A Multifaceted Analysis of Chemical-Absorption Heat Pump Technology for Integrated Energy Systems

Integrated Energy Systems (IES) research and development is essential for improving the economic usage of lowcarbon energy sources such as nuclear power, solar, and wind in the U.S. An ideal IES uses various energy sources and delivers energy to the power grid and industry as efficiently as possible. As part of this effort, there are many opportunities to use low-carbon energy for industries requiring process heat for production of many chemicals and fuels [1]. Currently, industries only have the option to burn CO2 emitting fuels or use resistance heaters for this process heat. Using resistance heaters is one way to electrify a process, allowing for low-carbon energy sources to be used, but is an inefficient method unless temperatures exceed 1000?C. Heat pumps have long been used to provide efficient heating or cooling by moving heat instead of generating it. More traditional heat pumps such as vapor compression heat pumps and absorption heat pumps are limited to temperatures below 300?C due to refrigerant and component material limits. However, chemical heat pumps have been investigated as an option for pumping heat at temperatures above 600?C [2], making the heat more applicable to many more chemical and fuel production processes.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improving Reliability, Weight and Cost of Gas-Fired Absorption Heat Pumps

The objective of the project was to identify and verify a viable path for the use of aluminum tubes in evaporators for gas-fired ammonia-water absorption heat pumps (GAHP), via identification of a suitable alloy, coating, inhibitor, process, or combination, for the purpose of achieving weight and cost reduction.

03 NATURAL GAS↗

Sorption heat pump and control method

A method operates an absorption heat pump system, specifically the flow of hydronic cooling fluid through the condenser during system start-ups, or when the cooling fluid temperature is low. To minimize the time for an absorption heat pump to reach full cooling or heating capacity, it is desirable for the high side pressure to increase as fast as possible, and the low side pressure to decrease as fast as possible. Since the high side pressure is a function of the temperature of the refrigerant exiting the condenser, if the condenser cooling fluid temperature is low, the corresponding high side pressure will be low, which may not permit adequate working fluid flow rates from the high pressure side of the system to the low pressure side.

Garrabrant, Michael A.↗

Effects of Internal and External Heat Sources on Cladding Microstructure and Rupture Performance

In the event of a Loss of Coolant Accident (LOCA), the primary supply of cooling water for a nuclear reactor is lost, leading to a significant pressure differential across the cladding wall. Without adequate cooling, the fuel rods continue to heat as a result of fission reactions. Research at Oak Ridge National Laboratory’s (ORNL’s) Severe Accident Test Station (SATS) is currently focused on evaluating fuel cladding performance using an external infrared lamp as a heat source, whereas legacy testing primarily utilized an internal heating approach. While external heating may better simulate the effect of neighboring fuel rods heating a central rod, it may not accurately represent the internal heat absorption from the fuel during accident transients. The heating dynamics depend greatly on the fuel rod's position within the bundle and the reactor. To fully understand the implications of a LOCA event and assess the influence of internal heating on cladding performance, combined internal heating and pressurization capability was developed at ORNL. Tests were conducted to compare cladding segments heated internally (representing heat from the fuel within the rod) and externally (representing heat from adjacent fuel rods). The findings indicate that both internal and external heating result in comparable rupture temperatures during 5°C/s laboratory LOCA tests and also agree with legacy test data. Axial temperature gradients and internal heat source dispersal were found to significantly impact cladding deformation and rupture geometry. Clear modifications were outlined to further improve the capability with heating rates above 5°C/s.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of Internal and External Heat Sources on Cladding Microstructure and Rupture Performance

In the event of a Loss of Coolant Accident (LOCA), the primary supply of cooling water for a nuclear reactor is lost, leading to a significant pressure differential across the cladding wall. Without adequate cooling, the fuel rods continue to heat as a result of fission reactions. Research at Oak Ridge National Laboratory’s (ORNL’s) Severe Accident Test Station (SATS) is currently focused on evaluating fuel cladding performance using an external infrared lamp as a heat source, whereas legacy testing primarily utilized an internal heating approach. While external heating may better simulate the effect of neighboring fuel rods heating a central rod, it may not accurately represent the internal heat absorption from the fuel during accident transients. The heating dynamics depend greatly on the fuel rod's position within the bundle and the reactor. To fully understand the implications of a LOCA event and assess the influence of internal heating on cladding performance, combined internal heating and pressurization capability was developed at ORNL. Tests were conducted to compare cladding segments heated internally (representing heat from the fuel within the rod) and externally (representing heat from adjacent fuel rods). The findings indicate that both internal and external heating result in comparable rupture temperatures during 5°C/s laboratory LOCA tests and also agree with legacy test data. Axial temperature gradients and internal heat source dispersal were found to significantly impact cladding deformation and rupture geometry. Clear modifications were outlined to further improve the capability with heating rates above 5°C/s.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The encasulation effect on thermal performance of micro-encapsulated phase change materials during energy absorption

Understanding the performance of the thermal storage materials is required to successfully meet the needs of next generation concentrating solar power projects. This study focuses on the thermal characteristics of the micro-encapsulated phase change material (MEPCM) with metallic core under high temperature. A numerical model was developed and verified to study the transient heat absorption process of MEPCMs made of tin, aluminum and copper core. Convective heat transfer rate, total energy absorption and volumetric energy density were presented. The effect of encapsulation on theses variables was analyzed under various boundary and initial conditions. Its impact on characteristic time variables was discussed. The method presented can be adopted to analyzing both manufacturing and application processes for MEPCMs of various compositions, during which melting and solidification happen. Given certain operating conditions, the results from the model can be referenced to obtain optimal thermal performance of these materials.

Benner, Jingru↗

Heat Exchanger Design Optimization for Mitigation of Diesel Engine Exhaust Fouling

Abstract The design optimization of a diesel exhaust-coupled heat and mass exchanger that drives a 2.71 kW cooling capacity absorption heat pump is presented in this study. Fouling layer thermal resistance and pressure drops from single-tube experiments are used to develop a thermodynamic, heat transfer, and pressure drop model for the exhaust-coupled desorber. A parametric study is performed to select a desorber design that meets system performance while minimizing footprint. Experimental heat duties and pressure drops are within 10% and 3%, respectively, of the model predictions. Thus, large data sets from single-tube experiments with representative geometries are successful in accounting for fouling effects at the component level. Desorber design optimization based on this approach ensures continued heat pump performance after fouling. This study, along with the single-tube experiments, presents a systematic approach to design exhaust-coupled heat exchangers while considering the effects of fouling. These results are applicable for a wide range of waste-heat recovery applications, and this method can be extended to different geometries and operating conditions.

Energy & Fuels↗

Internally cooled membrane-based absorber for dehumidification and water heating: Validated model and simulation study

This report presents a comprehensive model for advanced membrane-based absorber components accounting for three separate fluid streams, one of them providing internal cooling, with complex flow patterns. The model was implemented with various liquid desiccants and their properties (including LiCl, CaCl 2 , and [emim][OMS] ionic liquid [IL]). The model has been validated using data from two laboratory prototype absorbers, one with CaCl 2 as the working fluid and one with an IL as the working fluid. Entropy analysis was further carried out to verify the model and understand effect of internal cooling on the entropy variation of three fluid streams. The developed model and codes are expected to enable detailed configuration optimization and provide in-depth understanding of three-fluid heat and mass exchanger (HMX) performance. The paper also describes parametric studies of the HMX components in utilizing the latent heat removed in space cooling to heat water and numerically explores the unique benefit of its application in a semi-open absorption heat pump water heater. The results show that a single three-fluid HMX has the potential to achieve simultaneous dehumidification and water heating efficiently at cost effectiveness, particularly in hot and humid climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy demand reduction in the built environment using shallow geothermal integrated energy systems: Part II – Hybrid ground source heat pump for building heating

The research collection aims at finding the various possible opportunities for the effective integration of shallow geothermal energy (SGE) to decrease the energy demand in the built environment and to reduce emission associated with it. The direct utilization of SGE using a ground source heat pump (GSHP) has been reviewed in comprehensive review part I and part II. From the extensive review, we have found that the hybrid GSHP is needed to avoid ground thermal imbalance and peak demand. Hybrid GSHP can adopt various supplemental heat sources and sinks according to the local climatic conditions and the balance of energy demands. The primary focus on the integration of subsystems such as biomass, solar energy (PV, PVT, and collector), phase change material, micro gas turbine, and absorption heat pump with GSHP is presented for heating application. This comprehensive review part III highlights the recent research findings and a potential gap in hybrid GSHP for further research and developments

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic energy system modeling using hybrid physics-based and machine learning encoder–decoder models

Three model configurations are presented for multi-step time series predictions of the heat absorbed by the water and steam in a thermal power plant. The models predict over horizons of 2, 4, and 6 steps into the future, where each step is a 5-minute increment. The evaluated models are a pure machine learning model, a novel hybrid machine learning and physics-based model, and the hybrid model with an incomplete dataset. The hybrid model deconstructs the machine learning into individual boiler heat absorption units: economizer, water wall, superheater, and reheater. Each configuration uses a gated recurrent unit (GRU) or a GRU-based encoder–decoder as the deep learning architecture. Mean squared error is used to evaluate the models compared to target values. The encoder–decoder architecture is over 11% more accurate than the GRU only models. The hybrid model with the incomplete dataset highlights the importance of the manipulated variables to the system. The hybrid model, compared to the pure machine learning model, is over 10% more accurate on average over 20 iterations of each model. Automatic differentiation is applied to the hybrid model to perform a local sensitivity analysis to identify the most impactful of the 72 manipulated variables on the heat absorbed in the boiler. The models and sensitivity analyses are used in a discussion about optimizing the thermal power plant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermodynamic modeling of MDEA(aq)-NH 3 (aq)-K 2 CO 3 (aq)-CO 2 (aq) using the Extended UNIQUAC model

Here, the development of advanced processes for carbon dioxide capture requires reliable thermodynamic models to ensure accurate process design. This work presents an optimized parameter set of the Extended UNIQUAC model for advanced mixed solvent solutions containing CO 2 -MDEA-NH 3 -K 2 CO 3 in water. The model was parameterized using vapor–liquid equilibrium, pure component saturation pressure, excess enthalpy, heat of absorption, molar heat capacity, apparent molar heat capacity, and solid–liquid equilibrium. These thermal and equilibrium properties cover temperatures between 253.6 K to 600 K and pressures up to 75.6 bar. The current model represents an extension of previous versions that were suitable for modeling aqueous NH 3 and K 2 CO 3 solutions. This parametrization accounts for molecular interactions between MDEA and these two components, which allows for the design of advanced capture processes. This paper demonstrates that the new model parameters are valid within the range of operational conditions typically found in CO 2 capture processes.

42 ENGINEERING↗

Novel geometries for air-cooled condensation of ammonia-water mixtures

An analytical and experimental investigation of air-cooled condensers for small-scale ammonia-water absorption heat pumps is presented. Conventional round-tube corrugated fin design and a novel multi-pass tube array design are considered for a condenser operating at severe ambient conditions within a compact footprint. Segmental heat and mass transfer models are developed to gain a deeper understanding of the characteristics of each design. Predicted heat duties are within 5% of the measured values. The limitations of correlations to predict air-side pressure drop in corrugated fins are identified. The performance of the novel multi-pass tube array condenser was comparable to that of conventional condensers, but is determined to be air-side limited throughout length of the heat exchanger. An improved multi-pass condenser design with fins for increased air-side area is proposed using the insights gained from the modeling and experiments. In closing this design meets the heat duty requirements at severe ambient conditions, while decreasing the size of the heat exchanger by 33%.

42 ENGINEERING↗

Thermodynamics-guided machine learning model for predicting convective boundary layer height and its multi-site applicability

Accurate estimation of convective boundary layer height (CBLH) is vital for weather, climate, and air quality modeling. Machine learning (ML) shows promise in CBLH prediction, but input parameter selection often lacks physical grounding, limiting generalizability. This study introduces a novel ML framework for CBLH prediction, integrating thermodynamic constraints and the diurnal CBLH cycle as an implicit physical guide. Boundary layer growth is modeled as driven by surface heat fluxes and atmospheric heat absorption represented with the low tropospheric stability, using the diurnal cycle as input and output. TPOT and AutoKeras are employed to select optimal models, validated against Doppler lidar-derived CBLH data, achieving an R 2 of 0.84 across untrained years. Comparisons of eddy covariance (ECOR) and energy balance Bowen ratio (EBBR) flux measurements show the same prediction capability. Models trained on the ARM SGP C1 site with ECOR data and tested at E37 and E39 yield R 2 values of 0.79 and 0.81, respectively, demonstrating their adaptability. The ML model trained with all sites' data slightly enhances the performance compared with ML models trained over single-site data. The interquartile range for predicted CBLH is consistently narrower than that for DL-derived CBLH, reflecting lower variability in predicted CBLH compared to DL-derived CBLH, which is influenced by additional factors, which are not well represented with the model inputs. The model's generalizability across multiple sites at the ARM SGP site demonstrates its potential for transfer to greater distances, offering a scalable approach for enhancing boundary layer parameterization in atmospheric models.

Chu, Yufei [Stony Brook Univ., NY (United States)]↗

Solar receivers and methods for capturing solar energy

Thermal receivers, systems, and methods are disclosed that efficiently capture concentrated solar energy into a plurality of heat absorption bodies for conversion into thermal energy. In an embodiment, the thermal receivers, systems, and methods enable simultaneous electricity conversion and thermal energy capture. The receiver design enables a high penetration of concentrated sunlight deep into the thermal receiver to increase light trapping and reduce thermal losses. The thermal receiver is integrated with a photovoltaic (PV) receiver platform that converts some of the incident light to electricity while passing the remaining light to the thermal receiver. In another embodiment, other thermal receivers, systems, and methods are disclosed that efficiently capture concentrated solar energy into a sheet of falling particles. In an embodiment, the thermal receivers, systems, and methods enable simultaneous electricity conversion and thermal energy capture.

Ho, Clifford K.↗

Membrane-based Ionic Liquid Absorption System for Ultra-Efficient Dehumidification and Heating

The project team – comprising the University of Florida (UF), GTI Energy, and Modine Manufacturing – sought to develop a highly efficient heat-powered absorption cycle with combined dehumidification and heat pumping. This DOE-supported project advanced the technology from a TRL of 3 to 6, culminating in the development of a 1,000 CFM system. Key innovations implemented in the system addressed the low efficiency, size, cost, and reliability challenges of conventional absorption cycles. Specifically, the system was enabled by: (1) a semi-open cycle that allowed simultaneous dehumidification and heat recovery, (2) non-crystallizing ionic liquids (ILs) that enabled “double-effect” operation at elevated temperatures without the need for costly control equipment, (3) a compact membrane-based absorber that confined the IL and directly cooled it to achieve low dew points, and (4) a novel, highly integrated desorber–condenser assembly that reduced size, weight, and cost. The technology was developed with commercial HVAC applications in mind, particularly for separate sensible and latent cooling (SSLC), an innovation aimed at achieving independent and more efficient humidity control.

42 ENGINEERING↗