Search NASA⌕ Search

SEARCH · Search NASA

Results for “high frequency of measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Apparatus for measuring high frequency currents

An apparatus for measuring high frequency currents includes a non-ferrous core current probe that is coupled to a wide-band transimpedance amplifier. The current probe has a secondary winding with a winding resistance that is substantially smaller than the reactance of the winding. The sensitivity of the current probe is substantially flat over a wide band of frequencies. The apparatus is particularly useful for measuring exposure of humans to radio frequency currents.

Hagmann, Mark J.↗

Condenser Microphone Protective Grid Correction for High Frequency Measurements

Use of a protective grid on small diameter microphones can prolong the lifetime of the unit, but the high frequency effects can complicate data interpretation. Analytical methods have been developed to correct for the grid effect at high frequencies. Specifically, the analysis pertains to quantifying the microphone protective grid response characteristics in the acoustic near field of a rocket plume noise source. A frequency response function computation using two microphones will be explained. Experimental and instrumentation setup details will be provided. The resulting frequency response function for a B&K 4944 condenser microphone protective grid will be presented, along with associated uncertainties

Lee, Erik↗

High-frequency measurements of multilayer ceramic capacitors

A resonant coaxial transmission line, short circuited at one end and open circuited at the other, whose fundamental resonant frequency and Q factor are known, is perturbed with a test capacitor connected either in series at the shorted end of the line, or in shunt at the open end. Measuring the Q factor of the system with the delta f technique yields the effective series resistance, capacitance, and the Q factor of the test specimen. This method of measurement has the advantage that there are no adjustable elements to alter circuit conditions in an unprescribed way, the only variable is the frequency which can be measured with an uncertainty of less than 1 ppm, the loss of the line as a function of frequency is quite predictable, and the Q factor of the line can be made sufficiently high to support accurate measurements of low loss capacitors.

Lafferty, R. E.↗

Absorption of sound in air - High-frequency measurements

The absorption of sound in air at frequencies from 4 to 100 kHz in 1/12 octave intervals, for temperatures from 255.4 K (0 F) to 310.9 K (100 F) in 5.5 K (10 F) intervals, and at 10% relative-humidity increments between 0% and saturation has been measured. The values of free-field absorption have been analyzed to determine the relaxation frequency of oxygen for each of the 92 combinations of temperature and relative humidity studied and the results are compared to an empirical expression. The relaxation frequencies of oxygen have been analyzed to determine the microscopic energy-transfer rates.

Bass, H. E.↗

High Frequency Measurements of the Spectrum of Sgr A(sup *)

We report near-simultaneous interferometric measurements of the spectrum of Sgr A(sup *) over the 5 to 354 GHz range, and single-dish observations which have yielded the first detection of Sgr A(sup *) at 850 GHz. We confirm that Sgr A(sup *)'s spectrum rises more steeply at short mm wavelengths than at cm wavelengths, leading to a near-millimeter/submillimeter excess which dominates its luminosity. Below 900 GHz, Sgr A(sup *)'s observed luminosity is 70 +/- 30 solar luminosity). A new upper limit to Sgr A(sup *)'s 24.3 microns flux, together with a compilation of other extant IR data, imply a FIR spectral turnover, which can result either from an intrinsic synchrotron cutoff, or excess extinction near Sgr A(sup *). If the former applies, Sgr A(sup *)'s total synchrotron luminosity is less than 10(exp 3) solar luminosity, while in the latter case it is less than 3 x 10(exp 4) solar luminosity if spherical symmetry also applies.

Serabyn, E.↗

High-Frequency Measurements of Methane Ebullition Over a Growing Season at a Temperate Peatland Site

Bubbles can contribute a significant fraction of methane emissions fr om wetlands; however the range of reported fractions is very large an d accurate characterization of this pathway has proven difficult. Her e we show that continuous automated flux chambers combined with an in tegrated cavity output spectroscopy (ICOS) instrument allow us to qua ntify both CH4 ebullition rate and magnitude. For a temperate poor f en in 2009, ebullition rate varied on hourly to seasonal time scales. A diel pattern in ebullition was identified with peak release occurr ing between 20:00 and 06:00 local time, though steady fluxes (i.e., t hose with a linear increase in chamber headspace CH4 concentration) d id not exhibit diel variability. Seasonal mean ebullition rates peake d at 843.5 +/- 384.2 events m(exp -2)/d during the summer, with a me an magnitude of 0.19 mg CH4 released in each event.

Goodrich, Jordan P.↗

Microphone Corrections for Accurate In-Flow Acoustic Measurements at High Frequency

Acoustic analysis of aircraft components through small-scale experiments in wind tunnels requires in-flow acoustic measurements at high frequencies. This high frequency information is shifted to lower frequencies during the geometric scaling process. As a result, models of scale one tenth and smaller require frequency information of up to at least 100 kHz to resolve the midpoint of the full-scale equivalent audible range. Farfield acoustic measurements of frequencies higher than 100 kHz are prohibitively difficult to make due to the physical limitations of atmospheric propagation over large distances and the delicacy of the required instruments. Even measurements up to 100 kHz require special corrections and calibration procedures to maintain sufficient accuracy. In-flow microphone measurements at high frequencies require additional consideration due to the presence of the aerodynamic microphone forebody which protects the microphone diaphragm from flow impingement. The screen located at the forebody surface attenuates the high frequency acoustic waves and must be accounted for. The purpose of this paper is to present procedures for calibrating and correcting high frequency acoustic measurements to retain high accuracy. Specifically, this paper gives calibration procedures and examples of typical data for calibrating or correcting for five physical effects. These effects include the frequency response of the entire acoustic data acquisition system, intrusion of the microphone into the acoustic field, forebody screen attenuation, directionality of microphone forebody response and atmospheric absorption.

Allen, Christopher S.↗

Molecular Rayleigh Scattering Diagnostic for Measurement of High Frequency Temperature Fluctuations

A novel technique for measurement of high frequency temperature fluctuations in unseeded gas flows using molecular Rayleigh scattering is investigated. The spectrum of laser light scattered from molecules in a gas flow is resolved using a Fabry-Perot interferometer. The width of the spectral peak is broadened by thermal motion of the molecules and hence is related to gas temperature. The interference fringe pattern containing spectral information is divided into four concentric regions using a series of mirrors angled with respect to one another. Light from each of these regions is directed towards photomultiplier tubes and sampled at 10 kHz using photon counting electronics. Monitoring the relative change in intensity within each region allows measurement of gas temperature. Independently monitoring the total scattered intensity provides a measure of gas density. This technique also has the potential to simultaneously measure a single component of flow velocity by monitoring the spectral peak location. Measurements of gas temperature and density are demonstrated using a low speed heated air jet surrounded by an unheated air co-flow. Mean values of temperature and density are shown for radial scans across the jet flow at a fixed axial distance from the jet exit plane. Power spectra of temperature and density fluctuations at several locations in the jet are also shown. The instantaneous measurements have fairly high uncertainty; however, long data records provide highly accurate statistically quantities, which include power spectra. Mean temperatures are compared with thermocouple measurements as well as the temperatures derived from independent density measurements. The accuracy for mean temperature measurements was +/- 7 K.

Mielke, Amy F.↗

High Temperature / High Frequency Temperature Measurement: Achieving MHz Response at Temperatures > 1000 Deg-F

High frequency temperature measurements are not possible with current SOA temperature measurement devices at temperatures higher than ~700 deg-F. Temperature measurements above ~1000 deg-F are typical for entry vehicle thermal protection systems (TPS), rocket engines, ram/scramjet engines, etc. A new technology capable of achieving ~1200 deg-F temperature measurements with MHz response has been achieved. Investigations are underway to extend the concept to even higher temperatures. A U.S. patent application is about to be submitted.

High Frequency↗

Measurement of high frequency waves using a wave follower

High frequency waves were measured using a laser-optical sensor mounted on a wave follower. Measured down-wind wave slope spectra are shown to be wind speed dependent; the mean square wave-slopes are generally larger than those measured by Cox and Munk (1954) using the sun glitter method.

Tang, S.↗

Helicopter rotor rotational noise predictions based on measured high-frequency blade loads

In tests conducted at the Langley helicopter rotor test facility, simultaneous measurements of up to 200 harmonics of the fluctuating aerodynamic blade surface pressures and far-field radiated noise were made on a full-scale nontranslating rotor system. After their characteristics were determined, the measured blade surface pressures were converted to loading coefficients and used in an existing theory to predict the far-field rotational noise. A comparison of the calculated and measured noise shows generally good agreement up to 300 to 600 Hz, depending on the discreteness of the loading spectrum. Specific attention is given to the effects of the blade loading coefficients, chordwise loading distributions, blade loading phases, and observer azimuthal position on the calculations.

Hosier, R. N.↗

Preliminary study of the interactions caused by crossing shock waves and a turbulent boundary layer

The subject research, the first phase of an extended study of the interaction of crossing shock waves with a turbulent boundary layer, has revealed the complexity of the resulting flow. Detailed surface visualization and mean wall static pressure distributions show little resemblance to the inviscid flow approximation, and the exploratory high frequency measurements show that the flow downstream of the theoretical inviscid shock crossing position has a significant unsteady characteristic. Further developments of the (unsteady) high frequency measurements are required to fully characterize the unsteadiness and the requirements to include this component in flowfield modeling.

Ketchum, A. C.↗

Thin Film Ba(x)Sr(1-x)TiO3 Ku- and K-Band Phase Shifters Grown on MgO Substrates

We report measurements of gold circuits fabricated on four Ba(x)Sr(1-x)TiO3 films doped with 1% Mn grown on MgO substrates by laser ablation. Low frequency measurements of epsilon(sub r) and tan(delta) on interdigital capacitors are compared with high frequency measurements of phase shift and insertion loss on coupled microstrip phase shifters done on the same films. The variation in temperature of both high and low frequency device parameters is compared. Annealed and unannealed films are compared. Room temperature figures of merit of phase shift per insertion loss of up to 58.4 C/dB at 18 GHz and 400 V dc bias were measured.

VanKeuls, F. W.↗

Towards a High Temporal Frequency Grass Canopy Thermal IR Model for Background Signatures

In this paper, we present our first results towards understanding high temporal frequency thermal infrared response from a dense plant canopy and compare the application of our model, driven both by slowly varying, time-averaged meteorological conditions and by high frequency measurements of local and within canopy profiles of relative humidity and wind speed, to high frequency thermal infrared observations. Previously, we have employed three-dimensional ray tracing to compute the intercepted and scattered radiation fluxes and for final scene rendering. For the turbulent fluxes, we employed simple resistance models for latent and sensible heat with one-dimensional profiles of relative humidity and wind speed. Our modeling approach has proven successful in capturing the directional and diurnal variation in background thermal infrared signatures. We hypothesize that at these scales, where the model is typically driven by time-averaged, local meteorological conditions, the primary source of thermal variance arises from the spatial distribution of sunlit and shaded foliage elements within the canopy and the associated radiative interactions. In recent experiments, we have begun to focus on the high temporal frequency response of plant canopies in the thermal infrared at 1 second to 5 minute intervals. At these scales, we hypothesize turbulent mixing plays a more dominant role. Our results indicate that in the high frequency domain, the vertical profile of temperature change is tightly coupled to the within canopy wind speed In the results reported here, the canopy cools from the top down with increased wind velocities and heats from the bottom up at low wind velocities. .

Ballard, Jerrell R., Jr.↗

Advanced Global Atmospheric Gases Experiment (AGAGE)

We seek funding from NASA for the third year (2005) of the four-year period January 1, 2003 - December 31, 2006 for continued support of the MIT contributions to the multi-national global atmospheric trace species measurement program entitled Advanced Global Atmospheric Gases Experiment (AGAGE). The case for real-time high-frequency measurement networks like AGAGE is very strong and the observations and their interpretation are widely recognized for their importance to ozone depletion and climate change studies and to verification issues arising from the Montreal Protocol (ozone) and Kyoto Protocol (climate). The proposed AGAGE program is distinguished by its capability to measure over the globe at high frequency almost all of the important species in the Montreal Protocol and almost all of the significant non-CO2 gases in the Kyoto Protocol.

Prinn, Ronald G.↗

Ares I Scale Model Acoustic Test Instrumentation for Acoustic and Pressure Measurements

Ares I Scale Model Acoustic Test (ASMAT) is a 5% scale model test of the Ares I vehicle, launch pad and support structures conducted at MSFC to verify acoustic and ignition environments and evaluate water suppression systems Test design considerations 5% measurements must be scaled to full scale requiring high frequency measurements Users had different frequencies of interest Acoustics: 200 - 2,000 Hz full scale equals 4,000 - 40,000 Hz model scale Ignition Transient: 0 - 100 Hz full scale equals 0 - 2,000 Hz model scale Environment exposure Weather exposure: heat, humidity, thunderstorms, rain, cold and snow Test environments: Plume impingement heat and pressure, and water deluge impingement Several types of sensors were used to measure the environments Different instrument mounts were used according to the location and exposure to the environment This presentation addresses the observed effects of the selected sensors and mount design on the acoustic and pressure measurements

Vargas, Magda B.↗

Using Small Unmanned Aerial Systems (sUAS) and Helium Aerostats to Perform Far-Field Radiation Pattern Measurements of High-Frequency Antennas

A new methodology is described for performing near-free space far-field radiation pattern measurements of high frequency (HF) antennas utilizing small Unmanned Aerial Systems (sUAS) and helium-filled aerostat balloons for the radar antennas onboard NASA’s planned Europa Clipper mission to Jupiter’s moon Europa. Adapted from land-based measurements, this test methodology involves hoisting the antenna to be tested above the earth to minimize ground interactions while flying a sUAS with onboard measurement package to map the far field radiation pattern. Initial results producing radiation pattern maps are promising with work remaining to fully adapt fixed VHF measurements to the dynamic HF antenna test setup.

Decrossas, Emmanuel↗