Search NASA⌕ Search

SEARCH · Search NASA

Results for “heat flow calorimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation of HAN-TEAN Stabilizers using Microcalorimetry

HAN-TEAN (hydroxylammonium nitrate - triethanolammonium nitrate - in water) is being considered for various propellant applications. This propellant has advantages in terms of insensitivity to impact and fire, low vapor pressure and environmentally benign reaction products. One office concerns with HAN-TEAN is its stability and shelf-life, especially when contaminated with trace metals. Stabilizer systems, consisting of anti-oxidants and/or chealating agents were investigated for their ability to control the decomposition of HAN-TEAN. Isothermal microcalorimetry, an ultrasensitive heat measurement technique, was used to monitor the decomposition of HANTEAN at near ambient temperatures. Isothermal microcalorimetry measures the heat flow from a reaction vessel into a surrounding heat sink. Microcalorimetry is approximately 1,000 times more sensitive than accelerating rate calorimetry (ARC) or differential scanning calorimetry (DSC) for measuring heat flow. Samples of HAN-TEAN containing the stabilizers were spiked with 50 ppm iron and the heat evolution monitored for a period of at least 30 days. Ten stabilizer combinations were tested and the rates of HAN-TEAN decomposition were lowered by 74 to 95 percent in the presence of iron.

Hornung, Steven D.↗

Calorimetry of 25 Ah lithium/thionyl chloride cells

Heat flow measurements of 25-Ah lithium thionyl chloride cells provided a method to calculate an effective thermal potential, E(TP) of 3.907 V. The calculation is useful to determine specific heat generation of this cell chemistry and design. The E(TP) value includes heat generation by electrochemical cell reactions, competitive chemical reactions, and resistance heating at the tabs, connectors, and leads. Heat flow was measured while applying electrical loads to the cell in an isothermal calorimeter set at 0, 20, and 60 C.

Johnson, C. J.↗

Characterization of Thermal Protection Systems: An Analysis of Optical & Thermal Properties

Thermal Protection System Materials & thermal control coatings were characterized by a variety of methodologies including heat flow meter method (HFM), dynamic scanning calorimetry (DSC), fourier transform infrared spectroscopy (FTIR), and Ultra-Violet & Visible light spectroscopy (UV-VIS). Physical properties were measured to aid in the construction of thermal response models for a number a projects including MEDLI and MEDLI2. Comparing pre-flight predictions with actual flight data can allow for a reduction of margins and improve designs. The models enable design of TPS for flight missions and analysis of flight data to understand aerothermal environments experienced on the mission. This presentation reveals critical information: heat capacity (cp vs T), thermal conductivity ( vs T), and emissivity (E vs T) for Super Lightweight Ablative (SLA), Phenolic Impregnated Carbon Ablative (PICA-D), & Heatshield for Extreme Entry Environment Technology (HEEET). These properties were also measured for various thermal control coatings manufactured by AZ Technology. A portion of this work is incomplete and highlights questions to investigate in the future.

Cole, Brian↗

Below Ambient and Cryogenic Thermal Testing

Methods and apparatus for the testing of below-ambient temperature thermal insulation systems have been developed based on boiloff calorimetry. Boiloff calorimetry provides a direct measure of heat flow for below-ambient temperature conditions. The effective thermal conductivity (ke) and heat flux (q) of a test specimen are calculated for a fixed environmental condition (warm boundary temperature; cold boundary temperature; ambient or vacuum pressure). Through its heat of vaporization, liquid nitrogen (LN2) serves as the energy meter. Different apparatus have been built for flat-plate, cylindrical, and pipeline test specimens. Boundary temperatures can range from 353 K down to 77 K (80 C to -196 C). By interposing different insulation layers on the cold boundary, the cryogenic boiloff method is suitable for a wide range of below-ambient temperature applications. A cylindrical apparatus, Cryostat-100, as well as the pipeline test apparatus, Cryostat-P100, are thermally guarded and directly measure absolute thermal performance in watts. Pipe insulation systems can be mechanical, double-walled, or vacuum-jacketed including materials such as foams, cellular glass, aerogel blankets, clam-shell panels, and multilayer insulation. Two test pipelines, 12-meter-long, are mounted between two cold box assemblies. The test pipeline diameter is from 25-mm to 76-mm while the maximum outside diameter including insulation is up to 204-mm. The cold pipe tester design and test methods are discussed, as well as results for select thermal insulation materials. Progress toward a comparative type, bench-top cold pipe tester (Cryostat-P200) is also discussed.

Fesmire, James E.↗

A flow calorimeter for determining combustion efficiency from residual enthalpy of exhaust gases

A flow calorimeter for determining the combustion efficiency of turbojet and ram-jet combustors from measurement of the residual enthalpy of combustion of the exhaust gas is described. Briefly, the calorimeter catalytically oxidizes the combustible constituents of exhaust-gas samples, and the resultant temperature rise is measured. This temperature rise is related to the residual enthalpy of combustion of the sample by previous calibration of the calorimeter. Combustion efficiency can be calculated from a knowledge of the residual enthalpy of the exhaust gas and the combustor input enthalpy. An accuracy of +-0.2 Btu per cubic foot was obtained with prepared fuel-air mixtures, and the combustion efficiencies of single turbojet combustors measured by both the flow-calorimeter and heat-balance methods compared within 3 percentage units. Flow calorimetry appears to be a suitable method for determining combustion efficiencies at high combustor temperatures where ordinary thermocouples cannot be used. The method is fundamentally more accurate than heat-balance methods at high combustion efficiencies and can be used to verify near-100-percent efficiency data.

Evans, Albert↗

Use of calorimetry for end of charge determination

To perform heat flow measurements on batteries, it is necessary to consider the following requirements: establish thermal neutral potential; identify inefficient charging; understand self discharge mechanisms; and provide accurate voltage/temperature data. A discussion is provided in viewgraph format.

Johnson, Chris J.↗

Microcalorimetric Measurements of Hydrogen Peroxide Stability

Recent interest in propellants with nontoxic reaction products has led to a resurgence of interest in hydrogen peroxide for various propellant applications. Because hydrogen peroxide is sensitive to contaminants and materials interactions, stability and shelf life are issues. A relatively new, ultrasensitive heat measurement technique, isothermal microcalorimetry, is being used at the White Sands Test Facility to monitor the decomposition of hydrogen peroxide at near ambient temperatures. Isothermal microcalorimetry measures the beat flow from a reaction vessel into a surrounding heat sink. In these applications, microcalorimetry is approximately 1,000 times more sensitive than accelerating rate calorimetry or differential scanning calorimetry for measuring thermal events. Experimental procedures have been developed for the microcalorimetric measurement of the ultra-small beat effects caused by incompatible interactions of hydrogen peroxide. The decomposition rates of hydrogen peroxide at the picomole/sec/gram level have been measured showing the effects of stabilizers and peroxide concentration. Typical measurements are carried out at 40 C over a 24-hour period, This paper describes a method for the conversion of the heat flow measurements to chemical reaction rates based on thermochemical considerations. The reaction rates are used in a study of the effects of stabilizer levels on the decomposition of propellant grade hydrogen peroxide.

Davis, Dennis D.↗

Differential Scanning Calorimetry (DSC) for planetary surface exploration

Differential Scanning Calorimetry (DSC) is the quantitative measurement of the enthalpic response of a material to a systematic change in temperature. In practice, the heat flow into or outward from a sample is measured as the sample is heated or cooled at a carefully controlled rate. DSC superficially resembles, but is not the same as differential thermal analysis (DTA), which is the measurement of temperature differences between a sample and reference material as the pair is heated or cooled. The fundamental properties measured by DSC are enthalpies and temperatures of phase transitions and constant-pressure heat capacities. Depending on instrument design and the nature of the sample, high-quality DSC analyses can be obtained on only a few milligrams of solid materials. DSC requires direct contact with the sample and generally degrades, if not destroys, the sample as a consequence of heating. In laboratory applications, it is common to subject the gaseous effluent from the DSC to analysis by a separate evolved-gas analyzer (EGA).

Gooding, James L.↗

Apparatus for Testing Flat Specimens of Thermal Insulation

An apparatus has been developed to implement an improved method of testing flat-plate specimens of thermal-insulation materials for cryogenic application. The method includes testing under realistic use conditions that could include vacuum and mechanical loading at a pressure up to 70 psi (=0.48 MPa). The apparatus can accommodate a rigid or flexible specimen having thickness up to 1.25 in. (=3.2 cm) and diameters between 6 and 10 in. (about 15.2 and 25.4 cm, respectively). Typical test conditions include boundary temperatures between 77 K and 373 K and vacuum/interstitial gas filling at a pressure between 10(exp -6) torr (=1.3 x 10(exp -4) Pa) and 760 torr (atmospheric pressure =0.1 MPa). The interstitial gas could be N2, He, CO2, or any other suitable gas to which the insulation is expected to be exposed in use. Relative to prior apparatuses and testing methods, this apparatus and the testing method that it implements offer advantages of relative simplicity and ease of use. The basic principle of operation of the apparatus is that of boil-off calorimetry, using liquid nitrogen or any other suitable liquid that boils at a desired temperature below ambient temperature. Comparative rates of flow of heat through the thicknesses of the specimens (heat-leak rates) and apparent-thermal-conductivity values are obtained from tests of specimens. Absolute values of heat-leak rates and apparent thermal conductivities are computed from a combination of (1) the aforementioned comparative values and (2) calibration factors obtained by testing reference specimens of materials that have known thermal-insulation properties. The apparatus includes a full complement of temperature sensors, a vacuum pump and chamber, a monitoring and control system, and tools and fixtures that enable rapid and reliable installation and removal of specimens. A specimen is installed at the bottom of the vacuum chamber, and a cold-mass assembly that includes a tank is lowered into position above and around the specimen (see figure). A spring-based compensating fixture helps to ensure adequate thermal contact with possibly irregular specimen surfaces. For a high-compression test, the springs can be replaced with spacers. A flat circular load cell at the bottom of the chamber measures the compressive load on the specimen. Once the desired compressive-load, temperature, and vacuum/gas-filling conditions are established, testing begins. During a test, all measurements are recorded by use of a portable data-acquisition system and a computer. The total heat-leak rate is measured and calculated as the boil-off flow rate multiplied by the latent heat of vaporization. The parasitic heat leak (to the side of the specimen and to the top and side of the cold-mass tank) is reduced to a small fraction of the total heat leak by use of a combination of multilayer-insulation (MLI) shield rings, reflective film, a fiberglass/epoxy centering ring, and a bulk fill of aerogel beads. This combination eliminates the need for a cryogenic guard chamber used in a typical prior apparatus to reduce the parasitic heat leak.

Fesmire, James E.↗

Measurement techniques for supersonic combustion testing

Measurement techniques used during nine years of intensive research in supersonic combustion are presented. The tests employed a number of combustor and injector configurations, which were directly connected to a Mach 3.2 supersonic nozzle, and both gaseous hydrogen and storable liquid fuels. Nominal plenum conditions for the arc-heated air were 3000 to 4500 R and 30 atm. Measurements included wall surface pressures, wall temperatures, heat flux, skin friction, instream cone-static and pitot pressures, and gas samples. Measurement and analysis techniques have been developed for determining total enthalpy of an airstream containing NO concentrations in excess of equilibrium using the two-throat technique, bulk combustion efficiency using steam calorimetry, radial gradients of fluid properties in the combustor exit plane using a stream tube method, and wall shear from measurements of heat transfer in a reacting supersonic flow using Reynolds analogy.

Orth, R. C.↗

Towards Measurement of the Time-resolved Heat Release of Protein Conformation Dynamics

We present a way to observe time-resolved heat release using a laminar flow diffusional mixer coupled with a highly sensitive infrared camera which measures the temperature change of the solvent. There are significant benefits to the use of laminar flow mixers for time-resolved calorimetry: (1) The thermal signal can be made position and time- stationary to allow for signal integration; (2) Extremely small volumes (nl/s) of sample are required for a measurement; (3) The same mixing environment can be observed spectroscopically to obtain state occupation information; (4) The mixer allows one to do out of equilibrium dynamic studies. The hope is that these measurements will allow us probe the non-equilibrium thermodynamics as a protein moves along a free energy trajectory from one state to another.

Puchalla, Jason↗

Challenges with Heat Flux Calorimeters used in Arc Jets

Occasionally large errors have occurred in some of the calorimeters used in the arc jet facilities. Some slug calorimeters would measure twice the expected heat flux and some Coaxial TC calorimeters would measure half the expected heat flux. While these errors in heat flux measurements are easy to identify and discard / dismiss, the concern is that less spectacular errors are difficult to detect. This inspired a critical look at the calorimetry used to measure stagnation heat flux in the NASA Ames Arc Jet facilities. Numerous sources of error were investigated, and the culprit in the case of slug calorimeters was determined to be leaks in the stagnation calorimeter assembly resulting in flow along the side of the slug. In the case of the coaxial TC calorimeter, it is hypothesized that in some calorimeters there is a partial electrical short circuit in the Coaxial TC sensor element somewhere in the middle of the calorimeter.

Calorimeter↗

Small scale demand type neon liquefaction plant

Low-temperature measurement of the thermal conductivity of insulating materials is generally made using a boil-off calorimetry technique involving liquid hydrogen (LH2). Liquid neon (LNe) has nearly the same normal boiling point as LH2, but has a much larger heat of vaporization, allowing extended run times. The main drawback of using LNe has been its excessive cost; $170.00 versus $1.50/l for LH2 (1989 prices). A neon liquefaction plant has been designed and constructed to capture, purify, and refrigerate the neon boil-off from calorimetry experiments. Recycling the neon reduces operating costs to approximately $20/l. The system consists of a purification section, a heat exchanger, LNe and LH2 storage dewars, and a fully automated control system. After purification, neon is liquified in the heat exchanger by LH2 flowing countercurrently through stainless steel cooling coils. Hydrogen flow is automatically adjusted to keep the neon at its normal saturation temperature, 27 K. The liquid neon is then stored in a dewar placed directly below the heat exchanger.

Dube, W. P.↗

Characterization of a 50kW Inductively Coupled Plasma Torch for Testing of Ablative Thermal Protection Materials

With the development of new manned spaceflight capabilities including NASA's Orion capsule and the Space-X Dragon capsule, there is a renewed importance of understanding the dynamics of ablative thermal protection systems. To this end, a new inductively coupled plasma torch facility is being developed at UT-Austin. The torch operates on argon and/or air at plasma powers up to 50 kW. In the present configuration the flow issues from a low-speed subsonic nozzle and the hot plume is characterized using slug calorimetry and emission spectroscopy. Preliminary measurements using emission spectroscopy have indicated that the torch is capable of producing an air plasma with a temperature between 6,000 K and 8,000 K depending on the power and flow settings and an argon plasma with a temperature of approximately 12,000 K. The operation envelope was measured, and heat flux measured for every point within the envelope using both a slug calorimeter and a Gardon gauge heat flux sensor. The torch was found to induce a stagnation point heat flux of between 90 and 225 W/sq cm.

Greene, Benton R.↗