Search NASA⌕ Search

SEARCH · Search NASA

Results for “helium path”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Multi-crystal native-SAD phasing at 5 keV with a helium environment

De novo structure determination from single-wavelength anomalous diffraction using native sulfur or phospho­rus in biomolecules (native-SAD) is an appealing method to mitigate the labor-intensive production of heavy-atom derivatives and seleno­methio­nyl substitutions. The native-SAD method is particularly attractive for membrane proteins, which are difficult to produce and often recalcitrant to grow into decent-sized crystals. Native-SAD uses lower-energy X-rays to enhance anomalous signals from sulfur or phospho­rus. However, at lower energies, the scattering and absorption of air contribute to the background noise, reduce the signals and are thus adverse to native-SAD phasing. We have previously demonstrated native-SAD phasing at an energy of 5 keV in air at the NSLS-II FMX beamline. Here, the use of a helium path developed to reduce both the noise from background scattering and the air absorption of the diffracted X-ray beam are described. The helium path was used for collection of anomalous diffraction data at 5 keV for two proteins: thaumatin and the membrane protein TehA. Although anomalous signals from each individual crystal are very weak, robust anomalous signals are obtained from data assembled from micrometre-sized crystals. The thaumatin structure was determined from 15 microcrystals and the TehA structure from 18 microcrystals. These results demonstrate the usefulness of a helium environment in support of native-SAD phasing at 5 keV.

59 BASIC BIOLOGICAL SCIENCES↗

A path to scaling helium-3 spin-exchange optical pumping

Polarized 3 He has contributed to breakthroughs in particle physics, neutron scattering, and lung imaging, mostly by optical pumping of liter quantities in valved cells or in sealed cells pumped in situ. Only metastability exchange optical pumping currently meets the demand for delivering large quantities of highly polarized 3 He to external volumes. Our development program is under way to achieve medium to large-scale spin-exchange optical pumping of 3 He. Thin-walled aluminosilicate cells placed in contact with thermal reservoirs inside a pressure vessel were optically pumped with kilowatt-scale lasers spectrally narrowed to match pressure-broadened absorption linewidths. We report here the key elements of this program and significant milestones: multi-liter volume valved cells that provide long longitudinal lifetimes that reached polarization as high as 85% inside a thermally stable and pressurized environment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Formation of a Large Cold Groundwater Mantle Helium Anomaly and High Temperature Geothermal Resources in Response to Bimodal Magmatism Near Roosevelt Hot Springs and Utah FORGE, Milford Valley, Southwest Utah

Abstract A large mantle helium anomaly and separate domains of high heat flow are the predominant manifestations of bimodal magmatic activity in the Milford valley. The mantle helium anomaly (1.9–2.6 R/Ra) covers 270 km 2 and is subdivided into two separated domains: a cold shallow groundwater regime and high temperature hydrothermal activity. The zone of anomalous heat flow covers >100 km 2 and is also subdivided into two adjacent domains, comprising hydrothermal activity at Roosevelt Hot Springs (RHS) (3–7 W/m 2 ) and conductive heat flow (100–180 mW/m 2 ). While the transfer of heat and mantle helium at RHS are coupled, heat and helium transfer are decoupled in the adjacent cold groundwater regime to the west. Both the mantle helium and geothermal anomalies are attributed to recent mafic‐felsic magmatic intrusions of >400 km 3 , however, the absence of volcanic eruptions <500,000 years indicates magmas stall before rising to shallow crustal level <10 km depth. Deep level magmatism produces a felsic composition melt, which is inferred to be responsible for the widespread and near uniform range of diluted mantle helium values. A thick and impermeable mass of crystalline granitic basement rock at the mid‐crustal level divides the ascent of mantle helium into separate flow paths. It may also impede the rise of buoyant magma trapping thermal energy that facilitates partial melting, slow cooling, and development of a thick thermal aureole. Partitioning of convective and conductive thermal regimes and independent flow paths supplying deeply derived helium characterize the development of a large long‐lived magma‐related geothermal system.

Geochemistry & Geophysics↗

Numerical Modeling of Thermal Stratification in Cryogenic Propellant Tanks

Computational Fluid Dynamics (CFD) analysis is performed to investigate liquid blockage in the helium pressure line associated with the propellant (MMH) tank. If a certain amount of propellant is trapped within the helium pressure line, the question is whether the given amount of helium that is available can provide a clear helium flow path with no adverse consequences such as over pressurization of the pressure line.

Wang, Xiao-Yen↗

Helium Balloon Valve Improvement

The NASA Balloon Program Office (BPO), located at Wallops Flight Facility asked the Mechanical Systems Branch (Code 548) to improve the design of their balloon valve. BPO uses two main types of balloons, Zero Pressure Balloon (ZPB) and Super Pressure Balloon (SPB), which both use the valve. It is used for termination of the ZPB, and inflation and termination of the SPB. During launch campaigns the valve showed signs of helium leakage which lead the BPO to ask for an improvement. As part of a Professional Readiness Engineering Program (PREP), research and review of the current valve was conducted and a new design was prepared. The current custom designed valve consists of a "pie" plate that is actuated up and down via a gear rack that is driven by a globe motor. When closed the knife edge of the pie plate bites into a silicone gasket to seal the structure. Unfortunately, the gasket material permanently deforms after being compressed and the plate itself bends under the force induced by the motor, introducing two possible helium leak paths. The new custom designed valve utilizes o-rings instead of one gasket to reduce the possibility of leakage from permanent deformation. One o-ring seals the valve structure to its mating surface and a spring energized o-ring is used in a piston design to seal the valve once it's closed. The design also utilizes different materials to increase stiffness and strength so that it is less likely to bend under the force from the motor. Currently the new valve has finished the design and analysis phases and is proceeding towards manufacturing and testing.

Seo, Lindsey↗

Application of sulfur SAD to small crystals with a large asymmetric unit and anomalous substructure

The application of sulfur single-wavelength anomalous dispersion (S-SAD) to determine the crystal structures of macromolecules can be challenging if the asymmetric unit is large, the crystals are small, the size of the anomalously scattering sulfur structure is large and the resolution at which the anomalous signals can be accurately measured is modest. Here, as a study of such a case, approaches to the SAD phasing of orthorhombic Ric-8A crystals are described. The structure of Ric-8A was published with only a brief description of the phasing process [Zeng et al. (2019), Structure , 27 , 1137–1141]. Here, alternative approaches to determining the 40-atom sulfur substructure of the 103 kDa Ric-8A dimer that composes the asymmetric unit are explored. At the data-collection wavelength of 1.77 Å measured at the Frontier micro-focusing Macromolecular Crystallography (FMX) beamline at National Synchrotron Light Source II, the sulfur anomalous signal strength, |Δ ano |/σΔ ano ( d ′′/sig), approaches 1.4 at 3.4 Å resolution. The highly redundant, 11 000 000-reflection data set measured from 18 crystals was segmented into isomorphous clusters using BLEND in the CCP 4 program suite. Data sets within clusters or sets of clusters were scaled and merged using AIMLESS from CCP 4 or, alternatively, the phenix.scale_and_merge tool from the Phenix suite. The latter proved to be the more effective in extracting anomalous signals. The HySS tool in Phenix , SHELXC / D and PRASA as implemented in the CRANK 2 program suite were each employed to determine the sulfur substructure. All of these approaches were effective, although HySS , as a component of the phenix.autosol tool, required data from all crystals to find the positions of the sulfur atoms. Critical contributors in this case study to successful phase determination by SAD included (i) the high-flux FMX beamline, featuring helical-mode data collection and a helium-filled beam path, (ii) as recognized by many authors, a very highly redundant, multiple-crystal data set and (iii) the inclusion within that data set of data from crystals that were scanned over large ω ranges, yielding highly isomorphous and highly redundant intensity measurements.

59 BASIC BIOLOGICAL SCIENCES↗

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 2 – Transient modeling and pump-down path selection

Low-pressure conditions required for operation of helium cryogenic systems below the normal boiling point (i.e. 4.2 K) are established through a transient process, commonly referred to as ‘pump-down’. This process is defined as the transition from pressures above atmospheric conditions to the saturation pressure which corresponds to a specified operational temperature. The FRIB 2 K system consists of five cryogenic centrifugal compressors which are operated in series. Historically, the pump-down process path has been established through empirical methods and system operator experience. Investigation into the pump-down process at FRIB aimed to develop a pump-down methodology which relies on theoretical model predictions rather than empirically developed process paths. Ensuring stable operation during the pump-down process involved application of a centrifugal compressor performance prediction model, which is described in Part 1 of this paper. Compressor performance maps can be directly used to evaluate the stability of a selected pump-down path and anticipate the overall reliability of the selected path. In conjunction with the compressor performance maps, a system pressure model was developed to estimate the transient pressure response during the pump-down process. Lastly, an explicit equation was developed to establish a mass flow rate profile for the pump-down process. Implementation of the presented methodology (including the developed models) allows for the system operator to determine a continuous pump-down path which maintains compressor stability while conforming to overall system capabilities. Altogether, the methodology presented has resulted in simplification of transient pump-down operations and increased the reliability, stability and efficiency of the pump-down process.

Compressor train control↗

Operation of A Sunpower M87 Cryocooler In A Magnetic Field

The Alpha Magnetic Spectrometer-02 (AMS-02) is an experiment that will be flown as an attached payload on the International Space Station to detect dark matter and antimatter. It uses large superconducting magnets cooled with superfluid helium to bend the path of cosmic particles through a series of detectors, which then measure the mass, speed, charge, and direction of the particles. Four Sunpower M87N Stirling-cycle cryocoolers are used to extend the mission life by cooling the outer vapor-cooled shield of the dewar. The main magnet coils are separated by a distance of approximately 1 m and the coolers are located approximately 1.5 m from the center line of the magnet, where the field is as high as 925 gauss perpendicular to the cryocooler axis and 400 gauss along the cryocooler axis. Interactions between the applied magnetic field and the linear motor may result in additional forces and torques on the compressor piston. Motion of the compressor arid displacer pistons through the magnetic field spatial gradients will generate eddy currents. Additional eddy currents are created during magnet charge, discharge, and quench by the time-varying magnetic field. The results of tests to determine the magnitude of the forces, torques, and heating effects, as well as the need for additional magnetic shielding, are presented.

Breon, S. R.↗

Metabolic effects of artificial environments

Effects of diluent gases on the metabolism of animals breathing nitrogen-oxygen, argon-oxygen, and helium-oxygen mixtures were studied. Results show that helium actually affected the mean free path of oxygen across the alveoli and increased metabolic rate. It is speculated that it might be necessary to keep an astronaut in a depressed metabolic state during prolonged space flight by using an argon-oxygen or a xenon-nitrogen mixture for breathing. Replacement of the depressant gases during periods requiring critical spacecraft maneuvers by neon-oxygen mixtures would insure maximal performance.

Jordan, J. P.↗

Heat Switches Providing Low-Activation Power and Quick-Switching Time for Use in Adiabatic Demagnetization Refrigerators

An adiabatic demagnetization refrigerator (ADR) is a solid-state cooler capable of achieving sub-Kelvin temperatures. It neither requires moving parts nor a density gradient in a working fluid making it ideal for use in space-based instruments. The flow of energy through the cooler is controlled by heat switches that allow heat transfer when on and isolate portions of the cooler when off. One type of switch uses helium gas as the switching medium. In the off state the gas is adsorbed in a getter thus breaking the thermal path through the switch. To activate the switch, the getter is heated to release helium into the switch body allowing it to complete the thermal path. A getter that has a small heat capacity and low thermal conductance to the body of the switch requires low-activation power. The cooler benefits from this in two ways: shorter recycle times and higher efficiency. We describe such a design here.

Kimball, Mark O.↗

Heat Switches Providing Low-Activation Power and Quick-Switching Time for Use in Cryogenic Multi-Stage Refrigerators

An adiabatic demagnetization refrigerator (ADR) is a solid-state cooler capable of achieving sub-Kelvin temperatures. It neither requires moving parts nor a density gradient in a working fluid making it ideal for use in space-based instruments. The flow of energy through the cooler is controlled by heat switches that allow heat transfer when on and isolate portions of the cooler when off. One type of switch uses helium gas as the switching medium. In the off state the gas is adsorbed in a getter thus breaking the thermal path through the switch. To activate the switch, the getter is heated to release helium into the switch body allowing it to complete the thermal path. A getter that has a small heat capacity and low thermal conductance to the body of the switch requires low-activation power. The cooler benefits from this in two ways: shorter recycle times and higher efficiency. We describe such a design here.

Kimball, Mark O.↗

Theoretical analysis of low-energy proton and helium anisotropies in the outer heliosphere

Expressions for streaming components are considered along with aspects of azimuthal anisotropy, taking into account a calculation of mean free paths and a comparison with corotation conditions. Questions of polar anisotropy are also taken into account. It is found that the azimuthal anisotropy of 30 - 56 MeV protons near the ecliptic plane at 12 AU in 1977 was consistent with corotation, or slightly faster. This implies that the mean free path is approximately 16 AU. The azimuthal anisotropy of the anomalous 10-21 and 30 - 56 MeV/nucleon helium at the same time and place was an order of magnitude less than the corotation value. This implies a mean free path of approximately 5 AU.

Forman, M. A.↗

The spectral properties of uranium hexafluoride and its thermal decomposition products

This investigation was initiated to provide basic spectral data for gases of interest to the plasma core reactor concept. The attenuation of vacuum ultraviolet (VUV) radiation by helium at pressures up to 20 atm over path lengths of about 61 cm and in the approximate wavelength range between 80 and 300 nm was studied. Measurements were also conducted to provide basic VUV data with respect to UF6 and UF6/argon mixtures in the wavelength range between 80 and 120 nm. Finally, an investigation was initiated to provide basic spectral emission and absorption data for UF6 and possible thermal decomposition products of UF6 at elevated temperatures.

Krascella, N. L.↗

Coalescence of Liquid Drops

When two liquid drops come into contact, a neck forms between them and grows rapidly. We are interested in the very early stage of the coalescence process, which can be characterized by the time dependence of the radius of the neck. The functional dependence of the size of the neck on time depends on the properties of the liquid. Experimentally, we are investigating a liquid in Stokes flow regime where the viscosity provides the principal retarding force to the surface tension. Recently, it has been predicted that the neck radius should change as t ln|t| in this regime. Theoretically, we have studied the situation when the velocity at each point on the surface is proportional to the local curvature and directed normal to the surface. This is the case that should be applicable to superfluid helium at low temperature when the mean free path of the thermal excitations are comparable to the size of liquid drops. For this system, the radius of the neck is found to be proportional to t(sup 1/3). We are able to find a simple expression for the shape of the interface in the vicinity of the neck.

Yao, Wei-Jun↗

Structures of strong shocks in low-density helium and neon gases

Strong shocks are essential components in many high-energy-density environments such as inertial confinement fusion implosions. However, the experimental measurements of the spatial structures of such shocks are sparse. In this paper, the soft x-ray emission of a shock front in a helium gas mixture (90% helium, 10% neon) and a pure neon gas was spatially resolved using an imaging spectrometer. We observe that the shock width in the helium mixture gas is about twice as large as in the pure neon gas. Moreover, they exhibit different precursor layers, where electron temperature greatly exceeds ion temperature, extending for more than ~350 µm with the helium gas mixture but less than 30 µm in the pure neon. At the shock front, calculations show that the electrons are strongly collisional with mean-free path two orders of magnitude shorter than the characteristic length of the shock. However, the helium ions can reach a kinetic regime as a consequence of their mean-free path being comparable to the scale of the shock. A radiation-hydrodynamic simulation demonstrates the impact of thermal conduction on the formation of the precursors with charge state, Z, playing a major role in heat flow and the precursor formation in both the helium mixture and the pure neon gases. Particle-in-cell simulations are also performed to study the ion kinetic effects on the formation of the observed precursors. A group of fast-streaming ions is observed leading the shock only in the helium gas mixture. Additionally, both effects explain the longer precursor layer in the helium shock.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Krypton-81 dating of the deep Continental Intercalaire aquifer with implications for chlorine-36 dating

Deep groundwater samples from the Continental Intercalaire (CI) aquifer in the Northern Tunisian Sahara have been analyzed for noble gases 3 He, 4 He, Ne and 81 Kr, and for 14 C to better constrain the groundwater residence time of this large transboundary aquifer. Its significant radiogenic 4 He content and background-level 14 C both indicate water older than a few tens of thousands of years. Distinct helium concentrations and Ne/He ratios suggest different groundwater flow paths through the Tozeur and Kebili regions. 81 Kr is applied for the first time on the CI aquifer, providing more direct evidence for the presence of old groundwater with 81 Kr/Kr ratios at 63% – 15% of the atmospheric value, corresponding to residence times of 150 – 630 ka. These newly obtained 81 Kr ages enable a re-evaluation of the previously reported data from the Tozeur region in order to better constrain the input values of 36 Cl/Cl and Cl. The initial 36 Cl/Cl ratio is found to be 4 – 6 times larger than previously assumed, and the initial Cl concentration 6 – 15 times smaller. The results of 81 Kr dating and the recalibrated 36 Cl dating define an eastward age progression across > 500 km of flow path from the Algerian to Tunisian sections. Here, this study exemplifies the utility of 81 Kr not only as an independent and conservative chronometer, but also as a supplemental measurement to better calibrate the parameters required for other age tracers, including cosmogenic 36 Cl and radiogenic 4 He.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Seal Technology for Liquid Oxygen (LOX) Turbopumps

Two types of advanced seals for liquid oxygen (LOX) turbopumps were investigated. One was a spiral-groove face seal whose function is to seal high-pressure LOX at the impeller end of the turbopump. The other was a floating-ring, Rayleigh-step, helium buffered seal used to prevent LOX ingress to the turbine side of the unit. For each seal type, two sizes were investigated (50 and 20 mm). A turbine-driven test rig was designed and manufactured, and a test program was completed on the 50 mm floating-ring, Rayleigh-step, helium buffered seal. Significant results were: vaporization in the flow path could cause failure by overheating; therefore, the spiral-groove pumping portion of the seal that provides the fluid film must circulate fluid without disruption if vaporization occurs in the sealing dam. This is successfully accomplished by a pressure-balanced spiral-groove concept that is described. The spiral-groove configuration is affected by turbulence in the fluid film and pressure drops due to fluid inertia at sudden contractions. The net results of these effects are deep grooves, large operating films, and high power loss when compared against seals operating with laminar films. Turbulence and inertia are induced by the high-density and low-viscosity characteristics of LOX. The program clearly pointed out the need to consider system environmental factors such as thermal and centrifugal distortions and rotor vibrations in the seal design.

Shapiro, Wilbur↗

Characterization of gaseous helium jet dispersion to atmosphere

A major ground-based experiment to be performed for the Superfluid Helium On Orbit Transfer (SHOOT) program is the accidental loss of the vacuum guard of the super-insulated dewar. The design of the dewar vent-path requires adequate mass removal after a preset pressure is reached due to external heat transfer. The existing helium creates a turbulent buoyant jet, expanding in air with entrainment of the jet interface to the surrounding. Transient analysis is performed for axial and radial jet temperature prediction using the self-similarity assumption applied to mass, momentum, and the energy-balance equations of helium. The predicted jet temperature profiles with vertical and radial expansion up to 1.6 and 1.0 m, respectively, demonstrate the low temperature core established by gaseous helium. For all time steps, the axial and radial temperature predictions are observed to be within 8 and 20 percent, respectively.

Khan, H. J.↗