Search NASA⌕ Search

SEARCH · Search NASA

Results for “heterodyne”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Photothermal heterodyne imaging of micron-sized objects

Micron-sized dye-doped polymer beads were imaged using transmitted/reflected light microscopy and photothermal heterodyne imaging (PHI) measurements. The transmitted/reflected light images show distinct ring patterns that are attributed to diffraction effects and/or internal reflections within the beads. In the PHI experiments pump laser induced heating changes the refractive index and size of the bead, which causes changes in the diffraction pattern and internal reflections. This creates an analogous ring pattern in the PHI images. The ring pattern disappears in both the reflected light and PHI experiments when an incoherent light source is used as a probe. When the beads are imaged in an organic medium heat transfer changes the refractive index of the environment, and gives rise to a ring pattern external to the beads in the PHI images. This causes the beads to appear larger than their physical dimensions in PHI experiments. This external signal does not appear when the beads are imaged in air because the refractive index changes in air are very small.

Bhandari, Janak (ORCID:0000000188423259)↗

A prototype hybrid mode cavity for heterodyne axion detection

In the heterodyne approach to axion detection, axion dark matter induces transitions between two modes of a microwave cavity, resulting in a parametrically enhanced signal power. We describe the fabrication and characterization of a prototype normal conducting cavity specifically optimized for heterodyne detection. Corrugations on the cavity walls support linearly polarized hybrid modes which maximize the signal power while strongly suppressing noise. We demonstrate tuning mechanisms which allow one mode frequency to be scanned across a 4 MHz range, while suppressing cross-coupling noise by at least 80 dB. A future superconducting cavity with identical geometry to our prototype would have the potential to probe orders of magnitude beyond astrophysical bounds.

Li, Zenghai [SLAC]↗

Development of a wide bandwidth heterodyne dispersion interferometer for electron density measurement of atmospheric pressure plasmas

One of the challenges of electron density measurements of an atmospheric pressure plasma (APP) with a laser interferometer is the significant and unwanted phase shift caused by changes in the neutral gas density. These unwanted phase shifts can be mitigated and plasma density measured using an interferometer architecture called a dispersion interferometer (DI). A DI is composed of two nonlinear orientation patterned GaAs crystals for frequency doubling and measures the phase shift induced by a plasma in the interference signal between two second-harmonic beams. Measurement of plasma dynamics or a short plasma pulse in less than a millisecond is enabled with heterodyne detection in a DI using an acousto-optic cell with a frequency of 40 MHz. This heterodyne DI (HDI) is targeted to measure APPs in an electron density range of 10 20 –10 24 m −3 . Finally, the HDI achieves a line-integrated density resolution of 2 × 10 15 m −2 (a phase resolution of 0.005°) with a time constant of 1 μs using ensemble averaging techniques.

atmospheric pressure plasma↗

Heterogeneous Dynamics in Shear Thickening Colloids Revealed by Intrinsic Heterodyne Correlation Spectroscopy

Shear induced frictional networks have been proposed to be responsible for the emergence of discontinuous shear thickening (DST) in complex fluids. However, little experimental evidence exists to support this model directly. Here, in this study, using x-ray photon correlation spectroscopy (XPCS), we show the existence of an intrinsic heterodyne feature during shear cessation, which originates from the relative motion of mobile particles against an aggregated or jammed network induced by shear thickening. Upon removing the shear, the shear stress dissipates rather quickly in a two-step fashion, whereas the heterogeneous particle dynamics persist much longer with the relative velocity decaying slowly with time as 𝑡 −1 . More importantly, both continuous shear thickening (CST) and DST show similar heterodyne features, indicating the intrinsic mechanisms causing shear thickening are similar in nature

Complex fluid↗

Spatial heterodyne spectroscopy for fast local magnetic field measurements of magnetized fusion plasmas

A novel spectroscopy diagnostic for measuring internal magnetic fields in high temperature magnetized plasmas has been developed. It involves spectrally resolving the Balmer- α (656 nm) neutral beam radiation split by the motional Stark effect with a spatial heterodyne spectrometer (SHS). The unique combination of high optical throughput (3.7 mm 2 sr) and spectral resolution (δλ ~ 0.1 nm) allows these measurements to be made with time resolution $\ll$1 ms. The high throughput is effectively utilized by incorporating a novel geometric Doppler broadening compensation technique in the spectrometer. The technique significantly reduces the spectral resolution penalty inherent to using large area, high-throughput optics while still collecting the large photon flux provided by such optics. In this work, fluxes of order 10 10 s –1 support the measurement of deviations of <5 mT (Δ λ Stark ~ 10 –4 nm) in the local magnetic field with 50 µs time resolution. Example high time resolution measurements of the pedestal magnetic field throughout the ELM cycle of a DIII-D tokamak plasma are presented. Local magnetic field measurements give access to the dynamics of the edge current density, which is essential to understanding stability limits, edge localized mode generation and suppression, and predicting performance of H-mode tokamaks.

47 OTHER INSTRUMENTATION↗

Hyperspectral and Nanosecond Temporal Resolution Widefield Infrared Photothermal Heterodyne Imaging

Label-free, bond-selective imaging offers new opportunities for fundamental and applied studies in chemistry, biology, and materials science. Preventing its broader application to investigating spectrally congested specimens are issues related to low sensitivity as well as low spatial and temporal resolution. Here, we demonstrate a widefield, mid-infrared (MIR) photothermal imaging technique, called widefield Infrared Photothermal Heterodyne imaging (wIR-PHI), that massively parallelizes acquisition of MIR absorption data through use of a high-speed complementary metal-oxide-semiconductor camera. wIR-PHI possesses notable features that include: spatial resolution significantly below the MIR diffraction limit, hyperspectral imaging capabilities, high sensitivity, and ~100 ns temporal resolution. Here, the first two features are highlighted by hyperspectral imaging of proximally close poly(methyl methacrylate) (PMMA) and polystyrene (PS) nanoparticles where clear, bond-specific imaging of nanoparticles, separated by less than the MIR diffraction limit, is demonstrated. Sensitivity is highlighted by imaging individual PMMA and PS nanoparticles with radii between r = 97-556 nm. This leads to a current, peak absorption cross-section limit-of-detection of σ abs = 1.9× 10 –16 cm 2 . wIR-PHI's 100 ns temporal resolution is simultaneously demonstrated by observing the decay of photothermal contrast on individual nanoparticles on a ~200-6000 ns timescale. In whole, wIR-PHI’s dramatic increase in acquisition speed opens opportunities for future MIR kinetic imaging and spectroscopic studies of important chemical, biological, and material processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implementation of heterodyne detection of radio frequency waves using phase contrast imaging

An upgrade to the DIII–D phase contrast imaging (PCI) diagnostic for detection of radio frequency waves has been implemented using low-noise optical heterodyning. Electro-optical modulation allows detection of waves with frequencies up to 500 MHz with wide flexibility restricted only by the driver electronics, with continuous adjustability up to 100 MHz and fixed frequency drivers needed for higher frequencies. The PCI diagnostic images the line-integrated plasma density fluctuations and provides absolutely calibrated measurements with good wavenumber resolution.

Rost, J. C. [Massachusetts Institute of Technology↗

Continuous automatic polarization channel stabilization from heterodyne detection of coexisting dim reference signals

Quantum networking continues to encode information in polarization states due to ease and precision. The variable environmental polarization transformations induced by deployed fiber need correction for deployed quantum networking. Here, we present a method for automatic polarization compensation (APC) and demonstrate its performance on a metropolitan quantum network. Designing an APC involves many design decisions as indicated by the diversity of previous solutions in the literature. Our design leverages heterodyne detection of wavelength-multiplexed dim classical references for continuous high-bandwidth polarization measurements used by newly developed multi-axis (non-)linear control algorithm(s) for complete polarization channel stabilization with no downtime. This enables continuous relatively high-bandwidth correction without significant added noise from classical reference signals. We demonstrate the performance of our APC using a variety of classical and quantum characterizations. Finally, we use C-band and L-band APC versions to demonstrate continuous high-fidelity entanglement distribution on a metropolitan quantum network with an average relative fidelity of 0.94 ± 0.03 for over 30 hrs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bayesian homodyne and heterodyne tomography: erratum

We correct typographical errors in Eq. (15) in [ Opt. Express 30 , 15184 ( 2022 ) 10.1364/OE.456597 ]. These errors were not present in the actual formulas used to calculate the results of the paper, so all results remain unaffected.

Chapman, Joseph C. (ORCID:0000000233460914)↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

BCARS Simulated Phantom Dataset for Evaluation of Processing Pipelines

Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy is a powerful label-free biological imaging technique, but the raw signal requires careful processing. The vibrationally resonant (Raman) fingerprint signal is usually small compared with instrumental noise sources and the nonresonant background (NRB) inherent in the BCARS signal. Fortunately, the NRB exhibits a systematic phase relationship with the coherent Raman response, acting as a heterodyne amplifier for the weak fingerprint signal. Due to this heterodyne effect, the Raman response can be recovered quantitatively and invariantly across different instruments, provided the NRB shape is known. Even with heterodyne amplification, the amplitudes of fingerprint signal components are often comparable to system noise. Singular value decomposition (SVD), which utilizes spatial information, is often employed for additional noise filtering. Consequently, finding optimal processing parameters to properly distinguish the NRB and Raman responses and suppress noise in the complex BCARS signal requires a reference system that realistically represents the spectral and spatial properties of BCARS signals obtained from biological samples. We present a digital tissue phantom that meets these criteria as a tool for testing candidate signal processing pipelines. The digital phantom is generated with simulated hyperspectral Raman images having system-specific noise and background characteristics. Here, we analyze phantom datasets with differing background and signal-to-noise conditions to evaluate their impact on the performance of multiple signal processing pipelines. Specifically, we investigate the application of a Butterworth filter-based routine to directly estimate the NRB from the BCARS signal. Additionally, we evaluate a Lorentzian wavelet transform as an alternative to the Hilbert transform for extracting the Raman spectrum from the BCARS signal. While we demonstrate this phantom for BCARS, it can be used for any spectroscopic Raman imaging approach.

Dixon, Jessica Z. [Georgia Institute of Technology↗

Determining the complex second-order optical susceptibility in macroscale van der Waals heterobilayers

In this work, we report on the experimental characterization of the second-order susceptibility in MoSe 2 /WS 2 heterobilayers, including their hidden complex phases. To this end, we developed a heterodyne-detection scheme for second-harmonic generation and applied it to macroscale heterobilayer samples prepared using the gold-tape exfoliation method. The heterodyne scheme enabled us to distinguish the relative orientation of the crystal domains, and furthermore, it allowed us to characterize the complex phases of the susceptibility relative to a reference quartz sample. By comparing the results from the monolayer regions and the heterobilayer region over several hundred microns of the sample area, we determined that the contribution of interlayer effects to second-harmonic generation is within the experimental uncertainty arising from the sample inhomogeneity. The results here provide fundamental quantitative information necessary for the precise design of nanophotonic systems based on stacking engineering.

2D materials↗

Title Coherent X-ray Studies of Surface Growth and Patterning Processes

X-ray Photon Correlation Spectroscopy (XPCS) is being developed as a tool to study nanoscale dynamics of fluctuations during thin film growth and surface patterning. XPCS examines the evolution of the X-ray scattering speckle pattern in reciprocal space to reveal dynamics information not accessible through any other means. Unlike low-coherence conventional X-ray scattering, which incoherently averages over different regions of a sample, coherent X-ray scattering is sensitive to the detailed structure of a given sample at that moment in time. In thin film growth processes, heterodyning, which occurs due to coherent mixing of two scattered signals, can be used to investigate the relationship between surface growth velocity and defect propagation. And, for polycrystalline thin film growth, the spatial coherence of the X-ray beam can substitute for the missing spatial coherence of the growth process to track layered growth in detail, even in a growth regime in which there are no conventional growth oscillations of the X-ray intensity. This has opened the door for detailed dynamics studies of individual atomic layers during real-world growth and patterning, not just in perfect single-crystal growth cases, which greatly expands the applicability of in-situ X-ray scattering methods. Step-flow dynamics in mounded polycrystalline growth has been studied separately for two thin film organic semiconductors deposited by thermal deposition in a vacuum environment, C60 and diindenoperylene (DIP). Highly oriented polycrystalline thin films are readily obtained in both systems, where mounds are composed of crystalline monolayer-height steps and terraces in a so-called wedding cake morphology. The formation of mounds is understood to be due to significant Ehrlich-Schwoebel step edge barriers that inhibit molecules from hopping down from one layer to the one below. The mounds exhibit local step flow, which can be monitored using coherent X-ray scattering. This is made possible due to heterodyning between scattering from the average mounds and the moving steps, which becomes visible in XPCS analysis. The effect of desorption, i.e. re-evaporation of deposited molecules is found to be important for understanding these processes. The impact of this work is to enable testing of models of step dynamics, the shape of mounds, and merging of mounds to form continuous thin films. Highly ordered polycrystalline thin films deposited on inexpensive substrates have applications in thin film solar cells and other organic electronic devices. In a separate set of experiments, speckle analysis during self-organized ion beam nanopatterning reveals memory stretching back to the beginning of patterning in the early stages and enables measurement of the velocity of self-organized patterns across surfaces providing the possibility of stringent new tests of the theory of pattern formation and motion.

36 MATERIALS SCIENCE↗

Laboratory tests of CO2 laser collective Thomson scattering for measurements of ion temperature in the divertor

Collective Thomson scattering (CTS) is a diagnostic method that measures the ion velocity distribution of a plasma. CO2 laser CTS measurements are challenging because of the inherently small Doppler broadening and scattering signals that are difficult to detect. We implemented a heterodyne detection scheme to measure spectrum changes of less than a GHz. To maximize the collected light at small scattering angles, we designed a unique light collection approach consisting of a customized conical-shaped (axicon) lens with a hole in the center. The axicon lens is used to collect the scattered light emitted within an annular cross-section from the scattering volume while the probe beam is passed through the hole at the center of the lens. The performance of the heterodyne detection scheme and annular collection approach was demonstrated using a Transverse Excited Atmospheric pressure CO2 laser with a pulse energy of 160 mJ at λ = 10.59 µm.

Instruments & Instrumentation↗

Tracing Long-Lived Atomic Coherences Generated via Molecular Conical Intersections

Accessing coherences is key to fully understand and control ultrafast dynamics of complex quantum systems like molecules. Most photochemical processes are mediated by conical intersections, which generate coherences between electronic states in molecules. We show with accurate calculations performed on gas-phase methyl iodide that electronic coherences of spin-orbit-split states persist in atomic iodine after dissociation. Our simulation predicts a maximum magnitude of vibronic coherence in the molecular regime of 0.75% of the initially photoexcited state population. Upon dissociation, one-third of this coherence magnitude is transferred to a long-lived atomic coherence where vibrational decoherence can no longer occur. To trace these dynamics, we propose a tabletop experimental approach—heterodyned attosecond four-wave-mixing spectroscopy. This technique can temporally resolve small electronic coherence magnitudes and reconstruct the full complex coherence function via phase cycling. Hence, heterodyned attosecond four-wave-mixing spectroscopy leads the way to a complete understanding and optimal control of spin-orbit-coupled electronic states in photochemistry.

Chemical Physics↗

Spectrograph stabilization using a single-delay interferometer on the Hale Telescope

We describe a technique for spectrograph stabilization useful when conventional mitigation techniques of vacuum tanks, thermal insulation, and laser frequency comb may be impractical, expensive, heavy, or bulky. This includes spectrographs on airborne platforms or mounted on telescopes where they suffer a changing gravity vector or other drifts. Placing a fixed-delay interferometer in series with a spectrograph forms an externally dispersed interferometer (EDI). This produces a uniform sinusoidal comb multiplying input spectrum, creating (through heterodyning) beats (moiré patterns). In Fourier space for low frequencies up to the comb frequency, the moiré generated signal counter-rotates to ordinary spectra under an unknown disperser wavenumber drift Δx. This generates a large negative feedback signal useful in a conceptual control loop, to converge rapidly to a stable spectrum and yield Δx. A modified EDI data analysis algorithm (“crossfading”) combines frequency-weighted moiré with conventional spectrum to cancel net output spectrum reaction to Δx. Needing only a single-delay, this is a practical improvement over prior crossfading analyses requiring multiple delays. We test crossfading on ThAr data near 4850 cm−1 taken on Hale telescope in an earlier project. In a single pass, we reduce drift 20 times. Using seven iterations, we reduce 0.5 cm−1 (31 km/s Doppler equivalent) drift to 4×10−7 cm−1 (2.5 cm/s). The interferometer delay can wander, because linearity of phase versus wavenumber interpolates science features between bracketing calibrating spectral references. Second, mathematically reversing the heterodyning effect doubles effective spectral resolution without changing disperser slit.

Erskine, David J [Lawrence Livermore National Labo↗