Search NASA⌕ Search

SEARCH · Search NASA

Results for “heating fuel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Potential Heating Energy and Cost Savings of Dual Fuel Heat Pump Controls as a Residential Building Equipment Retrofit in the U.S.

This study investigated the energy and cost savings potential by modeling a dual fuel heat pump system with its control for a residential building in (5A) cold climate in U.S. The simulation analysis showed that the application of the DFHP system and its control to the target building can save the heating energy by 42% over a gas furnace system (baseline system). Although the HP-only system can save more heating energy (i.e., 53%) over the baseline system than DFHP system does, the DFHP with its control demonstrated the higher cost savings when a time of use electricity rate was considered.

Yoon, Yeobeom↗

Experiments on fuel heating for commercial aircraft

An experimental jet fuel with a -33 C freezing point was chilled in a wing tank simulator with superimposed fuel heating to improve low temperature flowability. Heating consisted of circulating a portion of the fuel to an external heat exchanger and returning the heated fuel to the tank. Flowability was determined by the mass percent of unpumpable fuel (holdup) left in the simulator upon withdrawal of fuel at the conclusion of testing. The study demonstrated that fuel heating is feasible and improves flowability as compared to that of baseline, unheated tests. Delayed heating with initiation when the fuel reaches a prescribed low temperature limit, showed promise of being more efficient than continuous heating. Regardless of the mode or rate of heating, complete flowability (zero holdup) could not be restored by fuel heating. The severe, extreme-day environment imposed by the test caused a very small amount of subfreezing fuel to be retained near the tank surfaces even at high rates of heating. Correlations of flowability established for unheated fuel tests also could be applied to the heated test results if based on boundary-layer temperature or a solid index (subfreezing point) characteristic of the fuel.

Friedman, R.↗

Potential Heating Energy and Cost Savings of Dual Fuel Heat Pump Controls as a Residential Building Equipment Retrofit in the U.S.

This study investigated the energy and cost savings potential by modeling a dual fuel heat pump system with its control for a residential building in (5A) cold climate in U.S. The simulation analysis showed that the application of the DFHP system and its control to the target building can save the heating energy by 42% over a gas furnace system (baseline system). Although the HP-only system can save more heating energy (i.e.,53%) over the baseline system than DFHP system does, the DFHP with its control demonstrated the higher cost savings when a time of use electricity rate was considered.

Dual Fuel Heat Pump, Control, Residential Building↗

Benefits of Dual Fuel Heat Pump Grid-responsive Control: A Model-based Control Optimization Approach Using Building and Equipment Co-simulation

Conventional dual fuel heat pumps lack the intelligent control mechanisms to efficiently manage the switch between heat pump and furnace, leading to sub-optimal energy usage and, in some cases, increased operating costs. To resolve this gap, this study applies optimized control on hybrid heat pumps. With a focus on equipment control strategies, we compare the performances of five spacing heating equipment, including a conventional heat pump (HP), a conventional furnace, a dual fuel heat pump (DFHP) with conventional control, a dual fuel heat pump with smart control, and a novel seamlessly fuel flexible heat pump (SFFHP). While DFHP runs on either gas or electricity at any given moment, SFFHP concurrently consumes gas and electricity by continuously optimizing the proportion of each. In this research, a co-simulation framework is developed by integrating a building envelope model with a physics-based heat pump simulation model to analyze the benefits of grid-responsive controls of DFHP and SFFHP. The model-based optimal controls adjust the operation of the heat pump and gas furnace based on utility price signals and marginal grid emission to minimize utility cost and CO 2 emissions for multiple climate zones, different utility tariffs, and marginal grid emission scenarios. Case studies in Chicago and Los Angeles demonstrate that SFFHP and DFHP, with model-based optimal control, can deliver significant reductions in peak demand, utility cost, and CO 2 emission. In Chicago, SFFHP and smart controlled DFHP yield up to 64.7% and 61.7% utility cost reduction and up to 15.7% and 8.5% CO 2 emission reduction compared to the gas furnace. In Los Angeles, SFFHP and smart controlled DFHP achieve up to 43.6% and 40.1% utility cost reduction and up to 13.8% and 14.1% CO2 emission reduction compared to conventional heat pumps. In conclusion, by leveraging the fuel flexibility nature of dual fuel heat pumps, the model-based control optimization approach makes dual fuel heat pump an attractive option for demand response programs.

Control↗

Redefining fuel heating value for engines: Accounting for heat of vaporization

Defining a fuel's heating value (i.e., energy content) is fundamental for calculating engine efficiency and for life cycle analysis comparisons between different fuels. Traditional definitions of lower heating value and higher heating value account for the effect of water vapor versus liquid water in the exhaust, which is important when the fuel is used in a furnace or boiler. In an engine, it is equally important to properly account for the energy required to vaporize liquid fuel. Heat of vaporization has a small effect for common hydrocarbon fuels, typically less than 1% of lower heating value, but the effect is much larger for other important fuels such as ethanol (3.4% of lower heating value) and methanol (5.9% of lower heating value). This paper defines a new type of fuel heating value that more accurately reflects the useful fuel energy content for engines. Vaporized heating value is defined as the heating value when starting with a vaporized fuel instead of a liquid fuel. It can be calculated by adding the fuel's heat of vaporization to the traditional lower heating value. This paper illustrates the rationale and benefits of using vaporized heating value using data from the literature.

09 BIOMASS FUELS↗

Particulate Emissions Hazards Associated with Fueling Heat Engines

All hydrocarbon- (HC-) fueled heat engine exhaust (tailpipe) emissions (<10 to 140 nm) contribute as health hazards, including emissions from transportation vehicles (e.g., aircraft) and other HC-fueled power systems. CO2 emissions are tracked, and when mapped, show outlines of major transportation routes and cities. Particulate pollution affects living tissue and is found to be detrimental to cardiovascular and respiratory systems where ultrafine particulates directly translocate to promote vascular system diseases potentially detectable as organic vapors. This paper discusses aviation emissions, fueling, and certification issues, including heat engine emissions hazards, detection at low levels and tracking of emissions, and alternate energy sources for general aviation.

Hendricks, Robert C.↗

Experimental Study of Fuel Heating at Low Temperatures in a Wing Tank Model, Volume 1

Scale model fuel heating systems for use with aviation hydrocarbon fuel at low temperatures were investigated. The effectiveness of the heating systems in providing flowability and pumpability at extreme low temperature when some freezing of the fuel would otherwise occur is evaluated. The test tank simulated a section of an outer wing tank, and was chilled on the upper and lower surfaces. Turbine engine lubricating oil was heated, and recirculating fuel transferred the heat. Fuels included: a commercial Jet A; an intermediate freeze point distillate; a higher freeze point distillate blended according to Experimental Referee Broadened Specification guidelines; and a higher freeze point paraffinic distillate used in a preceding investigation. Each fuel was chilled to selected temperature to evaluate unpumpable solid formation (holdup). Tests simulating extreme cold weather flight, without heating, provided baseline fuel holdup data. Heating and recirculating fuel increased bulk temperature significantly; it had a relatively small effect on temperature near the bottom of the tank. Methods which increased penetration of heated fuel into the lower boundary layer improved the capability for reducing holdup.

Stockemer, F. J.↗

INITIAL EXPLORATION OF A NOVEL TRANSIENT ARREST SYSTEM INVOLVING FUEL HEATING

A preliminary analysis on a novel accident response system to diminish the severity of supercritical transients was conducted. The novel accident response system, called the instant shock arrest system, involves using electricity to heat the nuclear fuel at the onset of a large accidental reactivity insertion. This system is specifically designed for reactors with metallic fuel, such that the fuel is capable of conducting electricity, and being resistively heated. A reactor dynamics model of the advanced test reactor was created using the point kinetics equations and a linear reactivity feedback model to simulate how the system would effect the maximum fuel temperatures experienced during the transient. Transients with the instant shock arrest system were compare to those without it. It was found that the instant shock arrest system initially heated the fuel more than the unaffected transient but the negative reactivity inserted from such heating was enough to lower the maximum fuel temperature experienced during the transient. After simulating six different accident scenarios with reactivity insertions ranging from 0.5 \$ to 1.3 \$, it was found that the an optimal system response could reduce peak fuel temperatures during the transient by 3.5\% to 5\%. Furthermore, discussion was given on how the optimal system response could be obtained using relatively simple numerical optimization algorithms due to the smoothness of the optimization problem.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Initial exploration of a novel transient arrest system involving fuel heating

A preliminary analysis on a novel accident response system to diminish the severity of super- critical transients was conducted. The novel accident response system, called the instant shock arrest system, involves using electricity to heat the nuclear fuel at the onset of a large accidental reactivity insertion. This system is specifically designed for reactors with metallic fuel, such that the fuel is capable of conducting electricity, and being resistively heated. A reactor dynamics model of the advanced test reactor was created using the point kinetics equations and a linear reactivity feedback model to simulate how the system would effect the maximum fuel temperatures experienced during the transient. Transients with the instant shock arrest system were compared to those without it. It was found that the instant shock arrest system initially heated the fuel more than the unaffected transient but the negative reactivity inserted from such heating was enough to lower the maximum fuel temperature experienced during the transient. After simulating six different accident scenarios with reactivity insertions ranging from 0.5 to 1.3 dollar, it was found that an optimal system response could reduce peak fuel temperatures during the transient by 3.5% to 5%. Furthermore, discussion was given on how the optimal system response could be obtained using relatively simple numerical optimization algorithms due to the smoothness of the optimization problem. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

INITIAL EXPLORATION OF A NOVEL TRANSIENT ARREST SYSTEM INVOLVING FUEL HEATING (Presentation)

A preliminary analysis on a novel accident response system to diminish the severity of supercritical transients was conducted. The novel accident response system, called the instant shock arrest system, involves using electricity to heat the nuclear fuel at the onset of a large accidental reactivity insertion. This system is specifically designed for reactors with metallic fuel, such that the fuel is capable of conducting electricity, and being resistively heated. A reactor dynamics model of the advanced test reactor was created using the point kinetics equations and a linear reactivity feedback model to simulate how the system would effect the maximum fuel temperatures experienced during the transient. Transients with the instant shock arrest system were compare to those without it. It was found that the instant shock arrest system initially heated the fuel more than the unaffected transient but the negative reactivity inserted from such heating was enough to lower the maximum fuel temperature experienced during the transient. After simulating six different accident scenarios with reactivity insertions ranging from 0.5 \$ to 1.3 \$, it was found that the an optimal system response could reduce peak fuel temperatures during the transient by 3.5% to 5%. Furthermore, discussion was given on how the optimal system response could be obtained using relatively simple numerical optimization algorithms due to the smoothness of the optimization problem.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling a generic TRISO-fueled heat pipe microreactor using SCALE: Depletion, transportation criticality, and shielding

This paper demonstrates the applicability of the SCALE code system to tristructural-isotropic (TRISO)-fueled heat pipe microreactors through depletion, transportation criticality, and shielding analyses of a generic reference design. The study conducted supports US Nuclear Regulatory Commission code readiness efforts for advanced non–light-water reactor technologies and is intended as a code capability demonstration rather than as an optimization of a specific microreactor design. The modeled reactor employs high-assay low-enriched uranium (HALEU) uranium oxycarbide (UCO) TRISO fuel and beryllium oxide (BeO) reflectors and operates at 7.5 MWth with a nominal lifetime of about 3 effective full power years. Representative cases for fresh and irradiated cores were selected to exercise SCALE methods relevant to reactor operation and post-irradiation transport. The discharged-core decay heat is approximately 6% of operating power immediately after shutdown. Transportation criticality calculations show that internal water ingress is the dominant reactivity effect, with fully flooded fresh core and irradiated core configurations remain above the subcriticality criterion, even with the available control mechanisms. Shielding calculations for a simplified transportation package indicate that normal-condition dose rates are governed mainly by shielding thickness and cooling time, whereas the breached hypothetical accident case is governed primarily by cooling time. Overall, the study shows that SCALE supports depletion, transportation criticality, and shielding evaluations efficiently for TRISO-fueled heat pipe microreactors within a single code system.

Criticality↗

Decarbonization of Liquid Heating Fuels

Annually, residential and commercial buildings use about 5 billion gallons (18.9 billion liters) of distillate fuel for space and water heating. There is considerable interest in decarbonizing these markets through a combination of heat pumps and a future, carbon-free grid. An alternate approach that offers rapid and cost effective decarbonization involves substitution of low-carbon biofuels for fossil fuels within this market. Heating fuel marketers in North America and Europe are aggressively moving to achieve market penetration of biofuels. Processes for this include fuel specification standards, development of manufacturer-approved burners and all system components, development of standards for equipment listing, installation code changes, and generation of performance data. There has been considerable progress in these areas and each of these are reviewed in this paper. Currently, the most important biofuel for this market is biodiesel with a U.S. production capacity of 2.4 billion gallons (9.1 billion liters) and approximately a 75% reduction in GHG emissions. The biodiesel industry has stated a vision for dramatic increases in biodiesel production over the next decades. Fuel and equipment standards are in place to enable use of biodiesel blends to 20% and this blend is now widely used. Standard changes to extend this to as high as 100% biodiesel are nearing completion. Several states have implemented requirements for minimum levels of biodiesel in heating oil with these levels increasing over time.

09 BIOMASS FUELS↗

ResStock Measure Documentation: Dual Fuel Heat Pump

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Dual Fuel Heat Pump" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fuel Heating System Design and Thermal Modeling for Aviation Combustion Research

Aviation fuels offer substantial heat-sink capability that can be applied to aircraft thermal-management strategies and advanced propulsion-system concepts. Accurate control of fuel temperature is critical for understanding combustion behavior and supporting high temperature fuel experimental studies. This work describes the modeling and experimental validation of a portable, high temperature fuel-conditioning system designed for multiple NASA Glenn Research Center’s combustion facilities. The system utilizes a circulating-oil heating unit and modular tube-in-tube heat exchangers capable of conditioning Jet-A to temperatures approaching 600 K. A Thermal Desktop model was created to analyze heat exchanger configurations and predict performance across a range of operating conditions. Model predictions were compared with measurements collected in the CE-13C test facility, showing good agreement across the tested flow range except at low fuel flow rate around 2 kg/hr. Results provide guidance for sizing future fuel heating system for combustion research applications.

Jet fuel heating system↗

Utilization of an Advanced Sensor network to determine fuel heating value and Real-Time net unit heat rate during transient operation

Coal-fired utility boilers are being increasingly used as variable electricity generation to resolve the imbalance in the energy market from the expansion of intermittent renewable energy. The frequent transient operation required to meet residual energy demand has created a challenge for coal-fired units to operate efficiently. This work utilizes an advanced sensor network (ASN) to calculate net unit heat rate (NUHR) of a coal-fired boiler in real time through combustion calculations and statistical correlations to provide the tools for optimizing dynamic operation. Real-time heating values that were necessary to determine fuel input energy to calculate accurate NUHR were found using both fundamental and data-driven methods. Real-time NUHR shows distinct shifts that reflect changes in process conditions that will improve the ability to optimize transient operation. Data-driven heating value correlations had 24% lower root mean square error (RMSE) than the fundamental combustion calculation approach when compared to daily retrospective proximate analysis. Furthermore, the data-driven method RMSE improved by 7% with the inclusion of ASN data. Future work is to validate by comparing unit performance with and without the inclusion of NUHR as a control parameter for the dynamic neural network.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗