such as those found in manufactured housing. Additionally, these smaller HPWHs tend to underperform relative to their larger counterparts. One solution that addresses both space and performance concerns is thermal energy storage, and in particular, phase change materials (PCMs). This study outlines the design process used to produce novel PCM heat exchangers for use in small-volume HPWH tanks, including the identification of design constraints and performance targets relevant to real-world applications. To ensure optimal PCM utilization and tank storage capacity, this works seeks to co-maximize surface area and PCM volume; therefore, this research targets triply periodic minimal surface (TPMS) lattices, which boast enhanced heat transfer capabilities compared to traditional heat exchanger geometries. Starting with a suite of TPMS lattices, we demonstrate a systematic approach for narrowing down feasible designs that comply with identified constraints while meeting PCM performance objectives. Our current results indicate that tuning lattice properties can effectively produce geometries that provide enough energy storage to achieve a 50-gallon capacity out of a 40-gallon HPWH, even when placing the PCM heat exchanger inside the tank. Additionally, we demonstrate successful fabrication of lattices with these tuned properties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Printed circuit primary heat exchanger for power conversion in heat pipe microreactor applications

Here, in the present study, a model was developed for a recuperated air Brayton cycle for heat pipe microreactors, and the effect of the primary heat exchanger type assessed. An annular flow heat exchanger and a printed circuit heat exchanger (PCHE) were evaluated. A sub-sized diffusion bonded, PCHE test specimen was manufactured and tested with nitrogen as the working fluid to validate and improve the PCHE model. A comparison of the thermal cycle efficiency for the Brayton cycle coupled to a heat pipe microreactor using each of the two primary heat exchangers showed competitive performance for both options, with achievable cycle efficiencies of 34 % and 35 % for the annular and printed circuit heat exchangers, respectively. The impact of heat pipe length and additional reheating stages on cycle efficiency was studied. Increasing the heat pipe condenser length from 0.8 to 2.0 m resulted in an increase in cycle efficiency of 3.5 % and 3.2 % for the annular and printed circuit heat exchangers, respectively. The use of additional reheating stages showed a reduction in cycle efficiency since the heat pipe surface area limits the primary heat exchanger size and effectiveness. These results highlight the importance of the primary heat exchanger on the performance of a heat pipe microreactor. Overall, the cycle model, testing, and heat exchanger model showed the potential for the PCHE to improve the economics of a heat pipe microreactor relative to the annular flow heat exchanger, which also opens the possibility to use different heat transfer fluids such as supercritical CO 2 .

PCHE↗

Field Test and Thermal Performance Comparison of a Novel Underground Thermal Battery with a Single U-tube Borehole Heat Exchanger for Geothermal Heat Pump Application

Geothermal Heat Pumps (GHP) are a proven technology to electrify and decarbonize space heating and cooling by utilizing the thermally consistent underground as a heat sink or source. However, the high drilling costs of conventional borehole heat exchangers (BHEs) associated with GHP systems and subsurface heterogeneity have been two major challenges to their widespread adoption. In this paper, we present results from a field-scale pilot of an Underground Thermal Battery (UTB) as a potential alternative to a conventional BHE. To benchmark the UTB performance, a side-by-side field test was conducted to compare the UTB with a conventional BHE installed at the same site. The UTB was installed in a 7.01-meter-deep borehole having a diameter of 0.9 meter, whereas the conventional BHE (with single U-tube loop) is in a borehole with 36.6-meter depth and 0.15-meter diameter. Both are integrated into a GHP system to meet the thermal energy demands of office space at the Illinois Energy Farm on the University of Illinois Urbana-Champaign campus. The system’s performance is compared in terms of heat transfer rate, outlet temperatures, and contributions to the overall thermal power of the GHP system under varying thermal demands and in different heat pump operation modes: heating only, cooling only, and hybrid (alternative, diurnal heating and cooling). Results to date indicate that the UTB delivers a more consistent response under during a time period of varying thermal demands. Its operational performance is better during short-term with higher thermal demands, while the conventional BHE performs better under continuous, long-term thermal demands.

Pokhrel, Sajjan [ORNL] (ORCID:0000000228523749)↗

Development & Experimental Validation of a Generalized Resistance-Capacitance Model for Numerical Simulation of Phase-Change Material Embedded Heat Exchangers

Latent heat thermal energy storage (LHTES) using phase change material (PCM) has attracted increased attention as a viable solution for overcoming the mismatch between energy supply and demand for renewable energy-based systems. PCM-embedded heat exchangers (PCM-HX) have the potential to significantly improve thermal performance due to high storage capacity and low temperature variation during the phase change process. Most models for simulating LHTES heat transfer use Computational Fluid Dynamics (CFD) simulations, which have high computational costs resulting from considering the complex and time-dependent physics relevant to PCM-HXs. In this paper, a Generalized Resistance Capacitance-based Model (GRCM) was developed to predict the thermal performance of arbitrary PCM-HXs in a computationally efficient manner without compromising modeling accuracy. The GRCM is exercised for three case studies: (i) verification for a single-slabbed finned PCM-HX, (ii) verification and validation for a copper foam/paraffin composite PCM-HX, and (iii) validation for a straight tube annular finned PCM-HX. The copper foam PCM-HX uses an electric heater at the top of HX, while the other two configurations utilize water as heat transfer fluid. For the single-slabbed finned PCM-HX melting case, the mean deviation in average PCM temperature predicted by the GRCM compared to the CFD model was between 0.56 – 0.73 K, with maximum temperature deviation of 2.68 K. For the HTF outlet temperature, the validation results showed that GRCM prediction matches very well with experimental data, with mean temperature deviation of 0.24 K during melting case, while for solidification case was 0.34 K. These results showcase the GRCM’s capability for accurately reproducing the thermal characteristics of PCM-HXs with considerably lower computational effort.

42 ENGINEERING↗

Multi-Physics Topology Optimization for Dual Flow Heat Exchangers

Current heat exchanger (HX) designs are subjected to strict constraints pertaining to their manufacturability through conventional lengthy and expensive processes consisting of subtractive, forming and brazing processes. Therefore, existing HXs are typically restricted to the classical and rather simple geometries, such as plate-fin or shell-tube geometries, with lower efficiency and larger size. To increase HX efficiencies, novel designs are needed. Recent advances in topology optimization (TO) and additive manufacturing (AM) offer significant flexibility in design and fabrication of complex geometries, with potentially superior thermo-mechanical performance and high-power density. On the other hand, there is no commercially available software tool that addresses the combined coupling of structural, fluid dynamics, and thermal with multiple materials (hot and cold streams, solid, and void space) in TO of HXs. The goal of this project is to develop a multi-physics multi-phase TO approach to enhance the performance of HXs. The optimized design will be additively manufactured and tested in a physical environment to quantify its performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat exchanger assemblies having embedded sensors

Heat exchanger assemblies are provided that can include: a heat exchanger housing; at least one primary conduit operably coupled to the heat exchanger housing and configured to convey a primary heat exchange fluid; at least one secondary conduit operably coupled to the heat exchanger housing and configured to convey a secondary heat exchange fluid; at least one thermal interface between the primary and secondary fluids; and at least one sensor operably engaged with the thermal interface. Heat exchanger assemblies including molten salt, liquid metal, or water/steam as part of the heat exchange fluids of the heat exchanger assembly are provided. The heat exchanger assemblies can include: at least one thermal interface between primary and secondary heat exchange fluids of the heat exchanger assembly; and a sensor operably engaged with the at least one interface.

Glass, III, Samuel W.↗

Flow maldistribution in plate heat exchangers – Impact, analysis, and solutions

Plate heat exchangers are commonly used in various industrial applications, such as refrigeration, air conditioning, heat pumps, powerplants, and chemical industries. Plate heat exchangers are well known for their superior heat transfer performance, compactness, and low refrigerant charge. Despite offering several advantages, they suffer from flow maldistribution issues. The flow maldistribution can deteriorate both the heat transfer and pressure drop performance, ultimately resulting in a lower system efficiency where plate heat exchangers are deployed. The flow maldistribution issues become more pronounced when the heat exchanger size is relatively large and the number of plates is higher, limiting the deployment of plate heat exchangers in larger industrial systems. Consequently, analyzing and understanding the flow maldistribution behavior in plate heat exchangers and finding ways to mitigate flow maldistribution related issues become essential topics of interest. Further, this review aims to address the effect of flow maldistribution on plate heat exchanger characteristics. First, the experimental and numerical works on flow maldistribution under single-phase and two-phase conditions are detailed. Subsequently, the end-channel and end-plate effects are discussed. Then, the methods to mitigate flow maldistribution in plate heat exchangers are outlined. Finally, based on a thorough literature survey and industrial requirements, future research directions are recommended.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Joining Study for Formed Plate Heat Exchangers (Final Report)

Plate heat exchangers (PHEs) have been used in numerous industrial applications, such as HVAC systems, power generation, transportation and manufacturing. The performance of plate heat exchangers is frequently undermined by corrosion, fouling, and scaling. These phenomena not only diminish heat transfer efficiency but also lead to increased operational costs, maintenance demands, and reduced equipment lifespan. In this project, the team addressed the widespread challenges of corrosion, fouling, and scaling, and explored alternative material solutions. While commonly used materials like stainless steel and titanium offer notable benefits, they can still experience corrosion under certain operating conditions. The advancement of new materials and surface engineering technologies, such as advanced coating, ceramics, composites materials, and high entropy alloys are promising for can help solve these issues, enable longer lifetime and high performance of plate heat exchangers.

36 MATERIALS SCIENCE↗

Fitness for Service Assessment of a Corroded Heat Exchanger

Fermilab s Main Injector Accelerator has used shell & tube heat exchangers to cool various beamline components since its construction in the late 1990s. Many of the heat exchangers still around today are original to the machine. Untreated pond water has been used to exchange heat with the Low Conductivity Water. Throughout the lifetime of Fermilab s heat exchangers, they have undergone significant material degradation in the carbon steel end channels due to corrosion. Wall thickness measurements (per API 510) of each heat exchanger were used to generate a 3D model of the corroded surfaces. In order to continue their safe and reliable operation, ASME FFS-1/API 579 (Fitness-For-Service) was implemented to address their integrity. The assessments consisted of finite element analysis techniques outlined in ASME Section VIII Div. 2 (design by analysis methods for pressure vessels), in accordance with the requirements of ASME FFS-1 Part 4: General Metal Loss, Part 5: Local Metal Loss, and Part 9: Crack Like Flaws. The assessments concluded that each heat exchanger is coined Fit For Service . The Fitness-For-Service standard offers a unique opportunity to facilities and institutions within the DOE National Lab complex to properly and safely assess the integrity of aging equipment necessary to conduct science and research. This poster demonstrates the assessment process and techniques used to determine the heat exchangers are fit for service.

Humenik, Alex [Fermilab]↗

Surface roughness and dimensional evaluation of laser powder bed fusion additively manufactured shell and tube heat exchangers

The growing interest in additively manufactured (AM) heat exchangers drove the need to understand how this construction technique impacts heat exchanger performance. Two primary factors driven by AM that influence heat exchanger performance are surface roughness and geometry. To better understand these parameters, a range of shell and tube heat exchangers constructed using laser powder bed fusion were evaluated. Of those evaluated, the surface roughness throughout a fourteen-tube, zero-baffle heat exchanger was measured using computed tomography. Between the inner and outer tubes, the inner tube surfaces had a greater surface roughness than the outer by 8.07 μm, while the surfaces at the top of the build volume had higher surface roughness values than the bottom. Dimensionally, the inner tube diameters of this heat exchanger were 0.15% different from the design value, while the outer diameters were within a 0.84 % difference. Manual measurements across seven other heat exchangers yielded a maximum 1.15% difference between the design and measured diameters. Across the build volume for all heat exchangers studied, the tube diameters at the top were larger than at the bottom by a maximum of 1.24% difference. Inconsistent melting throughout the individual parts and the build volume, as well as particle splatter and thermal gradient variation were attributed to the surface roughness and dimensional changes seen. These results strengthen the knowledge of dimensional and surface roughness considerations when designing AM heat exchangers.

36 MATERIALS SCIENCE↗

Joining Study for Formed Plate Heat Exchangers (CRADA Final Report)

Plate heat exchangers (PHEs) have been used in numerous industrial applications, such as HVAC systems, power generation, transportation and manufacturing. The performance of plate heat exchangers is frequently undermined by corrosion, fouling, and scaling. These phenomena not only diminish heat transfer efficiency but also lead to increased operational costs, maintenance demands, and reduced equipment lifespan. In this project, the team addressed the widespread challenges of corrosion, fouling, and scaling, and explored alternative material solutions. While commonly used materials like stainless steel and titanium offer notable benefits, they can still experience corrosion under certain operating conditions. The advancement of new materials and surface engineering technologies, such as advanced coating, ceramics, composites materials, and high entropy alloys are promising for can help solve these issues, enable longer lifetime and high performance of plate heat exchangers.

99 GENERAL AND MISCELLANEOUS↗

Sensitivity analysis of design parameters in RowWise borehole layout for ground heat exchangers

Ground source heat pump systems offer a promising pathway toward energy-efficient building heating and cooling. The performance and cost-effectiveness of these systems heavily depend on the design of the ground heat exchanger (GHE), particularly the spatial placement of boreholes used in large commercial buildings. Among various borefield layout strategies, the RowWise approach generates and optimizes borehole configurations within irregular polygonal land boundaries, providing land-use efficiency and installation flexibility. While multiple geometric design parameters constrain the RowWise layout, their influence on the system thermal performance and total drilling requirements remains unclear. Thus, this study presents a sensitivity analysis of key design parameters influencing the RowWise layout of vertical borehole GHEs, including the perimeter spacing ratio, borehole spacing, borehole field rotation angle, and borehole length. GHEDesigner and Ray Tune are employed to generate and assess different RowWise configurations. A series of parametric simulations was conducted to quantify the impact of each parameter on geometric distribution, economic cost, and computational speed. The results provide critical insights into the sensitivity and relative importance of different design parameters of RowWise method, offering practical guidance for designers aiming to optimize GHE layouts by balancing thermal efficiency, land constraints, and economic feasibility.

Xu, Dikai [Purdue University]↗

Visualization of Two-phase Flow Maldistribution in Brazed Plate Heat Exchangers

Brazed plate heat exchangers (BPHEs) are widely used in refrigeration and HVAC applications, but are susceptible to two-phase flow maldistribution especially when operated as evaporators. Existing visualization approaches are either limited to idealized conditions or suffer from poor optical transparency. This paper presents a novel visualization method in which one edge of a BPHE, parallel to the refrigerant inlet or outlet port, is removed by wire electrical discharge machining and replaced with a flat, transparent plate. The planar geometry allows the use of optically and infrared (IR)-transparent materials, enabling both high-speed videography and IR thermography of the two-phase flow at the channel entrances and exits. Preliminary tests with R134a and R1234ze(Z) at saturation temperatures between 5 °C and 15 °C demonstrate that distinct two-phase flow patterns in the inlet header can be clearly identified and differentiated under realistic operating conditions. Potentials of optical flow analysis of high-speed videos are shown to provide objective, quantitative indicators for flow regime characterization and comparison. IR imaging of the outlet port reveals non-uniform temperature distributions at the channel exits, providing independent evidence of maldistribution across the channel stack. Limitations of IR temperature accuracy due to the spectral properties of the sapphire window are discussed, and directions for improvement are identified.

Hausherr, Carsten [Technical University of Berlin ↗

Evaluating Microchannel Heat Exchanger Lifetime for Concentrating Solar Power Applications FY24Q4 (RPPR-1)

Microchannel heat exchanger technology is being pursued for next generation CSP concepts for primary power cycle heat addition and power cycle heat recuperation due to the high heat transfer coefficients and pressure containment advantages of small sCO 2 channels. The economics of future CSP plants as dictated by the SETO 2020 or 2030 targets depend on a heat exchanger with a 30-year lifetime (resisting creep, fatigue, corrosion, erosion) and operational characteristics such as fast ramping and the ability to withstand thermal shock. However, the lifetime and operational limits of microchannel heat exchangers operating at high-temperatures, particularly those constructed from high-nickel alloys, are not well known. This uncertainty has resulted in heat exchanger vendors not being able to accurately forecast heat exchanger lifetime as required by customers, specify operational limits as required by process engineers to prevent premature heat exchanger failure, or overdesign heat exchanger which leads to higher cost than necessary. Our goal is to evaluate heat exchanger lifetime and operational limits for the manufacturing and prototype design for next-generation CSP heat exchanger technology through a combination of collecting experimental data and modeling studies.

14 SOLAR ENERGY↗