At least 19 records

Heterodyne Receiver for Origins

The Heterodyne Receiver for Origins (HERO) is the first detailed study of a heterodyne focal plane array receiver for space applications. HERO gives the Origins Space Telescope the capability to observe at very high spectral resolution (R ¼ 107) over an unprecedentedly large far-infrared (FIR) wavelengths range (111 to 617 μm) with high sensitivity, with simultaneous dual polarization and dual-frequency band operation. The design is based on prior successful heterodyne receivers, such as Heterodyne Instrument for the Far-Infrared /Herschel, but surpasses it by one to two orders of magnitude by exploiting the latest technological developments. Innovative components are used to keep the required satellite resources low and thus allowing for the first time a convincing design of a large format heterodyne array receiver for space. HERO on Origins is a unique tool to explore the FIR universe and extends the enormous potential of submillimeter astronomical spectroscopy into new areas of astronomical research.

Martina C Wiedner↗

An All-Solid-State, Room-Temperature, Heterodyne Receiver for Atmospheric Spectroscopy at 1.2 THz

Heterodyne receivers at submillimeter wavelengths have played a major role in astrophysics as well as Earth and planetary remote sensing. All-solid-state heterodyne receivers using both MMIC (monolithic microwave integrated circuit) Schottky-diode-based LO (local oscillator) sources and mixers are uniquely suited for long-term planetary missions or Earth climate monitoring missions as they can operate for decades without the need for any active cryogenic cooling. However, the main concern in using Schottky-diode-based mixers at frequencies beyond 1 THz has been the lack of enough LO power to drive the devices because 1 to 3 mW are required to properly pump Schottky diode mixers. Recent progress in HEMT- (high-electron-mobility- transistor) based power amplifier technology, with output power levels in excess of 1 W recently demonstrated at W-band, as well as advances in MMIC Schottky diode circuit technology, have led to measured output powers up to 1.4 mW at 0.9 THz. Here the first room-temperature tunable, all-planar, Schottky-diode-based receiver is reported that is operating at 1.2 THz over a wide (≈20%) bandwidth. The receiver front-end (see figure) consists of a Schottky-diode-based 540 to 640 GHz multiplied LO chain (featuring a cascade of W-band power amplifiers providing around 120 to 180 mW at W-band), a 200-GHz MMIC frequency doubler, and a 600-GHz MMIC frequency tripler, plus a biasable 1.2-THz MMIC sub-harmonic Schottky-diode mixer. The LO chain has been designed, fabricated, and tested at JPL and provides around 1 to 1.5 mW at 540 o 640 GHz. The sub-harmonic mixer consists of two Schottky diodes on a thin GaAs membrane in an anti-parallel configuration. An integrated metal insulator metal (MIM) capacitor has been included on-chip to allow dc bias for the Schottky diodes. A bias voltage of around 0.5 V/diode is necessary to reduce the LO power required down to the 1 to 1.5 mW available from the LO chain. The epilayer thickness and doping profiles have been specifically optimized to maximize the mixer performance beyond 1 THz. The measured DSB noise temperatures and conversion losses of the receiver are 2,000 to 3,500 K and 12 to 14 dB, respectively, at 120 K, and 4,000 to 6,000 K and 13 to 15 dB, respectively, at 300 K. These results establish the state-of-the-art for all-solid-state, all-planar heterodyne receivers at 1.2 THz operating at either room temperature or using passive cooling only. Since no cryogenic cooling is needed, the receiver is eminently suited to atmospheric heterodyne spectroscopy of the outer planets and their moons.

Siles, Jose V.↗

Design considerations for optical heterodyne receivers: A review

The current state of knowledge concerning optical heterodyne receivers is reviewed. Following a discussion of noise processes in the heterodyne receiver and the manner in which sensitivity is increased through time integration of the detected signal, an expression for the mean square signal current is derived by mixing a coherent local oscillator with a partially coherent, quasimonochromatic source. Then the manner in which the IF signal calculation can be transferred to any convenient plane in the optical front end of the receiver is demonstrated. Using these techniques, a relatively simple equation is obtained for the coherently detected signal from an extended incoherent source and applied to the heterodyne detection of an extended thermal source and to the backscatter lidar problem where the antenna patterns of both the transmitter beam and heterodyne receiver must be taken into account. Finally, the detection of a coherent source is considered and, in particular, a distant point source such as a star or laser transmitter in a long range heterodyne communications system is discussed.

Degnan, J. J.↗

Spatial frequency response of an optical heterodyne receiver

The analysis of a passive heterodyne receiver with respect to its imaging performance (transfer function) and its heterodyne efficiency shows departures from the results which are obtained in strictly coherent or incoherent imaging systems. The cascading property of modulation transfer function analysis must be carefully applied, since the coherent transfer function of the optical receiver and that due to the local oscillator-detector combination are not separable but are related by the convolution of their products. Application of these results to a spacelab-type optical heterodyne receiver shows that resolutions of the order of 1.5 to 2.0 km are possible for worst-case type orbital scenarios. In addition to an analysis of the derogatory effects of sampling (aliasing) a comparison of obscured-type receivers (e.g., Cassegrains) with unobscured receivers shows that both resolution and efficiency are severly degraded in an obscured-type receiver and, consequently, should not be used for passive heterodyne detection schemes.

Robinson, D. M.↗

Performance analysis of a noncoherently combined large aperture optical heterodyne receiver

The performance of a noncoherently combined, multiple-mirror heterodyne receiver is analyzed. It is shown that in the absence of atmospheric turbulence, the performance of the noncoherently combined receiver is inferior to that of a monolithic, diffraction-limited receiver with equivalent aperture area. However, when atmospheric turbulence is taken into consideration, the efficiency of a monolithic aperture heterodyne receiver is limited by the phase coherence length of the atmosphere and generally does not improve with increasing aperture size. In constrast, the performance of a noncoherently combined system improves with an increasing number of receivers. Consequently, given a fixed collecting area, the noncoherently combined system can offer superior performance. The performance of the noncoherently combined heterodyne receiver is studied by analyzing the combining loss of the receiver SNR. It is shown that, given the collecting area, the performance of the combined receiver is optimized when the diameter of each of the individual receivers is on the order of the phase coherence length gamma sub 0 of the atmospheric turbulence.

Chen, C.-C.↗

Performance analysis of a noncoherently combined large aperture optical heterodyne receiver

The performance of a noncoherently combined (NC) multiple-mirror heterodyne receiver is analyzed. With no atmospheric turbulence (AT), the performance of the NC receiver is shown to the inferior to that of a monolithic diffraction-limited receiver with equivalent aperture area. When AT is taken into consideration, however, the efficiency of a monolithic receiver is limited by the phase coherence length of the atmosphere, and generally does not improve with increasing aperture size. In contrast, the performance of an NC system improves with an increasing number of receivers. Consequently, given a fixed collecting area, the NC system can offer superior performance. The performance of the NC heterodyne receiver is studied by analyzing the combining loss of the receiver SNR. It is shown that, given a constant collecting area, the performance of the NC receiver is optimized when the diameter of each of the individual receivers is on the order of the phase coherence length of the AT.

Chen, Chien-Chung↗

Wideband heterodyne receiver for laser communication system

A heterodyne receiver for laser communication is described which includes a front end having a cooled photomixer contained in a hermetically sealed spaced quality housing designed for wide bandwidth transmission. The photomixer is coupled through a wideband preamplifier to the receiver back end which includes a frequency tracking network and demodulating equipment. The receiver is capable of tracking a Doppler frequency shift of 750 MHz, positive or negative, and has an instantaneous intermediate frequency information bandwidth of 400 MHz. The receiver system is also capable of operating over a wide temperature range and is designed to be suitable for use in outer space communication.

Flattau, T.↗

Analysis of Optimum Heterodyne Receivers for Coherent Lidar Applications

A full analysis of the combined effects of all the noise sources of optical heterodyne receiver and the interaction between the competing control parameters of the receiver detector and pre-amplifier will be presented. This analysis provides the mean for true optimization of the coherent lidar receiver. The significance of the optimization of heterodyne receiver is shown for 2-micron coherent lidar.

Amzajerdian, Farzin↗

30-micron heterodyne receiver

Advantages and constraints of remote measurements using heterodyne spectroscopy near 30 microns are discussed. The state of the art of wideband HgCdTe photomixers and PbSnSe diode-laser local oscillators being developed for FIR heterodyne receivers is described. The first compact 30-micron heterodyne radiometer was built, and initial results at 28-microns show about 2-percent mixer efficiency for a 500-MHz-bandwidth receiver. Factors limiting receiver performance are discussed, along with the projected sensitivity of new interdigitated-electrode HgCdTe photoconductor mixers being developed for operation up to 200 microns.

Kostiuk, Theodor↗

Submillimeter wave heterodyne receiver

In an embodiment, a submillimeter wave heterodyne receiver includes a finline ortho-mode transducer comprising thin tapered metallic fins deposited on a thin dielectric substrate to separate a vertically polarized electromagnetic mode from a horizontally polarized electromagnetic mode. Other embodiments are described and claimed.

Chattopadhyay, Goutam↗

Cryogenic 160-GHz MMIC Heterodyne Receiver Module

A cryogenic 160-GHz MMIC heterodyne receiver module has demonstrated a system noise temperature of 100 K or less at 166 GHz. This module builds upon work previously described in Development of a 150-GHz MMIC Module Prototype for Large-Scale CMB Radiation (NPO-47664), NASA Tech Briefs, Vol. 35, No. 8 (August 2011), p. 27. In the original module, the local oscillator signal was saturating the MMIC low-noise amplifiers (LNAs) with power. In order to suppress the local oscillator signal from reaching the MMIC LNAs, the W-band (75 110 GHz) signal had to be filtered out before reaching 140 170 GHz. A bandpass filter was developed to cover 120 170 GHz, using microstrip parallel-coupled lines to achieve the desired filter bandwidth, and ensure that the unwanted W-band local oscillator signal would be sufficiently suppressed. With the new bandpass filter, the entire receiver can work over the 140 180-GHz band, with a minimum system noise temperature of 460 K at 166 GHz. The module was tested cryogenically at 20 K ambient temperature, and it was found that the receiver had a noise temperature of 100 K over an 8-GHz bandwidth. The receiver module now includes a microstrip bandpass filter, which was designed to have a 3-dB bandwidth of approximately 120-170 GHz. The filter was fabricated on a 3-mil-thick alumina substrate. The filter design was based on a W-band filter design made at JPL and used in the QUIET (Q/U Imaging ExperimenT) radiometer modules. The W-band filter was scaled for a new center frequency of 150 GHz, and the microstrip segments were changed accordingly. Also, to decrease the bandwidth of the resulting scaled design, the center gaps between the microstrip lines were increased (by four micrometers in length) compared to the gaps near the edges. The use of the 150-GHz bandpass filter has enabled the receiver module to function well at room temperature. The system noise temperature was measured to be less than 600 K (at room temperature) from 154 to 168 GHz. Additionally, the use of a W-band isolator between the receiver module and the local oscillator source also improved the noise temperature substantially. This may be because the mixer was presented with a better impedance match with the use of the isolator. Cryogenic testing indicates a system noise temperature of 100 K or less at 166 GHz. Prior tests of the MMIC amplifiers alone have resulted in a system noise temperature of 65.70 K in the same frequency range (.160 GHz) when cooled to an ambient temperature of 20 K. While other detector systems may be slightly more sensitive (such as SIS mixers), they require more cooling (to 4 K ambient) and are not as easily scalable to build a large array, due to the need for large magnets and other equipment. When cooled to 20 K, this receiver module achieves approximately 100 K system noise temperature, which is slightly higher than single-amplifier module results obtained at JPL (65.70 K when an amplifier is corrected for back-end noise contributions). If this performance can be realized in practice, and a scalable array can be produced, the impact on cosmic microwave background experiments, astronomical and Earth spectroscopy, interferometry, and radio astronomy in general will be dramatic.

Samoska, Lorene A.↗

Spatial frequency response of an optical heterodyne receiver

The principles of transfer function analysis are applied to a passive optical heterodyne receiver to obtain the modulation transfer function (MTF). MTF calculations are performed based on an optical platform which is imaging vertically varying profiles at worst case shuttle orbit altitudes. An analysis of the derogatory effects of sampling (aliasing) and central obscurations on both resolution and heterodyne efficiency is given. It is found that the cascading property of MTF analysis must be carefully applied since the coherent transfer function of the optical receiver and that due to the local oscillator-detector combination are not separable but are related by the convolution of their products. Application of these results to the specific case of a space-lab type optical heterodyne receiver shows that resolutions of the order of 1.5-2.0 Km are possible for worst-case type orbital scenarios. Further, comparison of obscured-type receivers (e.g., Cassegrains) with unobscured receivers shows that both resolution and efficiency are severely degraded in an obscured-type receiver and consequently should not be used for a passive heterodyne detection scheme.

Fales, C. L.↗

Wideband infrared heterodyne receiver front-end

A 10.6 micron infrared heterodyne receiver front end was developed for use in a wideband CO2 laser communications link. The infrared receiver employs an 850 MHz response PV HgCdTe photomixer which is mounted in a space quality housing, a low-noise 5 to 1500 MHz IF preamplifier, and a remote control panel. The receiver was designed to handle + or - 750 MHz of Doppler shift while providing an instantaneous information bandwidth of 400 MHz. The measured receiver sensitivity NEP was 1.0 x 10 to the 19th power W/Hz for a photomixer temperature of T sub m = 77 K and an IF beat frequency of 20 MHz and degraded to 1.75 x 10 to the 19th power W/Hz for T sub m = 130 K.

Peyton, B. J.↗

Optically pumped submillimeter laser heterodyne receivers - Astrophysical observations and recent technical developments

NASA's prospective sub-mm-wave astrophysical missions encompass the Small Explorer Submillimeter Wave Astronomy Satellite, scheduled for launch in 1995, the Submillimeter Intermediate Mission, and the Large Deployable Reflector; until these are operational, sub-mm observations will be conducted at mountain sites and aboard aircraft platforms. Attention is presently given to the technical challenges faced by terahertz-range receiver developers, and it is noted that optically pumped sub-mm lasers furnish the only practical local oscillation source for heterodyne receivers in the 600-3000 GHz range. An account is given of ground-based and airborne astrophysical applications of heterodyne receivers.

Chin, Gordon↗

An Extremely Wide Bandwidth, Low-Noise SIS Heterodyne Receiver Design for Millimeter and Submillimeter Observations

Millimeter and submillimeter heterodyne receivers using state-of-the-art SIS detectors are capable of extremely large instantaneous bandwidths with noise temperatures within a few Kelvin of the quantum limit. We present the design for a broadband, sensitive, heterodyne spectrometer under development for the Caltech Submillimeter Observatory (CSO). The 180-300 GHz double-sideband design uses a single SIS device excited by a full bandwidth, fixed-tuned waveguide probe on a silicon substrate. The IF output frequency (limited by the MMIC low noise IF preamplifier) is 6-18 GHz, providing an instantaneous RF bandwidth of 24 GHz (double-sideband). The SIS mixer conversion loss should be no more than 1-2 dB with mixer noise temperatures across the band within 10 K of the quantum limit. The single-sideband receiver noise temperature goal is 70 K. The wide instantaneous bandwidth and low noise will result in an instrument capable of a variety of important astrophysical observations beyond the capabilities of current instruments. Lab testing of the receiver will begin in the summer of 2002, and the first use on the CSO should occur in the spring of 2003.

Sumner, Matthew↗