Search NASA⌕ Search

SEARCH · Search NASA

Results for “high frequency ac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

System and component design and test of a 10 hp, 18,000 rpm AC dynamometer utilizing a high frequency AC voltage link, part 1

Hard and soft switching test results conducted with one of the samples of first generation MOS-controlled thyristor (MCTs) and similar test results with several different samples of second generation MCT's are reported. A simple chopper circuit is used to investigate the basic switching characteristics of MCT under hard switching and various types of resonant circuits are used to determine soft switching characteristics of MCT under both zero voltage and zero current switching. Next, operation principles of a pulse density modulated converter (PDMC) for three phase (3F) to 3F two-step power conversion via parallel resonant high frequency (HF) AC link are reviewed. The details for the selection of power switches and other power components required for the construction of the power circuit for the second generation 3F to 3F converter system are discussed. The problems encountered in the first generation system are considered. Design and performance of the first generation 3F to 3F power converter system and field oriented induction moter drive based upon a 3 kVA, 20 kHz parallel resonant HF AC link are described. Low harmonic current at the input and output, unity power factor operation of input, and bidirectional flow capability of the system are shown via both computer and experimental results. The work completed on the construction and testing of the second generation converter and field oriented induction motor drive based upon specifications for a 10 hp squirrel cage dynamometer and a 20 kHz parallel resonant HF AC link is discussed. The induction machine is designed to deliver 10 hp or 7.46 kW when operated as an AC-dynamo with power fed back to the source through the converter. Results presented reveal that the proposed power level requires additional energy storage elements to overcome difficulties with a peak link voltage variation problem that limits reaching to the desired power level. The power level test of the second generation converter after the addition of extra energy storage elements to the HF link are described. The importance of the source voltage level to achieve a better current regulation for the source side PDMC is also briefly discussed. The power levels achieved in the motoring mode of operation show that the proposed power levels achieved in the generating mode of operation can also be easily achieved provided that no mechanical speed limitation were present to drive the induction machine at the proposed power level.

Lipo, Thomas A.↗

Analysis of High Frequency AC Link Isolated Three Port Resonant Converter for UAV Applications

A high frequency AC link isolated three port semi-bridgeless resonant converter is analyzed for unmanned aerial vehicle (UAV) applications in this study. The proposed topology is established by replacing rectifier lover diodes with synchronous switches. A phase shifted pulse width modulation (PS-PWM) technique adjusts bi-directional power flow between ports. Proposed control technique provides high efficiency by reducing switching losses with zero voltage switching (ZVS) and zero current switching (ZCS) in a wide power range regulation. Compared to integrated PWM converters in a bi-directional mode, the proposed topology reduces the number of converter stages and allows centralized control at high operating frequency. Theoretical and experimental results demonstrate the feasibility and effectiveness of the proposed converter at a full power of 500 W in laboratory conditions.

Asa, Erdem↗

A Simple Space Vector Modulation of High-Frequency AC Linked Three-Phase-to-Single-Phase/DC Converter

High frequency (HF) ac linked converter functions well to interface between buses with different voltage types. Using a three-phase-to-single-phase matrix converter, a single-phase cyclo converter, and a HF transformer, we can compose a HF ac linked converter to interface between three-phase ac grids and single-phase ac or dc distributed generations (DGs). In this paper, a novel space vector modulation (SVM) method is proposed for such kind of converter. The proposed SVM method converts the mains three-phase ac voltage to a HF ac voltage at the primary side of transformer, and then unfolds the HF ac voltage to a single-phase ac or dc voltage at the secondary side of transformer. Without need to compute separate switching signals for the primary and secondary converters and then coordinate their operations elaborately, the proposed SVM method can be easily implemented by incorporating the HF chopping into the SVM of traditional indirect matrix converter. Therefore, no complicated duty cycle computation or elaborate switching states combination is required. Simulation and hardware-in-loop implementation demonstrate the validity of the proposed method.

42 ENGINEERING↗

Designing high frequency ac inductors using ferrite and Molypermalloy Powder Cores (MPP)

The major considerations in the design of high frequency ac inductors are reviewed. Two methods for designing the inductor: the area product method and the core geometry method, are presented. The two major effects of the inductor air gap, fringing flux power loss and increase of inductance, are discussed. Equations for the inductor design and a step-by-step design procedure are given. The use of a lumped air gap or a distributed air gap are discussed and a comparison of the losses resulting from these gaps, together with experimental results are presented.

Mclyman, W. T.↗

Power conversion distribution system using a resonant high-frequency AC link

Static power conversion systems based on a resonant high frequency (HF) link offers a significant reduction in the size and weight of the equipment over that achieved with conventional approaches, especially when multiple sources and loads are to be integrated. A faster system response and absence of audible noise are the other principal characteristics of such systems. A conversion configuration based on a HF link which is suitable for applications requiring distributed power is proposed.

Sood, P. K.↗

Analysis and Control of a Three-Port Converter with High-Frequency AC Link for Hybrid Unmanned/Autonomous Aerial Vehicles

In this study, a three-port resonant converter with a high-frequency isolation link for hybrid unmanned/autonomous aerial vehicle (UAV/AAV) applications is analyzed. The rectified engine-generator set output supplies the first input ports while the other is connected to a battery energy storage system. Input ports consist of half-bridge high-frequency inverters, whereas output port utilizes a semi-bridgeless active rectifier. This rectifier is formed by replacing rectifier low-side diodes with active switching devices. A phase-shift duty-cycle control is implemented for switching signals to regulate the power share and flow between ports. The proposed control system implemented achieves zero voltage switching (ZVS), reduces switching losses, and minimum current flow optimization ensures regulation in a wide range of output power. Compared to the existing bidirectional pulse width modulation (PWM) converters, the proposed system decreases the number of power conversion stages and provides centralized control without needing communications between the ports. The proposed control technique operating in closed-loop control achieves the power flow between ports under various load conditions. Finally, theoretical analysis demonstrates the proposed converter’s viability and laboratory experimental validations at 500 W full power.

33 ADVANCED PROPULSION SYSTEMS↗

High-Frequency ac Power-Distribution System

Loads managed automatically under cycle-by-cycle control. 440-V rms, 20-kHz ac power system developed. System flexible, versatile, and "transparent" to user equipment, while maintaining high efficiency and low weight. Electrical source, from dc to 2,200-Hz ac converted to 440-V rms, 20-kHz, single-phase ac. Power distributed through low-inductance cables. Output power either dc or variable ac. Energy transferred per cycle reduced by factor of 50. Number of parts reduced by factor of about 5 and power loss reduced by two-thirds. Factors result in increased reliability and reduced costs. Used in any power-distribution system requiring high efficiency, high reliability, low weight, and flexibility to handle variety of sources and loads.

Hansen, Irving G.↗

Resistojet control and power for high frequency ac buses

Resistojets are operational on many geosynchronous communication satellites which all use dc power buses. Multipropellant resistojets were selected for the Initial Operating Capability (IOC) Space Station which will supply 208 V, 20 kHz power. This paper discusses resistojet heater temperature controllers and passive power regulation methods for ac power systems. A simple passive power regulation method suitable for use with regulated sinusoidal or square wave power was designed and tested using the Space Station multipropellant resistojet. The breadboard delivered 20 kHz power to the resistojet heater. Cold start surge current limiting, a power efficiency of 95 percent, and power regulation of better than 2 percent were demonstrated with a two component, 500 W breadboard power controller having a mass of 0.6 kg.

Gruber, Robert P.↗

Resistojet control and power for high frequency ac buses

Resistojets are operational on many geosynchronous communication satellites which all use dc power buses. Multipropellant resistojets were selected for the Initial Operating Capability (IOC) Space Station which will supply 208 V, 20 kHz power. This paper discusses resistojet heater temperature controllers and passive power regulation methods for ac power systems. A simple passive power regulation method suitable for use with regulated sinusoidal or square wave power was designed and tested using the Space Station multipropellant resistojet. The breadboard delivered 20 kHz power to the resistojet heater. Cold start surge current limiting, a power efficiency of 95 percent, and power regulation of better than 2 percent were demonstrated with a two component, 500 W breadboard power controller having a mass of 0.6 kg.

Gruber, Robert P.↗

High-frequency ac power distribution in Space Station

A utility-type 20-kHz ac power distribution system for the Space Station, employing resonant power-conversion techniques, is presented. The system converts raw dc voltage from photovoltaic cells or three-phase LF ac voltage from a solar dynamic generator into a regulated 20-kHz ac voltage for distribution among various loads. The results of EASY5 computer simulations of the local and global performance show that the system has fast response and good transient behavior. The ac bus voltage is effectively regulated using the phase-control scheme, which is demonstrated with both line and load variations. The feasibility of paralleling the driver-module outputs is illustrated with the driver modules synchronized and sharing a common feedback loop. An HF sinusoidal ac voltage is generated in the three-phase ac input case, when the driver modules are phased 120 deg away from one another and their outputs are connected in series.

Tsai, Fu-Sheng↗

Fault Clearing Operation in Low-Frequency High-Voltage AC Systems

Abstract—Low-frequency high-voltage ac (LF-HVac) system has been proposed as an alternative to HVdc and HVac systems to reduce transmission losses and improve grid flexibility. LF-HVac system employs back-to-back (BTB) converters to interconnect and control the voltage and power interchange between two power grid operating at different frequencies. While there are multiple studies on LF-HVac system in the literature, the fault clearing method in the LF-HVac system has not been analyzed. Therefore, this paper focuses on fault clearing operation in LFHVac system and proposes a novel method to reduce fault current by changing operating frequency of power source and converter. The performance of the proposed method is validated using detailed models of BTB converters developed in PSCAD/EMTDC. The ability to change operating frequency at the onset of a fault condition allows breakers to rapidly clear the fault and recloses. The results obtained by using the proposed method substantially diminish the fault current.

Kim, Woosung↗

A 20 kiloHertz space station power system

The space station represents the next major U.S. commitment in space. The efficient delivery of power to multiple user loads is key to that success. In 1969, NASA Lewis Research Center began a series of studies with component and circuit developments that led to the high frequency, bi-directional, four quadrant resonant driven converter. Additional studies and subsequent developments into the early 1980's have shown how the high frequency ac power system could provide overall advantages to many aerospace power systems. Because of its wide versatility, it also has outstanding advantages for the Space Station Program and its wide range of users. High frequency ac power provides higher efficiency, lower cost, and improved safety. The 20 kHz power system has exceptional flexibility, is inherently user friendly, and is compatible with all types of energy sources - photovoltaic, solar dynamic, rotating machines or nuclear. Lewis has recently completed development under contract a 25 kW, 20 kHz ac power distribution system testbed. The testbed demonstrates flexibility, versatility, and transparency to user technology as well as high efficiency, low mass, and reduced volume.

Hansen, I. G.↗

20 kHz Space Station power system

The Space Station represents the next major U.S. commitment in space. The efficient delivery of power to multiple user loads is key to that success. In 1969, NASA Lewis Research Center began a series of studies with component and circuit developments that led to the high frequency bi-directional, four quadrant resonant driven converter. Additional studies and subsequent developments into the early 1980's have shown how the high frequency ac power system could provide overall advantages to many aerospace power systems. Because of its wide versatility, it also has outstanding advantages for the Space Station Program and its wide range of users. High frequency ac power provides higher efficiency, lower cost, and improved safety. The 20 kHz power system has exceptional flexibility, is inherently user friendly, and is compatible with all types of energy sources - photovoltaic, solar dynamic, rotating machines or nuclear Lewis distribution system testbed. The testbed demonstrates flexibility, versatility, and transparency to user technology as well as high efficiency, low mass, and reduced volume.

Hansen, Irving G.↗

A study of some features of ac and dc electric power systems for a space station

This study analyzes certain selected topics in rival dc and high frequency ac electric power systems for a Space Station. The interaction between the Space Station and the plasma environment is analyzed, leading to a limit on the voltage for the solar array and a potential problem with resonance coupling at high frequencies. Certain problems are pointed out in the concept of a rotary transformer, and further development work is indicated in connection with dc circuit switching, special design of a transmission conductor for the ac system, and electric motors. The question of electric shock hazards, particularly at high frequency, is also explored. and a problem with reduced skin resistance and therefore increased hazard with high frequency ac is pointed out. The study concludes with a comparison of the main advantages and disadvantages of the two rival systems, and it is suggested that the choice between the two should be made after further studies and development work are completed.

Hanania, J. I.↗

Modular power conversion system with galvanic insulation

A modular power conversion system is provided which includes a plurality of building blocks comprised of transformers and power conversion bridges, and a high frequency AC link that transfers power and provides galvanic isolation between the building blocks. The high frequency link includes an insulating tube separating an AC link conductor and the building blocks. The insulating tube is further provided with conductive or semiconductive layers on its inner and outer surfaces for referencing them to the electric potentials of the adjacent conductors and windings, thereby placing the high electric fields substantially directly across the tube and reducing electric fields and partial discharge or corona in the adjoining space or media. The building blocks may be arranged in multiple stacks for DC or AC interface, preferably with neutral or lower voltage connections at the outer edges of the stacks and higher voltage terminals at the centers of the stack.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pulse-train drive system for electrostatic generators and motors

A novel motor drive system has been described for use in electrostatic generator/motor systems based on the time variation of capacity of a rotating condenser comprised of segmented rotor and stator elements. It takes advantage of the fact that the motor action of such a system depends only on the rms value of the drive pulses, which therefore can be formed simply by periodically interrupting a high-frequency ac wave train. This new circuitry simplifies the drive system and takes advantage of recent developments of devices used in the art of inversion of dc voltages to high-frequency (tens of kiloHz) ac.

42 ENGINEERING↗

Anisotropic colloidal interactions & assembly in AC electric fields

In this work, we match experimental and simulated configurations of anisotropic epoxy colloidal particles in high frequency AC electric fields by identifying analytical potentials for dipole-field and dipole-dipole interactions. We report an inverse Monte Carlo simulation algorithm to determine optimal fits of analytical potentials by matching simulated and experimental distribution functions for non-uniform liquid, liquid crystal, and crystal microstructures in varying amplitude electric fields. Two potentials that include accurate particle volume and dimensions along with a concentration dependent prefactor quantitatively capture experimental observations. At low concentrations, an effective ellipsoidal point dipole potential works well, whereas a novel stretched point dipole potential is found to be suitable at all concentrations, field amplitudes, and degrees of ordering. The simplicity, accuracy, and adjustability of the stretched point dipole potential suggest it can be applied to model field mediated microstructures and assembly of systematically varying anisotropic particle shapes.

42 ENGINEERING↗

Power Conditioning System Modelling for Nuclear Electric Propulsion

NASA LeRC is currently developing a Fortran based model of a complete nuclear electric propulsion (NEP) vehicle that would be used for piloted and cargo missions to the Moon or Mars. The proposed vehicle design will use either a Brayton or K-Rankine power conversion cycle to drive a turbine coupled with a rotary alternator. Two thruster types are also being studied, ion and magnetoplasmadynamic (MPD). In support of this NEP model, Rocketdyne developed a power management and distribution (PMAD) subroutine that provides parametric outputs for selected alternator operating voltages and frequencies, thruster types, system power levels, and electronics coldplate temperatures. The end-to-end PMAD model described is based on the direct use of the alternator voltage and frequency for transmitting power to either ion or MPD thrusters. This low frequency transmission approach was compared with dc and high frequency ac designs, and determined to have the lowest mass, highest efficiency, highest reliability and lowest development costs. While its power quality is not as good as that provided by a high frequency system, it was considered adequate for both ion and MPD engine applications. The low frequency architecture will be used as the reference in future NEP PMAD studies.

Metcalf, Kenneth J.↗