Techniques for High Contrast Imaging in Multi-Star Systems II: Multi-Star Wavefront Control

Direct imaging of exoplanets represents a challenge for astronomical instrumentation due to the high-contrast ratio and small angular separation between the host star and the faint planet. Multi-star systems pose additional challenges for coronagraphic instruments because of the diffraction and aberration leakage introduced by the additional stars, and as a result are not planned to be on direct imaging target lists. Multi-star wavefront control (MSWC) is a technique that uses a coronagraphic instrument's deformable mirror (DM) to create high-contrast regions in the focal plane in the presence of multiple stars. Our previous paper introduced the Super-Nyquist Wavefront Control (SNWC) technique that uses a diffraction grating to enable the DM to generate high-contrast regions beyond the nominal controllable region. These two techniques can be combined to generate high-contrast regions for multi-star systems at any angular separations. As a case study, a high-contrast wavefront control (WC) simulation that applies these techniques shows that the habitable region of the Alpha Centauri system can be imaged reaching 8 times 10(exp -9) mean contrast in 10 percent broadband light in one-sided dark holes from 1.6-5.5 lambda (wavelength) divided by D (distance).

Sirbu, D.↗

Full-wave and half-wave rectification in second-order motion perception

Microbalanced stimuli are dynamic displays which do not stimulate motion mechanisms that apply standard (Fourier-energy or autocorrelational) motion analysis directly to the visual signal. In order to extract motion information from microbalanced stimuli, Chubb and Sperling [(1988) Journal of the Optical Society of America, 5, 1986-2006] proposed that the human visual system performs a rectifying transformation on the visual signal prior to standard motion analysis. The current research employs two novel types of microbalanced stimuli: half-wave stimuli preserve motion information following half-wave rectification (with a threshold) but lose motion information following full-wave rectification; full-wave stimuli preserve motion information following full-wave rectification but lose motion information following half-wave rectification. Additionally, Fourier stimuli, ordinary square-wave gratings, were used to stimulate standard motion mechanisms. Psychometric functions (direction discrimination vs stimulus contrast) were obtained for each type of stimulus when presented alone, and when masked by each of the other stimuli (presented as moving masks and also as nonmoving, counterphase-flickering masks). RESULTS: given sufficient contrast, all three types of stimulus convey motion. However, only one-third of the population can perceive the motion of the half-wave stimulus. Observers are able to process the motion information contained in the Fourier stimulus slightly more efficiently than the information in the full-wave stimulus but are much less efficient in processing half-wave motion information. Moving masks are more effective than counterphase masks at hampering direction discrimination, indicating that some of the masking effect is interference between motion mechanisms, and some occurs at earlier stages. When either full-wave and Fourier or half-wave and Fourier gratings are presented simultaneously, there is a wide range of relative contrasts within which the motion directions of both gratings are easily determinable. Conversely, when half-wave and full-wave gratings are combined, the direction of only one of these gratings can be determined with high accuracy. CONCLUSIONS: the results indicate that three motion computations are carried out, any two in parallel: one standard ("first order") and two non-Fourier ("second-order") computations that employ full-wave and half-wave rectification.

Motion Perception/physiology↗

Modulation transfer function measurement technique for small-pixel detectors

A modulation transfer function (MTF) measurement technique suitable for large-format, small-pixel detector characterization has been investigated. A volume interference grating is used as a test image instead of the bar or sine wave target images normally used. This technique permits a high-contrast, large-area, sinusoidal intensity distribution to illuminate the device being tested, avoiding the need to deconvolve raw data with imaging system characteristics. A high-confidence MTF result at spatial frequencies near 200 cycles/mm is obtained. We present results at several visible light wavelengths with a 6.8-micron-pixel CCD. Pixel response functions are derived from the MTF results.

Marchywka, Mike↗

Rapid Assessment of Contrast Sensitivity with Mobile Touch-screens

The availability of low-cost high-quality touch-screen displays in modern mobile devices has created opportunities for new approaches to routine visual measurements. Here we describe a novel method in which subjects use a finger swipe to indicate the transition from visible to invisible on a grating which is swept in both contrast and frequency. Because a single image can be swiped in about a second, it is practical to use a series of images to zoom in on particular ranges of contrast or frequency, both to increase the accuracy of the measurements and to obtain an estimate of the reliability of the subject. Sensitivities to chromatic and spatio-temporal modulations are easily measured using the same method. We will demonstrate a prototype for Apple Computer's iPad-iPod-iPhone family of devices, implemented using an open-source scripting environment known as QuIP (QUick Image Processing,

mobile devices↗

15 cut-off 128x128 Quantum Well Infrared Photodetectors (QWIPS) Camera

We discuss the development and the performance of a very long wavelength (13.5 - 15 128x128 AlGaAs/GaAs multiquantum well infrared imaging system. Highly uniform, high-yield QWIP focal plane array was hybridized to a CMOS multiplexer operating in a direct injection mode. For efficient light coupling an integral random scattering reflector (Random Grating) was incorporated. Due to the high uniformity, excellent imagery, low noise as well as a noise equivalent temperature difference (NE T) of less than 30 mK were obtained when operating around 45 K. Therefore, high image contrast signal to noise ratio has been achieved.

128x128 Photodetectors↗

Spatial-frequency spectrum of patterns changes the visibility of spatial-phase differences

It is shown that spatial-frequency components over a 4-octave range affected the visibility of spatial-phase differences. Contrast thresholds were measured for discrimination between two (+45- and -45-deg) spatial phases of a sinusoidal test grating added to a background grating. The background could contain one or several sinusoidal components, all in 0-deg phase. Phase differences between the test and the background were visible at lower contrasts when test and background frequencies were harmonically related than when they were not, when test and background frequencies were within 1 octave than when they were farther apart, when the fundamental frequency of the background was low than when it was high, and for some discriminations more than for others, after practice. The visibility of phase differences was not affected by additional components in the background if the fundamental and difference frequencies of the background remained unchanged. Observers' reports of their strategies gave information about the types of attentive processing that were used to discriminate phase differences. Attentive processing facilitated phase discrimination for multifrequency gratings spanning a much wider range of spatial frequencies than would be possible by using only local preattentive processing. These results were consistent with the visibility of phase differences being processed by some combination of even- and odd-symmetric simple cells tuned to a wide range of different spatial frequencies.

Lawton, T. B.↗

Moire interferometry for deformation and strain studies

Recent advances in high sensitivity more interferometry are described. In-plane displacement fields are shown for very challenging problem areas: adhesive joints in tension and in bending, flexure of quasi-isotropic composite laminates, and fatigue cracks in aluminum. Reference gratings with 2400 lines/mm (60,690 l/in) were used, providing a sensitivity of 0.417 micron/fringe order (16.4 microinch./fringe order). Excellent fringe contrast was obtained in all cases, even for gradients of 64 fringes/mm (1600 fringes/in.). A four-beam optical system to produce two orthogonal virtual reference gratings was employed. The question of unknown relative displacements in two-body problems was answered by use of a soft bridge between the bodies to provide a continous path for the fringe count.

Post, D.↗

Comparison of commercially available polarizing gratings for mid-infrared studies

We present the results of lab comparison tests of performance for several commercially available grating polarizers sold for use at mid-infrared wavelengths. The tests were done using a polarized laser diode source (9.2 μm) and photoconductive HgCdTe single pixel detector. We describe some basic equations governing quantification of polarization performance, our instrumental test setup and our results. There is a great deal of difference in the contrast produced by polarizers from different companies. Availability of high-transmission, high-contrast polarizers for use at near and mid-infrared wavelengths will make it possible to routinely characterize polarization of astronomical sources, such as physical properties of dust grains and magnetic field lines around sources of interest.

Geis, J. M.↗

Analysis of AIS Data of the Recluse Oil Field, Recluse, Wyoming

Airborne Imaging Spectrometer (AIS) data were flown over the Recluse, Wyoming oil field on September 9, 1984. Processing software was developed at Earth Satellite Corporation (EarthSat) for interactive analysis of the AIS data. EarthSat's AIS processing capabilities include destriping, solar irradiance corrections, residual calculations, geometric resampling, equal energy normalization, interactive spectral classifications and a variety of compressive algorithms to reduce the data to 8-bit format with a minimum of information loss. The in-house photolab facilities of EarthSat can routinely produce high-quality color renditions of the enhanced AIS data. A total of 80 lithologic samples were collected under the AIS flight lines. Correlation (within the atmospheric windows) between the laboratory and the AIS spectra of sample sites was generally poor. Reasonable correlation was only possible in large, freshly plowed fields. Mixed pixels and contrast between the natural and sample's surfaces were believed responsible for the poor correlation. Finally, a drift of approximately three channels was observed in the diffraction grating position within the 1.8 to 2.1 micron quadrant.

Dykstra, J. D.↗

Multi-Star Wavefront Control at the Occulting Mask Coronagraph Testbed: Monochromatic Laboratory Demonstration for the Roman Coronagraph Instrument

The Astro2020 decadal survey recommended a direct imaging flagship mission with a goal for mission yield of 25 or more potentially habitable exoplanets. A majority of Sun-like stars have a stellar companion that can introduce additional noise into the field of view of any high-contrast imaging instrument and enabling exoplanet discovery around binary stars represents a path to increased coronagraphic instrument efficiency. This includes both of the Alpha Centauri A and B stars which would represent the top science target for direct imaging if companion leakage can be suppressed. Multi-Star Wavefront Control (MSWC) is a technique that removes stellar leakage from both stellar components, enabling direct imaging of exoplanets in many binary star systems. We present the latest testbed results obtained with MSWC as part of the technology development effort focusing on demonstrations conducted on the Occulting Mask Coronagraph (OMC) testbed at JPL. OMC has a layout similar to the Roman Space Telescope coronagraph instrument (CGI) and is outfitted with a MSWC mask with the same design as the contributed mask for the Roman CGI. Our testbed results represent the first demonstrations of this technique using the recently installed full binary source for a geometry matching potential Alpha Centauri observations. Technical Review Abstract: The Astro2020 decadal survey recommended a direct imaging flagship mission with a goal for mission yield of 25 or more potentially habitable exoplanets. A majority of Sun-like stars have a stellar companion that can introduce additional noise into the field of view of any high-contrast imaging instrument and enabling exoplanet discovery around binary stars represents a path to increased coronagraphic instrument efficiency by increasing the available science target pool of bright nearby stars. This includes both of the Alpha Centauri A and B stars which would represent the top science target for direct imaging if companion leakage can be suppressed. Multi-Star Wavefront Control (MSWC) is a technique that removes stellar leakage from both stellar components, enabling direct imaging of exoplanets in many binary star systems . We present the latest testbed results obtained with MSWC as part of the technology development effort focusing on demonstrations conducted on the Occulting Mask Coronagraph (OMC) testbed at JPL during the completed first vacuum window and recent results from the ongoing second vacuum window. The MSWC mask consists of a shaped pupil mask similar to the one used for the Wide-Field of View mode but also includes a set of superimposed, regularly-spaced dots that serve as a diffraction grating. OMC has a layout similar to the Roman Space Telescope coronagraph instrument (CGI) and is configured with a binary imaging mode with a MSWC mask using same design as the contributed mask for the Roman CGI. Our testbed results represent the first demonstrations of this technique using the recently installed full binary source. We present results obtained in Super-Nyquist regime demonstrating suppression in the Super-Nyquist regime for the 3rd diffraction order reaching 8.7e-9 contrast with the Roman pupil. In addition, we present results obtained with the binary-star regime demonstrating 9.6e-8 contrast for a geometry matching potential Alpha Centauri observations in a monochromatic wavelength similar to Band 1. Planned demonstrations in the 2nd vacuum window will focus on Band 3d and Band 4 using the full MSWC mode for an Alpha Centauri geometry.

High-contrast imaging↗

Extended-Range Ultrarefractive 1D Photonic Crystal Prisms

A proposal has been made to exploit the special wavelength-dispersive characteristics of devices of the type described in One-Dimensional Photonic Crystal Superprisms (NPO-30232) NASA Tech Briefs, Vol. 29, No. 4 (April 2005), page 10a. A photonic crystal is an optical component that has a periodic structure comprising two dielectric materials with high dielectric contrast (e.g., a semiconductor and air), with geometrical feature sizes comparable to or smaller than light wavelengths of interest. Experimental superprisms have been realized as photonic crystals having three-dimensional (3D) structures comprising regions of amorphous Si alternating with regions of SiO2, fabricated in a complex process that included sputtering. A photonic crystal of the type to be exploited according to the present proposal is said to be one-dimensional (1D) because its contrasting dielectric materials would be stacked in parallel planar layers; in other words, there would be spatial periodicity in one dimension only. The processes of designing and fabricating 1D photonic crystal superprisms would be simpler and, hence, would cost less than do those for 3D photonic crystal superprisms. As in 3D structures, 1D photonic crystals may be used in applications such as wavelength-division multiplexing. In the extended-range configuration, it is also suitable for spectrometry applications. As an engineered structure or artificially engineered material, a photonic crystal can exhibit optical properties not commonly found in natural substances. Prior research had revealed several classes of photonic crystal structures for which the propagation of electromagnetic radiation is forbidden in certain frequency ranges, denoted photonic bandgaps. It had also been found that in narrow frequency bands just outside the photonic bandgaps, the angular wavelength dispersion of electromagnetic waves propagating in photonic crystal superprisms is much stronger than is the angular wavelength dispersion obtained by use of conventional prisms and diffraction gratings and is highly nonlinear.

Ting, David Z.↗

Enabling High-Contrast Imaging of Binary Stars With the Roman Space Telescope Coronagraph Instrument

A large fraction of Sun-like stars is contained in binary systems, in fact within 10 pc there are 67 FGK stars, out of which 42 belong to a multi-star system, and 28 have companion leak that is greater than 1e-9 contrast, assuming typical Hubble-quality space optics. Currently, those binary stars are not included in the Roman Space Telescope Coronagraph Instrument target list, but they could be observed if high-contrast imaging around binary star systems using Roman was possible. The Multi-Star Wavefront Control (MSWC) algorithm can be used to suppress companion star leakage. If the targets have angular separations larger than the Nyquist controllable region of the Deformable Mirror, MSWC must operate in its Super-Nyquist (SN) mode. This mode requires a target star replica within the SN region in order to provide the ability to null speckles at SN angular separations. For the case of Roman, more than half of the targets that can be observed using MSWC, including Alpha Centauri, have angular separations larger than the Nyquist controllable region of the 48x48 actuator Deformable Mirror (DM) to be used. In this paper, we describe how super-Nyquist MSWC can be implemented in Roman CGI adding a mild grating on a replica of the Wide-field Shaped Pupil mask, which would use a spare space in the Shaped Pupil Active Mechanism. We present the feasibility analysis, simulation results, and discuss the latest results on MSWC experiment from three different laboratories at NASA Ames, the Jet Propulsion Laboratory, and the Subaru telescope.

Prada, Camilo Mejia↗

Coastal Research Imaging Spectrometer

The Coastal Research Imaging Spectrometer (CRIS) is an airborne remote sensing system designed specifically for research on the physical, chemical, and biological characteristics of coastal waters. The CRIS includes a visible-light hyperspectral imaging subsystem for measuring the color of water, which contains information on the biota, sediment, and nutrient contents of the water. The CRIS also includes an infrared imaging subsystem, which provides information on the temperature of the water. The combination of measurements enables investigation of biological effects of both natural and artificial flows of water from land into the ocean, including diffuse and point-source flows that may contain biological and/or chemical pollutants. Temperature is an important element of such measurements because temperature contrasts can often be used to distinguish among flows from different sources: for example, a sewage outflow could manifest itself in spectral images as a local high-temperature anomaly. Both the visible and infrared subsystems scan in pushbroom mode: that is, an aircraft carrying the system moves along a ground track, the system is aimed downward, and image data are acquired in across-track linear arrays of pixels. Both subsystems operate at a frame rate of 30 Hz. The infrared and visible-light optics are adjusted so that both subsystems are aimed at the same moving swath, which has across-track angular width of 15 . Data from the infrared and visible imaging subsystems are stored in the same file along with aircraft- position data acquired by a Global Positioning System receiver. The combination of the three sets of data is used to construct infrared and hyperspectral maps of scanned areas (see figure). The visible subsystem is based on a grating spectrograph and a rapid-readout charge-coupled-device camera. Images of the swatch are acquired in 256 spectral bands at wavelengths from 400 to 800 nm. The infrared subsystem, which is sensitive in a single wavelength band of 8 to 10 m, is based on a focal-plane array of HgCdTe photodetectors that are cooled to an operating temperature of 77 K by use of a closed-Stirling-cycle mechanical cooler. The nonuniformities of the HgCdTe photodetector array are small enough that the raw pixel data from the infrared subsystem can be used to recognize temperature differences on the order of 1 C. By use of a built-in blackbody calibration source that can be switched into the field of view, one can obtain bias and gain offset terms for individual pixels, making it possible to offset the effects of nonuniformities sufficiently to enable the measurement of temperature differences as small as 0.1 C.

Lucey, Paul G.↗

Comet C2012 S1 (ISON): Observations of the Dust Grains From SOFIA and of the Atomic Gas From NSO Dunn and Mcmath-Pierce Solar Telescopes

Comet C/2012 S1 (ISON) is unique in that it is a dynamically new comet derived from the Oort cloud reservoir of comets with a sun-grazing orbit. Infrared (IR) and visible wavelength observing campaigns were planned on NASA's Stratospheric Observatory For Infrared Astronomy (SOFIA) and on National Solar Observatory Dunn (DST) and McMath-Pierce Solar Telescopes, respectively. We highlight our SOFIA (+FORCAST) mid- to far-IR images and spectroscopy (approx. 5-35 microns) of the dust in the coma of ISON are to be obtained by the ISON-SOFIA Team during a flight window 2013 Oct 21-23 UT (r_h approx. = 1.18 AU). Dust characteristics, identified through the 10 micron silicate emission feature and its strength, as well as spectral features from cometary crystalline silicates (Forsterite) at 11.05-11.2 microns, and near 16, 19, 23.5, 27.5, and 33 microns are compared with other Oort cloud comets that span the range of small and/or highly porous grains (e.g., C/1995 O1 (Hale-Bopp) and C/2001 Q4 (NEAT) to large and/or compact grains (e.g., C/2007 N4 (Lulin) and C/2006 P1 (McNaught)). Measurement of the crystalline peaks in contrast to the broad 10 and 20 micron amorphous silicate features yields the cometary silicate crystalline mass fraction, which is a benchmark for radial transport in our protoplanetary disk. The central wavelength positions, relative intensities, and feature asymmetries for the crystalline peaks may constrain the shapes of the crystals. Only SOFIA can look for cometary organics in the 5-8 micron region. Spatially resolved measurements of atoms and simple molecules from when comet ISON is near the Sun (r_h< 0.4 AU, near Nov-20-Dec-03 UT) were proposed for by the ISON-DST Team. Comet ISON is the first comet since comet Ikeya-Seki (1965f) suitable for studying the alkalai metals Na and K and the atoms specifically attributed to dust grains including Mg, Si, Fe, as well as Ca. DST's Horizontal Grating Spectrometer (HGS) measures 4 settings: Na I, K, C2 to sample cometary organics (along with Mg I), and [OI] as a proxy for activity from water (along with Si I and Fe I). State-of-the-art instruments that will also be employed include IBIS, which is a Fabry-Perot spectral imaging system that concurrently measures lines of Na, K, Ca II, or Fe, and ROSA (CSUN/QUB), which is a rapid imager that simultaneously monitors Ca II or CN. From McMath-Pierce, the Solar-Stellar Spectrograph also will target ISON (320-900 nm, R approx. 21,000, r_h<0.3 AU). Assuming survival, the intent is to target ISON over r_h<0.4 AU, characteristic of prior Na detections.

Oort cloud comets↗

Multi-Star Wavefront Control at the Occulting Mask Coronagraph Testbed: Monochromatic Laboratory Demonstration for the Roman Coronagraph Instrument

The Astro2020 decadal survey recommended the Habitable Worlds Observatory (HWO), NASA’s direct imaging flagship mission, with a goal to achieve a statistically robust mission yield of 25 or more potentially habitable exoplanets. One way to achieve is to increase the instrument effectiveness by introducing additional bright, nearby targets. A majority of Sun-like stars have a stellar companion that can introduce additional noise into the field of view of any high-contrast imaging instrument and enabling exoplanet discovery around binary stars represents a path to increased corona graphic instrument efficiency by increasing the available science target pool of bright nearby stars. This includes both of the Alpha Centauri A and B stars which would represent the top science target for direct imaging if companion leakage could be suppressed. Multi-Star Wavefront Control(MSWC) is a technique that removes stellar leakage from both stellar components, enabling direct imaging of exoplanets in many binary star systems which can potentially increase corona graphic instrument effectivenessWe present the latest testbed results obtained with MSWC as part of the technology development effort focusing on demonstrations conducted on the Occulting Mask Coronagraph (OMC) testbed at JPL during thevacuum test window last winter, with an additional vacuum test planned for this fall. The MSWC mask consists of a shaped pupil mask similar to the one used for the Wide-Field of View mode, but also includes a set of superimposed, regularly-spaced dots that serve as a diffraction grating. OMC has a layout similar to the RomanSpace Telescope coronagraph instrument and configured with a binary imaging mode with a MSWC mask using same design as the contributed mask for the Roman coronagraph. Our testbed results represent the first demonstrations of this technique using the recently installed full binary source. We present results demonstrating suppression in the Super-Nyquist regime for the 3rd diffraction order reaching 8.7e-9 contrast with the Roman pupil. In addition, we present results obtained with a physical binary source and running MSWC in a binary star regime demonstrating 9.6e-8 contrast for a geometry matching potential Alpha Centauri observations in a515 nm monochromatic wavelength (similar but bluer than for Band 1) using the 5th diffraction order. Planned demonstrations in the upcoming vacuum window this fall will focus on Band 3d and Band 4 using the full MSWC mode for an Alpha Centauri geometry.

Roman Coronagraph Instrument↗

Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (4STAR) Instrument Improvements

The Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (4STAR) combines airborne sun tracking and sky scanning with grating spectroscopy to improve knowledge of atmospheric constituents and their links to air-pollution and climate. Hyper-spectral measurements of direct-beam solar irradiance provide retrievals of gas constituents, aerosol optical depth, and aerosol and thin cloud optical properties. Sky radiance measurements in the principal and almucantar planes enhance retrievals of aerosol absorption, aerosol type, and size mode distribution. Zenith radiance measurements are used to retrieve cloud properties and phase, which in turn are used to quantify the radiative transfer below cloud layers. These airborne measurements tighten the closure between satellite and ground-based measurements. In contrast to the Ames Airborne Tracking Sunphotometer (AATS-14) predecessor instrument, new technologies for each subsystem have been incorporated into 4STAR. In particular, 4STAR utilizes a modular sun-trackingsky-scanning optical head with fiber optic signal transmission to rack mounted spectrometers, permitting miniaturization of the external optical head, and spectrometerdetector configurations that may be tailored for specific scientific objectives. This paper discusses technical challenges relating to compact optical collector design, radiometric dynamic range and stability, and broad spectral coverage at high resolution. Test results benchmarking the performance of the instrument against the AATS-14 standard and emerging science requirements are presented.

Atmopheric Research (4STAR)↗

Multi-Star Wavefront Control for the Wide-Field Infrared Survey Telescope

The Wide-Field Infrared Survey Telescope (WFIRST) is planned to have a coronagraphic instrument (CGI) to enable high-contrast direct imaging of exoplanets around nearby stars. The majority of nearby FGK stars are located in multi-star systems, including the Alpha Centauri stars which may represent the best quality targets for the CGI on account of their proximity and brightness potentially allowing the direct imaging of rocky planets. However, a binary system exhibits additional leakage from the off-axis companion star that may be brighter than the target exoplanet. Multi-Star Wavefront Control (MSWC) is a wavefront-control technique that allows suppression of starlight of both stars in a binary system thus enabling direct imaging of circumstellar planets in binary star systems such as Alpha Centauri. We explore the capabilities of the WFIRST CGI instrument to directly image multi-star systems using MSWC. We consider several simulated scenarios using the WFIRST CGI's Shaped Pupil Coronagraph Disk Mask. First, we consider close binaries such as Mu Cassiopeia that require no modifications to the WFIRST CGI instrument and can be implemented as a purely algorithmic solution. Second, we consider wide binaries such as Alpha Centauri that require a diffraction grating to enable suppression of the off-axis starlight leakage at Super-Nyquist separations. We demonstrate via simulation dark holes in 10 percent broadband compatible with the WFIRST CGI.

Sirbu, Dan↗

Fiber-Optic Bragg Gratings and Optical Holography Compared as Vibration Detectors

The NASA Glenn Research Center is interested in determining structural damage in engine components during flight to evaluate the health of aerospace propulsion systems. On the ground, we can use holography to detect structural damage by examining the characteristic mode shapes and frequencies of vibrating objects. We are studying the feasibility of using embedded fiber Bragg gratings (FBGs) to accomplish this goal in a flight-worthy system, by using the minimal intrusion and high sensitivity afforded by fiber optics. We have recently compared holographically imaged modes of vibrating plates with the corresponding dynamic strains detected by embedded FBGs. We constructed an experimental setup for studying the responses of FBGs to dynamic excitations. One of the plates was made of a polymer matrix composite (PMC) with an FBG embedded in it, and the other one was made of copper with surface-mounted FBGs. The instrumented plates were mounted and vibrated, and time-averaged holography was used to measure their surface displacements. Simultaneously, the signals from the FBGs were detected and sent via fiber-optic cable to a quiet location about 20 m away for interrogation. The the test configuration used for the PMC plate is shown. Experimental results are also shown. The FBG was embedded in the middle of the PMC plates, roughly within the center circular fringe in each of the interferograms shown. Two resonant excitation frequencies were used: 706 and 3062 Hz. The plot in this paper shows a larger FBG signal at the higher frequency; this is because the plate bends more at higher order resonant modes, causing higher strain. This contrasts to the smaller displacements characteristic of higher frequencies, which are measured by holographic techniques.