Search NASA⌕ Search

SEARCH · Search NASA

Results for “heavy ion beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Depth-dose relations for heavy ion beams

Radiation transport of heavy ions in matter is of interest to radiological protection in space and high-altitude aircraft. In addition, heavy ion beams are expected to be of advantage in radiotherapy since their characteristic Bragg curve allows a relative reduction of the dose in reaching a tumor site and the near elimination of exposure beyond the tumor region as the beam exits the body. Furthermore, the radioresistance of tumorous cells due to their hypoxic state may be reduced or eliminated by the high specific ionization of heavy ion beams. The depth-dose distribution of heavy ion beams consists of energy deposited by the attenuated primary beam with its characteristic Bragg curve and a relatively unstructured background due to secondary radiations produced in nuclear reactions. As the ion mass increases, the secondary contribution becomes more structured and may add significantly to the Bragg peak of the primary ions. The result for heavy ions (z greater than 20) is a greatly broadened Bragg peak region, especially in comparison to straggling effects, which may prove to be of importance in radiotherapy and biomedical research.

Wilson, J. W.↗

Heavy ion beams in extended materials - Computational methods and experiment

The transport of heavy ion beams in extended materials is a problem of interest in accelerator and space shielding, radiation therapy, and astrophysical and radiobiological studies. The beam particles change their energy and direction of motion through atomic/molecular collisions and undergo occasional radical transformation in nuclear collision. In health physics applications, a heavy ion beam of initially well defined radiation quality is transformed into a complex mixture of diverse quality components after passing through a modest amount of material. This transformation of radiation quality must be understood to adequately explain the biological response of tissue to heavy ion radiation. A theoretical/experimental program to define an ion beam and its products in extended matter is described.

Wilson, J. W.↗

Electromagnetic instabilities driven by cool heavy ion beams

The effects of the mass and density of cool, heavy ion beams on the linear and nonlinear characteristics of right-hand resonant and nonresonant electromagnetic ion beam instabilities are analyzed. The magnetic helicity and Alfven speed for a computer simulated complete linear dispersion equation for electromagnetic instabilities are examined. The data reveal that the maximum growth rate of the resonant mode and the threshold velocity of the nonresonant mode decrease with beam mass; however, the maximum growth rate of the nonresonant mode and the threshold velocity of the resonant mode are independent of the beam mass. The role reversal of the instabilities which occur when a heavy ion beam is the more dense component is studied. The nonlinear behavior of the instabilities is described; variations in the magnetic field fluctuation levels and the beam mass dependence are investigated. It is observed that at low beam density the magnetic field fluctuation level increases with beam mass and at higher beam density the fluctuation level correlates with the core mass. The instability data are applied to observations of Venus and the Comet Giacobini-Zinner.

Winske, D.↗

Harvesting 88 Zr from heavy-ion beam irradiated tungsten at the National Superconducting Cyclotron Laboratory

Tungsten is a commonly used material at many heavy-ion beam facilities, and it often becomes activated due to interactions with a beam. Many of the activation products are useful in basic and applied sciences if they can be recovered efficiently. In order to develop the radiochemistry for harvesting group (IV) elements from irradiated tungsten, a heavy-ion beam containing 88 Zr was embedded into a stack of tungsten foils at the National Superconducting Cyclotron Laboratory and a separation methodology was devised to recover the 88 Zr. The foils were dissolved in 30% hydrogen peroxide, and the 88 Zr was chemically purified from the tungsten matrix and from other co-implanted radionuclides (such as 85 Sr and 88 Y) using strong cation-exchange (AG MP-50) chromatographic resin in sulfuric acid media. The procedure provided 88 Zr in approximately 60 mL 0.5 M sulfuric acid with no detectable radio-impurities. The overall recovery yield for 88 Zr was (92.3 ± 1.2)%. In conclusion, this proof-of-concept experiment has facilitated the development of methodologies to harvest from tungsten and tungsten-alloy parts that are regularly irradiated at heavy-ion beam facilities.

07 ISOTOPE AND RADIATION SOURCES↗

Improvement in the spatial resolution of heavy ion beam probe measurements through application of ion optics

A technique for more accurately modeling and improving the spatial resolution of heavy ion beam probe measurements is described. We use a set of particle trajectories to numerically determine the focusing properties of a complicated three-dimensional magnetic field and characterize those properties with a transfer matrix. We then modify the transfer matrix approach of traditional ion optics to include a parameter that describes the ionization location of the detected ions. The ion optics model calculated using this technique enables a more accurate description of the particle trajectories than previously feasible. The model also allows one to easily determine an initial beam focus that could be used during experimental operation to optimize the spatial resolution of measurements. The technique has been applied to the design of a heavy ion beam probe diagnostic for the Wendelstein 7-X stellarator and improvements in the modeled spatial resolution by a factor of about 2 over previous estimates are possible. As a result, the improved spatial resolution will enable measurements of plasma fluctuations with smaller wavelengths than would otherwise be possible.

43 PARTICLE ACCELERATORS↗

Rate-induced aging effects on Parallel-Plate Avalanche Counter (PPAC) caused by heavy ion beams

The Facility for Rare Isotope Beams (FRIB) is one of the premier scientific user facilities for nuclear science with radioactive beams, capable of producing most (approximately 80%) of the isotopes expected to exist, from oxygen to uranium, at energies up to 200 MeV/u. With the increase in beam power from the present 10 kW to the planned 400 kW, FRIB experiments are about to enter a new era. An unprecedented rate capability as well as stable performance of all the planned instrumentation intended for beam diagnostics and beam tuning is required at the expected high beam intensities (> 1 MHz). A summary of aging phenomena at high heavy-ion beam rates observed in the Advanced Rare Isotope Separator (ARIS) detectors for beam diagnostics, including Parallel Plate Avalanche Counters (PPAC) and plastic scintillation for time-of-flight measurements, is discussed. Current research and development project to mitigate rate-induced aging are presented.

Aging effects↗

Cellular track model for study of heavy ion beams

Track theory is combined with a realistic model of a heavy ion beam to study the effects of nuclear fragmentation on cell survival and biological effectiveness. The effects of secondary reaction products are studied as a function of depth in a water column. Good agreement is found with experimental results for the survival of human T-l cells exposed to monoenergetic carbon, neon, and argon beams under aerobic and hypoxia conditions. The present calculation, which includes the effect of target fragmentation, is a significant improvement over an earlier calculation because of the use of a vastly improved beam model with no change in the track theory or cellular response parameters.

Shinn, Judy L.↗

Heavy ion beam probe measurements of radial potential profiles in the modified Penning discharge

A heavy ion beam probe was used to examine the radial potential profile of a plasma in the modified Penning discharge. The plasma has strong (approximately kV) electrostatic potentials near the anode ring which can be a large fraction of the injected ion beam energy. A primary (singly ionized) thallium ion beam is injected through the plasma in the midplane of a double Penning anode ring. After passage through the plasma, primary and secondary (doubly ionized) ions are detected with either a set of flat probes or an electrostatic energy analyzer. A calculation of the primary orbit through the plasma is performed to obtain an approximation to the measured primary beam trajectory. As the real radial potential profile is unknown, an adjustable model is used in the computer program. The adjustable potential profile is varied until the best agreement between measured and calculated trajectories is obtained. Secondary orbits are also predicted using the best fitting adjustable profile. The calculations indicate that secondary beams originating at more than one point in the plasma can be simultaneously observed at the electrostatic analyzer with certain primary beam initial conditions.

Kambic, G. X.↗

Fast switching magnet for heavy ion beam separation

This paper presents the design for a switching magnet capable of deflecting 6.5 MeV/u heavy-ion beams with mass-to-charge ratio of 7 by 10 degrees. This magnet can produce variable flat-top pulses from 1 to 30 ms with rise and fall times of less than 0.5 ms at a variable duty cycle of 3–91% into a heavily inductive load. The magnet has a laminated, iron dominated, H-shaped core. Directly-cooled copper pancake coils energize the magnet. We present the magnet design considerations, including the results of extensive computer modeling. Finally, we also present the conceptual engineering design and the studies of magnet yoke fabrication.

47 OTHER INSTRUMENTATION↗

Heavy ion beam probe for Wendelstein 7-X measurement capabilities as projected through its design

A heavy ion beam probe (HIBP) diagnostic is being developed for studies of plasma equilibrium and turbulence in the optimized Wendelstein 7-X (W7-X) stellarator. Operation of W7-X has experimentally demonstrated that its optimized magnetic field results in improved neoclassical particle confinement and, as a result, turbulence is the predominant cause of energy transport. The HIBP will have the unique ability to provide experimental data needed to complement models of both neoclassical and turbulent transport. It will acquire direct measurements in the W7-X plasma interior of the electric potential (needed for understanding ambipolar particle flux) and fluctuations of electron density and potential (needed for understanding turbulence). The HIBP for W7-X will inject singly charged ion beams with energies of up to 2 MeV and is designed to access the upper cross section of the W7-X plasma. We use trajectory simulations to illustrate the plasma coverage that the diagnostic can achieve in the reference magnetic configurations of W7-X. We calculate beam signal levels, discuss anticipated measurement sensitivity of broadband fluctuations of electron density and plasma potential, and show how they depend on plasma density. We also discuss the diagnostic sensitivity to equilibrium plasma potential.

Instruments & Instrumentation↗

One dimensional heavy ion beam transport: Energy independent model

Attempts are made to model the transport problem for heavy ion beams in various targets, employing the current level of understanding of the physics of high-charge and energy (HZE) particle interaction with matter are made. An energy independent transport model, with the most simplified assumptions and proper parameters is presented. The first and essential assumption in this case (energy independent transport) is the high energy characterization of the incident beam. The energy independent equation is solved and application is made to high energy neon (NE-20) and iron (FE-56) beams in water. The numerical solutions is given and compared to a numerical solution to determine the accuracy of the model. The lower limit energy for neon and iron to be high energy beams is calculated due to Barkas and Burger theory by LBLFRG computer program. The calculated values in the density range of interest (50 g/sq cm) of water are: 833.43 MeV/nuc for neon and 1597.68 MeV/nuc for iron. The analytical solutions of the energy independent transport equation gives the flux of different collision terms. The fluxes of individual collision terms are given and the total fluxes are shown in graphs relative to different thicknesses of water. The values for fluxes are calculated by the ANASTP computer code.

Farhat, Hamidullah↗

Conceptual design of a heavy ion beam probe diagnostic for the Wendelstein 7-X Stellarator

This article describes the current state of the design of the heavy ion beam probe (HIBP) for Wendelstein 7-X (W7-X). It will be the first HIBP diagnostic on an optimized stellarator and is designed to study electric fields and ion scale turbulence in all W7-X reference magnetic configurations. The use of an existing 2 MV accelerator, located outside of the torus hall, results in the need for a circuitous primary beamline. This increases the complexity of the ion optics design to deliver a focused beam to the plasma. To access most of the magnetic configuration space of W7-X, the secondary beamline and an energy analyzer are designed to pivot, thereby redirecting a wider range of secondary beam trajectories. Signal level estimates indicate that the equilibrium potential can be measured at all radii and that the radial coverage for potential and density fluctuations measurements depends on the plasma density.

47 OTHER INSTRUMENTATION↗

First Simultaneous Acceleration of Multiple Charge States of Heavy Ion Beams in a Large-Scale Superconducting Linear Accelerator

Experimental studies of the simultaneous acceleration of three-charge-state 129 Xe 49+,50+,51+ beam from 17 to 180 MeV/nucleon in a superconducting linear accelerator are presented. The beam parameters for each individual- and multiple-charge-state beam were measured and compared with the particle tracking simulations. Detailed measurements were performed to characterize the multiple-charge-state beam’s recombination after a second-order achromat and isopath 180° bending system. As a result of the recombination of three charge states in the six-dimensional phase space, the xenon beam intensity was increased by 2.5-fold compared to the single-charge-state beam. Lastly, the results presented in the Letter fully validate the possibility to produce and utilize high-quality multiple-charge-state heavy-ion beams in a large-scale superconducting linac to increase the available beam power on an isotope production target.

43 PARTICLE ACCELERATORS↗

Evaluation of risk from space radiation with high-energy heavy ion beams

The most challenging radiation in space consists of fully ionized atomic elements with high energy for which only the few lowest energy ions can be stopped in shielding materials. The health risk from exposure to these ions and their secondary radiations generated in shield materials is poorly understood since there are few human data and a systematic study in relevant animal model systems has not been made. The accuracy of risk prediction is described as the major limiting factor in the management of space radiation risk. The expected impact of systematic studies is examined using the limited available biological data and models. Given the limitations of current predictions, models must be developed that are able to incorporate the required fundamental scientific data into accurate risk estimates. The important radiation components that can be provided for laboratory testing are identified. The use of ground-based accelerator beams to simulate space radiation is explained and quantitative scientific constraints on such facilities are derived. Three facilities, one each in the United States, in Germany and in Japan, currently have the partial capability to satisfy these constraints. A facility has been proposed using the Brookhaven National Laboratory Booster Synchrotron in the United States; in conjuction with other on-site accelerators, it will be able to provide the full range of heavy ion beams and energies required.

NASA Discipline Radiation Health↗

Heavy ion beam physics at Facility for Rare Isotope Beams

The Facility for Rare Isotope Beams (FRIB) will be the world's premier rare-isotope beam facility. Experiments with the majority (~80%) of the isotope predicted to exist will become available. The FRIB facility is based on a superconducting (SC) heavy ion linac with output energy above 200 MeV/u for any ions at beam power of 400 kW. FRIB includes a target facility for in-flight production of rare isotopes. A three-stage fragment separator will be used to prepare fast rare isotope beams with high-purity for nuclear physics experiments. The installation work of the accelerator and experimental systems is approaching completion and multi-stage beam commissioning activities started in summer 2017 with expected project completion in early 2022. In conclusion, the commencement of operation for users' experiments is planned immediately following the project completion.

43 PARTICLE ACCELERATORS↗

Parallel-plate avalanche counters for heavy-ion beam tracking: History and mysteries

Despite being an old detector concept, position-sensitive parallel-plate avalanche counters (PPACs) remain widely used today for heavy-ion position and timing measurements. In modern rare isotope beam facilities and large-acceptance fragment separators, PPACs are used to characterize beam properties (diagnostics), facilitate beam delivery (tuning), and provide event-by-event beam tracking for particle identification (PID). Most popular particle localization methods in PPAC detectors are based on strip electrodes electrically connected to resistive-chain circuits or delay lines. More exotic systems include optical readouts based on recording electroluminescence light with high-granularity photodetector arrays or high-resolution resistive anode electrodes. PPACs with conventional resistive-chain or delay-line readouts achieve typical position and time resolutions of below 1 mm ( σ ) and around 150 ps ( σ ), respectively. In addition, delay-line systems are capable of counting rates above several hundred kHz for beam areas of a few millimeters square, and around 1 MHz for larger beam sizes. Resistive-chain readouts have limited rates of a few tens of kHz. A review of the operation principles and performance of PPAC detectors is presented in this paper. We will discuss decades-long experience building and operating PPACs developed at the National Superconducting Cyclotron Laboratory, and then refined at the Facility for Rare Isotope Beams (FRIB), mostly focusing on the delay-line readout technique (DLPPAC). We will also discuss problems that arise due to electric discharges at high rates and briefly describe ongoing developments at FRIB. Published by the American Physical Society 2024

Physics↗

Position measurements for heavy ion beams using a sodium iodide scintillator

A 50 cm diameter, 1.7 cm thick disc of NaI scintillator has been mounted to permit edge viewing by four photomultipliers. Energetic heavy ions passing through the scintillator at different positions cause a variation in the division of light among the photomultipliers. A performance close to the expected limit for 670 MeV/n neon has been achieved. Calculations of expected response using an optical model agree well with the measurements.

Buffington, A.↗