Search NASA⌕ Search

SEARCH · Search NASA

Results for “high current densities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of a high current density, high temperature superconducting cable for pulsed magnets

Abstract A low AC loss Rare Earth Barium Copper Oxide (REBCO) cable, based on the VIPER cable technology has been developed by Commonwealth Fusion Systems for use in high field, REBCO based tokamaks. The new cable is composed of partitioned and transposed copper ‘petals’ shaped to fit together in a circular pattern with each petal containing a REBCO tape stack and insulated from each other to reduce AC losses. A stainless steel jacket adds mechanical robustness—also serving as a vessel for solder impregnation—while a tube runs through the middle for cooling purposes. Additionally, fiber optic sensors are placed under the tape stacks for quench detection. To qualify this design, a series of experiments were conducted as part of the SPARC tokamak Central Solenoid Model Coil program—to retire the risks associated with full scale, fast ramping, high flux HTS Central Solenoid (CS) and Poloidal Field (PF) coils for tokamak fusion power plants and net energy demonstrators. These risk study and risk reduction experiments include (1) AC loss measurement and model validation in the range of ~5 T/s, (2) an IxB electromagnetic loading of over 850 kN/m at the cable level and up to 300 kN/m at the stack level, (3) a transverse compression resilience of over 350 MPa, (4) manufacturability at tokamak relevant speeds and scales, (5) cable to cable joint performance, (6) fiber optic based quench detection speed, accuracy, and feasibility, and (7) overall winding pack integration and magnet assembly. The result is a cable technology, now referred to as PIT VIPER, with AC losses that measure fifteen times lower (at ~5 T/s) than its predecessor technology; a 2% or lower degradation of critical current (Ic) at high IxB electromagnetic loads; no detectable Ic degradation up to 570 MPa of transverse compression on the cable unit cell; end to end magnet manufacturing, consistently producing Ic values within 7% of the model prediction; cable to cable joint resistances at 20 K on the order of ~15 nΩ; and fast, functional quench detection capabilities that do not involve voltage taps. This cable technology will be tested comprehensively in a Central Solenoid Model Coil to prove its readiness for compact, high field tokamak operation.

Sanabria, Charlie (ORCID:0000000150175309)↗

Growth and characterization of high current density, high-speed InAs/AlSb resonant tunneling diodes

InAs/AlSb double-barrier resonant tunneling diodes with peak current densities up to 370,000 A/sq cm and high peak-to-valley current ratios of 3.2 at room temperature have been fabricated. The peak current density is well-explained by a stationary-state transport model with the two-band envelope function approximation. The valley current density predicted by this model is less than the experimental value by a factor that is typical of the discrepancy found in other double-barrier structures. It is concluded that threading dislocations are largely inactive in the resonant tunneling process.

Soderstrom, J. R.↗

Can High Current Density HTS Magnets be Quench Protected Using Methods Used to Protect High Current Density LTS Magnets?

In the 1970s the Lawrence Berkeley Laboratory (LBL) was testing high current density magnets where the EJ 2 limit was up to two orders of magnitude higher than the quench protection methods of the period would permit at the time. LBL was designing a high current density (J) thin solenoid with a large volume and stored energy (E). The accepted EJ 2 limit at the time was ~10 23 J A 2 m -4 . In order to exceed the EJ 2 limit by two orders of magnitude, one had to greatly increase the quench protection voltages (V) and magnet current (I). In 1977, LBL tested four quench protection methods on a 2-meter diameter high current density solenoid with a stored energy of 2 MJ. Three of these quench protection methods worked well, but the fourth didn't appear to work. These methods will be discussed as to whether they can be applied to HTS or MgB 2 high current density magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Current Density Durability of Pt/C and PtCo/C Catalysts at Similar Particle Sizes in PEMFCs

The durability of carbon supported PtCo-alloy based nanoparticle catalysts play a key role in the longevity of proton-exchange membrane fuel cells (PEMFC) in electric vehicle applications. To improve its durability, it is important to understand and mitigate the various factors that cause PtCo-based cathode catalyst layers (CCL) to lose performance over time. These factors include i) electrochemical surface area (ECSA) loss, ii) specific activity loss, iii) H + /O 2 -transport changes and iv) Co 2+ contamination effects. We use a catalyst-specific accelerated stress test (AST) voltage cycling protocol to compare the durability of Pt and PtCo catalysts at similar average nanoparticle size and distribution. Our studies indicate that while Pt and PtCo nanoparticle catalysts suffer from similar magnitudes of electrochemical surface area (ECSA) losses, PtCo catalyst shows a significantly larger cell voltage loss at high current densities upon durability testing. The distinctive factor causing the large cell voltage loss of PtCo catalyst appears to be the secondary effects of the leached Co 2+ cations that contaminate the electrode ionomer. A 1D performance model has been used to quantify the cell voltage losses arising from various factors causing degradation of the membrane electrode assembly (MEA).

08 HYDROGEN↗

Thin Cation-Exchange Layers Enable High-Current-Density Bipolar Membrane Electrolyzers via Improved Water Transport

With suitable water dissociation (WD) catalysts, bipolar membranes (BPMs) can efficiently dissociate water into H + and OH – at the junction between anion- and cation-exchange layers (AEL and CEL, respectively). First, however, water must be transported through the AEL or CEL and thus against the outward flow of hydrated H + and OH – . This is a challenge intrinsic to the BPM architecture and limits operation to current densities typically less than ~0.5 A·cm –2 . Here we explore how water transport affects durability and performance in reference alkaline and acidic membrane electrolyzers, and we use the insight gained to design BPMs with improved water transport. We demonstrate a thin-CEL BPM (2-μm Nafion CEL|~200 nm TiO 2 |~200 nm NiO + ionomer|50 μm Sustainion AEL) which maintains a pH difference of ~14 units between the anode and cathode for current densities of up to 3.4 A·cm –2 with a total water electrolysis voltage of ~4 V and an estimated WD overpotential of ~1.5 V. Finally, such high-current-density operation is crucial for key emerging BPM applications, including in water and carbon-dioxide electrolyzers and in (regenerative) fuel cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical properties of blue light-emitting diodes in the InGaN/GaN system at high current densities

The current-voltage and brightness-voltage characteristics and the electroluminescence spectra of blue InGaN/GaN-based light-emitting diodes are studied to clarify the cause of the decrease in the emission efficiency at high current densities and high temperatures. It is found that the linear increase in the emission intensity with increasing injection current changes into a sublinear increase, resulting in a decrease in efficiency as the observed photon energy shifts from the mobility edge. The emission intensity decreases with increasing temperature when the photon energy approaches the mobility edge; this results in the reduction in efficiency on overheating. With increasing temperature, the peak of the electroluminescence spectrum shifts to lower photon energies because of the narrowing of the band gap. The results are interpreted taking into account the fact that the density-of-states tails in InGaN are filled not only via trapping of free charge carriers, but also via tunneling transitions into the tail states. The decrease in the emission efficiency at high currents is attributed to the suppression of tunneling injection and the enhancement of losses via the nonradiative recombination channel 'under' the quantum well.

36 MATERIALS SCIENCE↗

Comparison between the magnetic and transport critical current densities in high critical current density melt-textured yttrium barium copper-oxide

Using a recently developed pulsed critical current density (Jc) measuring system, the Jc of the high-Jc melt-textured YBa2Cu3O(7-delta) (Y123) bulk samples has been determined. I-V curves with a voltage resolution of 0.5 microV were obtained, and transport Jc's along the a-b plane as high as 7.2 x 10 to the 4th A/sq cm were extracted. These results are comparable to the values obtained magnetically. On the other hand, transport Jc along the c axis were found to be two orders of magnitude smaller, even though the magnetic Jc along the c axis is only about five times smaller than Jc along the a-b plane. It is suggested that for the high-temperature superconducting materials which are highly anisotropic, caution should be taken when using the nontransport magnetic methods to determine Jc.

Gao, L.↗

Materials and Design Selection to Improve High Current Density Performance in PEMFC

Performance at high current density is dominated by transport losses from resistance to oxygen and proton transport. The materials selection and their properties can have a significant impact on the transport resistance. Here, in this study, the impact of catalyst carbon support microstructure and its properties impacting performance at high current density is studied in detail. Platinum-cobalt alloy catalysts supported on different carbon supports were analyzed for pore size distribution characteristics. Catalyst layer electrochemical diagnostics such as oxygen limiting current and H 2 /N 2 impedance tests were conducted to measure local oxygen transport resistance and bulk proton transport resistance. For the first time, the local-oxygen transport and the bulk-proton transport resistances in the catalyst layer are directly correlated to the micropore and macropore properties of the carbon support.

08 HYDROGEN↗

High Current Density, Long Life Cathodes for High Power RF Sources

This program was tasked with improving the quality and expanding applications for Controlled Porosity Reservoir (CPR) cathodes. Calabazas Creek Research, Inc. (CCR) initially developed CPR cathodes on a DOE-funded SBIR program to improve cathodes for magnetron injection guns. Subsequent funding was received from the Defense Advanced Research Projects Agency. The program developed design requirements for implementation of the technology into high current density cathodes for high frequency applications. During Phase I of this program, CCR was awarded the prestigious 2011 R&D100 award for this technology. Subsequently, the technology was presented at numerous technical conferences. A patent was issued for the technology in 2009. These cathodes are now marketed by Semicon Associates, Inc. in Lexington, KY. They are the world’s largest producer of cathodes for vacuum electron devices. During this program, CCR teamed with Semicon Associates, Inc. and Ron Witherspoon, Inc. to improve the fabrication processes and expand applications for the cathodes. Specific fabrications issues included the quality of the wire winding that provides the basic structure and the sintering to bond the wires into a robust, cohesive structure. The program also developed improved techniques for integrating the resulting material into cathodes for electron guns.

43 PARTICLE ACCELERATORS↗

High current density cathode for electrorefining in molten electrolyte

A high current density cathode for electrorefining in a molten electrolyte for the continuous production and collection of loose dendritic or powdery deposits. The high current density cathode eliminates the requirement for mechanical scraping and electrochemical stripping of the deposits from the cathode in an anode/cathode module. The high current density cathode comprises a perforated electrical insulated material coating such that the current density is up to 3 A/cm.sup.2.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Periodic Porous 3D Electrodes Mitigate Gas Bubble Traffic during Alkaline Water Electrolysis at High Current Densities

We report alkaline water electrolysis at high current densities is plagued by gas bubble generation and trapping in stochastic porous electrodes (e.g., Ni foams), which causes a significant reduction in the number of electrolyte accessible catalyst active sites. Here, 3D printed Ni (3DPNi) electrodes with highly controlled, periodic structures are reported that suppress gas bubble coalescence, jamming, and trapping and, hence, result in rapid bubble release. The 3DPNi electrodes decorated with carbon-doped NiO achieve a high current density of 1000 mA cm -2 in 1.0 m KOH electrolyte at hydrogen evolution reaction and oxygen evolution reaction overpotentials of 245 and 425 mV, respectively. This work demonstrates a new approach to the deterministic design of 3D electrodes to facilitate rapid bubble transport and release to enhance the total electrode catalytic activity at commercially relevant current densities.

08 HYDROGEN↗

A Hydrogen Iron Flow Battery with High Current Density and Long Cyclability Enabled Through Circular Water Management

The hydrogen‐iron (HyFe) flow cell has great potential for long‐duration energy storage by capitalizing on the advantages of both electrolyzers and flow batteries. However, its operation at high current density (high power) and over continuous cycling testing has yet to be demonstrated. In this article, we discuss our design and demonstration of a water‐management strategy that supports high current and long‐cycling performance of a HyFe flow cell. Water molecules associated with the movement of protons from the iron electrode to the hydrogen electrode are sufficient to hydrate the membrane and electrode at a low current density of 100 mA cm −2 during the charge process. At higher charge current density, more aggressive measures must be taken to counter back‐diffusion driven by the acid concentration gradient between the iron and hydrogen electrodes. Our water‐management approach is based on water vapor feeding in the hydrogen electrode and water evaporation in the iron electrode, thus enabling high current density operation of 300 mA cm −2 .

Yan, Litao↗

A Hydrogen Iron Flow Battery with High Current Density and Long Cyclability Enabled Through Circular Water Management

The hydrogen‐iron (HyFe) flow cell has great potential for long‐duration energy storage by capitalizing on the advantages of both electrolyzers and flow batteries. However, its operation at high current density (high power) and over continuous cycling testing has yet to be demonstrated. In this paper, we discuss our design and demonstration of a water management strategy that supports high current and long cycling performance of a HyFe flow cell. Water molecules associated with the movement of protons from the iron electrode to the hydrogen electrode are sufficient to hydrate the membrane and electrode at a low current density of 100 mA cm −2 during the charge process. At higher charge current density, more aggressive measures must be taken to counter back‐diffusion driven by the acid concentration gradient between the iron and hydrogen electrodes. Our water management approach is based on water vapor feeding in the hydrogen electrode, and water evaporation in the iron electrode, thus enabling the high current density operation of 300 mA cm −2 .

25 ENERGY STORAGE↗

Electron density profile measurements at a self-focusing ion beam with high current density and low energy extracted through concave electrodes

The self-focusing phenomenon has been observed in a high current density and low energy ion beam. In order to study the mechanism of this phenomenon, a special designed double probe to measure the electron density and temperature is installed into the chamber where the high current density ion beam is injected. Electron density profile is successfully measured without the influence of the ion beam components. Estimated electron temperature and density are ∼0.9 eV and ∼8 × 10{sup 8} cm{sup −3} at the center of ion beam cross section, respectively. It was found that a large amount of electrons are spontaneously accumulated in the ion beam line in the case of self-forcing state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗