Search NASA⌕ Search

SEARCH · Search NASA

Results for “heavy metals detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The crystal facet-dependent electrochemical performance of TiO 2 nanocrystals for heavy metal detection: Theoretical prediction and experimental proof

Tailored design/fabrication of electroanalytical materials with highly-active exposed crystal planes is of great importance for the development of electrochemical sensing. In this work, combining experimental and theoretical efforts, we reported a facile strategy to fabricate TiO 2 nanocrystals with tunable electrochemical performance for heavy metal detection. Density functional theory (DFT) calculations indicated that TiO 2 (001) facet showed relative larger adsorption energy and lower diffusion energy barrier toward heavy metal ions, which is favorable for obtaining better electrochemical stripping behaviors. Based on this prediction, a series of TiO 2 nanocrystals with different ratios of exposed (001) and (101) facets were synthesized. Electrochemical stripping experiments further demonstrated that with the increase of the percentage of exposed (001) facet, the sensitivity toward Pb(II) and Cd(II) was increased accordingly. When the percentage of exposed (001) facet was increased from 7% to 80%, the sensitivity increased by 190% and 93% for Pb(II) and Cd(II), respectively. In conclusion, our work provides an effective route to construct advanced electroanalytical materials for sensing.

47 OTHER INSTRUMENTATION↗

Transversely Excited Atmospheric CO{sub 2} Laser-Induced Plasma Spectroscopy for the Detection of Heavy Metals in Soil

A rapid detection of heavy metals in soil was presented by the metal-assisted gas plasma method using specific characteristics of a pulsed, transversely excited atmospheric (TEA) CO{sub 2} laser. The soil particles were placed in a hole made of acrylic plate. The sample was covered by a to prevent the soil particles from being blown off. The mesh also functioned to initiate a luminous plasma. When a TEA CO{sub 2} laser (1500 mJ, 200 ns) was focused on the soil sample, passing through the metal mesh, some of the laser energy was used to generate the gas plasma on the mesh surface, and the remaining laser energy was employed to ablate the soil particles. The fine, ablated soil particles moved into the gas plasma region to be dissociated and excited. Using this technique, analysis can be made with reduced sample pretreatment, and therefore a rapid analysis can be performed efficiently. The results proved that the signal to noise ratio (S/N) of the emission spectral lines is much better for the case of the present method (mesh method) compared to the case of standard laser-induced breakdown spectroscopy using the pellet method. Rapid detection of heavy metal elements in soil has been successfully carried out. The detection limits of Cu and Hg in soil were estimated to be 3 and 10 mg/kg, respectively. The present method has good potential for rapid and sensitive detection of heavy metals in soil samples.

54 ENVIRONMENTAL SCIENCES↗

Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell

In this study, we present multiplexed anodic stripping voltammetry (ASV) detection of heavy metal ions (HMIs)—As(III), Cd(II), and Pb(II)—using a homemade electrochemical cell consisting of dual working, reference and counter screen-printed electrodes (SPE) on polyimide substrate integrated with a 3D-printed flow cell. Working and counter electrodes were fabricated by the screen-printing of graphite paste while the Ag/AgCl paste was screen-printed as a reference electrode (Ag/AgCl quasi-reference electrode). The working electrodes were modified with (BiO) 2 CO 3 -reduced graphene oxide (rGO)-Nafion [(BiO) 2 CO 3 -rGO-Nafion] and Fe 3 O 4 magnetic nanoparticles (Fe 3 O 4 MNPs) decorated Au nanoparticles (AuNPs)-ionic liquid (IL) (Fe 3 O 4 -Au-IL) nanocomposites separately to enhance HMIs sensing. Electrochemical detection was achieved using square wave ASV technique. The desired structure of the flow electrochemical cell was optimized by the computational fluid dynamic (CFD). Different experimental parameters for stripping analysis of HMIs were optimized including deposition time, deposition potential and flow rate. The linear range of calibration curves with the sensing nanocomposites modified SPE for the three metal ions was from 0–50 μg/L. The limits of detection (S/N = 3) were estimated to be 2.4 μg/L for As(III), 1.2 μg/L for Pb(II) and 0.8 μg/L for Cd(II). Furthermore, the homemade flow anodic stripping sensor platform was used to detect HMIs in simulated river water with a 95–101% recovery, indicating high selectivity and accuracy and great potential for applicability even in complex matrices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface-Enhanced Raman Scattering Optophysiology Nanofibers for the Detection of Heavy Metals in Single Breast Cancer Cells

Mercury(II) ions (Hg2+) and silver ions (Ag+) are two of the most hazardous pollutants causing serious damage to human health. Here, we constructed surface enhanced Raman scattering (SERS)-active nanofibers covered with 4-mercaptopyridine (4-Mpy)-modified gold nanoparticles (AuNPs) to detect Hg2+ and Ag+. Experimental evidence suggests that the observed spectral changes originate from the combined effect of (i) the coordination between the nitrogen on 4-Mpy and the metal ions and (ii) the 4-Mpy molecular orientation (from flatter to more perpendicular with respect to the metal surface). The relative intensity of a pair of characteristic Raman peaks (at ~428 and ~708 cm-1) was used to quantify the metal ion concentration, greatly increasing the reproducibility of the measurement compared to signal-on or signal-off detection based on a single SERS peak. The detection limit of this method for Hg2+ is lower than that for the Ag+ (5 nM vs 100 nM), which can be explained by the stronger interaction energy between Hg2+ and N compared to Ag+ and N, as demonstrated by density functional theory (DFT) calculations. The Hg2+ and Ag+ ions can be masked by adding ethylenediaminetetraacetate (EDTA) and Cl-, respectively, to the Hg2+ and Ag+ samples. The good sensitivity, high reproducibility and excellent selectivity of these nanosensors were also demonstrated. Furthermore, detection of Hg2+ in living breast cancer cells at the subcellular level is possible thanks to the nanometric size of the herein described SERS nanosensors, allowing high spatial resolution and minimal cell damage.

Zhao, Xingjuan↗

Nanomaterial-Treated Filters for the Uptake of Heavy Metals from Water Sources

We describe the synthesis and properties of ligand-modified gold nanoparticles (AuNPs) grown on stainless steel wool filters. Their selectivity and efficiency with regards to heavy metal uptake from groundwater and other sources of drinking water found at or near DOE facilities were also investigated. The nanomaterial-treated filters are advantageous because they serve as inactive supports that allow for efficient flow of the contaminated water, and can be easily replaced after heavy metal uptake. They are also comparable to nanomaterials free in solution with regards to the effectiveness of remediation of drinking water. Environmental stewardship is at the forefront of core competencies at SRNS. This includes treatment and remediation of contaminated groundwater. Among contaminants present in water resources, hazardous heavy metals and radioactive contaminants are the main concerns in the DOE complex. With the advent of nanotechnology, new remediation technologies have emerged. AuNPs have unique optical properties and enormous surface areas, making them good candidates for water remediation. They can be functionalized with ligands, e.g. citrate and L-cysteine, allowing them to serve as an excellent platform for environmental stewardship applications. Objectives: 1. Nanomaterial development and characterization Ligand-modified AuNPs: (a) in solution and (b) on stainless steel wool filters 2. Nanomaterial evaluation for efficiency and selectivity of heavy metal uptake, including Cu{sup 2+} and Zn{sup 2+}. Materials and Methods: Chloroauric acid (HAuCl{sub 4}), sodium citrate (reducing and capping agent); Stainless steel wool (SSW) was used as a support and filter; L-cysteine- ligand for surface functionalization; Zinc acetate and copper nitrate: heavy metal ions contaminants. Au NPs were prepared by wet chemistry methods. They were characterized by UV-Vis, Zeta sizer and potential, SEM, EDS and EDS mapping to understand their physico-chemical properties. Results and Discussions: Surface modification of AuNPs with surfactants changes their optical properties. Citrate capped AuNPs demonstrate high loading capacity for both heavy metals. L-cysteine capped AuNPs demonstrate high loading capacity for Zn{sup 2+}. Citrate capped AuNPs have excellent sensitivity towards heavy metal ions (0.05 mM can be detected). L-cysteine capped AuNPs can detect heavy metal ions at low concentrations, making them useful for sensing. Conclusions: AuNPs in solution and on SSW were successfully synthesized and characterized. Two functional sensing and remediation technologies - colorimetric sensor and AuNP-treated filters - were developed through wet chemistry methods. AuNP SSW filters exhibit different characteristics (size, shape, etc.) than AuNPs in solution and are efficient at the uptake of heavy metal ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrical sensing, tracking, and actuation of droplets

Devices, techniques, and processes are disclosed that use electrical impedance to detect of the presence and contents of droplets including cells, nucleic acids, proteins, or solute concentrations in an array of retrievable, trackable, trapped droplets in a fluidic system. Electrodes may be positioned underneath individual droplet traps in a microchannel to assay droplet contents and/or actuating droplets for the release of the droplets from corresponding traps. The disclosed technology may be used for detection of the results of solvent extraction processes including time-dependent quantification of metal ion concentration in the aqueous and organic phases, for wastewater treatment, heavy metal detection, pharmaceutical industry, and/or biotechnology, or for environmental monitoring of wastewater for toxic metal, monitoring of biological cell viability and proliferation, monitoring of extraction processes used in heavy metal mining, monitoring of extraction processes used in nuclear fuel processing, monitoring kinetics of enzyme processes, and/or assessing pharmacodynamics and drug efficacy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A novel optical sensor for Pb 2+ detection based on in-situ formation of Ruddlesden-Popper phase (C 4 H 9 NH 3 ) 2 PbBr 4 perovskite

On account of the concentration sensitive photoluminescence (PL) property of the lead-based Ruddlesden-Popper (RP) phase perovskite material, a novel sensing mechanism for highly selective Pb 2+ detection based on the in-situ formation of highly emissive luminescence structure matrix (C 4 H 9 NH 3 ) 2 PbBr 4 has been demonstrated. The sensor exhibits high sensitivity and selectivity for detecting Pb 2+ in complex metal cations mixture solution. This research reports a novel type of sensor mechanism based on the in-situ formation of luminescent lead-based RP phase perovskite. Here, it paves the way for developing highly selective optical sensors for detecting heavy metal cations via their corresponding luminescence structure matrix.

36 MATERIALS SCIENCE↗

Heavy metal imprints in Antarctic snow from research and tourism

Antarctica, long regarded as one of the last pristine environments on Earth, is increasingly affected by human activity. As tourism surges and scientific operations expand, air pollution from local emissions is raising new environmental concerns. Here, in this study, we analyze surface snow samples collected along a ~2,000 km transect, from the South Shetland Islands (62°S) to the Ellsworth Mountains (79°S), to map the geochemical fingerprints of aerosol deposition. We identify distinct spatial patterns shaped by crustal, marine, biogenic, and anthropogenic sources. Notably, we detect heavy metal imprints in the snow chemistry of the northern Antarctic Peninsula, where major research stations are concentrated and marine tourism traffic is most intense. Our findings shed light on the extent of the impacts from energy-intensive local activities in Antarctica, underscoring the need for enhanced environmental monitoring and sustainable management strategies in this fragile region.

Cordero, Raúl R. [Univ. of Groningen, Leeuwarden (↗

Results of the Aerosol Sampling Experiment on the International Space Station

The indoor air quality of the International Space Station (ISS), in terms of particulate matter, has been assessed through a sampling experiment that collected airborne debris for return to Earth. The Aerosol Sampling Experiment took place on ISS in December 2016 and January 2017, with sample return in February 2017. For redundancy, two different aerosol samplers collected particles in two size ranges spanning from 10 nm to hundreds of micrometers. Multiple analysis techniques have been used to characterize the particles, such as reflective light microscopy, manual scanning electron microscopy (SEM) analysis (secondary and backscattered imaging) with energy dispersive spectroscopy (EDS) x-ray analysis, computer controlled scanning electron microscopy (CCSEM) and Raman spectroscopy. Sampling took place in five locations on ISS, with the greatest deposition of particles in Node 3, followed by Node 1, the US Lab and Node 2. The PMM had very few airborne particles, as expected, owing to the lack of human presence. A large proportion of the sampled material consisted of fibers from clothing. Many particles had complex morphologies or contained multiple metals in a carbonaceous matrix. Metal particles were analyzed for each sampling location in terms of both weight and number percent, with 27 heavy metals detected. Fiberglass and TiO2 particles were present in every location. Quantitative analysis results are presented, and where possible, particle emission sources are identified with the intention to fuel discussions on mitigation.

Meyer, Marit E.↗

Bismuth Subcarbonate Decorated Reduced Graphene Oxide Nanocomposite for the Sensitive Stripping Voltammetry Analysis of Pb(II) and Cd(II) in Water

In this paper, bismuth subcarbonate (BiO)2CO3-reduced graphene oxide nanocomposite incorporated in Nafion matrix ((BiO)2CO3-rGO-Nafion) was synthesized and further applied, for the first time, in the sensitive detection of Pb(II) and Cd(II) by square-wave anodic stripping voltammetry (SWASV). The as-synthesized nanocomposites were characterized by energy-dispersive spectroscopy (EDS), Raman spectroscopy, scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). (BiO)2CO3 composite plays a key role in the improvement of the detection sensitivity, which can form multicomponent alloy with cadmium and lead. Additionally, the unique structure of rGO can enlarge the surface area and provide abundant active sites. Moreover, Nafion incorporation in the nanocomposite can effectively increase the adhesion and mechanical strength of the film, and further improve the preconcetration ability due to the cation-exchange capacity of its abundant sulfonate groups. As expected, the (BiO)2CO3-rGO/Nafion nanocomposite-modified glassy carbon electrode ((BiO)2CO3-rGO-Nafion/GCE) achieved low detection limits of 0.24 μg/L for Pb(II) and 0.16 μg/L for Cd(II), in the linear range of 1.0–60 μg/L, and showed some excellent performance, such as high stability, good selectivity, and sensitivity. Finally, synthetic water samples were prepared and further used to verify the practicability of the (BiO)2CO3-rGO-Nafion/GCE with satisfactory results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A spring window for geobotanical anomaly detection

The observation of senescence of deciduous vegetation to detect soil heavy metal mineralization is discussed. A gridded sampling of two sites of Quercus alba L. in south-central Virginia in 1982 is studied. The data reveal that smaller leaf blade lengths are observed in the soil site with copper, lead, and zinc concentrations. A random study in 1983 of red and white Q. rubra L., Q. prinus L., and Acer rubrum L., to confirm previous results is described. The observations of blade length and bud breaks show a 7-10 day lag in growth in the mineral site for the oak trees; however, the maple trees are not influenced by the minerals.

Bell, R.↗

A biosensor for cadmium based on bioconvective patterns

An 'in vitro' method for monitoring cadmium, one of the most lethal bivalent heavy metals, can detect biologically active levels. The effects of cadmium tend to concentrate in protozoa far above natural levels and therein begin transferring through freshwater food chains to animals and humans. In a small sample volume (approximately 5 ml) the method uses the toxic response to the protozoa, Tetrahymena pyriformis, to cadmium. The assay relies on macroscopic bioconvective patterns to measure the toxic response, giving a sensitivity better than 1 micro-g/1 and a toxicity threshold to 7 micro-g/1 for Cd(2+). Cadmium hinders pattern formation in a dose-dependent manner. Arrested organism growth arises from slowed division and mutation to non-dividing classes. Unlike previous efforts, this method can be performed in a shallow flow device and does not require electronic or chemical analyses to monitor toxicity.

Noever, David A.↗

Bismuth Detection in Alkaline Electrolyte via Anodic Stripping Voltammetry for Battery Separator Evaluation

Abstract Anodic stripping voltammetry (ASV) has been widely used for the detection of several heavy metal ions in neutral and acidic solution, in many cases employing electrodes and/or solutions incorporating Bi. In this work we demonstrate that Bi(OH) 4 − ion concentration can be measured in highly alkaline 8.5 M KOH solution using ASV. The addition of Pb in similar concentrations to the Bi(OH) 4 − being measured is shown to improve both the sensitivity and precision of the method. When the Pb additive is employed, a formal limit of detection of 8.5 ppb is achieved, compared to 17.3 ppb when the Pb additive is not used. Due to the use of Bi additives in alkaline battery chemistries, it follows that separators which limit Bi(OH) 4 − diffusion into the bulk electrolyte and away from the electrodes are of interest. For this purpose, we utilize ASV to determine Bi(OH) 4 − diffusion rates through Celgard 3501, cellophane 350P00, and Nafion 211. Bi(OH) 4 − crossover rates, as determined by ASV, are shown to be repeatable and consistent with expectations from the known separator structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Conducting polymer-based electrochemical sensors: Progress, challenges, and future perspectives

Conducting polymers are promising due to their unique properties, such as excellent electrical and optical properties, physical and chemical stability, high conductivity, and effective redox properties with high-temperature stability and biocompatibility. Due to these properties, conducting polymers are useful in diverse applications like sensors, batteries, oil industries, biosensors, biomedicines, catalysis, cancer treatment, etc. This review article aims to discuss the recent trends and analysis of conducting polymer-based electrochemical sensors in diverse areas with all required sensor characteristics, such as the derived limit of detection, utilized techniques for the sensing analysis and derived linear dynamic range with the stability of the sensors. Conducting polymers and their nanocomposites-based electrochemical sensors have demonstrated exceptional capabilities towards detecting various biomolecules, heavy metals, pesticides, and viruses like SARS-COV-2. Incorporation of redox mediators, use of conducting hydrogels, and molecular imprinting are promising strategies for better performance of the derived sensor. The article has demonstrated the existing challenges and limitations and provided solutions in the field. In the future, conducting polymers-based electrochemical sensors can be utilized in wearable sensors and integrated with IoT devices for better reach in real-time applications. They can also be made more accessible with precise control and data output by following specific methodologies. Utilizing green and sustainable conducting polymers can be crucial in advancing eco-friendly practices in the future. Conducting polymer-based electrochemical sensors has affectivity in neurochemical and pathogen sensing, which is essential for brain function and mental health.

42 ENGINEERING↗

Roll-to-Roll Gravure Printed Electrochemical Sensors for Wearable and Medical Devices

As recent developments in noninvasive biosensors spearhead the thrust toward personalized health and fitness monitoring, there is a need for high throughput, cost-effective fabrication of flexible sensing components. Toward this goal, in this paper we present roll-to-roll (R2R) gravure printed electrodes that are robust under a range of electrochemical sensing applications. We use inks and electrode morphologies designed for electrochemical and mechanical stability, achieving devices with uniform redox kinetics printed on 150 m flexible substrate rolls. We show that these electrodes can be functionalized into consistently high performing sensors for detecting ions, metabolites, heavy metals, and other small molecules in noninvasively accessed biofluids, including sensors for real-time, in situ perspiration monitoring during exercise. This development of robust and versatile R2R gravure printed electrodes represents a key translational step in enabling large-scale, low-cost fabrication of disposable wearable sensors for personalized health monitoring applications.

42 ENGINEERING↗