In-Space technology experiments program. A high efficiency thermal interface (using condensation heat transfer) between a 2-phase fluid loop and heatpipe radiator: Experiment definition phase

Space Station elements and advanced military spacecraft will require rejection of tens of kilowatts of waste heat. Large space radiators and two-phase heat transport loops will be required. To minimize radiator size and weight, it is critical to minimize the temperature drop between the heat source and sink. Under an Air Force contract, a unique, high-performance heat exchanger is developed for coupling the radiator to the transport loop. Since fluid flow through the heat exchanger is driven by capillary forces which are easily dominated by gravity forces in ground testing, it is necessary to perform microgravity thermal testing to verify the design. This contract consists of an experiment definition phase leading to a preliminary design and cost estimate for a shuttle-based flight experiment of this heat exchanger design. This program will utilize modified hardware from a ground test program for the heat exchanger.

Pohner, John A.↗

A Massive Shell of Supernova-Formed Dust in SNR G54.1+0.3

While theoretical models of dust condensation predict that most refractory elements produced in core-collapsesupernovae (SNe) efficiently condense into dust, a large quantity of dust has so far only been observed inSN1987A. We present an analysis of observations from the Spitzer Space Telescope, Herschel SpaceObservatory, Stratospheric Observatory for Infrared Astronomy, and AKARI of the infrared shell surrounding thepulsar wind nebula in the supernova remnant G54.1+0.3. We attribute a distinctive spectral feature at 21 m to amagnesium silicate grain species that has been invoked in modeling the ejecta-condensed dust in Cas A, whichexhibits the same spectral signature. If this species is responsible for producing the observed spectral feature andaccounts for a significant fraction of the observed infrared continuum, we find that it would be the dominantconstituent of the dust in G54.1+0.3, with possible secondary contributions from other compositions, such ascarbon, silicate, or alumina grains. The total mass of SN-formed dust required by this model is at least 0.3Me. Wediscuss how these results may be affected by varying dust grain properties and self-consistent grain heating models.The spatial distribution of the dust mass and temperature in G54.1+0.3 confirms the scenario in which the SNformeddust has not yet been processed by the SN reverse shock and is being heated by stars belonging to a clusterin which the SN progenitor exploded. The dust mass and composition suggest a progenitor mass of 1627Me andimply a high dust condensation efficiency, similar to that found for Cas A and SN1987A. The study providesanother example of significant dust formation in a Type IIP SN explosion and sheds light on the properties ofpristine SN-condensed dust.

Temim, Tea↗

Thermal-To-Electric Converter With Greater Power Density

Proposed design for alkali-metal thermal-to-electric converter (AMTEC) incorporates refinements to increase power density and reduce input temperature below typical prior design. Converter has compact, planar configuration. Cells stacked densely with remote condenser for thermal efficiency and high power density. Either liquid- or vapor-fed cells utilized. Heat fed-in at lower temperature.

Williams, Roger M.↗

MATRIX-VBS Condensing Organic Aerosols in an Aerosol Microphysics Model

The condensation of organic aerosols is represented in a newly developed box-model scheme, where its effect on the growth and composition of particles are examined. We implemented the volatility-basis set (VBS) framework into the aerosol mixing state resolving microphysical scheme Multiconfiguration Aerosol TRacker of mIXing state (MATRIX). This new scheme is unique and advances the representation of organic aerosols in models in that, contrary to the traditional treatment of organic aerosols as non-volatile in most climate models and in the original version of MATRIX, this new scheme treats them as semi-volatile. Such treatment is important because low-volatility organics contribute significantly to the growth of particles. The new scheme includes several classes of semi-volatile organic compounds from the VBS framework that can partition among aerosol populations in MATRIX, thus representing the growth of particles via condensation of low volatility organic vapors. Results from test cases representing Mexico City and a Finish forrest condistions show good representation of the time evolutions of concentration for VBS species in the gas phase and in the condensed particulate phase. Emitted semi-volatile primary organic aerosols evaporate almost completely in the high volatile range, and they condense more efficiently in the low volatility range.

Aerosols↗

Microbial Anomalies Encountered on the International Space Station

Microorganisms in our living environments are unavoidable. A community of microbes arrived in space with the delivery of the first element of the International Space Station (ISS), attached to hardware and on the bodies of the humans tasked with the initial assembly missions. The risk that microorganisms could cause adverse effects in the health of both the human occupants of the ISS as well as the physical integrity of the station environment and life support systems has been both a driver and a function of engineering and operational controls. Scientists and engineers at NASA have gone to extensive measures to control microbial growth at levels safe for the crewmembers and the spacecraft environment. Many of these measures were initiated with the design of the spacecraft and its systems. Materials used in the ISS were tested for resistance to fungi, such as mold and a paint with a fungus-killing chemical was also used. Controlling the humidity of the air in the Station is also an effective way of discouraging microbe growth. The breathing air is reconditioned by the Environmental Control Life Support System (ECLSS) prior to distribution, utilizing High Efficiency Particulate Air (HEPA) filtration. Requirements restricting the accumulation of water condensate in the air handlers and habitable volume of the ISS were other safeguards added. Water for drinking and food rehydration is disinfected or filtered. A robust in-flight housekeeping regimen for the ISS significantly reduces inappropriate growth of microorganisms and includes a regular cleaning of accessible surfaces with disinfectant wipes. Most of these requirements were suggested by microbiologists to mitigate and possibly prevent many microbiological risks. In addition to these controls, before flight monitoring and analyses of the cabin air, exposed surfaces, water and food, consumables, and crew members are conducted to mitigate microbial risk to the crew and spacecraft. Many microbial risks are much easier to identify and resolve before launch than during space flight. Although the focus has been on prevention of microbiologically related, not all problems can be anticipated. A number of microbial anomalies have occurred on ISS. This paper will discuss the occurrences, root-cause investigations, and mitigation steps taken to remediate the contamination.

Bruce, Rebekah J.↗

Condenser design for AMTEC power conversion

The condenser and the electrodes are the two elements of an alkali metal thermal-to-electric conversion (AMTEC) cell which most greatly affect the energy conversion performance. A condenser is described which accomplishes two critical functions in an AMTEC cell: management of the fluid under microgravity conditions and optimization of conversion efficiency. The first function is achieved via the use of a controlled surface shape, along with drainage grooves and arteries to collect the fluid. Capillary forces manage the fluid in microgravity and dominate hydrostatic effects on the ground so the device is ground-testable. The second function is achieved via a smooth film of highly reflective liquid sodium on the condensing surface, resulting in minimization of parasitic heat losses due to radiation heat transfer. Power conversion efficiencies of 25 percent to 30 percent are estimated with this condenser using present technology for the electrodes.

Crowley, Christopher J.↗

Possible precipitation of ice at low latitudes of Mars during periods of high obliquity

Most of the old cratered highlands of Mars are dissected by branching river valleys that appear to have been cut by running water, yet liquid water is unstable everywhere on the Martian surface. In the equatorial region, where most of the valleys are observed, even ice is unstable. It has been suggested, therefore, that Mars had an early denser atmosphere with sufficient greenhouse warming to allow the existence of liquid water. Here, it is suggested instead that during periods of very high obliquities, ice could accumulate at low latitudes as a result of sustained sublimation of ice from the poles and transport of the water vapor equatorwards. At low latitudes, the water vapor would saturate the atmosphere and condense onto the surface, where it would accumulate until lower obliquities prevailed. The mechanism is efficient only at the very high obliquities that occurred before formation of Tharsis very early in the planet's history, but limited equatorial ice accumulation could also have occurred at the highest obliquities during the rest of the planet's history. Partial melting of the ice could have provided runoff to form the channels or replenish the groundwater system.

Jakosky, B. M.↗

Rapid Development of Instrument Thermal Models: Perspectives and Guidelines from NASA Goddard’s Instrument Design Laboratory

The Instrument Design Laboratory (IDL), part of NASA Goddard Space Flight Center’s Integrated Design Center (IDC), is a concurrent and collaborative environment which allows for rapid development of science instrumentation concepts within the span of less than two weeks. Science goals set by a Principal Investigator from government, industry or academia are translated into engineering requirements, from which a team of engineers spanning multiple disciplines use an established study process and a suite of analysis tools to work towards an instrument point design. As part of this process, a staff thermal engineer is tasked with designing a thermal control system which meets all incoming thermal requirements, while iterating real-time with other subsystems to ensure compatibility and functionality as a completed system. Thermal engineers on spaceflight projects typically have weeks or months to develop thermal models. However, the severe time limitation in this conceptual study setting makes thermal design particularly difficult, as rapid thermal modeling solely over the span of a few days is required to develop the instrument thermal design and understand the performance over its intended mission, especially if the instrument concept contains multiple thermal challenges such as dynamic environments or high heat dissipating components. In this paper, the authors provide a condensed guide for the most efficient ways to develop thermal models and conduct thermal analysis within the span of one-to-two weeks, as informed by decades of design experience and best practices in the IDL. The authors also focus on quick methods for determining worst-case thermal environments, deciding which modeling details are essential at this early phase, and quantifying the engineering resources necessary for thermal control. This paper concludes with specific thermal design tips for different instrument types across the electromagnetic spectrum.

Kan Yang↗

Turbulent flow model for vapor collection efficiency of a high-purity silicon reactor

In this study a mathematical model and a computer code based on this model was developed to allow prediction of the product distribution in chemical reactors for converting gaseous silicon compounds to condensed-phase silicon. Specifically, the model formulated describes the silicon vapor separation/collection from the developing turbulent flow stream within reactors of the Westinghouse type. Migration of the silicon vapor to the reactor walls was described by the parametric solutions presented here, in order to reduce the experimentation necessary in the design of such reactors. Calculations relating to the collection efficiencies of such reactors are presented as a function of the reactor throughflow and distance along its length.

Srivastava, R.↗

Temperature-Staged Thermal Energy Storage Enabling Low Thermal Exergy Loss Reflux Boiling in Full Spectrum Solar Systems

Hybrid full spectrum solar systems (FSSS) designed to capture and convert the full solar wavelength spectrum use hybrid solar photovoltaic/thermodynamic cycles that require low thermal exergy loss systems capable of transferring high thermal energy rates and fluxes with very low temperature differentials and losses. One approach to achieving this capability are high-heat-flux reflux boiling systems that take advantage of high heat transfer boiling and condensation mechanisms. Advanced solar systems are also intermittent by their nature and their electrical generation is often out-of-phase with electric utility power demand, and their required power system cycling reduces efficiency, performance (dispatch ability), lifetime, and reliability. High temperature thermal energy storage (TES) at 300-600°C enables these reflux boiling systems to simultaneously store thermal energy internally to increase the energy dispatch ability of the associated solar system, as this can increase the power generation profile by several hours (up to 6-10 hours) per day. Many TES phase change materials (PCM’s) exist including KNO3, NaNO3, LiBr/KBr, MgCl2/NaCl/KCl, Zn/Mg, and CuCl/NaCl, which have various operating melting points and different latent heats of fusion. Common, cost effective TES PCM's are FeCl2/NaCl/KCl mixtures, whose phase change temperature can be varied and controlled by simple composition adjustments. This paper presents and discusses unique "temperature-staged" thermal energy storage configurations using these TES materials and analysis of such systems integrated into high-heat-flux reflux boiling systems. In this specific application, the TES materials are designed to operate at staged temperatures surrounding an operating design point near 350°C, while providing 18 kW of source heat transfer to operate a thermoacoustic power system during off-sun conditions (e.g., temporary cloud conditions, after sun-down). This work discusses relevant configurations, and critical thermal and entropy models of the TES configurations, which show the inherent minimization of thermal exergy during critical heat transfers within the configurations and systems envisioned.

Hendricks, Terry J.↗

Space vehicle thermal rejection system

A space vehicle thermal heat rejection system 10 utilizing separate optimized heat pipe components for the functions of heat acquisition, heat transport, and heat rejection. A honeycomb panel heat pipe evaporator section 20 performs the function of heat acquisition, and forms a closed thermodynamic system with a dual channel heat pipe transport section 30, which performs the function of heat transport. A plurality of truss or channel core heat pipe rejection fins 41 form the condenser section 40, which performs the function of heat rejection. A common wall 32 separates the condenser section 40 from the transport section 30. Using the above heat pipe components and having efficient interfacing between them results in high performance factors for the overall system.

Tanzer, Herbert J.↗

New Particle Formation and Growth to Climate‐Relevant Aerosols at a Background Remote Site in the Western Himalaya

New particle formation (NPF) can influence the Earth's radiative budget when the newly formed particles grow to climate‐relevant sizes. Here, we present analysis of 21 months of continuous aerosol size distribution measurements at a background remote site in the western Himalaya and provide observational evidence that newly formed particles grow to cloud condensation nuclei (CCN)‐active sizes (i.e., >20–100 nm in diameter). Out of total 55 NPF events, 38 (66%) events occurred in the pre‐monsoon season (March–May). NPF events were classified into those with and without pollution influence as polluted and cleaner, respectively, using black carbon data. The analysis of air mass age, based on the ratio of number concentration of Aitken to accumulation mode aerosols, indicated that NPF occurred in the relatively cleaner air masses reaching to the site. The median formation rate of 10 nm particles and particle growth rates for cleaner events were three‐fold and two‐fold, respectively, higher than polluted events. We present the first estimates of the survival probability of newly formed particles to 50 and 100 nm size, which was not attempted in an Indian environment previously. The survival probability to 50 nm particles ranged from 44% to 98%, with a mean and standard deviation of 82 ± 18%. On average, ∼60% of the particles surviving to 50 nm survived to 100 nm, making the overall survival probability of 100 nm to 53 ± 31%. This indicates that the probability of nucleated particles growing to CCN‐active sizes under a large source of condensing vapor (transported from nearby lower‐altitude regions) and low pre‐existing particle concentrations (background mountain site) is high compared to the previous studies. These findings highlight the importance of the efficiency of nucleation events for producing CCN, which is a critical basis of aerosol indirect effects.

cloud condensation nuclei↗

Laser Processed Heat Exchangers

The Laser Processed Heat Exchanger project will investigate the use of laser processed surfaces to reduce mass and volume in liquid/liquid heat exchangers as well as the replacement of the harmful and problematic coatings of the Condensing Heat Exchangers (CHX). For this project, two scale unit test articles will be designed, manufactured, and tested. These two units are a high efficiency liquid/liquid HX and a high reliability CHX.

Hansen, Scott↗

Efficient baffle prevents oil backstreaming in diffusion pumps

High vacuum diffusion pump baffle, positioned immediately above pump stack, prevents vaporized pumping oil from entering and contaminating test chamber. Pumping vapors are collected and condensed on the baffle and flow back to pump base reservoir.

Meneghetti, J. R.↗

AMTEC vapor-vapor series connected cells

An alkali metal thermoelectric converter (AMTEC) having a plurality of cells structurally connected in series to form a septum dividing a plenum into two chambers, and electrically connected in series, is provided with porous metal anodes and porous metal cathodes in the cells. The cells may be planar or annular, and in either case a metal alkali vapor at a high temperature is provided to the plenum through one chamber on one side of the wall and returned to a vapor boiler after condensation at a chamber on the other side of the wall in the plenum. If the cells are annular, a heating core may be placed along the axis of the stacked cells. This arrangement of series-connected cells allows efficient generation of power at high voltage and low current.

Underwood, Mark L.↗

Wideband, high efficiency optical modulator requires less than 10 watts drive power

Wideband optical modulation system operates with less than 10-watts drive power. It consists of an optical modulator and transistorized driver that combines small cross-section potassium dideuterium phosphate crystals with laser beam-condensing optics. Optical modulation systems may serve importantly in future space wideband communication systems.

Becknell, W. E.↗

Space station static and dynamic analyses using parallel methods

Algorithms for high-performance parallel computers are applied to perform static analyses of large-scale Space Station finite-element models (FEMs). Several parallel-vector algorithms under development at NASA Langley are assessed. Sparse matrix solvers were found to be more efficient than banded symmetric or iterative solvers for the static analysis of large-scale applications. In addition, new sparse and 'out-of-core' solvers were found superior to substructure (superelement) techniques which require significant additional cost and time to perform static condensation during global FEM matrix generation as well as the subsequent recovery and expansion. A method to extend the fast parallel static solution techniques to reduce the computation time for dynamic analysis is also described. The resulting static and dynamic algorithms offer design economy for preliminary multidisciplinary design optimization and FEM validation against test modes. The algorithms are being optimized for parallel computers to solve one-million degrees-of-freedom (DOF) FEMs. The high-performance computers at NASA afforded effective software development, testing, efficient and accurate solution with timely system response and graphical interpretation of results rarely found in industry. Based on the author's experience, similar cooperation between industry and government should be encouraged for similar large-scale projects in the future.

Gupta, V.↗

Modeling Geometric Arrangements of TiO2-Based Catalyst Substrates and Isotropic Light Sources to Enhance the Efficiency of a Photocatalystic Oxidation (PCO) Reactor

The closed confined environments of the ISS, as well as in future spacecraft for exploration beyond LEO, provide many challenges to crew health. One such challenge is the availability of a robust, energy efficient, and re-generable air revitalization system that controls trace volatile organic contaminants (VOCs) to levels below a specified spacecraft maximum allowable concentration (SMAC). Photocatalytic oxidation (PCO), which is capable of mineralizing VOCs at room temperature and of accommodating a high volumetric flow, is being evaluated as an alternative trace contaminant control technology. In an architecture of a combined air and water management system, placing a PCO unit before a condensing heat exchanger for humidity control will greatly reduce the organic load into the humidity condensate loop ofthe water processing assembly (WPA) thereby enhancing the life cycle economics ofthe WPA. This targeted application dictates a single pass efficiency of greater than 90% for polar VOCs. ~ Although this target was met in laboratory bench-scaled reactors, no commercial or SBIR-developed prototype PCO units examined to date have achieved this goal. Furthermore, the formation of partial oxidation products (e.g., acetaldehyde) was not eliminated. It is known that single pass efficiency and partial oxidation are strongly dependent upon the contact time and catalyst illumination, hence the requirement for an efficient reactor design. The objective of this study is to maximize the apparent contact time and illuminated catalyst surface area at a given reactor volume and volumetric flow. In this study, a Ti02-based photocatalyst is assumed to be immobilized on porous substrate panels and illumination derived from linear isotropic light sources. Mathematical modeling using computational fluid dynamics (CFD) analyses were performed to investigate the effect of: 1) the geometry and configuration of catalyst-coated substrate panels, 2) porosity of the supporting substrate, and 3) varying the light source and spacing on contact time and illuminated catalyst area.

Richards, Jeffrey T.↗