Search NASA⌕ Search

SEARCH · Search NASA

Results for “heat pump systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Assessment of solar-assisted gas-fired heat pump systems

As a possible application for the Goldstone Energy Project, the performance of a 10 ton heat pump unit using a hybrid solar gas energy source was evaluated in an effort to optimize the solar collector size. The heat pump system is designed to provide all the cooling and/or heating requirements of a selected office building. The system performance is to be augmented in the heating mode by utilizing the waste heat from the power cycle. A simplified system analysis is described to assess and compute interrrelationships of the engine, heat pump, and solar and building performance parameters, and to optimize the solar concentrator/building area ratio for a minimum total system cost. In addition, four alternative heating cooling systems, commonly used for building comfort, are described; their costs are compared, and are found to be less competitive with the gas solar heat pump system at the projected solar equipment costs.

Lansing, F. L.↗

Performance Evaluation of a Vapor-compression-cycle Based Heat Pump System for a Lunar Habitat under the Impact of Dust Deposits on the Coupled Radiators

Space exploration gains new momentum. A near goal is set by NASA to return humans to the Moon andestablish a sustainable presence on the lunar surface for more repeatable and affordable expeditions.The lunar dust is one of the dangerous environment hazard causing serious problems for explorationactivities. In this paper, in order to study the impact of lunar dust on the performance of a thermalmanagement system for a lunar habitat, a dynamical model of an active thermal control system that iscomprised of a vapor-compression cycle heat pump and a radiator loop is developed. A heat pump to liftthe heat rejection temperature is required due to high lunar daytime surface temperature. Parametricstudies on radiator size, percentage of dust coverage on the radiator, and lunar habitat location arecarried out. The results show that lunar deposits can significantly increase the power consumption ofthe thermal management system. A dust covered radiator panel results in net heat input to the heattransfer fluid during the period of strong solar irradiance, causing deteriorated performance of theradiator loop. The lunar dust contamination problem raises the requirement of redundancy design of asystem for fault tolerance. A synergetic design of a thermal management system, a power generationsystem and robotic maintenance system is proposed to achieve maximal mass cut for a whole lunarhabitat system.

Chunjian Pan↗

Novel concept for detection of a fluid flow fault in a pumped fluid heat rejection system

A pumped fluid heat rejection system (HRS) requires continuous flow of the working fluid to ensure that the components controlled by the HRS stay within their allowable temperature limits. An interruption of flow could result in violations of hardware qualification limits and mission failure. Some of these violations can happen within a few hours. Hence, quick detection of a flow fault to invoke mitigation measures is very critical. In typical pumped fluid HRS, dual or triple pumps are employed to switch the backup units in case the primary unit were to fail. The key metric for the selection of a fault detection system is that it should detect the fault much before the fault’s impact on the thermal health of the HRS controlled components is realized. A trade study was conducted to select such a system for the Europa Clipper Mission to Europa, a moon of Jupiter that is planned for a launch in 2023. Out of the several concepts studied, the most attractive one was a novel and simple concept that uses a low power film heater attached to a section of the HRS tubing. While the fluid flows at its nominal rate, the high thermal coupling of the flowing fluid leads to the tube being close to the fluid’s temperature. However, when the flow stops, the heater warms the small thermal mass of the tubing to a high temperature in a short span of time (~15 minutes). This large temperature rise would then imply that the flow must have stopped. This paper will describe the various concepts considered, the chosen concept, its implementation, and the results of developments tests to validate its performance.

Schmidt, Tyler↗

Waste-Heat-Driven Cooling Using Complex Compound Sorbents

Improved complex-compound sorption pumps are undergoing development for use as prime movers in heat-pump systems for cooling and dehumidification of habitats for humans on the Moon and for residential and commercial cooling on Earth. Among the advantages of sorption heat-pump systems are that they contain no moving parts except for check valves and they can be driven by heat from diverse sources: examples include waste heat from generation of electric power, solar heat, or heat from combustion of natural gas. The use of complex compound sorbents in cooling cycles is not new in itself: Marketing of residential refrigerators using SrCl2 was attempted in the 1920s and 30s and was abandoned because heat- and mass-transfer rates of the sorbents were too low. Addressing the issue that gave rise to the prior abandonment of complex compound sorption heat pumps, the primary accomplishment of the present development program thus far has been the characterization of many candidate sorption media, leading to large increases in achievable heat- and mass-transfer rates. In particular, two complex compounds (called "CC260-1260" and "CC260-2000") were found to be capable of functioning over the temperature range of interest for the lunar-habitat application and to offer heat- and mass-transfer rates and a temperature-lift capability adequate for that application. Regarding the temperature range: A heat pump based on either of these compounds is capable of providing a 95-K lift from a habitable temperature to a heat-rejection (radiator) temperature when driven by waste heat at an input temperature .500 K. Regarding the heat- and mass-transfer rates or, more precisely, the power densities made possible by these rates: Power densities observed in tests were 0.3 kilowatt of cooling per kilogram of sorbent and 2 kilowatts of heating per kilogram of sorbent. A prototype 1-kilowatt heat pump based on CC260-2000 has been built and demonstrated to function successfully.

Rocketfeller, Uwe↗

Convergent strand array liquid pumping system

A surface-tension liquid pumping system is provided by one or more arrays of converging solid monofilament fibers or metal wires (strands) spaced apart at an input end to gather liquid, and gathered close together at the opposite end where menisci forms between wetted strands to force liquid in the direction of convergence of the strands. The liquid pumping system is independent of gravity. It is illustrated as being used in a heat pump having a heating box to vaporize the liquid and a condensing chamber. Condensed liquid is returned by the pumping system to the heating box where it is again vaporized. A vapor tube carries the vapor to the condensing chamber. In that way, a closed system pumps heat from the heating box to the evaporating chamber and from there radiated to the atmosphere.

Collins, Earl R., Jr.↗

Conceptual design of a lunar base thermal control system

Space station and alternate thermal control technologies were evaluated for lunar base applications. The space station technologies consisted of single-phase, pumped water loops for sensible and latent heat removal from the cabin internal environment and two-phase ammonia loops for the transportation and rejection of these heat loads to the external environment. Alternate technologies were identified for those areas where space station technologies proved to be incompatible with the lunar environment. Areas were also identified where lunar resources could enhance the thermal control system. The internal acquisition subsystem essentially remained the same, while modifications were needed for the transport and rejection subsystems because of the extreme temperature variations on the lunar surface. The alternate technologies examined to accommodate the high daytime temperatures incorporated lunar surface insulating blankets, heat pump system, shading, and lunar soil. Other heat management techniques, such as louvers, were examined to prevent the radiators from freezing. The impact of the geographic location of the lunar base and the orientation of the radiators was also examined. A baseline design was generated that included weight, power, and volume estimates.

Simonsen, Lisa C.↗

Thermal Technology Development Activities at the Goddard Space Flight Center: 2001

Activities include the development of two phase systems which are composed of 1) heat pipes and variable conductance heat pipes, 2)capillary pumped loops, 3) loop heat pipes, 4) vapor compression systems (heat pumps), 5) phase change materials. Also in the development phase are variable emittance surfaces, advanced coatings, high conductivity materials, and electrohydrodynamic (EHD) thermal control systems.

Butler, Dan↗

Jet pump-drive system for heat removal

A jet pump, in combination with a TEMP, is employed to assure safe cooling of a nuclear reactor after shutdown. A TEMP, responsive to the heat from the coolant in the secondary flow path, automatically pumps the withdrawn coolant to a higher pressure and thus higher velocity compared to the main flow. The high velocity coolant is applied as a driver flow for the jet pump which has a main flow chamber located in the main flow circulation pump. Upon nuclear shutdown and loss of power for the main reactor pumping system, the TEMP/jet pump combination continues to boost the coolant flow in the direction it is already circulating. During the decay time for the nuclear reactor, the jet pump keeps running until the coolant temperature drops to a lower and safe temperature. At this lower temperature, the TEMP/jet jump combination ceases its circulation boosting operation. The TEMP/jet pump combination is automatic, self-regulating and provides an emergency pumping system free of moving parts.

French, J. R.↗

Subcontracted activities related to TES for building heating and cooling

The subcontract program elements related to thermal energy storage for building heating and cooling systems are outlined. The following factors are included: subcontracts in the utility load management application area; life and stability testing of packaged low cost energy storage materials; and development of thermal energy storage systems for residential space cooling. Resistance storage heater component development, demonstration of storage heater systems for residential applications, and simulation and evaluation of latent heat thermal energy storage (heat pump systems) are also discussed. Application of thermal energy storage for solar application and twin cities district heating are covered including an application analysis and technology assessment of thermal energy storage.

Martin, J.↗

Solar heating and hot water system installed at Southeast of Saline, Unified School District 306, Mentor, Kansas

The solar system, installed in a new building, was designed to provide 52 percent of the estimated annual space heating load and 84 percent of the estimated annual potable hot water requirement. The liquid flat plate collectors are ground-mounted and cover a total area of 5125 square feet. The system will provide supplemental heat for the school's closed-loop water-to-air heat pump system and domestic hot water. The storage medium is water inside steel tanks with a capacity of 11,828 gallons for space heating and 1,600 gallons for domestic hot water. The solar heating facility is described and drawings are presented of the completed system which was declared operational in September 1978, and has functioned successfully since.

Source record↗

Development of a nonazeotropic heat pump for crew hygiene water heating

A heat pump system is currently under development to produce hot water for crew hygiene on future manned space missions. The heat pump uses waste heat sources and a nonazeotropic working fluid in a highly efficient cycle. The potential benefits include a reduction in peak power draw from 2 to 5 kW for electric cartridge heaters to just more than 100 W for the heat pump. As part of the heat pump development project, a unique high efficiency compressor was developed to maintain lubrication in a zero-gravity environment.

Walker, David H.↗

Free-piston Stirling Engine system considerations for various space power applications

Free-Piston Stirling Engines (FPSE) have the potential to provide high reliability, long life, and efficient operation. Therefore, they are excellent candidates for the dynamic power conversion module of a space-based, power-generating system. FPSE can be coupled with many potential heat sources (radioisotope, solar, or nuclear reactor), various heat input systems (pumped loop, heat pipe), heat rejection (pumped loop or heat pipe), and various power management and distribution systems (ac, dc, high or low voltage, and fixed or variable load). This paper reviews potential space missions that can be met using free-piston Stirling engines and discusses options of various system integration approaches. This paper briefly outlines the program and recent progress.

Dochat, George R.↗

Solar technology in the Federal Republic of Germany

A series of papers dealing with the status of solar research and development in the Federal Republic of Germany are presented at a conference in Greece with the object of promoting international cooperation in solar energy utilization. The reports focus on solar collector designs, solar systems, heat pumps, solar homes, solar cooling and refrigeration, desalination and electric power generation. Numerous examples of systems produced by German manufacturers are illustrated and described, and performance data are presented.

Source record↗

Aerospace applications of magnetic bearings

Magnetic bearings have traditionally been considered for use in aerospace applications only where performance advantages have been the primary, if not only, consideration. Conventional wisdom has been that magnetic bearings have certain performance advantages which must be traded off against increased weight, volume, electric power consumption, and system complexity. These perceptions have hampered the use of magnetic bearings in many aerospace applications because weight, volume, and power are almost always primary considerations. This paper will review progress on several active aerospace magnetic bearings programs at SatCon Technology Corporation. The magnetic bearing programs at SatCon cover a broad spectrum of applications including: a magnetically-suspended spacecraft integrated power and attitude control system (IPACS), a magnetically-suspended momentum wheel, magnetic bearings for the gas generator rotor of a turboshaft engine, a vibration-attenuating magnetic bearing system for an airborne telescope, and magnetic bearings for the compressor of a space-rated heat pump system. The emphasis of these programs is to develop magnetic bearing technologies to the point where magnetic bearings can be truly useful, reliable, and well tested components for the aerospace community.

Downer, James↗

Absorption heat pump for space applications

In the first part, the performance of the Absorption Heat Pump (AHP) with water-sulfuric acid and water-magnesium chloride as two new refrigerant-absorbent fluid pairs was investigated. A model was proposed for the analysis of the new working pairs in a heat pump system, subject to different temperature lifts. Computer codes were developed to calculate the Coefficient of Performance (COP) of the system with the thermodynamic properties of the working fluids obtained from the literature. The study shows the potential of water-sulfuric acid as a satisfactory replacement for water-lithium bromide in the targeted temperature range. The performance of the AHP using water-magnesium chloride as refrigerant-absorbent pair does not compare well with those obtained using water-lithium bromide. The second part concentrated on the design and testing of a simple ElectroHydrodynamic (EHD) Pump. A theoretical design model based on continuum electromechanics was analyzed to predict the performance characteristics of the EHD pump to circulate the fluid in the absorption heat pump. A numerical method of solving the governing equations was established to predict the velocity profile, pressure - flow rate relationship and efficiency of the pump. The predicted operational characteristics of the EHD pump is comparable to that of turbomachinery hardware; however, the overall efficiency of the electromagnetic pump is much lower. An experimental investigation to verify the numerical results was conducted. The pressure - flow rate performance characteristics and overall efficiency of the pump obtained experimentally agree well with the theoretical model.

Nguyen, Tuan↗

Experiment to determine properties of packed particle beds and regenerators at cryogenic temperatures

Studies related to the development of magnetic refrigeration and heat pump systems in temperature ranges from 4 K to ambient temperature and above have been conducted, taking into account the testing of the properties of packed-particle beds and regenerators at cryogenic temperatures as low as 4 K as an essential part of these studies. The present paper provides a description of the developed experimental apparatus and presents the results of recent measurements on packed-particle beds in the liquid helium and liquid nitrogen temperature ranges. Attention is given to a schematic of the apparatus and the data acquisition system, the various modes of gas flow, a schematic of a typical test bed with thermocouple positions, the calculation of transient heat transfer rates at different positions in the bed, the governing equations, and the procedures used for solving these equations.

Barclay, J. A.↗

Process for producing an activated carbon adsorbent with integral heat transfer apparatus

A process for producing an integral adsorbent-heat exchanger apparatus useful in ammonia refrigerant heat pump systems. In one embodiment, the process wets an activated carbon particles-solvent mixture with a binder-solvent mixture, presses the binder wetted activated carbon mixture on a metal tube surface and thereafter pyrolyzes the mixture to form a bonded activated carbon matrix adjoined to the tube surface. The integral apparatus can be easily and inexpensively produced by the process in large quantities.

Jones, Jack A.↗