Search NASA⌕ Search

SEARCH · Search NASA

Results for “high field sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Measurements of displacement around holes in composite plates subjected to quasi-static compression

Attempts to develop a whole-field, high sensitivity optical technque for measurement of load induced changes of thickness of composite plates are described. Graphite-epoxy plates of quasi-isotropic layup were used as test specimens. Changes of thickness of three plates, each with a central hole of different size, were measured as a function of applied compressive loads. The first test specimen showed localized zones where no holographic fringes were present, surrounded by zones of low fringe contrast. This was thought to be a result of localized motion or creep. Subsequent tests with an increased time interval between specimen loading and holographic exposure demonstrated no localized zones of absent fringes. No plausible explanation for radical differences in the quality of fringe patterns was found, although the use of specimens having a high quality mirrorized surface provided superior change of thickness patterns. Recommendations for further investigations and changes in test procedure are presented.

Duke, J. C., Jr.↗

Deep Flaw Detection with Giant Magnetoresistive (GMR) Based Self-Nulling Probe

In this paper a design modification to the Very-Low Frequency GMR Based Self-Nulling Probe has been presented to enable improved signal to noise ratio for deeply buried flaws. The design change consists of incorporating a feedback coil in the center of the flux focusing lens. The use of the feedback coil enables cancellation of the leakage fields in the center of the probe and biasing of the GMR sensor to a location of high magnetic field sensitivity. The effect of the feedback on the probe output was examined, and experimental results for deep flaw detection were presented. The experimental results show that the modified probe is capable of clearly identifying flaws up to 1 cm deep in aluminum alloy structures.

Wincheski, Buzz↗

Magnetoresistive Flux Focusing Eddy Current Flaw Detection

A giant magnetoresistive flux focusing eddy current device effectively detects deep flaws in thick multilayer conductive materials. The probe uses an excitation coil to induce eddy currents in conducting material perpendicularly oriented to the coil s longitudinal axis. A giant magnetoresistive (GMR) sensor, surrounded by the excitation coil, is used to detect generated fields. Between the excitation coil and GMR sensor is a highly permeable flux focusing lens which magnetically separates the GMR sensor and excitation coil and produces high flux density at the outer edge of the GMR sensor. The use of feedback inside the flux focusing lens enables complete cancellation of the leakage fields at the GMR sensor location and biasing of the GMR sensor to a location of high magnetic field sensitivity. In an alternate embodiment, a permanent magnet is positioned adjacent to the GMR sensor to accomplish the biasing. Experimental results have demonstrated identification of flaws up to 1 cm deep in aluminum alloy structures. To detect deep flaws about circular fasteners or inhomogeneities in thick multi-layer conductive materials, the device is mounted in a hand-held rotating probe assembly that is connected to a computer for system control, data acquisition, processing and storage.

Russell A Wincheski↗

Magnetoresistive flux focusing eddy current flaw detection

A giant magnetoresistive flux focusing eddy current device effectively detects deep flaws in thick multilayer conductive materials. The probe uses an excitation coil to induce eddy currents in conducting material perpendicularly oriented to the coil's longitudinal axis. A giant magnetoresistive (GMR) sensor, surrounded by the excitation coil, is used to detect generated fields. Between the excitation coil and GMR sensor is a highly permeable flux focusing lens which magnetically separates the GMR sensor and excitation coil and produces high flux density at the outer edge of the GMR sensor. The use of feedback inside the flux focusing lens enables complete cancellation of the leakage fields at the GMR sensor location and biasing of the GMR sensor to a location of high magnetic field sensitivity. In an alternate embodiment, a permanent magnet is positioned adjacent to the GMR sensor to accomplish the biasing. Experimental results have demonstrated identification of flaws up to 1 cm deep in aluminum alloy structures. To detect deep flaws about circular fasteners or inhomogeneities in thick multilayer conductive materials, the device is mounted in a hand-held rotating probe assembly that is connected to a computer for system control, data acquisition, processing and storage.

Wincheski, Russell A.↗

A method for non-contact drop charge measurement

A new approach for detecting point type of charge has been developed. This system is based on the principle of reciprocal motion of a grounded conductor near a point charge. The current induced through such a process can then be used to determine the static field strength of the point charge, hence the quantity of the charge. Experiments were done to understand the characteristics of this new device. Test case indicates that the results are in good agreement with the theoretical prediction. This device shows extremely good linearity with respect to the strength of the input static field. The resolution of the system is better than 10 V/m, which is about two orders of magnitude in sensitivity higher than other types of field measuring apparatus. The high sensitivity of this system makes it possible to conduct charged drop experiments under microgravity conditions.

Lin, K. C.↗

Elastic-plastic deformation of a metal-matrix composite coupon with a center slot

A comprehensive experimental analysis of deformations of the surface of a metal-matrix specimen is reported. The specimen is a 6-ply 0 + or - 45 sub s boron-aluminum tensile coupon with a central slot. Moire interferometry is used for high-sensitivity whole-field measurements of in-plane displacements. Normal and shear strains are calculated from displacement gradients. Displacement fields are analyzed at various load levels from 15% to 95% of the failure load. Deformations of the boron fibers could be distinguished from those of the matrix. Highly localized plastic slip zones occur tangent to the ends of the slot. Shear strains and concurrent transverse compressive strains in the slip zones reach approximately 10% and 1%, respectively. Upon unloading, elastic recovery in surrounding regions causes a reverse plastic shear strain in the slip zone of about 4%. Longitudinal normal strains on the unslotted ligament peak at the slot boundary at about 1% strain. The strain concentration factor at the end of the slot decreases with load level and the advance of plasticity.

Post, D.↗

[Instrument Designs for SOFIA: FOCUS and FORCAST]

As a result of these studies a proposal for FORCAST was submitted to the SOFIA Announcement of Opportunity for Instruments. FORCAST, a facility instrument, was one of the winning proposals. A short description of FORCAST follows: (1) FORCAST is a dual-channel, high-sensitivity, wide-field camera designed to perform continuum imaging in the mid-infrared (4-8 microns) and far-infrared (16-40 microns). The pixels map to 0.75 sec. on the sky and the total field-of-view is 3.2 min. During normal operation a cold MgO dichroic allows imaging in two bands (16-25 and 25-40 microns) enabling high efficiency, simultaneous observations. For imaging at shorter wavelengths (4-8 microns), a mirror replaces the dichroic. FORCAST simultaneously operates two 256 x 256 Si BIB hybrid arrays from Boeing (formerly Rockwell). A Si:As BIB array is used for lambda less than 25 microns while a Si:Sb BIB array is use for lambda greater than 25 microns, FORCAST allows selection of the bandpass independently for each channel via filter wheels. Several specific filters are needed for the Pi science program. Selection of other filters will be based on input from the SOFIA science community. These can include filters to cover specific lines or dust features (such as the PAH features in the 4-8 microns regime). Future upgrades could include a polarimetric capability. The Pi team has extensive experience with all of the technologies used in FORCAST. FORCAST uses mature, low-risk, state-of-the-art technology ensuring highly reliability. In addition, FORCAST will be easy to set up for an observing run and easy to operate (with an intuitive graphical interface). We feel that we can virtually guarantee success on the first flight with FORCAST. FORCAST is designed to complement SIRTF (ISO will no longer be functional). While it cannot achieve the sensitivity levels of SIRTF, FORCAST covers sections of phase space not planned for SIRTF (30-40 microns imaging) and has significantly higher spatial resolution than SIRTF at all wavelengths.

Source record↗

Experimental Investigation of Textile Composite Materials Using Moire Interferometry

The viability as an efficient aircraft material of advanced textile composites is currently being addressed in the NASA Advanced Composites Technology (ACT) Program. One of the expected milestones of the program is to develop standard test methods for these complex material systems. Current test methods for laminated composites may not be optimum for textile composites, since the architecture of the textile induces nonuniform deformation characteristics on the scale of the smallest repeating unit of the architecture. The smallest repeating unit, also called the unit cell, is often larger than the strain gages used for testing of tape composites. As a result, extending laminated composite test practices to textiles can often lead to pronounced scatter in material property measurements. It has been speculated that the fiber architectures produce significant surface strain nonuniformities, however, the magnitudes were not well understood. Moire interferometry, characterized by full-field information, high displacement sensitivity, and high spatial resolution, is well suited to document the surface strain on textile composites. Studies at the NASA Langley Research Center on a variety of textile architectures including 2-D braids and 3-D weaves, has evidenced the merits of using moire interferometry to guide in test method development for textile composites. Moire was used to support tensile testing by validating instrumentation practices and documenting damage mechanisms. It was used to validate shear test methods by mapping the full-field deformation of shear specimens. Moire was used to validate open hole tension experiments to determine the strain concentration and compare then to numeric predictions. It was used for through-the-thickness tensile strength test method development, to verify capabilities for testing of both 2-D and 3-D material systems. For all of these examples, moire interferometry provided vision so that test methods could be developed with less speculation and more documentation.

Ifju, Peter G.↗

Application of the intensified CCD to airglow and auroral measurements

New detector technology exemplified by advanced CCD and intensified CCD (ICCD) systems have important advantages for both spectrographic and imaging research. However, to realize the full potential of this new technology, the detector and the optical system as a whole must be considered. It is frequently not enough to simply substitute an ICCD for an earlier detector; rather, to achieve optimum results, the optics must be adapted to the specific detector. Properly designed airglow spectrographs based on the ICCD detector offer the advantages of high throughput over a broad spectral range, precise wavelength stability, low noise, and compactness. Imagers having the wide field and the high sensitivity needed for airglow research are practical as well.

Broadfoot, A. L.↗

Airborne CO2 coherent lidar measurements of cloud backscatter and opacity over the ocean surface

The use of an airborne CO2 lidar to obtain cloud backscatter and extinction data at a thermal infrared wavelength is described. The extinction in this spectral region is proportional to the cloud liquid water content. The use of coherent detection results in high sensitivity and narrow field of view, the latter property greatly reducing multiple-scattering effects. Backscatter measurements in absolute units are obtained through a hard target calibration methodology. For clouds of low to moderate optical thickness at the lidar wavelength, both geometric thickness and optical thickness can be measured. The sea surface reflectance signal is used to obtain estimates of the cloud optical thickness. The utility of this technique results from studies that indicate that the spatial scale of variability of the sea surface reflectance is generally large compared with that of cloud optical thickness. Selected results are presented from data taken during flights over the Pacific Ocean.

Menzies, Robert T.↗

Remote Detection Sodium Cell Magnetometry Using Amplitude Modulated Light

We have investigated the performance of a remote-detection sodium cell magnetometer using synchronous optical pumping with amplitude modulated light. The magnetometer is used to measure ambient geomagnetic field with high-sensitivity using backscattered resonance fluorescence.

Line shapes and shifts and Spectroscopy↗

An XMM-Newton Early-type Galaxy Atlas

The distribution of hot interstellar medium in early-type galaxies(ETGs)bears the imprint of the various astrophysical processes it underwent during its evolution. The X-ray observations of these galaxies have identified various structural features related to active galactic nucleus(AGN)and stellar feedback and environmental effects such as merging and sloshing. In our XMM-Newton Galaxy Atlas(NGA)project, we analyze archival observations of 38 ETGs, utilizing the high sensitivity and large field of view of XMM-Newton to construct spatially resolved 2D spectral maps of the hot gas halos. To illustrate our NGA data products in conjunction with the Chandra Galaxy Atlas, we describe two distinct galaxies, NGC 4636 and NGC 1550, in detail. We discuss the revolutionary history with a particular focus on the asymmetric distribution of metal-enriched, low-entropy gas caused by sloshing and AGN-driven uplift. We will release the NGA data products to a dedicated website, from where users can download them to perform further analyses.

Nazma Islam↗

High degree gravitational sensitivity from Mars orbiters for the GMM-1 gravity model

Orbital sensitivity of the gravity field for high degree terms (greater than 30) is analyzed on satellites employed in a Goddard Mars Model GMM-1, complete in spherical harmonics through degree and order 50. The model is obtained from S-band Doppler data on Mariner 9 (M9), Viking Orbiter 1 (VO1), and Viking Orbiter 2 (VO2) spacecraft, which were tracked by the NASA Deep Space Network on seven different highly eccentric orbits. The main sensitivity of the high degree terms is obtained from the VO1 and VO2 low orbits (300 km periapsis altitude), where significant spectral sensitivity is seen for all degrees out through degree 50. The velocity perturbations show a dominant effect at periapsis and significant effects out beyond the semi-latus rectum covering over 180 degrees of the orbital groundtrack for the low altitude orbits. Because of the wideband of periapsis motion covering nearly 180 degrees in w and +39 degrees in latitude coverage, the VO1 300 km periapsis altitude orbit with inclination of 39 degrees gave the dominant sensitivity in the GMM-1 solution for the high degree terms. Although the VO2 low periapsis orbit has a smaller band of periapsis mapping coverage, it strongly complements the VO1 orbit sensitivity for the GMM-1 solution with Doppler tracking coverage over a different inclination of 80 degrees.

Lerch, F. J.↗

ISS-Lobster: A Proposed Wide-Field X-Ray Telescope on the International Space Station

The Lobster wide-field imaging telescope combines simultaneous high FOV, high sensitivity and good position resolution. These characteristics can open the field of X-Ray time domain astronomy, which will study many interesting transient sources, including tidal disruptions of stars, supernova shock breakouts, and high redshift gamma-ray bursts. Also important will be its use for the X-ray follow-up of gravitational wave detections. I will describe our present effort to propose the Lobster concept for deployment on the International Space Station through a NASA Mission of Opportunity this fall.

Camp, Jordan↗

Xenia Mission: Spacecraft Design Concept

The proposed Xenia mission will, for the first time, chart the chemical and dynamical state of the majority of baryonic matter in the universe. using high-resolution spectroscopy, Xenia will collect essential information from major traces of the formation and evolution of structures from the early universe to the present time. The mission is based on innovative instrumental and observational approaches: observing with fast reaction gamma-ray bursts (GRBs) with a high spectral resolution. This enables the study of their (star-forming) environment from the dark to the local universe and the use of GRBs as backlight of large-scale cosmological structures, observing and surveying extended sources with high sensitivity using two wide field-of-view x-ray telescopes - one with a high angular resolution and the other with a high spectral resolution.

Hopkins, R. C.↗

TPSAS-NF1676L-10746-DND

This paper presents the design, development, and field testing of a high sensitivity ground-based Differential Absorption Lidar (DIAL) system that was developed under the NASA Instrument Incubator Program. The investigation presents a significant advancement towards the development of future CO2 profiling capability as it incorporates key elements of technologies needed for a future development of global CO2 measuring systems including: (1) 2-μm laser technologies that have been developed under a number of NASA programs including the Laser Risk Reduction Program (LRRP) (2) A novel high quantum efficiency (QE), high gain (without excess noise factor), and low noise phototransistor, and (3) Direct detection DIAL system using a large collection area receiver that is insensitive to speckle and coherence length effects from atmospheric turbulence that influences heterodyne detection systems. The objective of the project was a system TRL of 4, and the goal was TRL 5. Development and testing of the laser, new detector, and receiver systems during the project, integration into a complete lidar system into a trailer, field testing of system at West Branch, IA and comparison of the lidar CO2 measurements with in situ sensors advanced the system to a TRL of 5. The system demonstrated high vertical resolution CO2 profiling capability within the boundary layer and column measurements to long ranges. This is the first direct detection demonstration of a 2-micron CO2 DIAL high vertical resolution capability from instrument concept to field demonstration.

Syed Ismail↗

ISS Ammonia Leak Detection Through X-Ray Fluorescence

Ammonia leaks are a significant concern for the International Space Station (ISS). The ISS has external transport lines that direct liquid ammonia to radiator panels where the ammonia is cooled and then brought back to thermal control units. These transport lines and radiator panels are subject to stress from micrometeorites and temperature variations, and have developed small leaks. The ISS can accommodate these leaks at their present rate, but if the rate increased by a factor of ten, it could potentially deplete the ammonia supply and impact the proper functioning of the ISS thermal control system, causing a serious safety risk. A proposed ISS astrophysics instrument, the Lobster X-Ray Monitor, can be used to detect and localize ISS ammonia leaks. Based on the optical design of the eye of its namesake crustacean, the Lobster detector gives simultaneously large field of view and good position resolution. The leak detection principle is that the nitrogen in the leaking ammonia will be ionized by X-rays from the Sun, and then emit its own characteristic Xray signal. The Lobster instrument, nominally facing zenith for its astrophysics observations, can be periodically pointed towards the ISS radiator panels and some sections of the transport lines to detect and localize the characteristic X-rays from the ammonia leaks. Another possibility is to use the ISS robot arm to grab the Lobster instrument and scan it across the transport lines and radiator panels. In this case the leak detection can be made more sensitive by including a focused 100-microampere electron beam to stimulate X-ray emission from the leaking nitrogen. Laboratory studies have shown that either approach can be used to locate ammonia leaks at the level of 0.1 kg/day, a threshold rate of concern for the ISS. The Lobster instrument uses two main components: (1) a microchannel plate optic (also known as a Lobster optic) that focuses the X-rays and directs them to the focal plane, and (2) a CCD (charge coupled device) focal plane detector that reads out the position and energy of the X-rays, allowing a determination of the leak location. The effective area of the detection system is approximately 2 cm(exp2) at 1 keV. The Lobster astrophysics instrument, designed for monitoring the sky for Xray transients, gives high sensitivity along with large field of view (30×30deg) and good spatial resolution (1 arc min). This offers a significant benefit for detecting ISS ammonia leaks, since the goal is to localize small leaks as efficiently as possible.

Camp, Jordan↗