High Gradient High Q0 SRF Cavity Development at JLAB
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
High strength magnetic fields effect on early embryonic development of frogs, relating growth abnormalities and paramagnetic ferritin motions
High brightness beams appealing for XFELs and UEM essentially imply a high current and a low emittance. To obtain such beams we propose to raise the accelerating voltage in the gun mitigating repealing Coulomb forces. An ultra-high gradient is achieved utilizing a short-pulse technology. We have designed a room temperature X-band 1,5 cell gun that is able to inject 4 MeV, 100 pC bunches with as low as 0.15 mcm normalized transverse emittance. The gun is operated with as high gradients as 400 MV/m and fed by 200 MW, 10 ns RF pulses generated with Argonne Wakefield Accelerator (AWA) power extractor. We report results of low RF power tests, laser alignment test results, and successful gun conditioning results carried out at nominal RF power.
High-gradient acceleration is a key research area that could enable compact linear accelerators for future colliders, light sources, and other applications. In the pursuit of high-gradient operation, rf breakdown limits the attainable accelerating gradient in normal-conducting rf structures. Recent experiments at the Argonne Wakefield Accelerator suggest a promising approach: using short rf pulses with durations of a few nanoseconds. Experimental studies show that these 𝒪(1 ns) rf pulses can mitigate breakdown limitations, resulting in higher gradients. For example, an electric field of nearly 400 MV/m was achieved in an 𝑋-band photoemission gun driven by 6-ns-long rf pulses, with rapid rf conditioning and low dark current observed. Despite these promising results, the short-pulse regime remains an underexplored parameter space, and rf breakdown physics under nanosecond-long pulses requires further investigation. In this paper, we present analytical and numerical simulations of dark current dynamics in accelerating cavities operating in the short-pulse regime. We study breakdown-associated processes spanning different time scales, including field emission, multipacting, and plasma formation, using simulations of the 𝑋-band photogun cavities. The results reveal the advantages of using short rf pulses to reduce dark current and mitigate rf breakdown, offering a path toward a new class of compact accelerators with enhanced performance and reduced susceptibility to breakdown.
High Gradient Magnetic Filtration (HGMF) is a promising method for the selective capture and recovery of uranium oxide from surface soils. To date, however, magnetic filtration of uranium oxide has only been demonstrated at a proof-of-principle scale using relatively small filters (<5 cm 3 ) at low flowrates (<60 mL/min). Here, to explore the efficacy of magnetic filtration of uranium oxide at a larger scale, a newly designed HGMF apparatus that is more than an order of magnitude larger than our earlier filters (106 cm 3 ) was designed, fabricated, and tested at relatively high flowrates. Filtration experiments were performed using aqueous uranium oxide particle suspensions with Arizona Road Dust (ARD) as a soil simulant. At a flowrate of 125 mL/min, the apparatus’ uranium capture rate was exceptionally high (96 %), but selectivity was poor due to the high rate of capture for diamagnetic soil constituents (e.g., 77 % for silicon). All particles were captured at a lower rate when the flowrate was increased to 250 mL/min, but uranium selectivity was significantly increased due to the more substantial reduction in diamagnetic particle capture (i.e., capture rate of 77 % and 15 % for uranium and silicon, respectively). When backwashing the apparatus at the same flowrates used during filtration experiments, the rate of uranium recovery tended to be fairly low. Nevertheless, higher flowrates (1 L/min) and sonication were both shown to be highly effective methods of increasing uranium recovery. Magnetic field simulations were also performed to investigate potential optimizations to the design of the apparatus. These simulations showed that the intensity of the applied magnetic field could be increased by increasing the thickness of the steel magnetic housing. Additionally, stochastic trajectory simulations were performed to investigate the potential mechanisms of particle capture.
High Gradient Furnace with Quench (HGFQ) is being developed to facilitate metals processing experiments aboard the International Space Station. The sample is centered in an annular furnace and is held fixed during processing. The furnace itself is made to translate over the sample. Once in process, heat will flow through the sample from the Heater Zone to the Chill Zone. If operating conditions are correct, the solidification interface will stand in the gradient zone. Objectives of the HGFQ process are to provide a high gradient for the solidification with the solidification interface properly positioned in the gradient zone. At the recent RDR for HGFQ, one of the panelists raised the question about the suitability of HGFQ for potential future PIs. Specifically, it was stated by the design team at RDR that the present HGFQ design would provide a radius of curvature of the solidification interface of at least one sample diameter. The RDR panel argued that this was too small, and that most investigators would need a radius of curvature larger than this. The requirements established by the current PIs are shown. These requirements do not contain any specification about the interface shape. However, these requirements do define the envelope of operational parameters for HGFQ. The objectives of the present investigation are to 1) determine a suitable means of quantifying the interface shape, and 2) investigate the interface shape and how it is affected by processing parameters. The processing parameters to be considered are 1) sample material, 2) sample diameter, and 3) gradient zone length.
A high gradient linear accelerating structure can propagate high frequency waves at a negative harmonic to accelerate low-energy ions. The linear accelerating structure can provide a gradient of 50 MV/m for particles at a β of between 0.3 and 0.4. The high gradient structure can be a part of a linear accelerator configured to provide an energy range from an ion source to 450 MeV/u for 12 C 6+ and 250 MeV for protons. The linear accelerator can include one or more of the following sections: a radiofrequency quadrupole (RFQ) accelerator operating at the sub-harmonic of the S-band frequency, a high gradient structure for the energy range from ˜45 MeV/u to ˜450 MeV/u.
This final technical report summarizes the development of structure wakefield accelerator (SWFA) technology to enable high-gradient, efficient particle acceleration.
Accelerating particles at high gradients with high efficiencies is essential for reduction of size and cost of future accelerators for science and industry. This includes a future multi-TeV e+e- collider for particle, free-electron lasers for basic energy sciences and national security, industrial accelerators for energy and environmental applications, and accelerators for other applications. One way to achieve this is to use advanced externally-powered structures, both laser and RF driven. Working Group 3 (WG3) discussed novel accelerating structures with new geometries, new materials, frequencies from microwave to THz and optical spectrum, and operating conditions from room temperature to cryogenic. Presentations included recent advances in understanding RF breakdown and multipactor phenomena at different frequencies and materials, and other physics limitations to the accelerating gradient. Other relevant topics, such as developing high-gradient photoinjectors, high-efficiency RF power sources, and RF structures for a potential muon collider were discussed also. More details on each of the WG3 topics can be found in the articles published in these proceedings.
We report on recent research on high-gradient radio frequency (RF) accelerating structures indicates that the use of hard copper alloys provides improvement in high gradient performance over annealed copper. Such structures are made by bonding individually manufactured parts. However, there are no well-established bonding techniques that preserve the hardness, surface finish and cleanliness required for high gradient operation. To preserve the copper hardness, RadiaBeam has developed a novel high-gradient split accelerating structure, based on electron beam welding joining technique. This technique provides efficient bonding with strong, clean welds and minimal thermal loading, while maintaining a clean inner RF environment. Our RF design and fabrication methodology limits the small heat affected zone to the outer cavity envelop, with virtually no distortions or thermal loading of critical RF surfaces. It also incorporates provisions to precisely control the gap despite conventional issues with weld joint shrinkage. To date we have manufactured and validated an RF accelerating structure joined by electron-beam welding that incorporates a novel open split design to significantly reduce the assembly complexity and cost. In this paper, we will present the electromagnetic design of this structure, discuss bonding, and present the results of high-power tests, where the accelerating gradients of 140 MV m -1 with surface peak fields of 400 MV m -1 were achieved for flat-top pulse length of 600 ns with an RF breakdown rate of 10 -4 1/(pulsecm).
We have conducted an intensive, pioneering program to demonstrate novel concepts for achieving high gradient acceleration at frequencies from the conventional microwave bands up to the millimeter wave /THz bands. High gradient accelerators hold the promise of smaller and less costly accelerators for applications ranging from the largest scale accelerators used for discovery science down to the smallest accelerators used for industrial, homeland security and medical applications. The research consisted of two major research thrusts: 1.) Structure-based wakefield accelerator (SWFA) research in collaboration with the Argonne Wakefield Accelerator research group and 2.) Millimeter Wave / THz high gradient acceleration in collaboration with SLAC. The specific goals of the research program were: Design novel metallic metamaterial structures that increase the beam-wave coupling for the accelerator mode and reduce the effect of high order modes; test novel metamaterial structures to achieve higher output power, > 1 GW at X-Band (11.7 GHz), in test at the Argonne Wakefield Accelerator (AWA); determine the experimental breakdown threshold for nanosecond-scale pulses at X-Band in testing at the AWA; test a 110 GHz accelerator structure with a field emission electron gun, built at SLAC, using pulses from a 1 MW, 110 GHz gyrotron; design, build and test a 110 GHz quasi-optical, resonant-ring pulse compressor to compress microsecond pulses from the 1 MW gyrotron into > 20 MW, 5 ns output pulses for accelerator structure testing. The proposed research program built on our successes in our research program including: Generation of 510 MW, 2.1 ns (FWHM) pulses at 11.7 GHz from a metallic metamaterial structure in test at the Argonne Wakefield Accelerator using a train of eight 65 MeV electron bunches spaced at 1.3 GHz with a total charge of 280 nC. The metamaterial structure consisted of 100 copper unit cells each consisting of a “wagon-wheel” plate and a spacer plate with a total structure length of 0.2 m. The 510 MW pulse generated an on-axis wakefield of 130 MV/m that could be used to accelerate a trailing witness bunch. Demonstration of coupling of an unprecedented rf power level of 575kW into a 110 GHz accelerator structure using a quasi-optical setup. The standing structure consisted of a central copper cavity located between two matching cavities fed by a TM01 mode. The 6 ns input pulses were sliced from 3 microsecond pulses from the gyrotron using a laser-driven silicon switch. We obtained an unprecedented high gradient up to 230MV/m corresponding to a peak surface electric field of more than 520 MV/m.
Achieving high-gradient performance (low breakdown rates, low field emission, new materials for HOM absorption, cathodes at high gradient etc.) is a materials science problem. Los Alamos is, at core, a materials science laboratory with particular expertise in metallurgy. Los Alamos also considers itself the steward of accelerator science for the NNSA part of the DOE complex. Thus, Los Alamos has both an institutional interest in, and capability to address, this problem space. High gradient C-band work directly aligns with future NNSA and LANL missions.
The effectiveness of High Gradient Magnetic Filtration (HGMF) in capturing uranium oxide particles from suspensions was investigated in this study. Two sets of experiments were performed to evaluate the importance of size on the capture of uranium oxide particles. The first considered two batches sieved into size bins of< 5, 5–10, 10–15, and 15–20 µm, while the second was performed using two suspensions with diameters smaller than 1.0 µm and between 1.0 and 1.5 µm. Iron oxide experiments, with particles between 0.3 and 0.8 µm, were performed for calibration purposes. In all experiments, a surfactant (Triton-X100 or sodium dodecyl sulfate) was used to prevent particle aggregation and limit the influence of non-magnetic capture mechanisms. A magnetic field of approximately 1.1 Tesla was generated using a water cooled electromagnet. HGMF was performed using tubular filters packed with ferromagnetic stainless-steel wool. Of the initial four uranium oxide particle sizes, magnetic capture was only observed for particles with a diameter of less than 5 µm, while larger particles experienced no magnetic and minimal total capture. For particles with diameters smaller than 1.0 µm and between 1.0 and 1.5 µm, capture efficiencies increased by 39 ± 9% and 34 ± 6% respectively, solely due to the magnetic field. Although the magnetic force is proportional to particle diameter, the capture efficiency decreased as diameter increased. So these results suggest that Brownian diffusion, which is influential for micron sized particles and increases with decreasing particle size, is acting in conjunction with the magnetic force to influence the efficacy of HGMF for uranium oxide. This important finding underscores the effectiveness of Brownian diffusion in increasing the rate of collision between particles and collector fibers. A stochastic trajectory model was developed to incorporate the influence of Brownian motion on particle behavior and filter removal efficiency. Modeling results are discussed and compared for uranium and iron oxide particles.
High gradient allows rapid growth rates in directionally-solidified eutectic alloys. Furnace design permits cost reductions in directional solidification process through its increased solidification rates, which reduces melt/mold interaction. It produces structural engineering materials for any application requiring properties directionally-solidified eutectic materials.
A high gradient directional solidification furnace is disclosed which includes eight thermal zones throughout the length of the furnace. In the hot end of the furnace, furnace elements provide desired temperatures. These elements include Nichrome wire received in a grooved tube which is encapsulated y an outer alumina core. A booster heater is provided in the hot end of the furnace which includes toroidal tungsten/rhenium wire which has a capacity to put heat quickly into the furnace. An adiabatic zone is provided by an insulation barrier to separate the hot end of the furnace from the cold end. The old end of the furnace is defined by additional heating elements. A heat transfer plate provides a means by which heat may be extracted from the furnace and conducted away through liquid cooled jackets. By varying the input of heat via the booster heater and output of heat via the heat transfer plate, a desired thermal gradient profile may be provided.
Operation of normal conducting accelerator structures at high accelerating gradients is beneficial for many accelerator applications in basic science, industry, medicine, and National Security. RF breakdown is the major factor that limits the achievable accelerating gradients. Previous experiments on copper (Cu) have demonstrated that RF breakdown probability can be significantly decreased by hardening the material and alloying Cu with solutes such as silver (Ag). In this paper, we propose a figure-of-merit (FOM) that characterizes the ability of Cu alloys to withstand high-gradients. The FOM represents a trade-off between hardening through solid solution strengthening and the additional thermal stress induced by incremental RF pulse heating resulting from changes in electronic properties induced by alloying. We performed high-throughput ab initio calculations and computed the FOM for a large number of binary Cu alloys. Several promising candidate alloys for high-gradient accelerating structures were identified, such as CuAg, CuCd, CuHg, CuAu, CuIn, and CuMg. CuAg alloys have previously exhibited low RF breakdown rates in experiments. The results provide guidance for selecting alloys for the future high-gradient normal conducting accelerating structures operating at very high gradients.
A short pulse high gradient RF gun has been recently tested at Argonne Wakefield Accelerator (AWA) facility. The carried-out test showed that the 1,5-cell gun was able to inject 3 MeV, up to 100 pC bunches at room tem-perature being fed by 9 ns up to 300 MW 11.7 GHz puls-es. The cathode field was as high as about 400 MV/m. So high field is aimed to mitigate repealing Coulomb forces substantially. In accordance with simulations the emit-tance could be as low as less than 0.2 mcm. To obtain so low emittance in the experiment, the gun is assumed to be equipped with a downstream linac to be fed from the same power extractor as the gun itself. Here we report design of the RF power distribution system splitting RF power among the gun and the linac, results of low-power tests, and emittance measurement plans for upcoming new experiment at AWA.
A new design furnace for high gradient solidification of in-situ composites is presented. Its essential feature is the direct addition of heat to one side of a thin, pancake-like layer of liquid, and continuous withdrawal of a solid crystal from the other side. Liquid in the thin layer is continuously replenished by solid or liquid feed, and the thinness of the layer permits a large heat throughput with a high temperature gradient without excessive metal superheat. The commercial advantages of this design are improved process efficiency in scale-up, lower melt temperatures, and control of interface morphology by adjusting heater position and temperature. The furnace was tested on Sn-Pb and Al-Cu alloys, obtaining 100C/mm gradients for 6 mm specimens of Al-31.5 % Cu alloy.