Search NASA⌕ Search

SEARCH · Search NASA

Results for “high energy (linear accelerators, synchrotrons)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Relative Efficiency of TLD-100 to High Linear Energy Transfer Radiation: Correction to Astronaut Absorbed Dose

Response of thermoluminescent detectors (TLD-100) to high linear energy transfer (LET) particles has been studied using helium, carbon, silicon, and iron ions from the Heavy Ion Medical Accelerator at Chiba (Japan), iron ions from the Brookhaven National Laboratory (NY) Alternate Gradient Synchrotron, and 53, 134, 185, and 232 MeV protons from the Loma Linda accelerator. Using the measured relative (to 137Cs) dose efficiency, and measured LET spectra from a tissue equivalent proportional counter (TEPC) on 20 Space Shuttle flights, and 7 Mir flights, the underestimation of absorbed dose by these detectors has been evaluated. The dose underestimation is between 15-20% depending upon the flight inclination and shielding location. This has been confirmed by direct correlation of measured dose by TEPC and TLD-100 at a low shielded location in the Shuttle mid-deck. A comparison of efficiency- LET data with a compilation of similar data from TLD-700, shows that shapes of the two curves are nearly identical, but that the TLD-100 curve is systematically lower by about 13%, and is the major cause of dose underestimation. These results strongly suggest that TLDs used for crew dose estimation be regularly calibrated using heavy ions.

Badhwar, G. D.↗

Relative Efficiency of TLD-100 to Linear Energy Transfer Radiation: Correction to Astronaut Absorbed Dose

Response of thermoluminescent detectors (TLD-100) to high linear energy transfer (LET) particles has been studied using helium, carbon, silicon, and iron ions from the Heavy Ion Medical Accelerator at Chiba (Japan), iron ions from the Brookhaven National Laboratory (NY) Alternate Gradient Synchrotron, and 53, 134, 185, and 232 MeV protons from the Loma Linda accelerator. Using the measured relative (to (137)Cs dose efficiency, and measured LET spectra from a tissue equivalent proportional counter (TEPC) on 20 Space Shuttle flights, and 7 Mir flights, the underestimation of absorbed dose by these detectors has been evaluated. The dose underestimation is between 15-20% depending upon the flight inclination and shielding location. This has been confirmed by direct correlation of measured dose by TEPC and TLD-100 at a low shielded location in the Shuttle mid-deck. A comparison of efficiency- LET data with a compilation of similar data from TLD-700, shows that shapes of the two curves are nearly identical, but that the TLD-100 curve is systematically lower by about 13%, and is the major cause of dose underestimation. These results strongly suggest that TLDs used for crew dose estimation be regularly calibrated using heavy ions.

Badhwar, Gautam D.↗

Cell killing and chromatid damage in primary human bronchial epithelial cells irradiated with accelerated 56Fe ions

We examined cell killing and chromatid damage in primary human bronchial epithelial cells irradiated with high-energy 56Fe ions. Cells were irradiated with graded doses of 56Fe ions (1 GeV/nucleon) accelerated with the Alternating Gradient Synchrotron at Brookhaven National Laboratory. The survival curves for cells plated 1 h after irradiation (immediate plating) showed little or no shoulder. However, the survival curves for cells plated 24 h after irradiation (delayed plating) had a small initial shoulder. The RBE for 56Fe ions compared to 137Cs gamma rays was 1.99 for immediate plating and 2.73 for delayed plating at the D10. The repair ratio (delayed plating/immediate plating) was 1.67 for 137Cs gamma rays and 1.22 for 56Fe ions. The dose-response curves for initially measured and residual chromatid fragments detected by the Calyculin A-mediated premature chromosome condensation technique showed a linear response. The results indicated that the induction frequency for initially measured fragments was the same for 137Cs gamma rays and 56Fe ions. On the other hand, approximately 85% of the fragments induced by 137Cs gamma rays had rejoined after 24 h of postirradiation incubation; the corresponding amount for 56Fe ions was 37%. Furthermore, the frequency of chromatid exchanges induced by gamma rays measured 24 h after irradiation was higher than that induced by 56Fe ions. No difference in the amount of chromatid damage induced by the two types of radiations was detected when assayed 1 h after irradiation. The results suggest that high-energy 56Fe ions induce a higher frequency of complex, unrepairable damage at both the cellular and chromosomal levels than 137Cs gamma rays in the target cells for radiation-induced lung cancers.

NASA Discipline Radiation Health↗

The X-Ray Polarization View of Mrk 421 in an Average Flux State as Observed By the Imaging X-Ray Polarimetry Explorer

Particle acceleration mechanisms in supermassive black hole jets, such as shock acceleration, magnetic reconnection, and turbulence, are expected to have observable signatures in the multiwavelength polarization properties of blazars. The recent launch of the Imaging X-Ray Polarimetry Explorer (IXPE) enables us, for the first time, to use polarization in the X-ray band (2–8 keV) to probe the properties of the jet synchrotron emission in high-synchrotron-peaked BL Lac objects (HSPs). We report the discovery of X-ray linear polarization (degree Π x = 15% ± 2% and electric vector position angle ψ x = 35° ± 4°) from the jet of the HSP Mrk 421 in an average X-ray flux state. At the same time, the degree of polarization at optical, infrared, and millimeter wavelengths was found to be lower by at least a factor of 3. During the IXPE pointing, the X-ray flux of the source increased by a factor of 2.2, while the polarization behavior was consistent with no variability. The higher level of Π x compared to longer wavelengths, and the absence of significant polarization variability, suggest a shock is the most likely X-ray emission site in the jet of Mrk 421 during the observation. The multiwavelength polarization properties are consistent with an energy-stratified electron population, where the particles emitting at longer wavelengths are located farther from the acceleration site, where they experience a more disordered magnetic field.

acceleration of particles↗

Physics of Rotation Powered Pulsars and Their Nebulae

This letter is my progress report for the Astrophysics Theory grant. The first goal of the research supported by this grant is to produce a time dependent theory of the unsteady relativistic collisionless shock wave terminating the relativistic wind from a pulsar, and compare the predicted surface brightness fluctuations to Hubble Space Telescope observations of the wisps in the Crab Nebula. The second goal is to model the production of electron-positron pairs over the polar caps of rotation powered pulsars, and use the results to predict the heating of the surface due to particle trapping and bombardment of the atmosphere at the base of the polar field lines. We have succeeded in creating a one dimensional hybrid code, in which the electron-positron pairs incident on the shock structure are modeled as a relativistic, adiabatic, ideal MHD fluid, while the heavy ions are treated as particles using a particle-in-cell algorithm. The electromagnetic fields are evaluated from the currents and charge densities in the pairs and the ions, while the particles and the fluid accelerate in response to the computed self-consistent electromagnetic fields. The results are promising, in that the underlying ion cyclotron instability generates finite amplitude, propagating magnetosonic waves in the pairs, whose wavelengths and frequencies, when translated into physical units, are comparable to the observed running waves of brightness observed by HST near the Crab pulsar. The code is undergoing a number of tests, to assure us that this preliminary correspondence is not an artifact. In the coming year, the observational appearance of the models will be computed and compared to the HST observations of the Crab now in hand, and used to predict the HST results which will be obtained the year after next. WE also developed a one dimensional cascade theory for pair creation over pulsars' polar caps. A linear integral equation describing the synchrotron cascade has been derived and solved by iterative techniques, in the case when a high energy electron moving parallel to a star centered dipole magnetic field initiates the cascade through curvature gamma ray emission.

Arons, Jonathan↗

Effect of track structure and radioprotectors on the induction of oncogenic transformation in murine fibroblasts by heavy ions

The oncogenic potential of high-energy 56Fe particles (1 GeV/nucleon) accelerated with the Alternating Gradient Synchrotron at the Brookhaven National Laboratory was examined utilizing the mouse C3H 10T1/2 cell model. The dose-averaged LET for high-energy 56Fe is estimated to be 143 keV/micrometer with the exposure conditions used in this study. For 56Fe ions, the maximum relative biological effectiveness (RBEmax) values for cell survival and oncogenic transformation were 7.71 and 16.5 respectively. Compared to 150 keV/micrometer 4He nuclei, high-energy 56Fe nuclei were significantly less effective in cell killing and oncogenic induction. The prostaglandin E1 analog misoprostol, an effective oncoprotector of C3H 10T1/2 cells exposed to X rays, was evaluated for its potential as a radioprotector of oncogenic transformation with high-energy 56Fe. Exposure of cells to misoprostol did not alter 56Fe cytotoxicity or the rate of 56Fe-induced oncogenic transformation.

NASA Discipline Radiation Health↗

Evaluation of risk from space radiation with high-energy heavy ion beams

The most challenging radiation in space consists of fully ionized atomic elements with high energy for which only the few lowest energy ions can be stopped in shielding materials. The health risk from exposure to these ions and their secondary radiations generated in shield materials is poorly understood since there are few human data and a systematic study in relevant animal model systems has not been made. The accuracy of risk prediction is described as the major limiting factor in the management of space radiation risk. The expected impact of systematic studies is examined using the limited available biological data and models. Given the limitations of current predictions, models must be developed that are able to incorporate the required fundamental scientific data into accurate risk estimates. The important radiation components that can be provided for laboratory testing are identified. The use of ground-based accelerator beams to simulate space radiation is explained and quantitative scientific constraints on such facilities are derived. Three facilities, one each in the United States, in Germany and in Japan, currently have the partial capability to satisfy these constraints. A facility has been proposed using the Brookhaven National Laboratory Booster Synchrotron in the United States; in conjuction with other on-site accelerators, it will be able to provide the full range of heavy ion beams and energies required.

NASA Discipline Radiation Health↗