Search NASA⌕ Search

SEARCH · Search NASA

Results for “high frame rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A video event trigger for high frame rate, high resolution video technology

When video replaces film the digitized video data accumulates very rapidly, leading to a difficult and costly data storage problem. One solution exists for cases when the video images represent continuously repetitive 'static scenes' containing negligible activity, occasionally interrupted by short events of interest. Minutes or hours of redundant video frames can be ignored, and not stored, until activity begins. A new, highly parallel digital state machine generates a digital trigger signal at the onset of a video event. High capacity random access memory storage coupled with newly available fuzzy logic devices permits the monitoring of a video image stream for long term or short term changes caused by spatial translation, dilation, appearance, disappearance, or color change in a video object. Pretrigger and post-trigger storage techniques are then adaptable for archiving the digital stream from only the significant video images.

Williams, Glenn L.↗

High resolution, high frame rate video technology development plan and the near-term system conceptual design

The objective of the High Resolution, High Frame Rate Video Technology (HHVT) development effort is to provide technology advancements to remove constraints on the amount of high speed, detailed optical data recorded and transmitted for microgravity science and application experiments. These advancements will enable the development of video systems capable of high resolution, high frame rate video data recording, processing, and transmission. Techniques such as multichannel image scan, video parameter tradeoff, and the use of dual recording media were identified as methods of making the most efficient use of the near-term technology.

Ziemke, Robert A.↗

First results from a high-frame-rate, multi-GHz ionizing particle detection system geared toward accelerator diagnostic applications

An integrated detection system, consists of a thin diamond sensor incorporated into a compact signal loop, coupled in turn to an application-specific integrated circuit readout chip, has been tested for the first time, using ps-duration electron pulses from the Next Linear Collider Test Accelerator at the SLAC National Accelerator Laboratory. For readout frame rates as high as 120 kHz, the detection system is shown to achieve a linear dynamic range of 10 3 and a bandwidth of 4–5 GHz, with no ringing seen on the tail of the output pulse. These results represent the best-performing multi-GHz ionizing particle detection system achieved to date.

Ferezghi, Mohammadreza Mohseni [University of Cali↗

High Resolution, High Frame Rate Video Technology

Papers and working group summaries presented at the High Resolution, High Frame Rate Video (HHV) Workshop are compiled. HHV system is intended for future use on the Space Shuttle and Space Station Freedom. The Workshop was held for the dual purpose of: (1) allowing potential scientific users to assess the utility of the proposed system for monitoring microgravity science experiments; and (2) letting technical experts from industry recommend improvements to the proposed near-term HHV system. The following topics are covered: (1) State of the art in the video system performance; (2) Development plan for the HHV system; (3) Advanced technology for image gathering, coding, and processing; (4) Data compression applied to HHV; (5) Data transmission networks; and (6) Results of the users' requirements survey conducted by NASA.

Source record↗

Data compression techniques applied to high resolution high frame rate video technology

An investigation is presented of video data compression applied to microgravity space experiments using High Resolution High Frame Rate Video Technology (HHVT). An extensive survey of methods of video data compression, described in the open literature, was conducted. The survey examines compression methods employing digital computing. The results of the survey are presented. They include a description of each method and assessment of image degradation and video data parameters. An assessment is made of present and near term future technology for implementation of video data compression in high speed imaging system. Results of the assessment are discussed and summarized. The results of a study of a baseline HHVT video system, and approaches for implementation of video data compression, are presented. Case studies of three microgravity experiments are presented and specific compression techniques and implementations are recommended.

Hartz, William G.↗

A Cryogenic readout integrated circuit with analog pile-up and in-Pixel ADC for high frame rate Skipper CCD-in-CMOS Sensors

The Skipper CCD-in-CMOS Parallel Read-Out Circuit V2 (SPROCKET2) is designed to enable high frame rate readout of Skipper CCD-in-CMOS image sensors. The SPROCKET2 pixel is fabricated in a 65 nm CMOS process and occupies a 60$\mu$m $\times$ 60$\mu$m footprint. SPROCKET2 is intended to be heterogeneously integrated with a pixelated Skipper CCD-in-CMOS sensor, such that one readout pixel is connected to a multiplexed array of 16 active image sensor pixels, to match their spatial geometry. Our design benefits from the Skipper CCD-in-CMOS sensor's non-destructive readout capability to achieve exceptionally low noise through multi-sampling and averaging while optimizing for total power consumption. The pixel readout utilizes correlated double sampling to minimize 1/f noise and includes "pile-up" of ten successive samples in the analog domain before digitizing at a rate of 66.7 ksps. Measurement results of in-pixel serial SAR ADC show DNL and INL of ~0. 44 LSB and 0.58 LBS respectively. A large area array of 20,000 SPROCKET2 ADC pixels (multiplexed 1:16 to 320,000 sensor pixels) is currently under test. By reading out data over a 10 Gbps optical link, this pixel design enables a frame rate of $\sim$ 4 kfps for large sensing areas with minimal sensing deadtime. In the highest gain mode, the pixelated ADC has an input-referred resolution of 10$\mu$V with a simulated power consumption of 50$\mu$W. The pixel operates with constant current draw to minimize power-rail crosstalk.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operational Limitations of the High Rate Frame Multiplexer (HRFM) Onboard the International Space Station(ISS)-and How These Limitations Affect Payload Developers (PDs) and International Partners (IPs)

The data system onboard the United States Operating Segment (USOS) of the ISS is currently used to capture, route, record and downlink high-rate science data from experiments inside the US Lab. Once NASDA's Japanese Experiment Module (JEM) and ESA's Attached Pressurized Module (APM) are launched - in the 2004 to 2005 timeframe - data from these facilities will also be routed to the ground using the USOS data system. A critical component of the USOS data system is the High Rate Frame Multiplexer (HRFM). The HRFM combines multiple data/video inputs and combines them into one data stream. This Ku-band data stream is then routed through the Tracking and Data Relay Satellite (TDRS) system to the ground. The Data Management Coordinator (DMC) - located at the Marshall Space Flight Center's Payload Operations Center (POC) - is responsible for commanding and controlling the HRFM. The HRFM can multiplex a maximum of eight digital data sources and four digital video sources. Thus far, this limitation has not been constraining to operations. However, once the JEM and APM are integrated, the HRFM limitations will become a major constraint to science operations onboard. The purpose of this paper is to characterize the limitations of the HRFM and to explain how these limitations can be successfully managed. With this information, Payload Developers and International Partners will be able to more effectively utilize the data systems onboard the ISS. Ultimately, more science data can be captured and downlinked to Flight Controllers and Scientists on the ground.

Mixson, Charles D.↗

VeryFastCCD: a high frame rate soft X-ray detector

Direct X-ray detection in silicon has been transformative for scattering experiments in biology and materials science. While bump-bonded hybrid pixels have been attractive for hard X-ray detection, the challenge for single photon soft X-ray detection is sufficiently low noise. CCD structures on thick, high-resistivity silicon have been successfully used as sensors over the range of soft to hard X-rays at storage rings and FELs. The VeryFastCCD is a high frame rate, column-parallel CCD sensor with 48 μm pixels. Combined with 256-channel custom readout ASICs, frame rates of 5–10 kHz have been achieved with readout noise as low as 20 e and full-well capacity >4 × 10 5 e/pixel. Thin (10 nm and 100 nm) entrance window contact processes have also been developed which provide >85% quantum efficiency for 285 eV X-rays. Systems are currently being developed for several beamlines at the upgraded Advanced Light Source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-BRB-10: New Generation of High Frame-Rate and High Spatial-Resolution EPID QA System for Full-Body MLC-Based Robotic Radiosurgery

Purpose: To systematically investigate an ultra-high spatial-resolution amorphous silicon flat-panel electronic portal imaging device (EPID) for MLC-based full-body robotic radiosurgery geometric and dosimetric quality assurance (QA). Methods: The high frame-rate and ultra-high spatial resolution EPID is an outstanding detector for measuring profiles, MLC-shaped radiosurgery field aperture verification, and small field dosimetry. A Monte Carlo based technique with a robotic linac specific response and calibration is developed to convert a raw EPID-measured image of a radiosurgery field into water-based dose distribution. The technique is applied to measure output factors and profiles for 6MV MLC-defined radiosurgery fields with various sizes ranging from 7.6mm×7.7mm to 100mm×100.1mm and the results are compared with the radiosurgery diode scan measurements in water tank. The EPID measured field sizes and the penumbra regions are analyzed to evaluate the MLC positioning accuracy. Results: For all MLC fields, the EPID measured output factors of MLC-shaped fields are in good agreement with the diode measurements. The mean output difference between the EPID and diode measurement is 0.05±0.87%. The max difference is −1.33% for 7.6mm×7.7mm field. The MLC field size derived from the EPID measurements are in good agreement comparing to the diode scan result. For crossline field sizes, the mean difference is −0.17mm±0.14mm with a maximum of −0.35mm for the 30.8mm×30.8mm field. For inline field sizes, the mean difference is +0.08mm±0.18mm with a maximum of +0.45mm for the 100mm×100.1mm field. The high resolution EPID is able to measure the whole radiation field, without the need to align the detector center perfectly at field center as diode or ion chamber measurement. The setup time is greatly reduced so that the whole process is possible for machine and patient-specific QA. Conclusion: The high spatial-resolution EPID is proved to be an accurate and efficient tool for QA of MLC-equipped robotic radiosurgery system.

60 APPLIED LIFE SCIENCES↗

Rapid Fabrication of High Frame Rate Multichannel FTIR Spectrometers

Spectrally resolved signals in the short- to mid-wave infrared (SWIR/MWIR) bands at high-temporal resolution are critical for many national security remote sensing missions. Currently available off the shelf technology can achieve either high temporal resolution or high spectral resolution, but rugged instruments that can achieve both simultaneously remain mostly in the realm of one-off R&D projects. This report documents efforts to demonstrate a new technique for designing and building high resolution, high framerate multichannel FTIR (MC-FTIR) spectrometers that operate in the SWIR/MWIR bands. The core optical element in a MC-FTIR spectrometer is an array of statically-tuned lamellar grating interferometers (LGI). In the original MC-FTIR work these arrays were fabricated using a synchrotron x-ray lithography method. We proposed to instead fabricate these LGI arrays using multiphoton lithography (MPL), a 3D printing technique that can fabricate meso-scale structures with sub-micron precision. Although we were able to fabricate LGI arrays of sufficient size using MPL, the realized optical surfaces had unsuitably high optical form errors, precluding their use in a fieldable instrument. Further advancement in MPL technology may eventually enable fabrication of interferometer-grade LGI arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced High-Definition Video Cameras

A product line of high-definition color video cameras, now under development, offers a superior combination of desirable characteristics, including high frame rates, high resolutions, low power consumption, and compactness. Several of the cameras feature a 3,840 2,160-pixel format with progressive scanning at 30 frames per second. The power consumption of one of these cameras is about 25 W. The size of the camera, excluding the lens assembly, is 2 by 5 by 7 in. (about 5.1 by 12.7 by 17.8 cm). The aforementioned desirable characteristics are attained at relatively low cost, largely by utilizing digital processing in advanced field-programmable gate arrays (FPGAs) to perform all of the many functions (for example, color balance and contrast adjustments) of a professional color video camera. The processing is programmed in VHDL so that application-specific integrated circuits (ASICs) can be fabricated directly from the program. ["VHDL" signifies VHSIC Hardware Description Language C, a computing language used by the United States Department of Defense for describing, designing, and simulating very-high-speed integrated circuits (VHSICs).] The image-sensor and FPGA clock frequencies in these cameras have generally been much higher than those used in video cameras designed and manufactured elsewhere. Frequently, the outputs of these cameras are converted to other video-camera formats by use of pre- and post-filters.

Glenn, William↗